Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRAL PARTICLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Specific features of measuring the isotopic composition of hydrogen ions in ITER plasma by using neutral particle diagnostics under neutral beam injection conditions

Results of numerical simulation of signals from neutral particle analyzers under injection of the heating and diagnostic neutral beams in different operating modes of the ITER tokamak are presented. The distribution functions of fast ions in plasma are simulated, and the corresponding neutral particle fluxes escaping from the plasma along the line of sight of the analyzers are calculated. It is shown that the injection of heating deuterium (D{sup 0}) beams results in the appearance of an intense background signal hampering measurements of the ratio between the densities of deuterium and tritium fuel ions in plasma in the thermal energy range. The injection of a diagnostic hydrogen (H{sup 0}) beam does not affect measurements owing to the high mass resolution of the analyzers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On geometric factors for neutral particle analyzers

Neutral particle analyzers (NPA) detect neutralized energetic particles that escape from plasmas. Geometric factors relate the counting rate of the detectors to the intensity of the particle source. Accurate geometric factors enable quick simulation of geometric effects without the need to resort to slower Monte Carlo methods. Previously derived expressions [G. R. Thomas and D. M. Willis, “Analytical derivation of the geometric factor of a particle detector having circular or rectangular geometry,” J. Phys. E: Sci. Instrum. 5(3), 260 (1972); J. D. Sullivan, “Geometric factor and directional response of single and multi-element particle telescopes,” Nucl. Instrum. Methods 95(1), 5–11 (1971)] for the geometric factor implicitly assume that the particle source is very far away from the detector (far-field); this excludes applications close to the detector (near-field). The far-field assumption does not hold in most fusion applications of NPA detectors. We derive, from probability theory, a generalized framework for deriving geometric factors that are valid for both near and far-field applications as well as for non-isotropic sources and nonlinear particle trajectories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Random Ray Method for neutral particle transport

A new approach to solving partial differential equations (PDEs) based on the method of characteristics (MOC) is presented. The Random Ray Method (TRRM) uses a stochastic rather than deterministic discretization of characteristic tracks to integrate the phase space of a problem. TRRM is potentially applicable in a number of transport simulation fields where long characteristic methods are used, such as neutron transport and gamma ray transport in reactor physics as well as radiative transfer in astrophysics. In this study, TRRM is developed and then tested on a series of exemplar reactor physics benchmark problems. The results show extreme improvements in memory efficiency compared to deterministic MOC methods, while also reducing algorithmic complexity, allowing for a sparser computational grid to be used while maintaining accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact and multi-view solid state neutral particle analyzer arrays on National Spherical Torus Experiment-Upgrade

A compact and multi-view solid state neutral particle analyzer (SSNPA) diagnostic based on silicon photodiode arrays has been successfully tested on the National Spherical Torus Experiment-Upgrade. The SSNPA diagnostic provides spatially, temporally, and pitch-angle resolved measurements of fast-ion distribution by detecting fast neutral flux resulting from the charge exchange (CX) reactions. The system consists of three 16-channel subsystems: t-SSNPA viewing the plasma mid-radius and neutral beam (NB) line #2 tangentially, r-SSNPA viewing the plasma core and NB line #1 radially, and p-SSNPA with no intersection with any NB lines. Due to the setup geometry, the active CX signals of t-SSNPA and r-SSNPA are mainly sensitive to passing and trapped particles, respectively. In addition, both t-SSNPA and r-SSNPA utilize three vertically stacked arrays with different filter thicknesses to obtain coarse energy information. The experimental data show that all channels are operational. The signal to noise ratio is typically larger than 10, and the main noise is x-ray induced signal. The active and passive CX signals are clearly observed on t-SSNPA and r-SSNPA during NB modulation. The SSNPA data also indicate significant losses of passing particles during sawteeth, while trapped particles are weakly affected. Fluctuations up to 120 kHz have been observed on SSNPA, and they are strongly correlated with magnetohydrodynamics instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for a heavy neutral particle decaying into an electron and a muon using 1 fb -1 of ATLAS data

A search is presented for a high mass neutral particle that decays directly to the e < sup > ± < /sup > μ < sup > ∓ < /sup > final state. The data sample was recorded by the ATLAS detector in √ s = 7 TeV pp collisions at the LHC from March to June 2011 and corresponds to an integrated luminosity of 1.07 fb < sup > -1 < /sup > . The data are found to be consistent with the Standard Model background. The high e < sup > ± < /sup > μ < sup > ∓ < /sup > mass region is used to set 95% confidence level upper limits on the production of two possible new physics processes: tau sneutrinos in an R-parity violating supersymmetric model and Z'-like vector bosons in a lepton flavor violating model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for long-lived neutral particles decaying into lepton jets in proton-proton collisions at $ \sqrt{s}=8 $ TeV with the ATLAS detector

