Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Neutron Tunneling: A New Mechanism to Power Explosive Phenomena in Neutron Stars, Magnetars, and Neutron Star Mergers

Neutron tunneling between neutron-rich nuclei in inhomogeneous dense matter encountered in neutron star crusts can release enormous energy on a short timescale to power explosive phenomena in neutron stars. In this work, we clarify aspects of this process that can occur in the outer regions of neutron stars when oscillations or cataclysmic events increase the ambient density. We use a time-dependent Hartree–Fock–Bogoliubov formalism to determine the rate of neutron diffusion and find that large amounts of energy can be released rapidly. The roles of nuclear binding, two-body interaction, and pairing in neutron diffusion times are investigated. We consider a one-dimensional quantum diffusion model and extend our analysis to study the impact of diffusion in three dimensions. Here, we find that these novel neutron transfer reactions can generate energy in the amount of ≃ 10 40 –10 44 erg under suitable conditions and assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron-neutron quasifree scattering in neutron-deuteron breakup at 10 MeV

New measurements of the neutron-neutron quasifree scattering cross section in neutron-deuteron breakup at an incident neutron energy of 10.0 MeV are reported. The experiment setup was optimized to evaluate the technique for determining the integrated beam-target luminosity in neutron-neutron coincidence cross-section measurements in neutron-deuteron breakup. The measurements were carried out with a systematic uncertainty of ± 5.6%. Our data are in agreement with theoretical calculations performed using the CD-Bonn nucleon-nucleon potential in the Faddeev formalism. The measured integrated cross section over the quasifree peak is 20.5 ± 0.5(stat) ± 1.1 (sys) mb/sr 2 in comparison with the theory prediction of 20.1 mb/sr 2 . Overall, these results validate our technique for determining the beam-target luminosity in neutron-deuteron breakup measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Search for Neutron to Mirror Neutron Oscillations as an Explanation of the Neutron Lifetime Anomaly

We report an unexplained >4σ discrepancy persists between “beam” and “bottle” measurements of the neutron lifetime. A new model proposed that conversions of neutrons n into mirror neutrons n', part of a dark mirror sector, can increase the apparent neutron lifetime by 1% via a small mass splitting Δm between n and n' inside the 4.6 T magnetic field of the National Institute of Standards and Technology Beam Lifetime experiment. A search for neutron conversions in a 6.6 T magnetic field was performed at the Spallation Neutron Source which excludes this explanation for the neutron lifetime discrepancy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Search for Neutron to Mirror Neutron Oscillation Using Neutron Electric Dipole Moment Measurements

Baryon number violation is a key ingredient of baryogenesis. It has been hypothesized that there could also be a parity-conjugated copy of the standard model particles, called mirror particles. The existence of such a mirror universe has specific testable implications, especially in the domain of neutral particle oscillation, viz. the baryon number violating neutron to mirror-neutron (n−n′) oscillation. Consequently, there were many experiments that have searched for n−n′ oscillation, and imposed constraints upon the parameters that describe it. Recently, further analysis on some of these results have identified anomalies which could point to the detection of n−n′ oscillation. All the previous efforts searched for n−n′ oscillation by comparing the relative number of ultracold neutrons that survive after a period of storage for one or both of the two cases: (i) comparison of zero applied magnetic field to a non-zero applied magnetic field, and (ii) comparison where the orientation of the applied magnetic field was reversed. However, n−n′ oscillations also lead to variations in the precession frequency of polarized neutrons upon flipping the direction of the applied magnetic field. Precession frequencies are measured, very precisely, by experiments searching for the electric dipole moment. For the first time, we used the data from the latest search for the neutron electric dipole moment to constrain n−n′ oscillation. After compensating for the systematic effects that affect the ratio of precession frequencies of ultracold neutrons and cohabiting 199Hg-atoms, chief among which was due to their motion in non-uniform magnetic field, we constrained any further perturbations due to n−n′ oscillation. We thereby provide a lower limit on the n−n′ oscillation time constant of τnn′/|cos(β)|>5.7s,0.36T′

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IRDFF-II: A New Neutron Metrology Library

