Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NaI(Tl)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DX-like centers in NaI:Tl upon aliovalent codoping

Aliovalent doping has been recently shown to remarkably improve energy resolution in some halide scintillators. Based on first-principles calculations we report on the formation of DX-like centers in a well-known scintillator material, Tl-doped NaI (NaI:Tl), when codoped with Ca or Ba. Our calculations indicate a net binding energy favoring formation of the defect complex (Tl{sub Na}{sup −}+Ca{sub Na}{sup +}) involving a new cation-cation bond, instead of the isolated substitutional defects. The pair has properties of a deep DX-like acceptor complex. Doping with the aliovalent anion impurity Te is also found to induce deep centers, which can act as effective electron or hole traps. The hole trapped as Te{sub I}{sup 0} involves large lattice relaxation of the Te and an adjacent iodine, consistent with extrinsic self-trapping of the hole. Thus, in contrast to the positive effect achieved by aliovalent co-doping of the rare-earth tri-halides LaBr{sub 3}:Ce and CeBr{sub 3}:Ca as reported recently, co-doping with donor-like cations Ca, Ba, or the acceptor-like anion Te in monovalent NaI:Tl is found to inhibit scintillation response.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Background studies for NaI(Tl) detectors in the ANAIS dark matter project

Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of {sup 238}U and {sup 232}Th, and {sup 40}K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for {sup 40}K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The {sup 40}K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and {sup 40}K activity at a level ten times lower than in ANAIS-0 has been determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a new rectangular NaI(Tl) scintillator and spectroscopy of low-energy charged particles

Standard NaI(Tl) scintillators have only one optical window and are housed in airtight protective enclosures to protect against hygroscopicity from moisture in the air. For these reasons, NaI(Tl) scintillators are unsuitable for the collection of scintillation photons or for the detection of low-energy (<1 MeV) charged particles. To overcome these disadvantages, a rectangular NaI(Tl) scintillator has been newly developed. In this paper, we estimate the photon response of this new scintillator. The energy resolution was {Delta}E (Full Width at Half Maximum)=7.5{+-}0.2% for 662 keV gamma rays from a {sup 137}Cs standard source. The number of photoelectrons was 3,686 for the photoelectric peak. Good energy resolution and photon collection were therefore confirmed for this specialized form of NaI(Tl) scintillator. The ability of this scintillator to detect low-energy particles was confirmed by successful measurement of low-energy charged particles (250-700 keV region) from a {sup 137}Cs thin film radioisotope source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Serrated flow in $\mathrm{NaI:Tl}$ scintillator crystals

We report the serrated-flow behavior is an important phenomenon that unveils material-deformation mechanisms, as reported for various kinds of materials. NaI doped with Tl (NaI:Tl) is unique among scintillation materials in that the structure contains glide planes that are linked to serration behavior. In the present work, single crystals of NaI:Tl were subjected to room-temperature compression experiments at different strain rates. The serrated flow was observed, and complexity and multifractal analyses were performed to analyze the serration behavior. The findings revealed that the strain rate had a pronounced effect on the complexity and multifractality of the serrated flow, similar to what has been found in other alloy systems. The results also indicate that there may be a strong link between the complexity of the serrated flow behavior and the heterogeneity of the underlying dynamics. It is expected that the present work could be a step toward a better understanding of the deformation behavior and forgeability of NaI:Tl single crystals.

36 MATERIALS SCIENCE↗

Comparison of CeBr3 with LaBr3:Ce, LaCl3:Ce, and NaI:Tl Detectors

Energy resolution and detection efficiency were compared between two sizes of cerium bromide (CeBr3) scintillators, three sizes of lanthanum bromide (LaBr3:Ce) scintillators, three sizes of sodium iodide (NaI:Tl) scintillators, and a lanthanum chloride (LaCl3:Ce) scintillator. Comparisons are made of key parameters such as energy resolution, detection efficiency, linearity, and self-activity of CeBr3, LaBr3:Ce, LaCl3:Ce, and NaI:Tl scintillator detectors. The scintillator detectors are tested by comparing the peak separation and identification in the energy range up to 3.0 MeV using 133Ba, 152Eu, and naturally occurring radioactive materials [1]. The study has shown that CeBr3 scintillator detectors provided by Saint-Gobain offer better resolution than NaI:Tl scintillator detectors. CeBr3 detectors could resolve some closely spaced peaks from 133Ba and 152Eu, which NaI:Tl could not. LaBr3:Ce has slightly better resolution, and a slightly higher efficiency than CeBr3. In this work, “self-activity” of each of these four detector types was measured by operating the detectors themselves. A comparison of the intrinsic activity for all of the detectors in this study is demonstrated. For CeBr3, the self-activity present may be reduced, or even eliminated in the future, through improved processes for growing the material. It will be discussed if, and under what conditions, CeBr3 may be better than LaBr3:Ce and LaCl3:Ce for detection of certain special nuclear material γ-rays [2]. An overall advantage of CeBr3 detectors over lanthanum halide and NaI:Tl detectors will be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Digital pulse processing for NaI(Tl) detectors

