Experimental database of two-phase natural circulation with local measurements
Not provided.
Transition from molecular diffusion to natural circulation mode air-ingress in high temperature helium loop
Not provided.
Impact of dissolved salts on two-phase flow and boiling heat transfer in a natural circulation loop
Two-phase natural circulation and boiling experiments are conducted in this study with artificial seawater as a heat transfer fluid or process coolant. This experimental work is focused on understanding the role of dissolved salts in water on the steady state two-phase natural circulation flow rates. Mass flow rates were measured at different heat flux levels with artificial seawater, deionized water and tap water in the experimental loop. It was found that the average quasi-steady state mass flow rates were the same at any particular heat flux level regardless of the fluid being used. Artificial seawater coolant exhibited more stable natural circulation at higher heat flux as compared to the other two coolants. Mass flow measurements recorded at 2 s intervals show that magnitude of flow oscillations are much higher in case of tap water and deionized water. Also, high speed camera images revealed that the bubble departure diameters are smaller in seawater compared to tap or deionized water. This can be attributed to the increased local wettability due to the presence of dissolved salts in the fluid. Visual observations of the riser section showed that bubble coalescence and formation of slugs is inhibited in the seawater. These observations also explain the reduced pressure drop across test section when seawater was used as a coolant.
Numerical simulation of losses along a natural circulation helium loop
A natural circulation helium loop appears to be a perspective passive method of a nuclear reactor cooling. When designing this device, it is important to analyze the mechanism of an internal flow. The flow of helium in the loop is set in motion due to a difference of hydrostatic pressures between cold and hot branch. Steady flow at a requested flow rate occurs when the buoyancy force is adjusted to resistances against the flow. Considering the fact that the buoyancy force is proportional to a difference of temperatures in both branches, it is important to estimate the losses correctly in the process of design. The paper deals with the calculation of losses in branches of the natural circulation helium loop by methods of CFD. The results of calculations are an important basis for the hydraulic design of both exchangers (heater and cooler). The analysis was carried out for the existing model of a helium loop of the height 10 m and nominal heat power 250 kW.
Experimental Investigation of Forced Convection and Natural Circulation Cooling of a VHTR Core under Normal Operation and Accident Scenarios
This NEUP project #15-8205 entitled “Experimental Investigation of Forced Convection and Natural Circulation Cooling of a VHTR Core under Normal Operation and Accident Scenarios”, has investigated important phenomena in the safety of Very High Temperature Reactors (VHTRs) using the experimental facilities at City College of New York (CCNY) and Kansas State University (KSU), in collaboration with the Idaho State University (ISU) and Idaho National Laboratory (INL). The main objectives of this project were to investigate the forced convection and bypass flow phenomena, natural circulation flow and heat transfer, and graphite oxidation due to air ingress which could occur in a Very High Temperature Reactor (VHTR) with a prismatic core. High pressure/high temperature experiments have been conducted to obtain data that could be used for validation of VHTR design and safety analysis codes. The focus of these experiments was on the generation of benchmark data for design and off-design heat transfer for forced and natural circulation in a VHTR core. This work has built on the previous NEUP project #11-3218 which investigated forced convection and flow laminarization phenomena in a prismatic core of a VHTR and natural circulation of a pure gas under Pressurized Conduction Cooldown (PCC) and Depressurized Conduction Cooldown (DCC) conditions. Under each Task, extensive literature reviews on natural circulation, bypass flow, air ingress and graphite oxidation phenomena were conducted. In Task 1, scaling analyses were conducted by Idaho State University followed by design and construction of experimental facilities needed to conduct both bypass flow and natural circulation experiments at CCNY. Natural circulation experiments were conducted in Task 2 to investigate the air ingress phenomena, and bypass flow phenomena in Task 3, both at CCNY. In Task 4, radiation heat transfer and graphite oxidation tests were performed at Kansas State University. The experimental data were then analyzed to obtain quantitative results on natural circulation of pure gases and gas mixtures under DCC conditions, bypass flow rates, radiation heat transfer and graphite oxidation. In addition, CFD and Direct Numerical Simulations were conducted by INL and CCNY to investigate the flow laminarization phenomenon in strongly heated gas flows. The scaling analyses have shown that the key nondimensional numbers and parameters all have acceptable distortion levels principally because the CCNY facility’s test sections have representative cooling channel dimensions and are using either helium or a scalable gas such as nitrogen at representative state conditions. The natural circulation