Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NRAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Overview of the Neutron Radiography Reactor (NRAD) for Neutron Imaging and In-Core Experiment Capabilities at Idaho National Laboratory

NRAD is a 250-kilowatt TRIGA research reactor that first went online at INL in 1977. (TRIGA stands for Training, Research, Isotopes, General Atomics.) Historically, NRAD was utilized as a neutron radiography reactor that provides comprehensive, non-destructive information about the internal condition of irradiated nuclear fuel. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography at NRAD. In recent years, NRAD has gone through a transformation from the single purpose radiography reactor for which it was designed into a multipurpose research reactor, and expanding its in-core irradiation capabilities to support a broader mission for the US Department of Energy (DOE) Nuclear Energy (NE) programs, Basic Energy Science (BES) Programs, as well as Fusion Energy programs. NRAD is a designated user facility under the DOE Nuclear Science User Facility (NSUF) program, and is available for access for general public via a competitive proposal process. More information about NSUF and NRAD are available from the website: https://nsuf.inl.gov/Home/Facility/654.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Assembly and Functional Test of NRAD Heated Instrumentation Rig

This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NRAD Program Presentation

This is a PowerPoint presentation highlighting the Idaho National Laboratory's Neutron Radiography Reactor, NRAD, programmatic capabilities, neutron radiography quality assurance requirements, and examples of resulting training, informational, and typical radiographic capabilities for nondestructive testing of irradiated nuclear reactor fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heated Test of Neutron Sensor in NRAD

This document is a short PowerPoint slide deck which illustrates completion of an FY21 milestone associated with the Advanced Sensor Initiative (ASI). These slides will be attached to a Department of Energy PICS entry claiming completion of the milestone. The milestone was to conduct high temperature irradiation testing of neutron flux sensors (M3CT-21IN0702024). The test was conducted 8/25/2021 and reached a temperature of 800C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complete high temperature test of neutron flux sensors in NRAD

The purpose of this test was to characterize operation of Self Powered Neutron Detectors (SPNDs) at high temperature and shake out any bugs in the data acquisition equipment prior to testing at higher flux in MITR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specifications of EBR-II Neutron Radiography Method Description and Digitization Approach

All neutron radiography (NRAD) images of fuel pins in Argonne’s collection were originally generated using the NRAD imaging facility established in the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). The NRAD reactor facility was built in 1977 and has been operating since. The reactor is a TRIGA-type reactor operating at a power level of 250 kWth to provide a neutron source for radiography imaging. The reactor is equipped with two beam tubes (i.e., east beam tube and north beam tube) to guide the neutron beams to two radiography stations. The east radiography station is directly under the HFEF main cell and is dedicated for specimens already in the HFEF hot cell. The north radiography station is outside of the main HFEF hot cell and allows NRAD imaging of non-irradiated items. The NRAD images of EBR-II irradiated metallic fuel pins were taken in the east radiography station. Thermal neutrons have the capability to transmit through most materials and are ideal for NRAD imaging. However, because of their high thermal neutron absorption cross-section, fissile materials (e.g., highly-enriched nuclear fuels) may not be as transmissible to thermal neutrons. This is also the case for oversize specimens with extraneous thickness. Epithermal neutron imaging is therefore used as a complement to thermal neutron NRAD imaging. At HFEF’s NRAD facility, both thermal and epithermal neutrons can be used for NRAD imaging. Irradiated nuclear fuels emit high levels of γ radiation that can easily darken X-ray films, so direct exposure NRAD cannot be used to image them. Instead, an indirect NRAD imaging method was developed at HFEF’s NRAD facility. In this method, foils made of materials that can be activated by neutrons (i.e., with large neutron absorption cross section) are used to collect transmitted neutron signals. Then the activated foils are then placed against X-ray films and enclosed in a vacuum cassette so that the γ decay from the activated foils can produce images on the X-ray films. Then, general X-ray film processing procedures are used to digitize and store the images. By using different foil materials, different energy neutrons can be used for NRAD imaging. At the HFEF NRAD station, two types of films are commonly used: dysprosium (Dy) foils with thickness of 130 microns are used to capture thermal neutron signal, while indium (In) foils with thickness of 130 microns are used to capture epithermal neutron signal. A cadmium or gadolinium foil is put before the indium foil to work as a thermal neutron filter. The thermal and epithermal NRAD images can be taken simultaneously by using a Dy/Cd/In sandwiched foil combination. The typical NRAD exposure time is approximately 20 minutes. Then the exposed foils are transferred to film vacuum cassettes. The vacuum ensures that there is no gap between the foil and the film. The foil-to-film exposure time is at least three half-lives of the corresponding radioisotopes, which are 3 hours for In and 7.5 hours for Dy, respectively. Exposed films are processed using an automatic film processor to produce completed NRAD images.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

