Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Neck”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Lower neck injury criteria for THOR and Hybrid III dummies in rear impact

The objectives of the study are to derive lower-neck-injury probability curves under rear impact loading from matched pair Hybrid III and THOR dummy tests. Methods: Twelve whole-body and 15 isolated head-neck rear-impact sled tests were conducted using the 2 dummies. They were positioned on a rigid seat that was attached to an acceleration sled. The dummies were positioned with the head parallel to the ground, torso against the seat back, and legs stretched such that there was no axial rotation. The acceleration pulse matched the previous in-house human cadaver tests. The 6-axis lower-neck load cell was used in both dummies. For the isolated rear-impact tests,the head-neck was excised from the dummies, and the lower-neck load cell was mounted to the top of the sled with the head parallel to the ground and such that the acceleration vector was in the rear impact mode. Lower-neck loads and lower-neck-injury criteria (LNij) were obtained using the load cell data and survival analysis to develop injury-assessment-risk values and curves for both dummies. The LNij criteria were determined for both dummies using the intercept value corresponding to the 90% probability level for the forces and moments. Results: The log normal and Weibull distributions were the optimal distributions for the Hybrid III and THOR devices. At the 50% risk level, the mean LNij of 1.1 and NCIS was 0.77 for the Hybrid III, and 1.5 NCIS was 0.30 for the THOR device. The quality indices were in the fair range and good range for the 2 dummies, respectively, at this risk level. Conclusions: The lower-neck-based IARCs and IARVs serve as the first dataset for injury assessments, and the THOR may be a better test device for assessing injures in rear impact environments.

Narayan Yoganandan

Noninvasive analysis of human neck muscle function

STUDY DESIGN. Muscle use evoked by exercise was determined by quantifying shifts in signal relaxation times of T2-weighted magnetic resonance images. Images were collected at rest and after exercise at each of two intensities (moderate and intense) for each of four head movements: 1) extension, 2) flexion, 3) rotation, and 4) lateral flexion. OBJECTIVE. This study examined the intensity and pattern of neck muscle use evoked by various movements of the head. The results will help elucidate the pathophysiology, and thus methods for treating disorders of the cervical musculoskeletal system. SUMMARY OF BACKGROUND DATA. Exercise-induced contrast shifts in T2 has been shown to indicate muscle use during the activity. The noninvasive nature of magnetic resonance imaging appears to make it an ideal approach for studying the function of the complex neuromuscular system of the neck. METHODS. The extent of T2 increase was examined to gauge how intensely nine different neck muscles or muscle pairs were used in seven subjects. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation was assessed to infer the pattern of use among and within individual neck muscles or muscle pairs. RESULTS. Signal relaxation increased with exercise intensity for each head movement. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation also increased with exercise load. Neck muscles or muscle pairs extensively used to perform each head movement were: extension--semispinalis capitis and cervicis and splenius capitis; flexion--sternocleidomastoid and longus capitis and colli; rotation--splenius capitis, levator scapulae, scalenus, semispinalis capitis ipsilateral to the rotation, and sternocleidomastoid contralateral; and lateral flexion--sternocleidomastoid CONCLUSION. The results of this study, in part, agree with the purported functions of neck muscles derived from anatomic location. This also was true for the few selected muscles that have been examined in human electromyographic studies. Neck muscle function and morphology can be studied at a detailed level using exercise-induced shifts in magnetic resonance images.

NASA Program Space Physiology and Countermeasures

Neck afferent involvement in cardiovascular control during movement

It is well established that labyrinth and neck afferent information contributes to the regulation of somatomotor function during movement and changes in posture. There is also convincing evidence that the vestibular system participates in the modulation of sympathetic outflow and cardiovascular function during changes in posture, presumably to prevent orthostatic hypotension. However, the labyrinth organs do not provide any signals concerning body movements with respect to the head. In contrast, the neck receptors, particularly muscle spindles, are well located and suited to provide information about changes in body position with respect to the head and vestibular signals. Studies in the cat suggest that neck afferent information may modulate the vestibulosympathetic reflex responses to head-neck movements. There is some evidence in the cat to suggest involvement of low threshold mechanoreceptors. However, human studies do not indicate that low threshold mechanoreceptors in the neck modulate cardiovascular responses. The human studies are consistent with the studies in the cat in that they demonstrate the importance of otolith activation in mediating cardiovascular and sympathetic responses to changes in posture. This paper briefly reviews the current experimental evidence concerning the involvement of neck afferent information in the modulation of cardiovascular control during movement and changes in posture.

