Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance of a New Composite Single-Crystal Filtered Thermal Neutron Beam for Neutron Capture Therapy Research at the University of Missouri

The University of Missouri (MU) Institute for Nano and Molecular Medicine, the Idaho National Laboratory (INL) and the University of Missouri Research Reactor (MURR) have undertaken a new collaborative research initiative to further the development of improved boron delivery agents for BNCT. The first step of this effort has involved the design and construction of a new thermal neutron beam irradiation facility for cell and small-animal radiobological research at the MURR. In this paper we present the beamline design with the results of pertinent neutronic design calculations. Results of neutronic performance measurements, initiated in February 2008, will also be available for inclusion in the final paper. The new beam will be located in an existing 152.4 mm (6’) diameter MURR beam tube extending from the core to the right in Figure 1. The neutron beam that emanates from the berylium reflector around the reactor is filtered with single-crystal silicon and single-crystal bismuth segments to remove high energy, fission spectrum neutrons and reactor gamma ray contamination. The irradiation chamber is downstream of the bismuth filter section, and approximately 3.95 m from the central axis of the reactor. There is sufficient neutron flux available from the MURR at its rated power of 10 MW to avoid the need for cryogenic cooling of the crystals. The MURR operates on average 150 hours per week, 52 weeks a year. In order to take advantage of 7800 hours of operation time per year the small animal BNCT facility will incorparate a shutter constucuted of boral, lead, steel and polyethylene that will allow experimenters to access the irradiation chamber a few minutes after irradiation. Independent deterministic and stochastic models of the coupled reactor core and beamline were developed using the DORT two-dimensional radiation transport code and the MCNP-5 Monte Carlo code, respectively. The BUGLE-80 47-neutron, 20-gamma group cross section library was employed for the DORT computations, in keeping with previous practice for analysis of a number of other NCT neutron facilities worldwide. The standard ENDF/B Version 6.8 cross section libraries were used with MCNP, except that special calculated cross section sets for the single-crystal bismuth and silicon filters in the MCNP calculations were provided to MU and INL specifically for this study by the Korean Atomic Energy Research Institute and, independently, by North Carolina State University. Cross sections for the amorphous bismuth and silicon files on the BUGLE-80 library used with DORT were modified to account for the single-crystal form of these materials using correction factors computed using MCNP. A number of parameter studies were conducted, independently varying the thicknesses of the silicon and bismuth filter sections to find an optimum that maximizes the thermal neutron flux while maintaining the fast-neutron and gamma components of the beam within acceptable ranges. Both the DORT and MCNP beamline optimization computations led to the conclusion that the silicon filtering section should be approximately 55 cm in thickness and the bismuth section should be 8 cm in thickness. The total estimated thermal neutron flux delivered to the irradiation location by the filtered beam, integrated to 0.414 eV, is approximately 9.0 x 108 neutrons/cm2-s. The calculations also yielded an epithermal and fast-neutron kerma of approximately 1.0 x 10-11 cGy-cm2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of an In-Beam Neutron Flux Monitor for Time of Flight Capture Measurements

Accurate nuclear data are important in several aspects of nuclear engineering, such as reactor simulations, nonproliferation, and criticality safety. One of the nuclear data measurements that requires reduced uncertainties in its related cross-sections is neutron capture. The neutron capture cross-sections have particular deficiencies in the incident neutron energy range from 1 keV to 1 MeV. This is due to the predominance of scattering reactions in this energy region. In order to provide more accurate measurements in this energy region, a new experimental setup has been designed and created at Rensselaer Polytechnic Institute (RPI). This experiment utilizes several C{sub 6}D{sub 6} detectors in a low mass system to minimize the effects of neutron scattering on the experiment. In order to determine the capture yield for the measurements, several additional factors need to be known about the neutron beam including the energy dependence of the neutron flux incident on the sample. A detector made from a thin piece of EJ-204 plastic scintillator was designed to measure the neutron flux, as a function of incident neutron energy, during the capture measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The pNab experiment and the quest for ever better neutron beam polarization

