Computationally efficient evaluation of optimum homogeneous charge compression ignition operating range with accelerated multizone engine cycle simulation

The very intensive calculations necessary to define a performance map requiring evaluation of over a hundred individual operating points can be efficiently conducted with accelerated multizone for engine cycle simulation, leading to a definition of regions of acceptable and optimum homogeneous charge compression ignition operation. Accelerated multizone for engine cycle simulation has the virtue of enabling accurate evaluation of many operating conditions based on thermal stratification data from a single fluid mechanics run at motored conditions. This is possible because thermal stratification is more sensitive to engine geometry than to operating conditions. In this article, accuracy of accelerated multizone for engine cycle simulation is demonstrated by comparison with experimental data for iso-octane homogeneous charge compression ignition operation over a broad range of lean equivalence ratios (0.14–0.28). The validated accelerated multizone for engine cycle simulation model is then applied to generating a performance map for an engine controlled by appropriately adjusting equivalence ratio and internal exhaust gas recirculation. Regions of acceptable and optimum combustion are identified. It is finally demonstrated that while indicated mean effective pressure remains low for optimum homogeneous charge compression ignition operation (1–4 bar), this is sufficient for a large fraction of typical driving in light-duty vehicles. Much driving including idle can therefore be done in homogeneous charge compression ignition mode at high efficiency and low (essentially zero) NOx and particulate matter emissions.

30 DIRECT ENERGY CONVERSION↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Multizone Modeling of Black Hole Accretion and Feedback in 3D GRMHD: Bridging Vast Spatial and Temporal Scales

Simulating accretion and feedback from the horizon scale of supermassive black holes (SMBHs) out to galactic scales is challenging because of the vast range of scales involved. Elaborating on H. Cho et al., we describe and test a "multizone" technique, which is designed to tackle this difficult problem in three-dimensional general relativistic magnetohydrodynamic (GRMHD) simulations. While short-timescale variability should be interpreted with caution, the method is demonstrated to be well-suited for finding dynamical steady states over a wide dynamic range. We simulate accretion on a nonspinning SMBH ($a\ast$ = 0) using initial conditions and the external galactic potential from a large-scale galaxy simulation and achieve a steady state over eight decades in radius. As found in H. Cho et al., the density scales with radius as ρ ∝ r –1 inside the Bondi radius R B , which is located at R B = 2 × 10 5 r g (≈60 pc for M87), where r g is the gravitational radius of the SMBH; the plasma-β is ~ unity, indicating an extended magnetically arrested state; the mass accretion rate $\dot{M}$ is ≈1% of the analytical Bondi accretion rate ${\dot{M}}_{{\rm{B}}};$ and there is continuous energy feedback out to ≈100R B (or beyond > kpc) at a rate $\approx 0.02\dot{M}{c}^{2}$. Surprisingly, no ordered rotation in the external medium survives as the magnetized gas flows to smaller radii, and the final steady solution is very similar to when the exterior has no rotation. Using the multizone method, we simulate GRMHD accretion over a wide range of Bondi radii, R B ~ 10 2 –10 7 r g , and find that $\dot{M}/{\dot{M}}_{{B}}\approx {({R}_{{B}}/6\,{r}_{g})}^{-0.5}$.

79 ASTRONOMY AND ASTROPHYSICS↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building

The dispersion of indoor airborne contaminants across different zones within a mechanically ventilated building is a complex phenomenon driven by multiple factors. In this study, we modeled the indoor dispersion of airborne SARS-CoV-2 aerosols within a US Department of Energy detailed medium office prototype building using CONTAM software. The aim of this study is to improve our understanding about how different parts of a building can experience varying concentrations of the airborne viruses under different circumstances of release and mitigation strategies. Results indicate that unventilated stairwells can have significantly higher concentrations of airborne viruses. The mitigation strategies of morning and evening flushing of conditioned zones were not found to be very effective. Instead, a constant high percentage of outdoor air in the supply mix, and the use of masks, portable HEPA air cleaners, MERV 13 or higher HVAC air filters, and ultraviolet germicidal irradiation disinfection were effective strategies to prevent airborne viral contamination in the majority of the simulated office building.