Reirradiation and Post-reirradiation Heating Tests of Loose AGR-2 TRISO Particles and AGR-3/4 Fuel Compacts

To address the lack of data on the behavior of short-lived fission products I-131 (t1/2 = 8.02 d) and Xe-133 (t1/2 = 5.24 d) in the TRISO fuel system, loose AGR-2 particles and kernels were reirradiated in NRAD and subjected to post-reirradiation heating in the FACS furnace. This provided data on the release of fission products from exposed kernels, and the results were used to establish FACS condensation plate collection efficiencies for temperatures of 1000, 1200, and 1400°C where previously, the only collection efficiencies were for 1600°C tests. These new collection efficiencies were then applied to the NRAD-FACS tests of entire AGR-3/4 fuel compacts. Understanding the relative behavior of short-lived I-131, for example, is important because it is a significant contributor to offsite dose during postulated accidents, and Xe-133 has previously been used as a conservative indicator of I-131 behavior. These data will be used to support refinement of fission product transport models and HTGR source-term analyses.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-pitch nano-accuracy surface profiler for strongly curved X-ray mirror metrology

We present our recent research and development effort on the Multi-Pitch Nano-accuracy Surface Profiler (MPNSP). This metrology instrument is developed to characterize strongly curved X-ray mirrors proposed to achieve diffraction-limited soft X-ray focusing for scientific applications at the synchrotron beamlines. The measurement process consists of forward-and-backward scans on the test mirror surface along its tangential direction at multiple pitch angles. Our research and development in this work aim to take the challenge of measuring strongly curved X-ray mirrors with a typical total slope range ≳10 mrad, while maintaining the Root Mean Square (RMS) value of measurement repeatability and self-consistency at 50 nrad RMS level. We first introduce the mechanical design, followed by a brief review of the mathematical model and the optimization algorithm for the MPNSP technique. By detecting the rotation axis of the mirror pitch with a machine vision approach, we can determine and then reduce the vertical distance between the pitch rotation axis and the test mirror surface to a sub-mm level. In addition, we describe a practical data acquisition procedure for strongly curved X-ray mirrors with a total slope range larger than the slope measuring range of the autocollimator used in the instrument. As a result, the proposed MPNSP measurements with different mirror orientations achieve remarkable self-consistency and reproducibility of < 50 nrad RMS in slope and < 0.5 nm RMS in height.

42 ENGINEERING↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗

Design and Fabrication of a Temperature-Controlled Fueled Molten Salt Capsule Irradiation Experiment

Idaho National Laboratory (INL) is developing a Molten salt Research Temperature-controlled Irradiation (MRTI) experimental capsule for the Neutron Radiography (NRAD) reactor. The experiment is envisaged to be versatile and able to host a variety of salt-wall material combinations. The first test is designed to contain actinide-bearing chloride salt, which previously has not been subjected to a neutron field. The main objectives of the experiment are to produce irradiated salt samples for Post Irradiation Examination (PIE), to evaluate salt behavior under irradiation, and to test in-situ sensors/instrumentation. The final design for the experiment completed in 2022, and fabrication of the experiment is underway. The salt is double encapsulated providing insulation and redundancy in the case of leakage. A gas-gap between the inner capsule and the outer container enables tuning of thermal conduction to the NRAD coolant by altering its thickness and its gas-mixture. An inert gas mixture ratio in the gas-gap ensures the configurations reached a targeted average salt temperature of 600oC, while avoiding salt freezing or exceeding material limits. A resistive heater placed within a thermowell and controls the temperature of the experiment (both when the reactor is on or off). The selected configurations can contain over 10 cm3 of fuel-bearing chloride salt, which is sufficient for the purposes of the post-irradiation examination (PIE) and provides sufficient volume for two submerged thermocouple probes to monitor salt temperature. The capsule wall material is Inconel 625, and weld qualifications for the assembly have been developed. A glove-box laser weld technique was refined as part of this process to ensure a leak-tight assembly for the salt-bearing assembly and reduce the risks of impurities permeating into the salt. This work was supported through the INL Laboratory Directed Research & Development (LDRD) Program under DOE Idaho Operations Office Contract DE-AC07-05ID14517.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ENYGF 2023 - Design of Temperature-controlled Fuel-salt Irradiation Experiment

