Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Mobile Measuring System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Propagation measurements for an Australian land mobile satellite system

Measurements of attenuation statistics using a helicopter and an instrumented van are discussed. Results are given for two different tree densities, for elevation angles of 30, 45 and 60 degrees and for frequencies of 893, 1550 and 2660 MHz. These results show that at 1550 MHz and 45 degrees elevation angle, attenuation values of 5.0 and 8.6 dB were exceeded 10 percent of the time for roadside tree densities of 35 percent and 85 percent respectively. Comparisons with other results made in the Northern Hemisphere are made and show general agreement. The implication of the measured values on system design are discussed, and it is shown that, for Australia, an adaptive margin allocation scheme would require an average margin of approximately 5 dB.

Bundrock, Anthony J.

Mobile satellite system propagation measurements at L-band using Marecs-B2

A mobile satellite system (MSS) propagation experiment at 1.5 GHz was performed near the east coast of the United States in central Maryland during December 1987 using the Marecs-B2 satellite as a transmitter platform. A receiving system in a vehicle measured signal fades caused by shadowing and multipath from roadside trees and utility poles. The propagation degradations were characterized for a system of three roads previously examined using a helicopter as the transmitter platform. The objectives of the Marecs-B2 MSS tests were to: (1) establish cumulative fade distributions for the particular satellite geometry for both rural and suburban roads; (2) validate the consistency of previous roadside tree measurements which employed a helicopter as the transmitter platform for the same system of roads; (3) obtain an additional set of fade levels at a lower angle hitherto not measured in central Maryland; and (4) combine the satellite-acquired data set with previous helicopter results and establish an analytic, empirically derived function describing the cumulative fade distributions for a family of path angles. An analysis of the satellite data has demonstrated the successful achievement of these objectives.

Vogel, Wolfhard J.

Integrated mobility measurement and notation system

System for description of movements and positions facilitates design of space suits with more mobility. This measurement and notation system gives concise and unequivocal descriptions, compatible with engineering analysis and applicable to specific needs.

Roebuck, J. A., Jr.

Wake flow measurements with a mobile laser Doppler velocimeter system

Wake flow measurements were conducted with a mobile laser Doppler velocimeter (LDV). The measurements included surveys of aircraft wake vortices behind a B-747 aircraft, aircraft carrier wake measurements from aboard the U.S.S. Nimitz, and tower wake measurements for a 100 kW wind turbine. Results of these tests demonstrated that a mobile ground-based LDV is a versatile and useful tool for the measurement of full-scale three-dimensional wake flows. The potential is demonstrated for utilization of this system to study complex wakes for a variety of applications.

Wilson, D. J.

Mobile lidar system for measurement of water vapor mixing ratio and ozone number density

The Water Vapor Lidar was modified and extended to make differential absorption measurements of ozone. Water vapor measurements make use of a weak molecular scattering process known as Raman scattering. It is characterized by a shift in wavelength of the scattered beam of light relative to the incident one. Some of the energy of the incident photon is converted to vibrational or rotational energy within the molecule leaving the scattered photon shifted to a slightly longer wavelength. When performing water vapor measurements, profiles are acquired of water vapor mixing ratio from near the ground to beyond 7 km every 2 minutes. By forming a color composite image of the individual profiles, the spatial and temporal evolution of water vapor is visible with vertical resolution of 75 to 150m and temporal resolution of 2 minutes. The ozone lidar is intended for use as a cross calibration facility for other stationary ozone lidar systems. The ozone measurement employs the technique known as differential absorption. The backscattered laser radiation from two different wavelengths is measured. Successful measurements of 308 nm returns were made from 80 km with an averaging period of 6 hours. Using these data and a standard atmosphere density curve, an ozone number density profile was made which agrees very well with the standard ozone curve between 20 and 40 km.

Whiteman, D.

Mobile very long baseline interferometry and Global Positioning System measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, Peter M.

Crustal dynamics project observing plan for highly mobile systems 1981 - 1986

Measurement of crustal motion in the western United States and other tectonically active regions makes use of fixed, movable and highly mobile satellite laser ranging and very long baseline interferometry systems. Measurement of the rotational dynamics of the Earth as well as regional deformation and plate motion are discussed.

Frey, H.

Geodetic measurements with a mobile VLBI system

The Project ARIES 9 meter transportable antenna was used as one element of very long baseline interferometer (VLBI) to begin monitoring locations of six sites in California relative to large diameter fixed antennas at the NASA Deep Space Network, Goldstone, California, and at the Caltech Owens Valley Radio Observatory, Big Pine, California. An accuracy of about 6 cm in the horizontal components was demonstrated by comparison with measurements of the National Geodetic Survey. The root of mean square scatter of the lengths of the baselines between any pair of antennas was about 3 cm except for the Goldstone-JPL (Pasadena) baseline. In the period August 1974 to August 1977 the length of this baseline increased by 15 + or - 5 cm as JPL moved westward relative to Goldstone at the rate of 6 + or - 2 cm/year. The baseline lengths were unaffected by the uncertainties of UT1, polar motion, and tropospheric water vapor, which are the limitations to present three dimensional vector accuracies.

Niell, A. E.