We apply two different post-processing techniques to digital pulses induced by photons in a NaI(Tl) detector and compare the obtained energy resolution to the standard analog approach. Our digital acquisition approach is performed using a single-stage acquisition with a fast digitizer. Both the post-processing techniques we propose rely on signal integration. In the first, the pulse integral is calculated by directly numerically integrating the pulse digital samples, while in the second the pulse integral is estimated by a model-based fitting of the pulse. Our study used a 7.62 cm×7.62 cm cylindrical NaI(Tl) detector that gave a 7.60% energy resolution (at 662 keV), using the standard analog acquisition approach, based on a pulse shaping amplifier. The new direct numerical integration yielded a 6.52% energy resolution. The fitting approach yielded a 6.55% energy resolution, and, although computationally heavier than numerical integration, is preferable when only the early samples of the pulse are available. We also evaluated the timing performance of a fast–slow detection system, encompassing an EJ-309 and a NaI(Tl) scintillator. Here, we use two techniques to determine the pulse start time: constant fraction discrimination (CFD) and adaptive noise threshold timing (ANT), for both the analog and digital acquisition approach. With the analog acquisition approach, we found a system time resolution of 5.8 ns and 7.3 ns, using the constant fraction discrimination and adaptive noise threshold timing, respectively. With the digital acquisition approach, a time resolution of 1.2 ns was achieved using the ANT method and 3.3 ns using CFD at 50% of the maximum, to select the pulse start time. Finally, the proposed direct digital readout and post-processing techniques can improve the application of NaI(Tl) detectors, traditionally considered ‘slow’, for fast counting and correlation measurements, while maintaining a good measurement of the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTOR

Abstract Gamma spectrum measured by an NaI(Tl) detector is known to be unstable with the in situ temperature. In the present work, an advanced method has been applied to stabilize the gamma spectrum measured by the NaI(Tl) detector at environmental radiation monitoring (ERM) stations. The method is based on experimental data obtained under controlled conditions in laboratory. In the temperature range from 4 to 45°C, the relative deviation of the peak positions within the stabilized gamma spectrum is less than 2%. To test this method in a real scenario, it has been integrated into the ERM station at the Military Institute of Chemical and Environmental Engineering in Hanoi, Vietnam. The results show that the proposed method is ready for a real application.

Hung, Dinh Tien↗

NaI (Tl) calorimeter calibration and simulation for Coulomb sum rule experiment in Hall-A at Jefferson Lab

A precision measurment of inclusive electron scattering cross sections is carried out at Jefferson Lab in the quasi-elastic region for 4 He, 12 C, 56 Fe and 208 Pb targets. The longitudinal (R L ) and transverse (R T ) response functions of the nucleon need to be extracted precisely in the momentum transfer range 0.55 GeV/c ≤ |q| ≤ 1.0 GeV/c. To achieve the above goal, a NaI (Tl) calorimeter is used to distinguish good electrons from background, including pions and low energy electrons rescattered from the walls of the spectrometer magnets. Due to a large set of kinematics and changes in HV settings, a number of calibrations are performed for the NaI (Tl) detector. Corrections for a few blocks of NaI (Tl) with bad or no signal are applied. The resolution of the NaI (Tl) detector after calibration reached ɤE/√E ≈ 3% at E = 1 GeV. The performance of the NaI (Tl) detector is compared with a simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production and suppression of delayed light in NaI(Tl) scintillators

Here we investigate a hypothesis that energy accumulation and the subsequent release in NaI(Tl) may lead to pulselike events in the few-keV energy regime, a phenomenon suggested by the crystal manufacturing company Saint-Gobain, who provided the crystals for DAMA/LIBRA. While we observed delayed long-lasting (days) light emission in a 3-inch NaI(Tl) crystal after exposing it to UV light, the delayed light consists primarily of single photons that are uncorrelated with each other. We also observe delayed light emission in NaI(Tl) following gamma radiation and large ionization events like cosmic-ray muons. We found that irradiating the crystal with red light after UV exposure significantly suppressed delayed photon emissions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies but fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Size Effect on Nuclear Gamma-Ray Energy Spectra Acquired by Different Sized CeBr3, LaBr3:Ce, and NaI:Tl Gamma-Ray Detectors