Review

Antigraviceptive neck muscle responses to "moving up and moving down" in human

The responses of neck muscle to sudden transit from one 'g' to hyper 'g', work to support the head and remain the relative position of head on trunk as common observed: i.e. in sudden acceleration or deceleration by car or ejection of pilot from aircraft. Accordingly it is highly possible that the neck muscle responses to moving up may be important to prevent the neck injury due to sudden linear acceleration such as moving up against gravity. However little is known about the evaluation of mechanism of this reflex. Therefore the present study was conducted with two aims. The first aim was to investigate the neck muscle responses to vertical linear acceleration bv 0.4 g produced with an electro-hydraulic servo-system. We chose the vertical linear acceleration because it activates mainly sacculus, from which afferents have been demonstrated to be connected directly to sternocleidomastoid muscle in animals and human. The second aim was to determine whether there is a difference of neck muscle response to moving down and moving up.

Vestibule/physiology

Comparison of sympathetic nerve responses to neck and forearm isometric exercise

PURPOSE: Although the autonomic and cardiovascular responses to arm and leg exercise have been studied, the sympathetic adjustments to exercise of the neck have not. The purpose of the present study was twofold: 1) to determine sympathetic and cardiovascular responses to isometric contractions of the neck extensors and 2) to compare sympathetic and cardiovascular responses to isometric exercise of the neck and forearm. METHODS: Muscle sympathetic nerve activity (MSNA), mean arterial pressure (MAP), and heart rate were measured in nine healthy subjects while performing isometric neck extension (INE) and isometric handgrip (IHG) in the prone position. After a 3-min baseline period, subjects performed three intensities of INE for 2.5 min each: 1) unloaded (supporting head alone), 2) 10% maximal voluntary contraction (MVC), and 3) 30% MVC, then subjects performed two intensities (10% and 30% MVC) of IHG for 2.5 min. RESULTS: Supporting the head by itself did not significantly change any of the variables. During [NE, MAP significantly increased by 10 +/- 2 and 31 +/- 4 mm Hg and MSNA increased by 67 +/- 46 and 168 +/- 36 units/30 s for 10% and 30% MVC, respectively. IHG and INE evoked similar responses at 10% MVC, but IHG elicited higher peak MAP and MSNA at 30% MVC (37 +/- 7 mm Hg (P < 0.05) and 300 +/- 48 units/30 s (P < 0.01) for IHG, respectively). CONCLUSIONS: The data indicate that INE can elicit marked increases in MSNA and cardiovascular responses but that it evokes lower peak responses as compared to IHG. We speculate that possible differences in muscle fiber type composition, muscle mass, and/or muscle architecture of the neck and forearm are responsible for these differences in peak responses.

NASA Discipline Neuroscience

Physiologic and thermal responses of male and female patients with multiple sclerosis to head and neck cooling

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the thermal and physiologic responses of patients with multiple sclerosis to short-term maximal head and neck cooling. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 24 female and 26 male patients with multiple sclerosis in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 degrees C), were cooled for 30 min by the liquid cooling garment, which was operated at its maximum cooling capacity. Oral, right, and left ear temperatures and cooling system parameters were logged manually every 5 min. Forearm, calf, chest, and rectal temperatures, heart rate, and respiration rate were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. This protocol was performed during the winter and summer to investigate the seasonal differences in the way patients with multiple sclerosis respond to head and neck cooling. No significant differences were found between the male and female subject group's mean rectal or oral temperature responses during any phase of the experiment. The mean oral temperature decreased significantly (P < 0.05) for both groups approximately 0.3 degrees C after 30 min of cooling and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 15 min after removal of the cooling helmet. The mean rectal temperatures decreased significantly (P < 0.05) in both male and female subjects in the winter studies (approximately 0.2-0.3 degrees C) and for the male subjects during the summer test (approximately 0.2 degrees C). However, the rectal temperature of the female subjects did not change significantly during any phase of the summer test. These data indicate that head and neck cooling may, in general, be used to reduce the oral and body temperatures of both male and female patients with multiple sclerosis by the approximate amount needed for symptomatic relief as shown by other researchers. However, thermal response of patients with multiple sclerosis may be affected by gender and seasonal factors, which should be considered in the use of liquid cooling therapy.

