At least 19 records

Coded-aperture imaging in nuclear medicine

Coded-aperture imaging is a technique for imaging sources that emit high-energy radiation. This type of imaging involves shadow casting and not reflection or refraction. High-energy sources exist in x ray and gamma-ray astronomy, nuclear reactor fuel-rod imaging, and nuclear medicine. Of these three areas nuclear medicine is perhaps the most challenging because of the limited amount of radiation available and because a three-dimensional source distribution is to be determined. In nuclear medicine a radioactive pharmaceutical is administered to a patient. The pharmaceutical is designed to be taken up by a particular organ of interest, and its distribution provides clinical information about the function of the organ, or the presence of lesions within the organ. This distribution is determined from spatial measurements of the radiation emitted by the radiopharmaceutical. The principles of imaging radiopharmaceutical distributions with coded apertures are reviewed. Included is a discussion of linear shift-variant projection operators and the associated inverse problem. A system developed at the University of Arizona in Tucson consisting of small modular gamma-ray cameras fitted with coded apertures is described.

Smith, Warren E.↗

The Medical Aspects of Space Flight Seen from the Viewpoint of Nuclear Medicine

Radionuclide volume measurements performed on crews of selected Apollo missions indicate the following: (1) Invariably, there is a small drop in red-cell mass of the returning crewmembers; (2) plasma-volume decreases similar to those experienced during bedrest are found in crewmen of short Gemini missions. After longer missions, the plasma-volume decrease is no longer present; (3) extracellular- and total-body water changes prove that spaceflight weight loss includes actual tissue losses; and (4) the loss of total-body exchangeable potassium after the Apollo 15 mission is evidence of increased aldosterone secretion.

Johnson, P. C.↗

Multiwire Gamma Camera for Radionuclide and Radiographic Imaging in the Space environment

Unique multiwire proportional counter technology has been developed at the Johnson Space Center over the past several years. The technology will be described and how it may apply both in near- and long-term NASA efforts. In the near-term, I feel that the technology will provide a significant tool for the cardiovascular research area. In particular, low-dose nuclear medicine and tissue densitometry techniques of expanded scope will be supplied. In the longer term, the multiwire technique can provide a general purpose radiology and nuclear medicine facility for use in the space station which would be difficult and costly to provide by other means.

Lacy, Jeffrey L.↗

1986 Nuclear Science Symposium, 33rd, and 1986 Symposium on Nuclear Power Systems, 18th, Washington, DC, Oct. 29-31, 1986, Proceedings

Papers are presented on space, low-energy physics, and general nuclear science instrumentations. Topics discussed include data acquisition systems and circuits, nuclear medicine imaging and tomography, and nuclear radiation detectors. Consideration is given to high-energy physics instrumentation, reactor systems and safeguards, health physics instrumentation, and nuclear power systems.

Stubblefield, F. W.↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Improved Gamma-and X-Ray Pinhole Camera

Electronic additions increase image quality. Digital image-processing equipment electronically performs functions of S1 and D2 improving resolution and adding capability for image storage and further processing. System useful in nuclear medicine or radioisotope imaging, tomography and nuclear industry.

Yin, L. I.↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

Nuclear Science Symposium, 25th, and Symposium on Nuclear Power Systems, 10th, Washington, D.C., October 18-20, 1978, Proceedings

Detectors of various types are discussed, taking into account drift chambers, calorimetry, multiwire proportional chambers, signal processing, the use of semiconductors, and photo/optical applications. Circuits are considered along with instrumentation for space, nuclear medicine instrumentation, data acquisition and systems, environmental instrumentation, reactor instrumentation, and nuclear power systems. Attention is given to a new approach to high accuracy gaseous detectors, the current status of electron mobility and free-ion yield in high mobility liquids, a digital drift chamber digitizer system, the stability of oxides in high purity germanium, the quadrant photomultiplier, and the theory of imaging with a very limited number of projections.

Source record↗

A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine.

Hoover, R. B.↗

A target design for irradiation of NaI at high beam current.

A solution to the targetry problems encountered when the iodine nucleus is a target for cyclotron irradiation is given as a new target design. A target based on this design has been used in 30 microampere irradiations of 46 MeV alpha particles for one-half hour without significant damage. Such an irradiation produces 6 to 7 mCi of Cs-129, an isotope useful in nuclear medicine. This target should also be considered for cyclotron production of the radioisotopes Cs-127, I-123, and Xe-127.

Blue, J. W.↗

Evaluation of nuclear-reactor-produced iodine-123

Iodine-123 has such great potential for nuclear medicine that all possible production methods should be considered. In this report, an experimental study related to I-123 production at a high-intensity fast-flux reactor using the reaction Xe-124(n,2n)Xe-123 is considered. The conclusion is that I-123 could be made in small quantities and the cost would be higher than the cyclotron methods presently used.

Blue, J. W.↗

Sealed high-pressure x-ray detector

Detector is filled to pressure of 2 atm with mixture of 95% xenon and 5% methane for recording hard x-ray (50-to100-keV0 images with spatial resolution of about 1 mm. Being sealed, detector requires no gas purification or replenishment after initial fill. Potential areas of application include nuclear medicine, and x-ray or gamma-ray astronomy.

Gorenstein, P.↗

Radiological health risks to astronauts from space activities and medical procedures

Radiation protection standards for space activities differ substantially from those applied to terrestrial working situations. The levels of radiation and subsequent hazards to which space workers are exposed are quite unlike anything found on Earth. The new more highly refined system of risk management involves assessing the risk to each space worker from all sources of radiation (occupational and non-occupational) at the organ level. The risk coefficients were applied to previous space and medical exposures (diagnostic x ray and nuclear medicine procedures) in order to estimate the radiation-induced lifetime cancer incidence and mortality risk. At present, the risk from medical procedures when compared to space activities is 14 times higher for cancer incidence and 13 times higher for cancer mortality; however, this will change as the per capita dose during Space Station Freedom and interplanetary missions increases and more is known about the risks from exposure to high-LET radiation.

Peterson, Leif E.↗

The Canadian experience: Using telemedicine for the support of medical care at remote sites

While the majority of Canadians live in a narrow strip about 200 miles wide just north of the 45th parallel, a significant proportion of the population lives in non-urban, remote and sometimes isolated areas. Given this widely dispersed population, the provision of health services has always been a challenge. A list of non-urban health needs include the following: consulting services; clinical laboratory resources; investigative techniques (e.g., EEG, radiology, ultrasound, nuclear medicine); continuing education for physicians, nurses and other health professionals; teaching and training programs for administrative and support staff (dietary, housekeeping, maintenance); community health education and improved general education for health workers and families. For nearly three decades physicians and other health care professionals in the United States and Canada have been exploring the application of telecommunications to health care in rural and remote areas. The terms telemedicine and telehealth are used interchangeably to describe this activity. The prefix 'tele' refers to distance and now includes all types of communication over distance that support health care and health educational programs. Actually, telemedicine is as old as the telephone, which is still the most widely used communications technology in health care.

House, Maxwell↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occuring during the readout window.

Lacy, Jeffrey L.↗