High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60 MeV neutron energy. The library is intended to support: a) applications in research reactors; b) safety and regulatory applications in the nuclear power generation in commercial fission reactors; and c) material damage studies in support of the research and development of advanced fusion concepts. The paper describes the contents of the library, documents the thorough verification process used in its preparation, and provides an extensive set of validation data gathered from a wide range of neutron benchmark fields. The new IRDFF-II library includes 119 metrology reactions, four cover material reactions to support self-shielding corrections, five metrology metrics used by the dosimetry community, and cumulative fission products yields for seven fission products in three different neutron energy regions. In support of characterizing the measurement of the residual nuclei from the dosimetry reactions and the fission product decay modes, the present document lists the recommended decay data, particle emission energies and probabilities for 68 activation products. It also includes neutron spectral characterization data for 29 neutron benchmark fields for the validation of the library contents. Additional six reference fields were assessed (four from plutonium critical assemblies, two measured fields for thermal-neutron induced fission on 233U and 239Pu targets) but not used for validation due to systematic discrepancies in C/E reaction rate values or lack of reaction-rate experimental data. Another ten analytical functions are included that can be useful for calculating average cross sections, average energy, thermal spectrum average cross sections and resonance integrals. The IRDFF-II library and comprehensive documentation is available online at www-nds.iaea.org/IRDFF/. Evaluated cross sections can be compared with experimental data and other evaluations at www-nds.iaea.org/exfor/endf.htm. The new library is expected to become the international reference in neutron metrology for multiple applications.

IAEA IRDFF↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a neutron multiplicity measurement with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26 ton Gadolinium (Gd)-loaded water Cherenkov detector located on the Booster Neutrino Beam line at Fermilab. Its main goals are the measurement of the neutron multiplicity in neutrino-nucleus interactions as well as the cross-section of Charged Current Quasi-Elastic (CCQE) neutrino interactions on water. Besides the physics goals, the experiment also aims to be a testbed for new technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillators (WbLS). This thesis presents a preliminary measurement of the neutron multiplicity with {ANNIE}, using an analysis conducted on a fraction of the 2021 beam year. As preparatory measures, the efficiency of ANNIE's Front Muon Veto (FMV) was determined to be {$\bar{\varepsilon}_{\mathrm{FMV}} = (95.6 \pm 1.6)\%$} while the average efficiency for active scintillator paddles in the Muon Range Detector (MRD) was found to be {$\bar{\varepsilon}_ {\mathrm{MRD}} = (92.1 \pm 7.9)\%$}. Furthermore, the simulation framework used for ANNIE was validated and adapted to reproduce the experimental data by comparing the detector response for samples of Michel electrons, Americium Beryllium neutrons, and through-going muons. The analysis finds average neutron yields of {$\bar{n}_{\mathrm{data}} (\mathrm{beam}) = (0.272 \pm 0.010_{\mathrm{stat}})$} for an inclusive set of all identified muon neutrino candidates and {$\bar{n}_{\mathrm{data}} (\mathrm{beam,FV}) = (0.287 \pm 0.044_{\mathrm{stat}})$ for interactions which happened inside of the Fiducial Volume of ANNIE, which was optimized to increase the neutron detection acceptance. The presented neutron multiplicity values represent the number of detected neutrons after all event selection cuts and are not yet corrected for the neutron detection efficiency. An equivalent analysis on a simulated beam sample predicts neutron yields of $\bar{n}_{\mathrm{MC}}(\mathrm{beam}) = (0.515 \pm 0.0 07_{\mathrm{stat}})$ and $\bar{n}_{\mathrm{MC}}(\mathrm{beam,FV}) = (0.627 \pm 0.031_{\mathrm{stat}})$, indicating that the models tend to overpredict the number of neutrons produced in such interactions. Systematic errors have been briefly considered to contribute {$\sigma_{\mathrm{sys,FMV}} \sim 0.01\,$neutrons/$\nu$-interaction} due to the slight FMV inefficiency and {$\sigma_{\mathrm{sys,n}} \sim 0.05\,$neutrons/$\nu$-interaction} due to the neutron detection efficiency. Simulation studies further highlighted the importance of neutron detection in Diffuse Supernova Background (DSNB) searches. A combination of neutron tagging and Convolutional Neural Networks was found to reduce the most relevant Neutral Current Quasi-Elastic (NCQE) interaction background below the signal level, achieving a Signal-to-Background ratio of 4:1. In a further study, we investigated the positive impact of a deployment of a WbLS target on the energy reconstruction in ANNIE. WbLS provides a scintillation signal from hadronic recoils in addition to the charged lepton that can be included in neutrino energy reconstruction. It was found that a deployed WbLS volume in ANNIE improves the neutrino energy reconstruction from 14\% to 12\%, with the potential of going beyond this if more sophisticated reconstruction algorithms are developed in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-Neutron Correlations in the Photofission of 238U