60 APPLIED LIFE SCIENCES↗

Multizone Residential HVAC Modeling

This report will evaluate several building physics modeling tools to determine which are best suited for developing next-generation zoning technology. These modeling tools will be evaluated for their ability to predict room-level thermal loads, HVAC system operation, temperature and comfort predictions, and scalability. Any gaps in the existing tools will be identified and a path forward will be discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor Impact Evaluation at Different Sensor Locations in a Multi-zone Office Building

FY 2022 Q1 deliverables include the development of an emulator that can evaluate the sensor impacts at different sensor locations (i.e., thermostat locations) in a multizone office building. This report presents the detailed procedure of developing the emulator and using the emulator for preliminary sensor impact analysis. In designing new multizone buildings or retrofitting existing buildings, the room thermostat locations or subzoning design has been often determined by best practices without considering the effects of this design in terms of energy or thermal comfort. In subzoning design, the total number of thermostats is usually smaller than the total number of rooms. As a result, one thermostat in one room often controls the indoor temperature of several other adjacent rooms. For example, five zones might share one thermostat located in one of the zones. Because the demands for thermal load in different zones could be different for the multizone buildings, this subzoning design can compromise control performance and waste building energy consumption. Furthermore, for multizone buildings, subzoning could introduce thermal discomfort for zones. This issue has not be thoroughly investigated in simulation/field studies, and the US Department of Energy’s Oak Ridge National Laboratory explored the impacts of subzoning design through modeling and experimental study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of potential aerosol transmission and infectivity of SARS-CoV-2 through central ventilation systems

Here we evaluate the concentrations and probabilities of infection for both building interior and exterior exposure sources using a well-mixed model in a connected multizone building. As a central hub of many community and economic activities, buildings provide social connectivity, but the COVID-19 pandemic has reduced social connectivity due to concerns of viral spread within buildings. Although single zone models of infectious spread are well studied, the impact of aerosolized spread of SARS-CoV-2 via air handling systems in multizone buildings remains unexplored. Here we evaluate the influence of filtration, air exchange rates, and the fraction of outdoor air on the probability of infection using the well-known well-mixed modeling approach for a multizone. We find filtration lowers the concentration and probability of infection in both source and connected rooms provided at least some air is recirculated, but that probability is not zero. Filtration has no influence without recirculation or unless the outdoor air contains virus. We find that increasing the air exchange rate removes virus from the source room faster but also increases the rate of exposure to connected rooms. Therefore, slower air exchange rates reduce infectivity in connected rooms at shorter durations, but higher air exchange rates reduce infectivity at longer durations. We further find that when outdoor air is virus free, increasing the fraction of outdoor air is helpful, but, when outdoor air is infective, pathogen exposure inside can persist for hours after a short-term release.

60 APPLIED LIFE SCIENCES↗

Pressure Modification or Barrier Issues during Polymer Flooding Enhanced Oil Recovery

Effective oil displacement from a reservoir requires adequate and properly directed pressure gradients in areas of high oil saturation. If the polymer bank is too large or too viscous during a polymer flood, the pressure drops from the injection well to the polymer front may act as a pressure modification or barrier by usurping most of the downstream driving force for oil displacement. Polymer injection pressures must be limited. The maximum allowable injection pressure is commonly constrained by caprock integrity, injection equipment, and/or regulations, even though fractures can be beneficial to polymer injectivity. This paper examines when the pressure-barrier concept limits the size and viscosity of the polymer bank during a polymer flood. Analytical and numerical methods are used to address this issue. We examine the relevance of the pressure modification concept for a wide variety of circumstances, including oil viscosities ranging from 10 cp to 1650 cp, vertical wells versus horizontal wells, single versus multiple layered reservoirs, permeability contrast, and crossflow between layers. We also examine the relation between the pressure-barrier concept and fractures and fracture extension during polymer injection. We demonstrate that in reservoirs with single layers, the pressure-barrier concept only limits the optimum viscosity of the injected polymer if the mobility of the polymer bank is less than the mobility of the displaced oil bank. The same is true for multizoned reservoirs with no crossflow between layers. Thus, for these cases, the optimum polymer viscosity is likely to be dictated by the mobility of the oil bank, unless other factors intervene. For multizoned reservoirs with free crossflow between layers, the situation is different. A compromise must be reached between injected polymer viscosity and the efficiency of oil recovery. This work is particularly relevant to viscous oil reservoirs where polymer viscosities are substantially lower than the oil viscosity.