The Nab and pNAB collaborations are conducting a program of studies of free neutron beta decay, with the primary goal of testing the unitarity of the Cabbibo-Kobayashi-Maskawa matrix that describes quark mixing due to the weak interaction. For this purpose, a large, novel electromagnetic spectrometer, the Nab spectrometer, has been designed, built, and placed in use to determine the correlation coefficients in unpolarized neutron beta decay: "a", the neutrino-electron correlation coefficient; and "b", the Fierz term. The subject of this paper is pNAB, the second phase of the program, that will deploy the same spectrometer with a polarized neutron beam to determine "A", the beta asymmetry; and "B", the neutrino asymmetry coefficients. A focus of this paper will be on the strategies to provide a high and precisely known neutron beam polarization.

Baessler, Stefan↗

A High Count Rate Neutron Beam Monitor for Neutron Scattering Facilities

Abstract Beam monitors are an important diagnostic tool in neutron science facilities. Present beam monitors use either ionization chambers in integration mode, which are slow and have no timing information, or pulse counters which can easily be saturated by high beam intensities. At high flux neutron scattering facilities, neutron beam monitors with very low intrinsic efficiency (10-5) are presently selected to keep the counting rate within a feasible range, even when a higher efficiency would improve the counting statistics and yield a better measurement of the incident beam. In this work, we report on a high count rate neutron beam monitor. This beam monitor offers good timing with an intrinsic efficiency of 10-3 and a counting rate capability of over 1,000,000 cps without saturation.

high counting rate detectors↗

Analysis of the response of innovative neutron detectors with monoenergetic neutron beams

Various neutron detectors are currently under development at the University of Pisa. The response of these devices is investigated using monoenergetic neutron beams produced at the CN accelerator of INFN Legnaro National Laboratories with thin lithium target bombarded by protons at different energies, exploiting the {sup 7}Li(p,n){sup 7}Be reaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for a new cold neutron beam measurement of the neutron lifetime

In the most accurate cold neutron beam determination of the neutron lifetime based on the absolute counting of decay protons, the largest uncertainty was attributed to the absolute determination of the capture flux of the cold neutron beam. Currently an experimental effort is underway at the National Institute of Standards and Technology (NIST) that will significantly reduce this contribution to the uncertainty in the lifetime determination. The next largest source of uncertainty is the determination of the absolute count rate of decay protons, which contributes to the experimental uncertainty approximately at the 1 s level. Experience with the recent neutron radiative decay experiment, which used the neutron lifetime apparatus, has provided valuable insights into ways to reduce other uncertainties. In addition, the cold neutron fluence rate at NIST is presently 1.5 times greater than in the 2003 measurement, and there is the prospect for a significantly higher rate with the new guide hall expansion. This paper discusses an approach for achieving a determination of the neutron lifetime with an accuracy of approximately 1 s.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron beam imaging at neutron spectrometers at Dhruva

A low efficiency, 2-Dimensional Position Sensitive Neutron Detector based on delay line position encoding is developed. It is designed to handle beam flux of 10{sup 6}-10{sup 7} n/cm{sup 2}/s and for monitoring intensity profiles of neutron beams. The present detector can be mounted in transmission mode, as the hardware allows maximum neutron transmission in sensitive region. Position resolution of 1.2 mm in X and Y directions, is obtained. Online monitoring of beam images and intensity profile of various neutron scattering spectrometers at Dhruva are presented. It shows better dynamic range of intensity over commercial neutron camera and is also time effective over the traditionally used photographic method.

43 PARTICLE ACCELERATORS↗

Neutron-beam-shaping assembly for boron neutron-capture therapy

A neutron-beam-shaping assembly consisting of a moderator, a reflector, and an absorber is used to form a therapeutic neutron beam for the boron neutron-capture therapy of malignant tumors at accelerator neutron sources. A new structure of the moderator and reflector is proposed in the present article, and the results of a numerical simulation of the neutron spectrum and of the absorbed dose in a modified Snyder head phantom are presented. The application of a composite moderator and of a composite reflector and the implementation of neutron production at the proton energy of 2.3MeV are shown to permit obtaining a high-quality therapeutic neutron beam.

43 PARTICLE ACCELERATORS↗

Radiobiologic Significance of Response of Intratumor Quiescent Cells In Vivo to Accelerated Carbon Ion Beams Compared With {gamma}-Rays and Reactor Neutron Beams

Purpose: To clarify the radiosensitivity of intratumor quiescent cells in vivo to accelerated carbon ion beams and reactor neutron beams. Methods and Materials: Squamous cell carcinoma VII tumor-bearing mice were continuously given 5-bromo-2'-deoxyuridine to label all intratumor proliferating cells. Next, they received accelerated carbon ion or {gamma}-ray high-dose-rate (HDR) or reduced-dose-rate (RDR) irradiation. Other tumor-bearing mice received reactor thermal or epithermal neutrons with RDR irradiation. Immediately after HDR and RDR irradiation or 12 h after HDR irradiation, the response of quiescent cells was assessed in terms of the micronucleus frequency using immunofluorescence staining for 5-bromo-2'-deoxyuridine. The response of the total (proliferating plus quiescent) tumor cells was determined from the 5-bromo-2'-deoxyuridine nontreated tumors. Results: The difference in radiosensitivity between the total and quiescent cell populations after {gamma}-ray irradiation was markedly reduced with reactor neutron beams or accelerated carbon ion beams, especially with a greater linear energy transfer (LET) value. Clearer repair in quiescent cells than in total cells through delayed assay or a decrease in the dose rate with {gamma}-ray irradiation was efficiently inhibited with carbon ion beams, especially with a greater LET. With RDR irradiation, the radiosensitivity to accelerated carbon ion beams with a greater LET was almost similar to that to reactor thermal and epithermal neutron beams. Conclusion: In terms of tumor cell-killing effect as a whole, including quiescent cells, accelerated carbon ion beams, especially with greater LET values, are very useful for suppressing the dependency on the heterogeneity within solid tumors, as well as depositing the radiation dose precisely.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized 3 He neutron spin-filter

Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of ~10 9 neutrons per second per cm 2 and a cross sectional area of 10 x 12 cm 2 . The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized 3 He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the 3 He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured were done for the NPDGamma experiment, which measures the parity violating γ-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. Finally, the experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging of dynamic magnetic fields with spin-polarized neutron beams

Precession of neutron spin in a magnetic field can be used for mapping of a magnetic field distribution, as demonstrated previously for static magnetic fields at neutron beamline facilities. The fringing in the observed neutron images depends on both the magnetic field strength and the neutron energy. In this paper we demonstrate the feasibility of imaging periodic dynamic magnetic fields using a spin-polarized cold neutron beam. Our position-sensitive neutron counting detector, providing with high precision both the arrival time and position for each detected neutron, enables simultaneous imaging of multiple phases of a periodic dynamic process with microsecond timing resolution. The magnetic fields produced by 5- and 15-loop solenoid coils of 1 cm diameter, are imaged in our experiments with ~100 μm resolution for both dc and 3 kHz ac currents. Our measurements agree well with theoretical predictions of fringe patterns formed by neutron spin precession. We also discuss the wavelength dependence and magnetic field quantification options using a pulsed neutron beamline. Furthermore, the ability to remotely map dynamic magnetic fields combined with the unique capability of neutrons to penetrate various materials (e.g., metals), enables studies of fast periodically changing magnetic processes, such as formation of magnetic domains within metals due to the presence of ac magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of pixel-cell detector technology for Advanced Neutron Beam Monitors