Planned LMSS propagation experiment using ACTS: Preliminary antenna pointing results during mobile operations

An overview and a status description of the planned LMSS mobile K band experiment with ACTS is presented. As a precursor to the ACTS mobile measurements at 20.185 GHz, measurements at 19.77 GHz employing the Olympus satellite were originally planned. However, because of the demise of Olympus in June of 1991, the efforts described here are focused towards the ACTS measurements. In particular, we describe the design and testing results of a gyro controlled mobile-antenna pointing system. Preliminary pointing measurements during mobile operations indicate that the present system is suitable for measurements employing a 15 cm aperture (beamwidth at approximately 7 deg) receiving antenna operating with ACTS in the high gain transponder mode. This should enable measurements with pattern losses smaller than plus or minus 1 dB over more than 95 percent of the driving distance. Measurements with the present mount system employing a 60 cm aperture (beamwidth at approximately 1.7 deg) results in pattern losses smaller than plus or minus 3 dB for 70 percent of the driving distance. Acceptable propagation measurements may still be made with this system by employing developed software to flag out bad data points due to extreme pointing errors. The receiver system including associated computer control software has been designed and assembled. Plans are underway to integrate the antenna mount with the receiver on the University of Texas mobile receiving van and repeat the pointing tests on highways employing a recently designed radome system.

Rowland, John R.

Gas dispersion measurements using a mobile Raman lidar system

The exploitation of natural gas resources to supply energy demands has resulted in the need to engineer pipelines and plants capable of handling extremely high pressures and throughputs. Consequently, more attention has been directed to evaluating the consequences of releases of material whether accidental or deliberate in nature. An important aspect of assessing the consequences of a release is an understanding of how gas disperses in the atmosphere over a wide range of release and atmospheric conditions. The most cost effective way of providing such information is through the development and use of reliable theoretical prediction methods. The need for some form of remote sensing device was identified. The various possibilities studied led to the conclusion that LIDAR (Light Detection And Ranging) offered the most suitable method. The system designed and built is described, and its recent use in monitoring operational ventings from a high pressure transmission system is discussed.

Houston, J. D.

Improved Techniques for Measuring Static Ground Wind Loads on the NASA Space Launch System Mobile Launcher 2

Vertical distribution of static ground wind loads was directly measured on Mobile Launcher ground support hardware to the NASA Space Launch System (SLS) at 1.75% scale in the Langley Research Center 14- by 22-Foot Subsonic Tunnel. Low-speed wind tunnel testing in the liftoff phase of flight was conducted for the SLS Block 1B family of rockets with their associated ground support systems. Improved methods for measuring and estimating static ground wind loads on the launch tower assembly are introduced in detail. A novel, distributed loads measurement technique is introduced and compared against lower-fidelity, previously utilized methods.

Ground Wind Loads

Roadside tree attenuation measurements at UHF for land mobile satellite systems

Tree attenuation results at 870 MHz are described for experiments conducted in October 1985 and March 1986 in Central Maryland. These experiments employed a helicopter as a source platform and a van with receiver and data acquisition instrumentation. Tree attenuation results were obtained for the cases in which the van was stationary and in motion. The experiments were performed for the purpose of providing the designers of planned land mobile satellite systems with important elements in the determination of link parameter requirements; namely, the expected fading statistics due to roadside trees for both mobile and stationary vehicles. Single tree attenuation results gave worst case median fades as high as 15 dB although roadside tree values were noted to produce fades in excess of 20 dB for small percentages of time. The cumulative fade distributions and their relative contributions as a function of path elevation angle, right side versus left side driving, and different road types are derived from the field measurements. Upon comparing the attenuations from bare deciduous trees (March 1986) with those due to trees in full foliage (October 1985), the increase in dB attenuations were, in general, less than 25 percent for the dynamic cases, and less than 40 percent for the worst case static configuration. This result demonstrates that the dominant fading is caused by the wooded tree branches as opposed to the leaves on these branches. The tail end of the observed fade distributions was observed to follow lognormal distributions with respect to dB attenuation.

Goldhirsh, Julius

Requirements for a mobile communications satellite system. Volume 3: Large space structures measurements study

This study report defines a set of tests and measurements required to characterize the performance of a Large Space System (LSS), and to scale this data to other LSS satellites. Requirements from the Mobile Communication Satellite (MSAT) configurations derived in the parent study were used. MSAT utilizes a large, mesh deployable antenna, and encompasses a significant range of LSS technology issues in the areas of structural/dynamics, control, and performance predictability. In this study, performance requirements were developed for the antenna. Special emphasis was placed on antenna surface accuracy, and pointing stability. Instrumentation and measurement systems, applicable to LSS, were selected from existing or on-going technology developments. Laser ranging and angulation systems, presently in breadboard status, form the backbone of the measurements. Following this, a set of ground, STS, and GEO-operational were investigated. A third scale (15 meter) antenna system as selected for ground characterization followed by STS flight technology development. This selection ensures analytical scaling from ground-to-orbit, and size scaling. Other benefits are cost and ability to perform reasonable ground tests. Detail costing of the various tests and measurement systems were derived and are included in the report.

Akle, W.

2022 Through April 2023 Corrective Measures Implementation and Interim Measures Annual Status Report: Summary of Biosparge System Operation and Maintenance, Interim Measures and Monitoring Mobile Launch Platform Rehabilitation Sites / Vehicle Assembly Building Area (Swmu 056) Kennedy Space Center, Florida

This report presents a summary of the Corrective Measures Implementation (CMI) and Interim Measure (IM) implementation activities that occurred from January 2022 through April 2023 at the Mobile Launch Platform Rehabilitation Sites (MLP)/Vehicle Assembly Building (VAB) Area, Solid Waste Management Unit 056 (SWMU 056), located at the John F. Kennedy Space Center, Florida. The following summaries briefly describe areas within SWMU 056 identified by historical site investigation activities where groundwater monitoring and remedial actions have been implemented to date.

VOCs