NASA Discipline Environmental Health

Characterizing Fit Factor of a One Size Fits-Most Emergency Mask using Subjects with Smaller Neck Circumferences

The Emergency Mask (EM) is an integral part of fire response on ISS, Orion and Gateway. The EM is a hood type protection respirator sealing around the subject’s neck, with an additional nose cup covering the subject’s oral nasal region. When integrated with a pair of Fire Cartridges (FCs), this system can be used to provide safe breathing air in a post-fire environment. The initial EM was certified as a ‘one size fits most’, however a recent requirements scrub discovered that the neck circumferences of the smallest possible crew population were not included in the initial requirement set. The test described in this paper uses the same slightly modified industry standard respirator test called a ‘Fit Factor’ used to certify the existing EM for larger subjects. Tests were performed on eight test subjects with neck circumference smaller than the initial EM requirement to determine if the current EM provided adequate protection during post-fire scenarios. The test included subjects donning an EM and then performing a number of head movements in a tent filled with approximately 50,000 particles/cm3 of smoke particulate. During these motions, particulate measurements were obtained from within the EM and compared with particulate measurements in the surrounding environment to determine the protection the EM provided in a simulated post-fire environment. This paper provides descriptions of the test hardware, methodology and results, which have provided rationale to design and build an EM to accommodate subjects with smaller necks.

Respirator

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC

The head and neck discomfort of autonomic failure: an unrecognized aetiology of headache

Information concerning the frequency, severity, character, location, duration, diurnal pattern of headache and ancillary symptoms were obtained in 25 patients with autonomic failure and 44 control subjects. Precipitating and ameliorating factors were identified. Autonomic failure patients had more head and neck discomfort than controls. Their discomfort was much more likely to localize in the occiput, nape of the neck and shoulder, compared with controls. There was a greater tendency for the discomfort to occur in the morning and after meals. It was sometimes less than 5 min in duration and was often associated with dimming, blurring, or tunnelling of vision. It was provoked by upright posture and relieved by lying down. Patients with severe autonomic failure and orthostatic hypotension often present with a posture-dependent headache or neck pain. Because the relationship of these symptoms to posture is often not recognized, the fact that these findings may signal an underlying autonomic disorder is underappreciated, and the opportunity to consider this aetiology for the headache may be missed.

NASA Discipline Regulatory Physiology

Neck Rupture and Scission Neutrons in Nuclear Fission

Just before a nucleus undergoes fission, a neck is formed between the emerging fission fragments. It is widely accepted that this neck undergoes a rather violent rupture, despite the absence of unambiguous experimental evidence. The main difficulty in addressing the neck rupture and saddle-to-scission stages of fission is that both are highly nonequilibrium processes. Here, we present the first fully microscopic characterization of the scission mechanism, along with the spectrum and the spatial distribution of scission neutrons (SNs), and some upper limit estimates for the emission of charged particles. The spectrum of SNs has a distinct angular distribution, with neutrons emitted in roughly equal numbers in the equatorial plane and along the fission axis. They carry an average energy around 3±0.5 MeV for the fission of 236 U, 240 Pu, and 252 Cf, and a maximum of 16–18 MeV. We estimate a conservative lower bound of 9%–14% of the total emitted neutrons are produced at scission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Effect of neck warming and cooling on thermal comfort

The potential use of local neck cooling in an area superficial to the cerebral arteries was evaluated by circulating cold or hot water through two copper disks held firmly against the neck. Subjective responses indicated that neck cooling improves the thermal comfort in a hot environment.

Williams, B. A.

Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

Begin, R.

