Engineering PapersSearch

SEARCH · Engineering Papers

Results for “NOISE MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality

Two-terminator RF adapter for background/environment noise measurement

A two-terminator RF adapter for background noise measurement in a test environment comprises a system test port comprising a system test port termination and a system test port connector to connect to a system under test; and a data acquisition port, comprising a data acquisition port termination and a data acquisition port connector to connect to a data acquisition system.

Kolski, Jeffrey

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors

Improved Bayesian regularization of inverse problems in vibrations and acoustics using noise-only measurements

Here, this paper studies Tikhonov regularization (ridge regression) parameter selection for problems in vibrations and acoustics. The selection method is based on a popular Bayesian method, but it incorporates measurements of sensor noise. The regularization parameter is closely related to the ratio of system input energy to noise energy, so noise measurements inform the inference procedure and improve parameter identification. In cases where standard Bayesian regularization identifies zero as the optimal regularization parameter, noise measurements guarantee a unique nonzero optimum. Sufficient theoretical criteria are developed for this guarantee. The method is verified in even-determined and under-determined configurations in an acoustic source localization simulation and a vibration load identification experiment. It is shown to yield significant improvements over existing empirical Bayesian regularization. Improvements are larger in the even-determined case and smaller in the under-determined case, wherein the inverse solution is less sensitive to the regularization parameter.

42 ENGINEERING

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN

A practical approach to calculating magnetic Johnson noise for precision measurements

Magnetic Johnson noise is an important consideration for many applications involving precision magnetometry, and its significance will only increase in the future with improvements in measurement sensitivity. The fluctuation–dissipation theorem can be utilized to derive analytic expressions for magnetic Johnson noise in certain situations, but when used in conjunction with finite element analysis tools, the combined approach is particularly powerful as it provides a practical means to calculate the magnetic Johnson noise arising from conductors of arbitrary geometry and permeability. In this paper, we demonstrate this method to be one of the most comprehensive approaches presently available to calculate thermal magnetic noise. In particular, its applicability is shown to not be limited to cases where the noise is evaluated at a point in space but also can be expanded to include cases where the magnetic field detector has a more general shape, such as a finite-size loop, a gradiometer, or a detector that consists of a polarized atomic species trapped in a volume. Furthermore, some physics insights gained through studies made using this method are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Experimental Investigation of Subcritical Neutron and Gamma Noise Methods at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE

Shot noise and universal Fano factor as a characterization of strongly correlated metals

Shot noise measures out-of-equilibrium current fluctuations and is a powerful tool to probe the nature of current-carrying excitations in quantum systems. Recent shot-noise measurements in the heavy-fermion strange metal YbRh 2 Si 2 exhibit a strong suppression of the Fano factor ( F )—the ratio of the current noise to the average current in the dc limit. This system is representative of metals in which electron correlations are extremely strong. Here we carry out the first theoretical study on the shot noise of diffusive metals in the regime of strong correlations. A Boltzmann-Langevin equation formulation is constructed in a quasiparticle description in the presence of strong correlations. We find that F = 3 / 4 in such a correlation regime. Thus, we establish the aforementioned Fano factor as universal to Fermi liquids, and we show that the Fano factor suppression observed in experiments on YbRh 2 Si 2 necessitates a loss of the quasiparticles. Our work opens the door to systematic theoretical studies of shot noise as a means of characterizing strongly correlated metallic phases and materials. Published by the American Physical Society 2024

Wang, Yiming (ORCID:0000000277582921)

Low spontaneous Brillouin scattering in anti-resonant hollow-core fibers in GHz frequency range

Brillouin light scattering (BLS) is a powerful experimental tool that can be used to gain insights into the fundamental and applied properties of matter, like dispersions of quasiparticles in a solid, as well as their spatiotemporal dynamics. Many applications of light scattering favor the use of optical fibers in place of free-space optics. In this study, we compare the performance of anti-resonant hollow core fibers to that of conventional solid core fused silica fibers for BLS experiments in the GHz frequency range. Conventional fibers are barely suitable for low-noise measurements because of the spontaneous scattering of photons on various phononic modes present in the core and cladding. In the case of the hollow-core fiber, we identify a range of discrete phononic modes and associate them with the various acoustic modes of the structure surrounding the hollow core using finite-element numerical simulations. The measured relative intensity of the spontaneous BLS signal from these modes is orders of magnitude smaller than that of a solid-core fiber, making anti-resonant hollow-core fibers one of the best solutions for the single-mode light guidance for BLS and potentially other low-noise photonic experiments.