Application of Pixel-Cell Detector Technology for Advanced Neutron Beam Monitors Specifications of currently available neutron beam detectors limit their usefulness at intense neutron beams of large-scale national user facilities used for the advanced study of materials. A large number of neutron-scattering experiments require beam monitors to operate in an intense neutron beam flux of >10E+7 neutrons per second per square centimeter. For instance, a 4 cm x 4 cm intense beam flux of 6.25 x 10E+7 n/s/cm2 at the Spallation Neutron Source will put a flux of 1.00 x 10E+9 n/s at the beam monitor. Currently available beam monitors with a typical efficiency of 1 x 10E-4 will need to be replaced in less than two years of operation due to wire and gas degradation issues. There is also a need at some instruments for beam position information that are beyond the capabilities of currently available He-3 and BF3 neutron beam monitors. ORDELA, Inc.’s research under USDOE SBIR Grant (DE-FG02-07ER84844) studied the feasibility of using pixel-cell technology for developing a new generation of stable, long-life neutron beam monitors. The research effort has led to the development and commercialization of advanced neutron beam detectors that will directly benefit the Spallation Neutron Source and other intense neutron sources such as the High Flux Isotope Reactor. A prototypical Pixel-Cell Neutron Beam Monitor was designed and constructed during this research effort. This prototype beam monitor was exposed to an intense neutron beam at the HFIR SNS HB-2 test beam site. Initial measurements on efficiency, uniformity across the detector, and position resolution yielded excellent results. The development and test results have provided the required data to initiate the fabrication and commercialization of this next generation of neutron-detector systems. ORDELA, Inc. has (1) identified low-cost design and fabrication strategies, (2) developed and built pixel-cell detectors and instrumented a 64-pixel-cell detector to specifications for the Cold-Neutron Chopper Spectrometer and POWGEN instruments, (3) investigated the general characteristics of this technology, (4) studied pixel-cell configurations and arrived at an optimized modular design, and (5) evaluated fabrication costs of mass production for these configurations. The resulting technology will enable a complete line of pixel-cell-based neutron detectors to be commercially under available. ORDELA, Inc has a good track history of application of innovative technology into the marketplace. Our commercialization record reflects this. For additional information, please contact Daniel Kopp at ORDELA, Inc. at +1 (865) 483-8675 or check our website at www.ordela.com.

36 MATERIALS SCIENCE↗

Neutron beam characterization measurements at the Manuel Lujan Jr. neutron scattering center

We have measured the neutron beam characteristics of neutron moderators at the Manuel Lujan Jr. Neutron Scattering Center at LANSCE. The absolute thermal neutron flux, energy spectra and time emission spectra were measured for the high resolution and high intensity decoupled water, partially coupled liquid hydrogen and partially coupled water moderators. The results of our experimental study will provide an insight into aging of different target-moderator-reflector-shield components as well as new experimental data for benchmarking of neutron transport codes.

43 PARTICLE ACCELERATORS↗

McStas Analysis of Monoenergetic Thermal Neutron Beam Generation for Total Cross Section Measurements

The thermal neutron scattering law (TSL) of a given material represents data that is essential for assessing the criticality safety of a neutronic system in which this material is utilized. Traditionally, the TSL is developed through elaborate calculations that combine input and models based on condensed matter physics and scattering theory. Nonetheless, measurements of key parameters (e.g., the total cross section at low energies) can help in benchmarking and validating TSL libraries such as those used in the ENDF/B database. In this work, the setup of experiments, at the PULSTAR reactor of North Carolina State University (NCSU), for creating monoenergetic thermal neutron beams in support of total scattering cross section measurements in the thermal energy range is explored using McStas simulations and experimental verification. A McStas model has been established of the NPD facility at the NCSU PULSTAR reactor to explore the production of monoenergetic thermal neutron beams in support of various applications including total cross section measurements. The McStas results clearly demonstrate the viability of six monochromatic thermal neutron beams with substantial intensities that allow future applications at the NPD facility. The experimental results reasonably support the computational model predictions. Based on these results, transmission thermal neutron experiments can be conducted for data validation studies. Furthermore, the model also allows the evaluation of design changes to expand the portfolio of available monoenergetic thermal neutron beams. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Generation of waves by a neutron beam in a two-component system formed by charged particles of nonzero spin

Dispersion relations for linear waves in amedium formed by electrons and ions and traversed by a beam of neutrons whose velocity has a nonzero constant component are derived by methods of quantum hydrodynamics. It is shown that, along with stable eigenmodes, vibrational excitations growing with time can be generated in the system owing to the interaction of spin components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