Rheoencephalographic (REG) Assessment of Head and Neck Cooling for use with Multiple Sclerosis Patients

We have prepared a computer program (RHEOSYS:RHEOencephalographic impedance trace scanning SyStem) that can be used to automate the analysis of segmental impedance blood flow waveforms. This program was developed to assist in the post test analysis of recorded impedance traces from multiple segments of the body. It incorporates many of the blood flow, segmental volume, and vascular state indices reported in the world literature. As it is currently programmed, seven points are selected from each blood flow pulse and associated ECG waveforrn: 1. peak of the first ECG QRS complex, 2. start of systolic slope on the blood flow trace, 3. maximum amplitude of the impedance pulse, 4. position of the dicrotic notch, 5. maximum amplitude of the postdicrotic segment, 6. peak of the second ECG QRS complex, and 7. start of the next blood flow pulse. These points we used to calculate various geometric, area, and time-related values associated with the impedance pulse morphology. RHEOSYS then calculates a series of 34 impedance and cardiac cycle parameters which include pulse amplitudes; areas; pulse propagation times; cardiac cycle times; and various measures of arterial and various tone, contractility, and pulse volume. We used this program to calculate the scalp and intracranial blood flow responses to head and neck cooling as it may be applied to lower the body temperatures of multiple sclerosis patients. Twelve women and twelve men were tested using a commercially available head and neck cooling system operated at its maximum cooling capacity for a period of 30 minutes. Head and neck cooling produced a transient change in scalp blood flow and a significant, (P<0.05) decrease of approx. 30% in intracranial blood flow. Results of this experiment will illustrate how REG and RHEOSYS can be used in biomedical applications.

Montogomery, Leslie D.

Haemodynamic changes during neck pressure and suction in seated and supine positions

We sought to quantify the contribution of cardiac output (Q) and total vascular conductance (TVC) to carotid baroreflex-mediated changes in mean arterial pressure (MAP) in the upright seated and supine positions. Acute changes in carotid sinus transmural pressure were evoked using brief 5 s pulses of neck pressure and neck suction (NP/NS) via a simplified paired neck chamber that was developed to enable beat-to-beat measurements of stroke volume using pulse-doppler ultrasound. Percentage contributions of Q and TVC were achieved by calculating the predicted change in MAP during carotid baroreflex stimulation if only the individual changes in Q or TVC occurred and all other parameters remained at control values. All NP and NS stimuli from +40 to -80 Torr (+5.33 to -10.67 kPa) induced significant changes in Q and TVC in both the upright seated and supine positions (P < 0.001). Cardiopulmonary baroreceptor loading with the supine position appeared to cause a greater reliance on carotid baroreflex-mediated changes in Q. Nevertheless, in both the seated and supine positions the changes in MAP were primarily mediated by alterations in TVC (percentage contribution of TVC at the time-of-peak MAP, seated 95 +/- 13, supine 76 +/- 17 %). These data indicate that alterations in vasomotor activity are the primary means by which the carotid baroreflex regulates blood pressure during acute changes in carotid sinus transmural pressure.

Clinical Trial

Numerical Modeling of Extensional Necking Instabilities: Application to Ganymede's Grooved Terrain

Ganymede s pervasive 5-10 km-wavelength grooves have been suggested to result from a necking instability during an epoch of lithospheric extension, but to date few quantitative studies of groove formation have been performed. We present two-dimensional numerical models of necking instabilities under conditions that are appropriate to Ganymede at the time of groove formation. Preliminary simulations indicate that extensional necking instabilities can occur under a range of conditions, many of which may be relevant to Ganymede. The form of the surface topography produced by these instabilities varies as a function of the strain rate, amount of extension, initial topographic perturbation, and rheological parameters.

Bland, M. T.

Flow visualization in long neck Helmholtz resonators with grazing flow

Both oscillating and steady flows were applied to a single plexiglass resonator cavity with colored dyes injected in both the orifice and grazing flow field to record the motion of the fluid. For oscillatory flow, the instantaneous dye streamlines were similar for both the short and long-neck orifices. The orifice flow blockage appears to be independent of orifice length for a fixed amplitude of flow oscillation and magnitude of the grazing flow. The steady flow dye studies showed that the acoustic and steady flow resistances do not necessarily correspond for long neck orifices.

Baumeister, K. J.

Flow visualization in long neck Helmholtz resonators with grazing flow

Both oscillating and steady flows were applied to a single plexiglass resonator cavity with colored dyes injected in both the orifice and grazing flow field to record the motion of the fluid. For oscillatory flow, the instantaneous dye streamlines were similar for both the short and long-neck orifices. The orifice flow blockage appears to be independent of orifice length for a fixed amplitude of flow oscillation and magnitude of the grazing flow. The steady flow dye studies showed that the acoustic and steady flow resistances do not necessarily correspond for long neck orifices.

Baumeister, K. J.