Several models of physics beyond the Standard Model predict neutral particles that decay into final states consisting of collimated jets of light leptons and hadrons (so-called “lepton jets”). These particles can also be long-lived with decay length comparable to, or even larger than, the LHC detectors’ linear dimensions. This paper presents the results of a search for lepton jets in proton-proton collisions at the centre-of-mass energy of $ \sqrt{s}=8 $ TeV in a sample of 20.3 fb collected during 2012 with the ATLAS detector at the LHC. Limits on models predicting Higgs boson decays to neutral long-lived lepton jets are derived as a function of the particle’s proper decay length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Search for long-lived neutral particles in pp collisions at root s=13 TeV that decay into displaced hadronic jets in the ATLAS calorimeter

This paper describes a search for pairs of neutral, long-lived particles decaying in the ATLAS calorimeter. Long-lived particles occur in many extensions to the Standard Model and may elude searches for new promptly decaying particles. The analysis considers neutral, long-lived scalars with masses between 5 and 400 GeV, produced from decays of heavy bosons with masses between 125 and 1000 GeV, where the long-lived scalars decay into Standard Model fermions. The analysis uses either 10.8 fb -1 or 33.0 fb -1 of data (depending on the trigger) recorded in 2016 at the LHC with the ATLAS detector in proton–proton collisions at a centre-of-mass energy of 13 TeV. No significant excess is observed, and limits are reported on the production cross section times branching ratio as a function of the proper decay length of the long-lived particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studying fast-ion populations using oscillations in solid-state neutral-particle analyzer signal and neutral-beam injection power

A method for determining the fast-ion population density in magnetically confined plasmas as a function of pitch-radius, (λ, R), using a solid-state neutral-particle analyzer (ssNPA) signal and neutral-beam injection (NBI) power-output data has been developed. Oscillations in the NBI power output are replicated only in the active part of the ssNPA signal, allowing this to be separated from the passive and background signals, which usually complicate data from this diagnostic. Results obtained using this method are compared with those from standard techniques using data from the Mega-Amp Spherical Tokamak Upgrade spherical tokamak.

Instruments & Instrumentation↗

EFFECTS OF LEAKAGE NEUTRAL PARTICLES ON SHOCKS

In this paper, we investigate effects of neutral particles on shocks propagating into the partially ionized medium. We find that for 120 km s{sup -1} < u {sub sh} < 3000 km s{sup -1} (u {sub sh} is the shock velocity), about 10% of upstream neutral particles leak into the upstream region from the downstream region. Moreover, we investigate how the leakage neutral particles affect the upstream structure of the shock and particle accelerations. Using four-fluid approximations (upstream ions, upstream neutral particles, leakage neutral particles, and pickup ions), we provide analytical solutions of the precursor structure due to leakage neutral particles. It is shown that the upstream flow is decelerated in the precursor region and the shock compression ratio becomes smaller than without leakage neutral particles, but the total compression ratio does not change. Even if leakage of neutral particles is small (a few percent of total upstream particles), this smaller compression ratio of the shock can explain steep gamma-ray spectra from young supernova remnants. Furthermore, leakage neutral particles could amplify the magnetic field and heat the upstream region.

79 ASTRONOMY AND ASTROPHYSICS↗

A coarse-grained transport model for neutral particles in turbulent plasmas

The transport of neutral particles in turbulent plasmas is addressed from the prospect of developing coarse-grained transport models which can be implemented in code suites like B2-EIRENE, currently used for designing the ITER divertor. The statistical properties of turbulent fluctuations are described by a multivariate Gamma distribution able to retain space and time correlations through a proper choice of covariance function. We show that in the scattering free case, relevant for molecules and impurity atoms, the average neutral particle density obeys a Boltzmann equation with an ionization rate renormalized by fluctuations. This result lends itself to a straightforward implementation in the EIRENE Monte Carlo solver for neutral particles. Special emphasis is put on the inclusion of time correlations, and in particular on the ballistic motion of coherent turbulent structures. The role of these time dependent effects is discussed for D{sub 2} molecules and beryllium atoms. The sensitivity of our results to the assumptions on the statistical properties of fluctuations is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diamond neutral particle spectrometer for fusion reactor ITER

A compact diamond neutral particle spectrometer with digital signal processing has been developed for fast charge-exchange atoms and neutrons measurements at ITER fusion reactor conditions. This spectrometer will play supplementary role for Neutral Particle Analyzer providing 10 ms time and 30 keV energy resolutions for fast particle spectra in non-tritium ITER phase. These data will also be implemented for independent studies of fast ions distribution function evolution in various plasma scenarios with the formation of a single fraction of high-energy ions. In tritium ITER phase the DNPS will measure 14 MeV neutrons spectra. The spectrometer with digital signal processing can operate at peak counting rates reaching a value of 10{sup 6} cps. Diamond neutral particle spectrometer is applicable to future fusion reactors due to its high radiation hardness, fast response and high energy resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modelling the Alfvén eigenmode induced fast-ion flow measured by an imaging neutral particle analyzer

An imaging neutral particle analyzer (INPA) provides energy and radially resolved measurements of the confined fast-ion population ranging from the high-field side to the edge on the midplane of the DIII-D tokamak. In recent experiments, it was used to diagnose fast-ion flow in the INPA-interrogated phase-space driven by multiple, marginally unstable Alfvén eigenmodes (AEs). Here, the key features of this measured fast-ion flow are: (I) a fast-ion flow from q min and the injection energy (81 keV) towards lower energies and plasma periphery.(II) A flow from the same location towards higher energies and the plasma core, (III) a phase-space 'hole' at the injected energy and plasma core and (IV) a pile-up at the plasma core at lower energies (~60 keV). Ad hoc energetic particle diffusivity modelling of TRANSP significantly deviates from the observation. Comparably, a reduced modelling, i.e. a combination of NOVA-K and ASCOT5 code with the measured mode structure and amplitude, generally reproduce some key features of the observed phase-space flow, but largely failed to interpret fast ion depletion near the plasma axis. At last, self-consistent, first-principle multi-phase hybrid simulations that include realistic neutral beam injection and collisions are able to reproduce most features of the time-resolved phase-space flow. During consecutive hybrid phases, an RSAE consistent with the experiment grows and saturates, redistributing the injected fast ions. The resulting synthetic INPA images are in good agreement with the measurement near the injection energy. The simulations track the fast-ion redistribution within the INPA range, confirming that the measured fast-ion flow follows streamlines defined by the intersection of phase-space surfaces of constant magnetic moment μ and constant E' = nE + ωP φ , where n and ω are the instability toroidal mode number and frequency, and E and P φ the ion energy and toroidal canonical momentum. Nonperturbative effects are required to reproduce the depletion of fast ions near the magnetic axis at the injection energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a retarding potential grid system for a neutral particle analyzer

The ion energy distribution in a magnetically confined plasma can be inferred from charge exchange neutral particles. On the Madison Symmetric Torus (MST), deuterium neutrals are measured by the Florida A and M University compact neutral particle analyzer (CNPA) and the advanced neutral particle analyzer (ANPA). The CNPA energy range covers the bulk deuterium ions to the beginning of the fast ion tail (0.34–5.2 keV) with high-energy resolution (25 channels) while the ANPA covers the vast majority of the fast ion tail distribution (∼10–45 keV) with low energy resolution (10 channels). Though the ANPA has provided insight into fast ion energization in MST plasma, more can be gained by increasing the energy resolution in that energy range. To utilize the energy resolution of the CNPA, fast ions can be retarded by an electric potential well, enabling their detection by the diagnostic. The ion energy distribution can be measured with arbitrary resolution by combining data from many similar MST discharges with different energy ranges on the CNPA, providing further insight into ion energization and fast ion dynamics on MST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pinch

An advanced neutral particle analyzer (ANPA) capable of simultaneously measuring hydrogen and deuterium ions of energies up to 45 keV has recently been developed for use on the Madison Symmetric Torus. The charge-to-mass separation allows for separate analysis of bulk deuterium ions and hydrogen ions injected with a 1 MW, 25 keV neutral beam. Orientation of the ANPA allows sampling of different regions of ion velocity space; a radial viewport favors collection of ions with high v{sub Up-Tack }/ Double-Vertical-Line v Double-Vertical-Line while a recently installed tangential viewport favors ions with high v{sub Double-Vertical-Line Double-Vertical-Line }/ Double-Vertical-Line v Double-Vertical-Line , such as those from the core-localized fast ion population created by the neutral beam. Signals are observed in the ANPA's highest energy channels during periodic magnetic reconnection events, which are drivers of anisotropic, non-Maxwellian ion energization in the reversed-field pinch. ANPA signal strength is dependent on the background neutral density, which also increases during magnetic reconnection events, so careful analysis must be performed to identify the true change in the ion distribution. A Monte Carlo neutral particle tracing code (NENE) is used to reconstruct neutral density profiles based on D{sub {alpha}} line emission, which is measured using a 16-chord filtered photodiode array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact solid-state neutral particle analyzer in current mode

Solid state neutral particle analyzer (ssNPA) arrays are operated in current mode on the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). Compared with conventional pulse-counting NPAs, current-mode operation sacrifices energy resolution to obtain economical, high-bandwidth, pitch-angle resolved measurements. With the success from a new three-channel near-vertical-view current mode ssNPA on DIII-D, the apertures on an existing array on NSTX were expanded to increase the particle influx. The sightlines of both arrays intersect heating beams, enabling both active and passive charge exchange measurements. The spatial resolution at beam intersection is typically 5 cm on both devices. Directly deposited ultra-thin foils on the detector surface block stray photons below the energy of 1 keV and also set low energy threshold about 25 keV for deuterium particle detection. Oscillations in neutral flux produced by high frequency magnetohydrodynamics (MHD) instabilities are readily detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