36 MATERIALS SCIENCE

Redox Potential of Intermittently Wet Soil, Old Woman Creek National Estuarine Research Reserve, Huron, OH, 2023-05-10 to 2023-12-15

This dataset contains collected reduction-oxidation (redox) potential measurements of the underlying soil at various depths within a wetland, referred to as The Cove, at Old Woman Creek Estuarine Research Reserve in Huron, OH. Redox potential was measured in the sediments of a coastal wetland to assess how redox potential varies over time with changes in hydrological events. Measurements were collected by Campbell Scientific CR1000X dataloggers paired with a PaleoTerra redox probe and reference electrodes. Measurements were collected at 3 different locations within The Cove at multiple depths into the underlying soil of the wetland and were collected every 10 minutes. The Redox_Datafile.csv contains the recorded measurements of the redox probes, and the RefElecDataFile.csv contains the background-noise measurements collected by the reference electrodes. Redox_InstallMethods describes the installation methods of the datalogger and associated probes.

54 ENVIRONMENTAL SCIENCES

Transitions, Dynamics, and Driven States in Quantum Magnets (Final Report Revised)

Transitions into unusual electronic, optical, and magnetic states at the absolute zero of temperature display special properties that teach us about fundamental quantum mechanics and also underlie important technologies. These so-called quantum phase transitions intertwine the static and dynamical responses of the materials changing state. They are extremely sensitive to the effects of disorder and etch in high relief the role of quantum fluctuations. There are ample questions remaining about the character of such transitions and the nature of the competing quantum states. There are also opportunities to drive quantum materials out of equilibrium, with the possibility of new types of correlated and coherent order, and new ways to access the dynamical evolution of ground and excited states. We have investigated how the order develops in time and space, and the nature of the final configurations. We are able to compare and contrast classical and quantum excitations in our experimental system of choice, and thereby can trace the relative speed by which the system settles into its lowest-energy ground state. This comparison of quantum and classical annealing protocols lies at the heart of strategies for harnessing the power of quantum computers dedicated to optimization problems. A combination of magnetic susceptibility measurements at finite frequency where the magnetic spins are queried by an external ac field, dc magnetometry measurements that characterize the macroscopic strength of magnetic order and its resistance to change, noise measurements that reveal the microscopic fluctuations of the spins as they prepare to change state, and microwave spectroscopy to look at the response of both the electronic and nuclear degrees of freedom, have been performed as functions of temperature, magnetic field, frequency, excitation amplitude, magnetic spin concentration, and disorder. This combination of probes addresses issues of stability over time, overlap between spin states, the ability of the spins to respond independently or coherently, and the promise of control on the nanometer length scale. The research reported here provides insights into fundamental quantum physics. It also addresses the question of how best to use complex systems, such as magnetic solids, to stably process quantum information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Error mitigated metasurface-based randomized measurement schemes

Estimating properties of quantum states via randomized measurements has become a significant part of quantum information science. In this paper, we design an innovative approach leveraging metasurfaces to perform randomized measurements on photonic qubits, together with error mitigation techniques that suppress realistic metasurface measurement noise. Through fidelity and purity estimation, we confirm the capability of metasurfaces to implement randomized measurements and the unbiased nature of our error-mitigated estimator. Our findings show the potential of metasurface-based randomized measurement schemes in achieving robust and resource-efficient estimation of quantum state properties. Published by the American Physical Society 2024

Ren, Hang (ORCID:0000000255448692)

Gamma Neutron Correlated Noise of the EUCLID Critical Experiment

In this work, we present results from gamma noise measurements of a fast plutonium critical system for the first time. These results are compared to the more traditional method of neutron noise. Additionally, we investigate cross correlations of neutron and gamma signals and discuss the advantages of doing so.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES