Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Microelectrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Apparatus and method of inserting a microelectrode in body tissue or the like using vibration means

An arrangement for and method of inserting a glass microelectrode having a tip in the micron range into body tissue is presented. The arrangement includes a microelectrode. The top of the microelectrode is attached to the diaphragm center of a first speaker. The microelectrode tip is brought into contact with the tissue by controlling a micromanipulator. Thereafter, an audio signal is applied to the speaker to cause the microelectrode to vibrate and thereby pierce the tissue surface without breaking the microelectrode tip. Thereafter, the tip is inserted into the tissue to the desired depth by operating the micromanipulator with the microelectrode in a vibratory or non-vibratory state.

Feldstein, C.

Microelectrode Arrays for Electrochemical Cycling of Individual Battery Particles

The electrochemical characterization of battery materials is usually performed on porous electrodes containing conductive additives, binders, and ensembles of redox-active particles at densities as high as 10 15 cm –3 . These complex structures often obscure individual battery particles’ intrinsic properties, hindering insights into the fundamentals of battery electrochemistry. To address this challenge, we developed microelectrode arrays to enable the charge and discharge of individual battery particles in liquid electrolytes. In this Methods and Protocols paper, we describe the fabrication of the microelectrode array chips, the assembly of particles onto microelectrodes, and the different types of electrochemical techniques that can be used, including galvanostatic cycling, cyclic voltammetry, potentiostatic intermittent titration, and electrochemical impedance spectroscopy. We use micron-sized lithium cobalt oxide as a model system to showcase the reliability and versatility of single-particle electrochemical experiments enabled by our microelectrode array. In conclusion, we aim to provide a detailed description to promote future uses of microelectrode arrays in fundamental research of batteries and other electrochemical systems.

25 ENERGY STORAGE

Excursion of vibrating microelectrodes in tissue

The paper deals with a vibrating microelectrode holder consisting of a support rod attached to the cone of a miniature loudspeaker. This holder facilitates a microelectrode penetration into arterial wall tissue, eliminates surface dimpling, and relieves polarographic artifacts believed to be due to tissue compression. The paper presents construction and performance details of the electrode holder, and evaluates the extent of possible damage incurred during such vibration by measuring electrode motion relative to surrounding tissue in an excised segment of femoral artery in the rabbit. It is concluded that under proper vibratory conditions microelectrodes can be easily inserted into the arterial wall with minimum tissue disturbance.

Kanabus, E. W.

Longitudinally-vibrating surgical microelectrode

Microelectrode attached to cone of loudspeaker imparting longitudinal vibrations, penetrates relatively tough tissue of arterial walls easier and with more precise depth control because dimpling is eliminated. Vibrating microelectrode has been successfully used to make accurate oxygen-content measurements in arterial walls.

Feldstein, C.

Microelectrode-based technology for the detection of low levels of bacteria

A microelectrode-based electrochemical detection method was used for quantitation of bacteria in water samples. The redox mediator, benzoquinone, was used to accept electrons from the bacterial metabolic pathway to create a flow of electrons by reducing the mediator. Electrochemical monitoring electrodes detected the reduced mediator as it diffused out of the cells and produced a small electrical current. By using a combination of microelectrodes and monitoring instrumentation, the cumulative current generated by a particular bacterial population could be monitored. Using commercially available components, an electrochemical detection system was assembled and tested to evaluate its potential as an emerging technology for rapid detection and quantitation of bacteria in water samples.

Rogers, Tom D.

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology

The Use of Microelectrodes in Molten Salt Electrochemistry

Molten salts have attracted considerable interest as essential media for advanced high-temperature technologies, including molten salt reactors, thermal energy storage, high-temperature electrolysis, and pyrochemical processing. Their ability to remain stable in liquid form at elevated temperatures, combined with favorable thermophysical properties and wide electrochemical windows, makes them highly suitable for applications involving heat transfer, energy storage, and hightemperature electrochemical processing. However, despite these advantages, molten salts present challenges due to their chemically reactive nature at high-temperatures, especially in the presence of oxidizing impurities. Salt chemistry can fluctuate through interactions with impurities over time, or fuel burnup in the case of molten salt reactors, often leading to the dissolution of metal species. This dynamic environment not only results in complex redox behavior but also promotes corrosion, which is rarely uniform and frequently manifests as localized degradation driven by structural materials’ compositional differences, electrochemical imbalances, and microstructural susceptibilities.

Kim, Changkyu [University of Wisconsin-Madison, WI

Correlation Between Microscopic Current Fluctuations Observed at Ultra-Microelectrodes and Macroscopic Bulk Electrolysis Performance in Redox-Active Microemulsions

Microemulsions (μEs) have been proposed as redox flow battery (RFB) electrolytes that maximize ionic conductivity and charge capacity by synergizing two immiscible phases. However, charge transfer during electrolysis in μEs is poorly understood. Here, we show that ultramicroelectrode electrolysis of ferrocene-loaded μEs –20%, 60%, and 90% water - reveals stochastic current fluctuations. These are differentiated in the scanning electrochemical microscopy (SECM) geometry, where power spectral density analysis showed distinct changes in the frequency contributions. SECM in the substrate generation-tip collection mode showed that fluctuations arise under mass-transfer control. Significant differences in the diffusion coefficient of ferrocene species were deducted from SECM approach curves, suggesting phase transfer behavior. Using bulk electrolysis, we calculated the charge accessibility and cycling behavior in the μEs. A decrease in the stochastic behavior of the μEs seems to correlate to a higher accessibility and cycling performance, with the 90% water μE displaying the best reversibility and the 60% the lowest. Altogether, these results suggest that Marangoni-type convection driven by concentration gradients and/or μE restructuring during charge transfer play a role in the electrochemical performance of μEs. This presents opportunities for screening and diagnosing the performance of these emerging RFB electrolytes.