experiments involving helium and nitrogen gas mixtures at CCNY have elucidated the effect of nitrogen (simulating air) ingress into a lower plenum on the onset of natural circulation, mass flow rates and heat transfer coefficients under different power input levels in the riser section. Also, the transport of nitrogen from the lower plenum to upper plenum due to natural circulation was quantified for the first time. Nusselt number correlations for the heat transfer coefficient under natural circulation as a function of Reynolds and Prandtl numbers was also developed. The experiments at KSU revealed that prior to the onset of natural circulationin a VHTR core. This work has built on the previous NEUP project #11-3218 which investigated forced convection and flow laminarization phenomena in a prismatic core of a VHTR and natural circulation of a pure gas under Pressurized Conduction Cooldown (PCC) and Depressurized Conduction Cooldown (DCC) conditions. Under each Task, extensive literature reviews on natural circulation, bypass flow, air ingress and graphite oxidation phenomena were conducted. In Task 1, scaling analyses were conducted by Idaho State University followed by design and construction of experimental facilities needed to conduct both bypass flow and natural circulation experiments at CCNY. Natural circulation experiments were conducted in Task 2 to investigate the air ingress phenomena, and bypass flow phenomena in Task 3, both at CCNY. In Task 4, radiation heat transfer and graphite oxidation tests were performed at Kansas State University. The experimental data were then analyzed to obtain quantitative results on natural circulation of pure gases and gas mixtures under DCC conditions, bypass flow rates, radiation heat transfer and graphite oxidation. In addition, CFD and Direct Numerical Simulations were conducted by INL and CCNY to investigate the flow laminarization phenomenon in strongly heated gas flows. The scaling analyses have shown that the key nondimensional numbers and parameters all have acceptable distortion levels principally because the CCNY facility’s test sections have representative cooling channel dimensions and are using either helium or a scalable gas such as nitrogen at representative state conditions.The natural circulation experiments involving helium and nitrogen gas mixtures at CCNY have elucidated the effect of nitrogen (simulating air) ingress into a lower plenum on the onset of natural circulation, mass flow rates and heat transfer coefficients under different power input levels in the riser section. Also, the transport of nitrogen from the lower plenum to upper plenum due to natural circulation was quantified for the first time. Nusselt number correlations for the heat transfer coefficient under natural circulation as a function of Reynolds and Prandtl numbers was also developed. The experiments at KSU revealed that prior to the onset of natural circulation(ONC), molecular diffusion plays a significant role in air-ingress, however, at higher temperatures convection currents may be influencing air ingress and in-turn ONC times. Bypass flow experiments faced difficulties in the measurement of gas velocity in the main channel due to the failure of a high temperature Hot Wire Anemometer probe, so an energy balance method was instead employed to estimate the flow distribution between the main and bypass flow channels. In the graphite oxidation experiments conducted at KSU, oxidation was found to increase the thermal diffusivity of nuclear grade graphite. This change is believed to be driven by oxidation decreasing graphite sample density rather than raising the thermal conductivity. Oxidation was also shown to greatly alter graphite emissivity. If large amounts of impurities have built up within the graphite over time and have significantly increased its effective ash content, then air ingress is likely to severely inhibit the radiative heat transfer abilities of the graphite due to the formation of low emissivity, ash layers on its surface. However, if the purity of the graphite at the time of the air ingress is still close to that of its virgin specifications, the oxidation induced roughening of the graphite’s outer surface would have the effect of slightly raising its emissivity. The flow laminarization phenomenon was investigated by INL by examining the results of Direct Numerical Simulations of previous experiments, and by CCNY conducting its own DNS simulations using DOE’s Nek5000 code
Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors
The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.
Natural circulation FLiBe loop overview
A new large natural circulation FLiBe loop has operated for the first time in 40 years. Reaching temperatures above 700 C with stable flow rates around 5 cm/s, the loop exhibits a range of flow phenomena pertinent to high temperature natural circulation safety systems for nuclear reactors. This paper discusses the system and several operating conditions spanning a wide range of behavior to aid the development of other systems, simulation benchmarks, or system-codes. Analysis of heat transport phenomena indicates that standard Nusselt number correlations apply to a first approximation. More accurate salt-freezing models may be necessary for air-cooled salt-systems due to the insulating affect of the low thermal-conductivity frozen salt layer on the cold pipe walls.
Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows
New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.