Idaho National Laboratory (INL) is developing a Molten salt Research Temperature-controlled Irradiation (MRTI) experimental capsule for the Neutron Radiography (NRAD) reactor. The experiment is envisaged to be versatile and able to host a variety of salt-wall material combinations. The first test is designed to contain actinide-bearing chloride salt, which previously has not been subjected to a neutron field. The main objectives of the experiment are to produce irradiated salt samples for Post Irradiation Examination (PIE), to evaluate salt behavior under irradiation, and to test in-situ sensors/instrumentation. The final design for the experiment completed in 2022, and fabrication of the experiment is underway. The salt is double encapsulated providing insulation and redundancy in the case of leakage. A gas-gap between the inner capsule and the outer container enables tuning of thermal conduction to the NRAD coolant by altering its thickness and its gas-mixture. An inert gas mixture ratio in the gas-gap ensures the configurations reached a targeted average salt temperature of 600oC, while avoiding salt freezing or exceeding material limits. A resistive heater placed within a thermowell and controls the temperature of the experiment (both when the reactor is on or off). The selected configurations can contain over 10 cm3 of fuel-bearing chloride salt, which is sufficient for the purposes of the post-irradiation examination (PIE) and provides sufficient volume for two submerged thermocouple probes to monitor salt temperature. The capsule wall material is Inconel 625, and weld qualifications for the assembly have been developed. A glove-box laser weld technique was refined as part of this process to ensure a leak-tight assembly for the salt-bearing assembly and reduce the risks of impurities permeating into the salt. This work was supported through the INL Laboratory Directed Research & Development (LDRD) Program under DOE Idaho Operations Office Contract DE-AC07-05ID14517.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

BISON Simulated and Experimental Fission Product Release Comparisons from Reradiated AGR-3/4 Compacts During High Temperature Heating Tests

The fuel performance modeling code BISON was used to predict the release of fission products iodine-131 (131I), xenon-133 (133Xe), and krypton-85 (85Kr) from four re-irradiated AGR-3/4 fuel compacts containing tristructural isotropic (TRISO) coated particles during high-temperature isothermal heating tests. The AGR-3/4 fuel compacts were irradiated in the Advanced Test Reactor (ATR) as part of the third and fourth series of planned experiments to support the Advanced Gas Reactor (AGR) Program. They were subsequently stored and re-irradiated in the Neutron Radiography (NRAD) reactor for approximately five days and then stored for another five to eight days before being subjected to isothermal heating tests in the Fuel Accident Condition Simulation (FACS furnace) for 200 to 300 hours at temperatures between 1000°C and 1600°C to evaluate fission product release at elevated temperatures. New nuclide-specific fission product source term models for the three nuclides of interest were developed using the reactor multiphysics code Griffin and implemented into BISON to support this work. The new source term models were incorporated into coupled compact- and particle-scale BISON simulations, which predict spatially- and temporally-resolved radionuclide generation, radioactive decay, transport, and release throughout the entire irradiation history, including the initial ATR irradiation, NRAD re-irradiations, FACS heating tests, and intermediate periods spent in storage. The experimentally measured fission product release from the heating tests were compared to modeling release predictions calculated by BISON to evaluate how well the code compares to experimental results. Overall, the experimental measured and BISON predicted comparative release results varied but generally agreed to within 5 particle equivalents. Comparative release results identified general observations to take into consideration to help refine future models and reduce uncertainties associated with both the measurement results and predictive results. This includes developing new uranium oxycarbide (UCO) specific kernel diffusivities for the three isotopes examined to more accurately reflect the material properties of the fuel form. Deriving new diffusivities will aid in producing a more informed BISON model

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