Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidic devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Aerosol jet printing of surface acoustic wave microfluidic devices

Abstract The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Protein and nucleic acid detection for microfluidic devices

The present invention relates to methods for detecting targets by employing a temperature control system with a microfluidic device. The system allows for non-contact heating by employing an infrared emitter. In some instances, the system can be used in conjunction with a centrifugal microfluidic device. Optionally, a mask can be implemented to provide selective heating of desired assay areas of the device.

Koh, Chung-Yan↗

Detection of active and latent infections with microfluidic devices and systems thereof

The present invention relates to methods of detecting one or more targets of interest in a sample. In one instance, the target can be correlated to an active infection (e.g., by a virus and/or a bacterium). Methods can include treating the sample with a dissociation agent, thereby releasing the target of interest for more accurate detection (e.g., by use of a sedimentation-based centrifugal microfluidic devices). Also described herein are microfluidic devices and systems for use with a dissociation agent.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring the Electrochemical Corrosion of 233U-doped UO2 in a Microfluidic Device

We have developed a microfluidic, ‘particle-attached microfluidic electrochemical’ device, or PAMEC, that uses microgram quantities of radioactive materials, such as uranium dioxide (UO2), rather than bulk specimens to both observe electrochemical changes and measure spectroscopic properties. The PAMEC device reduces the need for running experiments in a shielded facility and allows for in-operando, real-time investigations of electrochemical properties and morphological changes of micrograms of particles. This novel design offers a promising platform to investigate spent nuclear fuel (SNF) and other nuclear materials under various controlled condition, and to provide insights to nuclear waste management, and fuel performance

Electrochemistry↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated methods for scalable, parallelized enzymatic biopolymer synthesis and modification using microfluidic devices

Methods for the automated template-free synthesis of user-defined sequence controlled biopolymers using microfluidic devices are described. The methods facilitate simultaneous synthesis of up to thousands of uniquely addressed biopolymers from the controlled movement and combination of regents as fluid droplets using microfluidic and EWOD-based systems. In some forms, biopolymers including nucleic acids, peptides, carbohydrates, and lipids are synthesized from step-wise assembly of building blocks based on a user-defined sequence of droplet movements. In some forms, the methods synthesize uniquely addressed nucleic acids of up to 1,000 nucleotides in length. Methods for adding, removing and changing barcodes on biopolymers are also provided. Biopolymers synthesized according to the methods, and libraries and databases thereof are also described. Modified biopolymers, including chemically modified nucleotides and biopolymers conjugated to other molecules are described.

Banal, James↗

A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening

Mass spectrometry (MS) enables detection of different chemical species with a very high specificity; however, it can be limited by its throughput. Integrating MS with microfluidics has a tremendous potential to improve throughput and accelerate biochemical research. In this work, we introduce Drop-NIMS, a combination of a passive droplet loading microfluidic device and a matrix-free MS laser desorption ionization technique called nanostructure-initiator mass spectrometry (NIMS). This platform combines different droplets at random to generate a combinatorial library of enzymatic reactions that are deposited directly on the NIMS surface without requiring additional sample handling. The enzyme reaction products are then detected with MS. Drop-NIMS was used to rapidly screen enzymatic reactions containing low (on the order of nL) volumes of glycoside reactants and glycoside hydrolase enzymes per reaction. MS “barcodes” (small compounds with unique masses) were added to the droplets to identify different combinations of substrates and enzymes created by the device. We assigned xylanase activities to several putative glycoside hydrolases, making them relevant to food and biofuel industrial applications. Overall, Drop-NIMS is simple to fabricate, assemble, and operate and it has potential to be used with many other small molecule metabolites.

47 OTHER INSTRUMENTATION↗

Polymer-based microfluidic device for on-chip counter-diffusive crystallization and in situ X-ray crystallography at room temperature

Proteins are long chains of amino acid residues that perform a myriad of functions in living organisms, including enzymatic reactions, signalling, and maintaining structural integrity. Protein function is determined directly by the protein structure. X-ray crystallography is the primary technique for determining the 3D structure of proteins, and facilitates understanding the effects of protein structure on function. The first step towards structure determination is crystallizing the protein of interest. We have developed a centrifugally-actuated microfluidic device that incorporates the fluid handling and metering necessary for protein crystallization. Liquid handling takes advantage of surface forces to control fluid flow and enable metering, without the need for any fluidic or pump connections. Our approach requires only the simple steps of pipetting the crystallization reagents into the device followed by either spinning or shaking to set up counter-diffusive protein crystallization trials. The use of thin, UV-curable polymers with a high level of X-ray transparency allows for in situ X-ray crystallography, eliminating the manual handling of fragile protein crystals and streamlining the process of protein structure analysis. We demonstrate the utility of our device using hen egg white lysozyme as a model system, followed by the crystallization and in situ, room temperature structural analysis of the hub domain of calcium–calmodulin dependent kinase II (CaMKIIβ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-Dimensional Mass Spectrometric Imaging of Biological Structures Using a Vacuum-Compatible Microfluidic Device

