Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multi-Unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Protein crystal growth in low gravity

This research involved (1) using the Atomic Force Microscope (AFM) in a study on the growth of lysozyme crystals and (2) refinement of the design of the Thermonucleator which controls the supersaturation required for the nucleation and growth of protein crystals separately. AFM studies of the (110) tetragonal face confirmed that lysozyme crystals grow by step propagation. There appears to be very little step pile up in the growth regimes which we studied. The step height was measured at = 54A which was equal to the (110) interpane spacing. The AFM images showed areas of step retardation and the formation of pits. These defects ranged in size from 0.1 to 0.4 mu. The source of these defects was not determined. The redesign of the Thermonucleator produced an instrument based on thermoelectric technology which is both easier to use and more amenable to use in a mu g environment. The use of thermoelectric technology resulted in a considerable size reduction which will allow for the design of a multi-unit growth apparatus. The performance of the new apparatus was demonstrated to be the same as the original design.

Feigelson, Robert S.↗

Geometrical approach to neural net control of movements and posture

In one approach to modeling brain function, sensorimotor integration is described as geometrical mapping among coordinates of non-orthogonal frames that are intrinsic to the system; in such a case sensors represent (covariant) afferents and motor effectors represent (contravariant) motor efferents. The neuronal networks that perform such a function are viewed as general tensor transformations among different expressions and metric tensors determining the geometry of neural functional spaces. Although the non-orthogonality of a coordinate system does not impose a specific geometry on the space, this "Tensor Network Theory of brain function" allows for the possibility that the geometry is non-Euclidean. It is suggested that investigation of the non-Euclidean nature of the geometry is the key to understanding brain function and to interpreting neuronal network function. This paper outlines three contemporary applications of such a theoretical modeling approach. The first is the analysis and interpretation of multi-electrode recordings. The internal geometries of neural networks controlling external behavior of the skeletomuscle system is experimentally determinable using such multi-unit recordings. The second application of this geometrical approach to brain theory is modeling the control of posture and movement. A preliminary simulation study has been conducted with the aim of understanding the control of balance in a standing human. The model appears to unify postural control strategies that have previously been considered to be independent of each other. Third, this paper emphasizes the importance of the geometrical approach for the design and fabrication of neurocomputers that could be used in functional neuromuscular stimulation (FNS) for replacing lost motor control.

Review↗

Shifting the Inertial Navigation Paradigm with MEMS Technology

Why don t you use MEMS? is one of the most common questions posed to navigation systems engineers designing inertial navigation solutions in the modern era. The question stems from a general understanding that great strides have been made in terrestrial MEMS accelerometers and attitude rate sensors in terms of accuracy, mass, and power. Yet, when compared on a unit-to-unit basis, MEMS devices do not provide comparable performance (accuracy) to navigation grade sensors. This paper will propose a paradigm shift where the comparison in performance is between multiple MEMS devices and a single navigation grade sensor. The concept is that systematically, a sufficient number of MEMS sensors may mathematically provide comparable performance to a single navigation grade device and be competitive in terms power and mass allocations when viewed on a systems level. The implication is that both inertial navigation system design and fault detection, identification, and recovery could benefit from a system of MEMS devices in the same way that swarm sensing has benefited Earth observation and astronomy. A survey of the state of the art in inertial sensor accuracy scaled by mass and power will be provided to show the specific error in MEMS and navigation graded devices, a mathematical comparison of multi-unit to single-unit sensor errors will be developed, and preliminary applications to Constellation vehicles will be explored.

Crain, Timothy↗

Shifting the Intertial Navigation Paradigm with the MEMS Technology

"Why don't you use MEMS?" is of the most common questions posed to navigation systems engineers designing inertial navigation solutions in the modern era. The question stems from a general understanding that great strides have been made in terrestrial MEMS accelerometers and attitude rate sensors in terms of accuracy, mass, and power. Yet, when compared on a unit-to-unit basis, MEMS devices do not provide comparable performance (accuracy) to navigation grade sensors in several key metrics. This paper will propose a paradigm shift where the comparison in performance is between multiple MEMS devices and a single navigation grade sensor. The concept is that systematically, a sufficient number of MEMS sensors may mathematically provide comparable performance to a single navigation grade device and be competitive in terms power and mass allocations when viewed on a systems level. The implication is that both inertial navigation system design and fault detection, identification, and recovery could benefit from a system of MEMS devices in the same way that swarm sensing has benefited Earth observation and astronomy. A survey of the state of the art in inertial sensor accuracy scaled by mass and power will be provided to show the scaled error in MEMS and navigation graded devices, a mathematical comparison of multi-unit to single-unit sensor errors will be developed, and preliminary application to an Orion lunar skip atmospheric entry trajectory will be explored.

Crain, Timothy P., II↗

Development and Testing of Molecular Adsorber Coatings

The effect of on-orbit molecular contamination has the potential to degrade the performance of spaceflight hardware and diminish the lifetime of the spacecraft. For example, sensitive surfaces, such as optical surfaces, electronics, detectors, and thermal control surfaces, are vulnerable to the damaging effects of contamination from outgassed materials. The current solution to protect these surfaces is through the use of zeolite coated ceramic adsorber pucks. However, these pucks and its additional complex mounting hardware requirements result in several disadvantages, such as size, weight, and cost related concerns, that impact the spacecraft design and the integration and test schedule. As a result, a new innovative molecular adsorber coating was developed as a sprayable alternative to mitigate the risk of on-orbit molecular contamination. In this study, the formulation for molecular adsorber coatings was optimized using various binders, pigment treatment methods, binder to pigment ratios, thicknesses, and spray application techniques. The formulations that passed coating adhesion and vacuum thermal cycling tests were further tested for its adsorptive capacity. Accelerated molecular capacitance tests were performed in an innovatively designed multi-unit system containing idealized contaminant sources. This novel system significantly increased the productivity of the testing phase for the various formulations that were developed. Work performed during the development and testing phases has demonstrated successful application of molecular adsorber coatings onto metallic substrates, as well as, very promising results for the adhesion performance and the molecular capacitance of the coating. Continued testing will assist in the qualification of molecular adsorber coatings for use on future contamination sensitive spaceflight missions.