Background: In the fission of actinides, the nearly back-to-back motion of the fission fragments has a strong effect on the kinematics of fission neutrons. This leads to a favoring of opening angles near 0? and 180? in the neutron-neutron (n-n) opening angle distributions of correlated neutron pairs from the same fission event. Purpose: To measure the n-n opening angle and energy correlations in the photofission of 238U. As of this writing, measurements of correlated n-n opening angle distributions have been reported only for the spontaneous and neutron-induced fission of actinides. This work is the first to report such a measurement using photofission and will provide useful experimental input for photofission models used in codes such as MCNP and FREYA. Method: Fission is induced using bremsstrahlung photons produced via a low duty factor, pulsed, linear electron accelerator. The bremsstrahlung photon beam impinges upon a 238U target that is surrounded by a large neutron scintillation detection system capable of measuring particle position and time of flight, from which n-n opening angle and energy are measured. Neutron-neutron angular correlations are determined by taking the ratio between a correlated neutron distribution and an uncorrelated neutron distribution formed by the pairing of neutrons produced during different beam pulses. This analysis technique greatly diminishes effects due to detector efficiencies, acceptance, and experimental drifts. Results: The angular correlation of neutrons from the photofission of 238U shows a high dependence on neutron energy as well as a dependence on the angle of the emitted neutrons with respect to the incoming photon beam. Angular correlations were also measured using neutrons from the spontaneous fission of 252Cf, showing good agreement with past measurements. Conclusions: The measured angular correlations reflect the underlying back-to-back nature of the fission fragments. An anomalous decline in n-n yield was observed for opening angles near 180? for 238U.

Burggraf, Jeff↗

Correlations Between Fission Fragment and Neutron Anisotropies in Neutron-Induced Fission

Several sources of angular anisotropy for fission fragments and prompt neutrons have been studied in neutron-induced fission reactions. These include kinematic recoils of the target from the incident neutron beam and the fragments from the emission of the prompt neutrons, preferential directions of the emission of the fission fragments with respect to the beam axis due to the population of particular transition states at the fission barrier, and forward-peaked angular distributions of pre-equilibrium neutrons which are emitted before the formation of a compound nucleus. In addition, there are several potential sources of angular anisotropies that are more difficult to disentangle: the angular distributions of prompt neutrons from fully accelerated fragments or from scission neutrons, and the emission of neutrons from fission fragments that are not fully accelerated. Here, we study the effects of the first group of anisotropy sources, particularly exploring the correlations between the fission-fragment anisotropy and the resulting neutron anisotropy. While kinematic effects were already accounted for in our Hauser-Feshbach Monte Carlo code cgmf, anisotropic angular distributions for the fission fragments and pre-equilibrium neutrons resulting from neutron-induced fission on 233,234,235,238 U, 239,241 Pu, and 237 Np have been introduced for the first time. The effects of these sources of anisotropy are examined over a range of incident neutron energies, from thermal to 20 MeV, and compared with experimental data from the Chi-Nu liquid scintillator array. The anisotropy of the fission fragments is reflected in the anisotropy of the prompt neutrons, especially as the outgoing energy of the prompt neutrons increases, allowing for an extraction of the fission-fragment anisotropy to be made from a measurement of the neutrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 239 Pu$(n, f$) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy 1–20 MeV

Although the prompt fission neutron spectrum (PFNS) is an essential component of neutron-driven systems that has been measured for decades, there are still multiple glaring unknowns regarding the PFNS of major actinides in the fission neutron incident energy range, specifically with regard to multichance fission and pre-equilibrium neutron emission processes. The only impactful experimental 239 Pu PFNS measurements included in recent nuclear data evaluations were measured over a limited outgoing neutron energy range at thermal and 1.5-MeV average incident neutron energy, while other potentially impactful measurements have been shown to contain errors that resulted in either large uncertainty increases or in complete exclusion from nuclear data evaluation. Here, we report a measurement of the 239 Pu PFNS over a wide range of incident neutron energy (1–20 MeV) and three orders of magnitude in outgoing neutron energy (0.01–10 MeV) resulting from the Chi-Nu experiment at the Los Alamos Neutron Science Center. These results are the combination of separate PFNS measurements in the same experimental area, one using a Li-glass and the other a liquid scintillator detector array. Covariances between all PFNS data points from each detector and within each incident energy range were generated between all other data in both detector arrays and within all other incident neutron energy bins, yielding a single covariance matrix for all 1300 PFNS data points reported here. These covariances are based on a thorough assessment of systematic bias and uncertainties associated with the measurement, PFNS extraction technique, combination of data from each detector type, and other aspects of the analysis. The existence of covariances between PFNS data points in different incident neutron energy ranges yielded covariances between average PFNS energy values at each incident energy to be reported here as well, which allowed for firm statements to be made regarding a shape of a purely experimental mean PFNS energy trend for the first time. Although minor PFNS shape differences exist between the results reported here and recent nuclear data evaluations, the ENDF/B-VIII.0 and JEFF-3.3 PFNS evaluations agree reasonably well with the present results from 1-to 10-MeV incident neutron energy, which spans the well-measured 1.5-MeV incident neutron energy PFNS from Lestone and Shores as well as the onset of second-chance fission. However, while the pre-equilibrium component of the PFNS above 12-MeV incident neutron energy roughly agrees in position and magnitude with ENDF/B-VIII.0 and JEFF-3.3, clear differences relating to the relative magnitude of third-chance fission PFNS features are present in the PFNS shape and in the mean PFNS energy trends.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