58 GEOSCIENCES↗

Bridging Scales in Black Hole Accretion and Feedback: Relativistic Jet Linking the Horizon to the Host Galaxy

Simulating black hole (BH) accretion and feedback from the BH horizon to galactic scales is extremely challenging, as it involves a vast range of scales. Recently, our multizone method has successfully achieved global dynamical steady states of hot accretion flows in 3D general relativistic magnetohydrodynamic simulations by tracking the bidirectional interaction between a nonspinning BH and its host galaxy. In this paper, we present technical improvements to the method and apply it to spin a * = 0.9 BHs, which power relativistic jets. We first test the new multizone setup with a smaller Bondi radius, R B ≈ 400 r g , where r g is the gravitational radius. The strongly magnetized accretion launches a relativistic jet with an intermediate feedback efficiency η ∼ 30%, in between that of a prograde (η ∼ 100%) and retrograde (η ∼ 10%) torus. Interestingly, both prograde and retrograde simulations also eventually converge to the same intermediate efficiency when evolved long enough, as accumulated magnetic fields remove gas rotation. We then extend strongly magnetized simulations to larger Bondi radii, R B ≈ 2 × 10 3 , 2 × 10 4 , 2 × 10 5 r g . We find that the BH accretion rate $\dot{M}$ is suppressed with respect to the Bondi rate as $\dot{M}_{\textrm{B}}$ as $\dot{M}/\dot{M}_{\textrm{B}} ∝ R_{\textrm{B}}^{-1/2}$. However, despite some variability, the time-averaged feedback efficiency remains at η ∼ 30%, independent of R B . This suggests that BH feedback efficiency in hot accretion flows is mainly governed by the BH spin (a * ) rather than by the galactic properties (R B ). From these first-principles simulations, we provide a feedback subgrid prescription for cosmological simulations: $\dot{E}_{\textrm{fb}} = 2$ x $10^{-3}[R_{\textrm{B}}/(2$ x $10^5 r_g)]^{-1/2}$ $\dot{M}_{\textrm{B}}c^2$ for BH spin a * = 0.9.

79 ASTRONOMY AND ASTROPHYSICS↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

A tidal disruption event coincident with a high-energy neutrino

Cosmic neutrinos provide a unique window into the otherwise hidden mechanism of particle acceleration in astrophysical objects. The IceCube Collaboration recently reported the likely association of one high-energy neutrino with a flare from the relativistic jet of an active galaxy pointed towards the Earth. However a combined analysis of many similar active galaxies revealed no excess from the broader population, leaving the vast majority of the cosmic neutrino flux unexplained. Here we present the likely association of a radio-emitting tidal disruption event, AT2019dsg, with a second high-energy neutrino. AT2019dsg was identified as part of our systematic search for optical counterparts to high-energy neutrinos with the Zwicky Transient Facility. The probability of finding any coincident radio-emitting tidal disruption event by chance is 0.5%, while the probability of finding one as bright in bolometric energy flux as AT2019dsg is 0.2%. Our electromagnetic observations can be explained through a multizone model, with radio analysis revealing a central engine, embedded in a UV photosphere, that powers an extended synchrotron-emitting outflow. This provides an ideal site for petaelectronvolt neutrino production. Assuming that the association is genuine, our observations suggest that tidal disruption events with mildly relativistic outflows contribute to the cosmic neutrino flux.

79 ASTRONOMY AND ASTROPHYSICS↗

Layer-dependent spin-resolved electronic structure of ferromagnetic triple-layered ruthenate Sr4Ru3O10

High-resolution angle- and spin-resolved photoemission spectroscopy (ARPES) of the triple-layered ruthenate Sr4Ru3O10 reveals features of the electronic structure that extend our understanding of the layered strontium ruthenates. The spectra near the Fermi energy are very different from the nonmagnetic analogues Sr2RuO4 and Sr3Ru2O7 with distinct Fermi surfaces for wide electronlike minority spin bands around the zone center and narrow holelike majority spin Fermi surface contours around the zone corners. The most dramatic results are two narrow spectral peaks ∼30 meV below the Fermi level, a spin-minority holelike band at the Brillouin zone center, and a spin-majority saddle-band van Hove singularity at the zone edge, which exhibits almost 100% spin polarization at low temperature, and a strong temperature dependent coherence-incoherence crossover attributed to Hund metal correlations. Quantitative comparison of the ARPES to spin-polarized density functional theory (DFT) calculations identify the specific antibonding and nonbonding orbital origins of the narrow bands, with a prediction of different spatial localization in the central and outer layers. This is shown to be consistent with experimental ARPES multizone matrix element intensity variations, and implicates outer-layer-specific control of the in-plane metamagnetism. The renormalization of the bands relative to the mean-field DFT, the demonstration of spin-polarized oxygen bands, and of spin-minority and spin-majority band-crossing hybridization provide a more complete picture of the magnetism which displays aspects of both delocalized and local moment behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