Abraham, Nithin↗

A Study of Photoionized Gas in Two H װ Regions of the N44 Complex in the LMC Using MUSE Observations

We use the optical integral field observations with Multi-Unit Spectroscopic Explorer (MUSE) on the Very Large Telescope, together with CLOUDY photoionization models, to study ionization structure and physical conditions of two luminous H װ regions in the N44 star-forming complex of the Large Magellanic Cloud. The spectral maps of various emission lines reveal a stratified ionization geometry in N44 D1. The spatial distribution of [O ו] λ6300 emission in N44 D1 indicates a partially covered ionization front at the outer boundary of the H װ region. These observations reveal that N44 D1 is a blister H װ region. The [O ו] λ6300 emission in N44 C does not provide a well-defined ionization front at the boundary, while patches of [S װ] λ6717 and [O ו] λ6300 emission bars are found in the interior. The results of spatially resolved MUSE spectra are tested with the photoionization models for the first time in these H װ regions. A spherically symmetric ionization-bounded model with a partial covering factor, which is appropriate for a blister H װ region, can well reproduce the observed geometry and most of the diagnostic line ratios in N44 D1. Similarly, in N44 C we apply a low-density and optically thin model based on the observational signatures. Our modeling results show that the ionization structure and physical conditions of N44 D1 are mainly determined by the radiation from an O5 V star. However, local X-rays, possibly from supernovae or stellar wind, play a key role. In N44 C, the main contribution is from three ionizing stars.

H II regions↗

Production of Flight Instruments for Multi-Satellite Constellations

Recent National Academy of Science Decadal Surveys in space and Earth-science have called for simultaneous, distributed multi-point measurements in and from space, requiring constellations of small spacecraft. Small satellites have demonstrated their utility for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to enable meaningful measurement-based scientific investigations that operate on small satellites and that are responsive to science objectives described in National Academy of Science Decadal Surveys. The advent of high capability small spacecraft enables consideration of science missions involving multiple small spacecraft, constellations of a few or many for simultaneous distributed in situ observations or remote observations from a variety of viewpoints. The central challenge for fielding instrumented space-flight constellations is to provide the required multiple sets of fully verified and calibrated instrument hardware, software, and operational processes from within a one-off project-based scientific space flight culture. Although there are numerous commercial entities providing “off-the shelf” spacecraft and avionics, the challenge lies in the multi-unit production of the uniquely targeted instrumentation necessary to perform the specific measurements required for a particular science investigation. Traditionally, the cost of such instrumentation has represented a significant portion of the hardware cost for a mission and posed the highest risk area for implementation. A shift in paradigm from large science platforms to constellations of smaller satellites drives the challenge to build instruments in a quasi-production environment. This paper describes key aspects of, and challenges encountered in the development program for the successful production of instruments for the Fast-Plasma Investigation (FPI) instrument suite of 64 flight plasma spectrometers and supporting electronics on the NASA Magnetospheric Multiscale (MMS) 4 satellite constellation mission. Although the MMS mission was not composed of small satellites, there are key aspects of the instrument production that apply directly to constellations of small satellites.

Arthur D Jacques↗

Production of Flight Instruments for Multi-Satellite Constellations

Recent National Academy of Science Decadal Surveys in space and Earth-science have called for simultaneous, distributed multi-point measurements in and from space, requiring constellations of small spacecraft. Small satellites have demonstrated their utility for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to enable meaningful measurement-based scientific investigations that operate on small satellites and that are responsive to science objectives described in National Academy of Science Decadal Surveys. The advent of high capability small spacecraft enables consideration of science missions involving multiple small spacecraft, constellations of a few or many for simultaneous distributed in situ observations or remote observations from a variety of viewpoints. The central challenge for fielding instrumented space-flight constellations is to provide the required multiple sets of fully verified and calibrated instrument hardware, software, and operational processes from within a one-off project-based scientific space flight culture. Although there are numerous commercial entities providing “off-the shelf” spacecraft and avionics, the challenge lies in the multi-unit production of the uniquely targeted instrumentation necessary to perform the specific measurements required for a particular science investigation. Traditionally, the cost of such instrumentation has represented a significant portion of the hardware cost for a mission and posed the highest risk area for implementation. A shift in paradigm from large science platforms to constellations of smaller satellites drives the challenge to build instruments in a quasi-production environment. This paper describes key aspects of, and challenges encountered in the development program for the successful production of instruments for the Fast-Plasma Investigation (FPI) instrument suite of 64 flight plasma spectrometers and supporting electronics on the NASA Magnetospheric Multiscale (MMS) 4 satellite constellation mission. Although the MMS mission was not composed of small satellites, there are key aspects of the instrument production that apply directly to constellations of small satellites.

Arthur D Jacques↗