Validation of SAS4A/SASSYS-1 for Steady-State Single-Phase Natural Circulation
The development of numerical software for engineering applications requires the validation of the code against experimental benchmark datasets. To support the validation of SAS4A/SASSYS-1 in simulating the single-phase natural circulation within nuclear reactor systems, high-precision steady-state experiments are performed to capture single-phase natural circulation phenomena on an existing scaled facility with comprehensive instrumentation. Forced convection tests are designed precisely capturing the facility’s critical thermal-hydraulic parameters required for one-dimensional modeling, and a comprehensive single-phase natural circulation dataset is obtained with well-documented experimental uncertainty and facility description. Analysis and discussion based on the finalized dataset confirm the dataset’s ability in capturing dominant phenomena and address important physical interpretation of parameters. The dataset reported in this project provides a valuable benchmark resource for the validation of system analysis codes under single-phase natural circulation inside nuclear reactors. Validation of SAS4A/SASSYS-1 is then performed against the obtained benchmark dataset to confirm the capability of its physics model in simulating the steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators to quantify and restrict numerical errors from discretization. Numerical uncertainty originating from finite maximum pseudo-transient time is also quantified and restricted. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, directly quantifying the simulation output in a Monte Carlo approach. The composition of the output uncertainty is further determined by the estimators of Sobol’ indices through a variance-based sensitivity analysis. With uncertainty quantified for each individual condition, detailed comparison between the simulation results and experimental data is performed covering the whole dataset, which shows consistent agreement for all important quantities. The validation activity reported in this project demonstrates that SAS4A/SASSYS-1 can predict the primary parameters with satisfactorily accuracy under steady-state single-phase natural circulation.
Native Natural circulation in VERA
This work seeks to introduce a native natural circulation solver to VERA's thermohydraulics capabilities. This work begins with initial investigations into the viability of such a solver by determining the fundamental equations as well as necessary inputs. The method was then implemented in the form of a Python script coupled to CTF which was compared to TRACE. Once viability of the natural circulation solver was established, it was then implemented natively in MPACT for use with previously created simplified thermohydraulics solvers. This new implementation of the native natural circulation solver in MPACT is then tested for single physics problems for both a BWR and PWR single channel model and compared to TRACE where it shows an error of about 30% for BWRs and about 15% for PWRs. The solver is additionally tested for NuScale based models where it demonstrates an error to the reported flow rate of about 10%, resulting in an eigenvalue error of only 138 pcm when comparing fixed flow rate multiphysics runs. Finally, the solver is tested in multiphysics systems for a small PWR assembly, a small BWR assembly, and a full core approximate model of the NuScale design. In these multiphysics runs, it demonstrates no impact on multiphysics convergence stability, as well as negligible impact on runtimes. (authors)
Validation of SAS4A/SASSYS-1 for predicting steady-state single-phase natural circulation
The validation of system analysis codes for nuclear reactor systems is required for the development and application of these computational tools. Designed as a comprehensive system analysis code for advanced nuclear reactors, SAS4A/SASSYS-1 requires validation of its physics model for capturing single-phase natural circulation behavior. To support the validation of SAS4A/SASSYS-1, high-precision experiments are performed capturing steady-state single-phase natural circulation on a scaled facility with comprehensive instrumentation. In this work, dedicated tests are performed quantifying the critical modeling parameters, and a single-phase natural circulation benchmark dataset is obtained with well-documented uncertainty and comprehensive facility description. The validation is then performed against the dataset examining the capability of SAS4A/SASSYS-1 in simulating steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators which quantify and restrict numerical errors from discretization. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, quantifying the output uncertainty in a Monte Carlo approach. The composition of the output uncertainty is also quantified through a variance-based sensitivity analysis. With the uncertainty quantified for each individual condition, a detailed comparison between the simulation results and experimental data is performed covering the whole dataset. The results show consistent agreement for all primary parameters. The current validation activity provides a valuable benchmark dataset for the validation of system analysis codes in capturing single-phase natural circulation and demonstrates satisfactory prediction capability of SAS4A/SASSYS1 for steady-state single-phase natural circulation.
Natural circulation flow distribution within a multi-branch manifold
Currently, natural circulation systems are extensively used in different applications but they need to be fully characterized to understand their behavior under different boundary conditions. CFD tools provide means to analyze these systems, yet, they need additional experimental data to be validated. Experimental measurements of the flow distribution within a multiple-branch manifold under natural circulation have been conducted using PIV. Measurements have demonstrated that the flow within the risers behave similarly, differing between 6.68% and 12.63% in speed and vertical velocity, and between 8.7% and 17.5% for vertical turbulence strength at selected heights. A back-flow region has been observed at the bottom of the main channel, with an increasing cross sectional area moving far from the manifold inlet, while stream-wise flow occupies the top section of the main channel. The experimental activity has also produced a complete experimental data set with first and second order statistics of the flow that can be used for CFD code validation.