Gamma-ray energy spectra were acquired for different sizes of cerium tribromide (CeBr3), cerium-doped lanthanum tribromide (LaBr3:Ce), and thallium-doped sodium iodide (NaI:Tl) detectors. A comparison was conducted of the energy resolution and detection efficiency of these scintillator detectors for different sizes of detectors. The results of this study are consistent with the observation that for each size detector, LaBr3:Ce offers better resolution than either a CeBr3 or NaI:Tl detector of the same size. In addition, CeBr3 and LaBr3:Ce detectors could resolve some closely spaced peaks in the spectra of several radioisotopes that NaI:Tl could not. As the detector size increased, all three detector materials exhibited higher efficiency, albeit with slightly reduced resolution. Significantly, the very low intrinsic activity of CeBr3 is also demonstrated in this study, which, when combined with energy resolution characteristics for a range of detector sizes, could lead to an improved ability to detect special nuclear materials compared to the other detectors.

actinium-227↗

First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17

In this study, the first search for a dark matter annual modulation signal with NaI(Tl) target material in the Southern Hemisphere conducted with the DM-Ice17 experiment is presented. DM-Ice17 consists of 17 kg of NaI(Tl) scintillating crystal under 2200 m.w.e. overburden of Antarctic glacial ice. The analysis presented here utilizes a 60.8 kg yr exposure. While unable to exclude the signal reported by DAMA/LIBRA, the DM-Ice17 data are consistent with no modulation in the energy range of 4-20 keV, providing the strongest limits on WIMP candidates from a direct detection experiment located in the Southern Hemisphere. Additionally, the successful deployment and stable operation of 17 kg of NaI(Tl) crystal over 3.5 years establishes the South Pole ice as a viable location for future underground, low-background experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

New detector array, the Modular Total Absorption Spectrometer (MTAS),was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab(ORNL).Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products.MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over1000 kg.The response of the central and other 18 MTAS modules to -radiation was simulated using the GEANT4 tool kit modified to analyze the nonlinear light output of NaI(Tl).A detailed description oftheGEANT4modifications madeisdiscussed.SimulatedenergyresolutionofMTAS modules is found to agree well with the measurements for single transitions of 662keV (137Cs) with 8.2% full width half maximum (FWHM),835keV (54Mn) with FWHM of 7.5% FWHM, and 1115keV (65Zn) with FWHM of 6.5%.Simulations of single and multiple -rays from 60Co are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency Calibration of 4{pi} NaI(Tl) Gamma-ray Detectors for Plane Sources - Paper 130

4{pi} NaI(Tl) detectors are useful for low level gamma activity measurements due to the near 4{pi} solid angle that can be obtained with them. An analytical theoretical approach is presented here to calculate the absolute efficiencies for this type of detectors. The approach depends on the accurate calculation of two important factors; the path length, d, the photon traverses within the active volume of a gamma detector, and the geometrical solid angle,{Omega}, subtended by the source to the detector at the point of entrance. These two factors are theoretically derived through a straightforward analytical approach. In this work, this model is extended to an isotropic radiating point source, and a thin circular disk source. The results of the present absolute efficiency values were compared with the experimental and M.C. method works reported in the literature. The present theoretical and the experimental efficiency values are in good agreement. The present approach offers a good method to calibrate 4{pi} NaI(Tl) detectors over a large energy range without the need for standard sources, as is the case for experimental methods, nor optimization of detector parameters as for Monte Carlo simulations. Discrepancies with experimental results are reduced to lower than 4%. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background model for the NaI(Tl) crystals in COSINE-100

The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2–6) keV energy interval. The dominant contributors in this energy region are found to be 210 Pb and 3 H.

36 MATERIALS SCIENCE↗

Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons

Nonproportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9-100 keV. Special attention is paid to the x-ray escape peaks. They provide us additional information about photon response in the range 0.9-12 keV. A rapid variation in the photon response curve is observed near the iodine K-electron binding energy. A dense sampling of data is performed around this energy and that data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curve of NaI:Tl down to energies as low as 30 eV. A comparison of our data with data of others employing different methods is made. Advantages, limitations, and peculiarities of presented techniques and methods are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