Three-dimensional (3D) molecular imaging of biological structures is important for a wide range of research. In recent decades, secondary ion mass spectrometry (SIMS) has been recognized as a powerful technique for both two-dimensional (2D) and 3D molecular imaging. Sample fixations (e. g., chemical fixation and cryogenic fixation methods) are necessary to adapt biological samples to the vacuum condition in the SIMS chamber, which has been demonstrated to be non-trivial and less controllable, thus limiting the wider application of SIMS on 3D molecular analysis of biological samples. Our group recently developed in situ liquid SIMS that offers great opportunities for the molecular study of various liquids and liquid interfaces. In this work, we demonstrate that a further development of the vacuum-compatible microfluidic device used in in situ liquid SIMS provides a convenient freeze-fixation of biological samples and leads to more controllable and convenient 3D molecular imaging. The special design of this new vacuum-compatible liquid chamber allows an easy determination of sputter rates of ice, which is critical for calibrating the depth scale of frozen biological samples. Sputter yield of a 20 keV Ar 1800 + ion on ice has been determined as 1500 (± 8%) water molecules per Ar 1800 + ion, consistent with our results from molecular dynamics simulations. Moreover, using the information of ice sputter yield, we successfully conduct 3D molecular imaging of frozen homogenized milk and observe network structures of interesting organic and inorganic species. Finally, taken together, our results will significantly benefit various research fields relying on 3D molecular imaging of biological structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel two-layer-integrated microfluidic device for high-throughput yeast proteomic dynamics analysis at the single-cell level

Abstract Current microfluidic methods for studying multicell strains (e.g., m-types) with multienvironments (e.g., n-types) require large numbers of inlets/outlets (m*n), a complicated procedure or expensive machinery. Here, we developed a novel two-layer-integrated method to combine different PDMS microchannel layers with different functions into one chip by a PDMS through-hole array, which improved the design of a PDMS-based microfluidic system. Using this method, we succeeded in converting 2 × m × n inlets/outlets into m + n inlets/outlets and reduced the time cost of loading processing (from m × n to m) of the device for studying multicell strains (e.g., m-types) in varied multitemporal environments (i.e., n-types). Using this device, the dynamic behavior of the cell-stress-response proteins was studied when the glucose concentration decreased from 2% to a series of lower concentrations. Our device could also be widely used in high-throughput studies of various stress responses, and the new concept of a multilayer-integrated fabrication method could greatly improve the design of PDMS-based microfluidic systems.

Chen, Kaiyue↗

Characterization and application of a high-resolution microfluidic device in atmospheric ice nucleation research and integrated science teaching

Ambient ice-nucleating particles (INPs) represent an important subset of aerosol particles that facilitate heterogeneous formation of ice crystals in the atmosphere, which can impact Earth system and energy. In this work, we developed an affordable high-resolution platform to replicate atmospheric immersion freezing through the unique capabilities of microfluidics to measure INP concentration of known ice nucleation active materials, as well as high-latitude soil samples. The new instrument produced comparable and extended freezing efficiency data for a multitude of samples over the temperature range of -5 to -35 °C as compared to an existing freezing assay within known uncertainties. Moreover, the new assay was integrated into science teaching at a primarily undergraduate and Hispanic-serving institute, contributing to fostering a deeper understanding of ice nucleation processes among college students, instilling their enthusiasm for science, and addressing the critical need for a well-informed citizenry. Student research assistants were involved in both research and pedagogical development processes. Three students from our team visited the Pacific Northwest National Laboratory to help characterize physicochemical properties of our test samples and to test modeling of atmospheric ice nucleation using a box model as well as a global climate model (E3SM) for the regional-scale conditions over the North Slope of Alaska (NSA) and Southern Great Plains (SGP). We also assessed student learning experience via hands-on training, research processes, and development of educational materials. On pre- and post-participation surveys and in exit interviews, students reported personal growth as advancements in breadth of experience, research-related skill sets, and regarding their educational and career goals. They also affirmed that the methods enacted incorporated the NASA Minority University Research and Education Program (MUREP) STEM Engagement Best Practices.

58 GEOSCIENCES↗

CO2 hydrate crystal thickening, morphology, and Raman spectroscopy in a microfluidic device

Gas hydrates are a solid, crystalline form of water that often form at low temperatures and high pressures. Carbon dioxide (CO2) hydrates may form during carbon dioxide capture and storage (CCS) processes. These solid compounds may form in CO2 pipelines, potentially leading to a full blockage and process shutdown for plug removal. On the other hand, formation of CO2 hydrates may be desired for CO2 capture and separation. In either case, understanding the growth behavior and nature of the hydrates is vital to managing these CCS processes. Using a high-pressure, transparent microfluidic reactor, the crystalline film thickening of CO2 hydrates was observed and measured through visual microscopy and Raman spectroscopy. The impact of subcooling, pressure, and CO2 flow rate was investigated, and only CO2 flow rate was found to have a significant impact on the overall thickness of the film. Visual observations and Raman spectroscopy measurements confirmed that two distinct hydrate layers formed during thickening, one which was more porous than the other. The capillary-like channels in the porous layer indicated a mechanism for mass transfer of water through the hydrate layer. A model was developed based on this observation, and it was fit to the thickening data in order to obtain mass transfer coefficients. Results of this study can be applied to CO2 hydrate formation in pipelines and near porous media used for CO2 capture.

Wadsworth, Lindsey [Colorado School of Mines, Gold↗