Large-scale Multiphysics Simulations of Small Modular Reactors Operating in Natural Circulation
Thanks to the advancements in high-performance computing, advanced modeling and simulation have become crucial in driving the development and deployment of next-generation nuclear reactors, such as small modular reactors (SMRs). SMRs offer the promise of cost-effective baseload electricity production and improved safety, while addressing some of the challenges associated with large reactor designs, such as high capital costs and extended construction timelines. As part of the Exascale Computing Project, the large-scale multiphysics simulation of an entire SMR primary system has been achieved by combining computational fluid dynamics and neutronics. In addition to the successful demonstration of full-core SMR simulations, the current study integrated the impact of natural circulation into the system. Natural circulation is the primary mechanism driving coolant circulation in SMRs. The mass flow rate in the core depends on the core power, and a numerical model has been developed to predict it. The pressure drop caused by the helical coil steam generator was also accounted for by developing a pressure drop correlation based on high-fidelity large eddy simulation results, further improving prediction accuracy. In conclusion, the results of the study demonstrate that the implemented natural circulation model is effective in predicting the responses of SMR full-core multiphysics simulations.
Ambient and building condition effects modeling of air-cooled natural circulation systems
Throughout the testing program at Natural convection Shutdown heat removal Test Facility (NSTF), strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under identical test procedures. Significant analysis efforts were conducted to gain understanding of these influences, and quantify the system response of the test facility. In this paper, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions, including wind and temperatures. Coefficients in the model were determined based on best fitting of the experimental data set. The predictive capability of the empirical model was demonstrated by applying it to new sets of experimental data. Finally, after implementing the empirical model in both system-level thermal fluids and computational fluid dynamics modeling of the facility, simulations from both approaches resulted in accurate predictions in system natural circulation flow rates.
Numerical study of air ingress transition to natural circulation in a high temperature helium loop
Here, the generation-IV high temperature gas cooled reactors (HTGRs) are designed with many passive safety features, one of which is the ability to passively remove heat under a loss of coolant accident (LOCA). However, several common reactor designs do not prevent against a large break in the coolant system and may therefore experience a depressurized LOCA. This would lead to air entering into the reactor system via several potential modes of ingress: diffusion, gravity currents, and natural circulation. At the onset of a LOCA, the initial rate of air ingress is expected to be very slow because it is governed by molecular diffusion. However, after several hours, natural circulation would commence, thus, bringing the air into the reactor system at a much higher rate. As a consequence, air ingress would cause the high temperature graphite matrix to oxidize, leading to its thermal degradation and decreased passive heat (decay) removal capability. Therefore, it is essential to understand the transition of air ingress from molecular diffusion to natural circulation in an HTGR system. This paper presents results from a computational fluid dynamics (CFD) model to study the air ingress transition behavior. These results are validated against an h-shaped high temperature helium loop experiment. Details are provided to quantitatively predict the transition time from molecular diffusion to natural circulation.
Natural circulation loop using liquid nitrogen for cryo-detection system
The natural circulation loop is designed for the cryogenic insert in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Sensitivity is the key parameter of a FTICR mass spectrometer and the cryo-cooling of the pre-amplifier can reduce the thermal noise level and thereby improve the signal-to-noise ratio. The pre-amplifier consisted of non-magnetic materials is thermally connected to the cooling loop which is passing through the flange maintaining ultra-high vacuum in the ion cell. The liquid nitrogen passes through inside of the loop to cool the pre-amplifier indirectly. At the end, a cryocooler is located to re-condense nitrogen vapor generated due to the heat from the pre-amplifier. The circulating fluid removes heat from the pre-amplifier and transports it to the cryocooler or heat sink. In this paper the natural circulation loop for cryogenic pre-amplifier is introduced for improving the sensitivity of cryo-detector. In addition, the initial cool-down of the system by a cryocooler is presented and the temperature of the radiation shield is discussed with respect to the thickness of shield and the thermal radiation load.
Single-phase, natural circulation annular flow measurements for cartridge loop irradiation experiments
The nuclear industry is increasingly considering cartridge-style experiments for irradiation testing of advanced reactor fuels and materials under flowing conditions. Cartridge loops do not require the extensive support infrastructure that are necessary for external flow loops and minimize the possibility of coolant solidification over the long distance from the reactor to the external facilities. However, there is a general lack of quality flow data for internally heated fluids in an annular configuration representative of a cartridge-type irradiation experiment, particularly one with natural circulation. To address this data need, a series of experiments was conducted to measure the natural circulation flow rates of pressurized water in a sealed, internally heated vessel with annular flow conditions that represent a molten salt or sodium cartridge loop. Temperatures and flow rates were measured under steady-state and transient conditions. Here, this paper describes the facility, methods, and results of the experiments, including the determination of nondimensional parameters. A simple 1D model of the natural convection flow rates agrees well with the experimental results. Applying this model to simulate a liquid salt cartridge experiment predicts that natural circulation flow might be able to provide liquid salt Reynolds numbers similar to those of some molten salt reactor concepts at relevant power densities.