25 ENERGY STORAGE

Temperature dependence of the electrode kinetics of oxygen reduction at the platinum/Nafion interface - A microelectrode investigation

Results of a study of the temperature dependence of the oxygen reduction kinetics at the Pt/Nafion interface are presented. This study was carried out in the temperature range of 30-80 C and at 5 atm of oxygen pressure. The results showed a linear increase of the Tafel slope with temperature in the low current density region, but the Tafel slope was found to be independent of temperature in the high current density region. The values of the activation energy for oxygen reduction at the platinum/Nafion interface are nearly the same as those obtained at the platinum/trifluoromethane sulfonic acid interface but less than values obtained at the Pt/H3PO4 and Pt/HClO4 interfaces. The diffusion coefficient of oxygen in Nafion increases with temperature while its solubility decreases with temperature. These temperatures also depend on the water content of the membrane.

Parthasarathy, Arvind

Miniaturized multiplex label-free electronic chip for rapid nucleic acid analysis based on carbon nanotube nanoelectrode arrays

BACKGROUND: Reducing cost and time is the major concern in clinical diagnostics, particularly in molecular diagnostics. Miniaturization technologies have been recognized as promising solutions to provide low-cost microchips for diagnostics. With the recent advancement in nanotechnologies, it is possible to further improve detection sensitivity and simplify sample preparation by incorporating nanoscale elements in diagnostics devices. A fusion of micro- and nanotechnologies with biology has great potential for the development of low-cost disposable chips for rapid molecular analysis that can be carried out with simple handheld devices. APPROACH: Vertically aligned multiwalled carbon nanotubes (MWNTs) are fabricated on predeposited microelectrode pads and encapsulated in SiO2 dielectrics with only the very end exposed at the surface to form an inlaid nanoelectrode array (NEA). The NEA is used to collect the electrochemical signal associated with the target molecules binding to the probe molecules, which are covalently attached to the end of the MWNTs. CONTENT: A 3 x 3 microelectrode array is presented to demonstrate the miniaturization and multiplexing capability. A randomly distributed MWNT NEA is fabricated on each microelectrode pad. Selective functionalization of the MWNT end with a specific oligonucleotide probe and passivation of the SiO2 surface with ethylene glycol moieties are discussed. Ru(bpy)2+ -mediator-amplified guanine oxidation is used to directly measure the electrochemical signal associated with target molecules. SUMMARY: The discussed MWNT NEAs have ultrahigh sensitivity in direct electrochemical detection of guanine bases in the nucleic acid target. Fewer than approximately 1000 target nucleic acid molecules can be measured with a single microelectrode pad of approximately 20 x 20 microm2, which approaches the detection limit of laser scanners in fluorescence-based DNA microarray techniques. MWNT NEAs can be easily integrated with microelectronic circuitry and microfluidics for development of a fully automated system for rapid molecular analysis with minimum cost.

Carbon

Carbon-Nanotube-Based Electrodes for Biomedical Applications

A nanotube array based on vertically aligned nanotubes or carbon nanofibers has been invented for use in localized electrical stimulation and recording of electrical responses in selected regions of an animal body, especially including the brain. There are numerous established, emerging, and potential applications for localized electrical stimulation and/or recording, including treatment of Parkinson s disease, Tourette s syndrome, and chronic pain, and research on electrochemical effects involved in neurotransmission. Carbon-nanotube-based electrodes offer potential advantages over metal macroelectrodes (having diameters of the order of a millimeter) and microelectrodes (having various diameters ranging down to tens of microns) heretofore used in such applications. These advantages include the following: a) Stimuli and responses could be localized at finer scales of spatial and temporal resolution, which is at subcellular level, with fewer disturbances to, and less interference from, adjacent regions. b) There would be less risk of hemorrhage on implantation because nano-electrode-based probe tips could be configured to be less traumatic. c) Being more biocompatible than are metal electrodes, carbon-nanotube-based electrodes and arrays would be more suitable for long-term or permanent implantation. d) Unlike macro- and microelectrodes, a nano-electrode could penetrate a cell membrane with minimal disruption. Thus, for example, a nanoelectrode could be used to generate an action potential inside a neuron or in proximity of an active neuron zone. Such stimulation may be much more effective than is extra- or intracellular stimulation via a macro- or microelectrode. e) The large surface area of an array at a micron-scale footprint of non-insulated nanoelectrodes coated with a suitable electrochemically active material containing redox ingredients would make it possible to obtain a pseudocapacitance large enough to dissipate a relatively large amount of electric charge, so that a large stimulation current could be applied at a micron-scale region without exhausting the redox ingredients. f) Carbon nanotube array is more compatible with the three-dimensional network of tissues. Particularly, a better electrical-neural interface can be formed. g) A carbon nanotube array inlaid in insulating materials with only the ends exposed is an extremely sensitive electro-analysis tool that can measure the local neurotransmitter signal at extremely high sensitivity and temporal resolution.

Li, Jun

Toward Spatial Control of Reaction Selectivity on Photocatalysts Using Area-Selective Atomic Layer Deposition on the Model Dual Site Electrocatalyst Platform

Photocatalytic water splitting is a promising route to low-cost, green H 2 . However, this approach is currently limited in its solar-to-hydrogen conversion efficiency. One major source of efficiency loss is attributed to the high rates of undesired side and back reactions, which are exacerbated by the proximity of neighboring oxidation and reduction sites. Nanoscopic oxide coatings have previously been used to selectively block undesired reactants from reaching active sites; however, a coating encapsulating the entire photocatalyst particle limits activity as it cannot facilitate both half-reactions. In this work, area selective atomic layer deposition (AS-ALD) was used to selectively deposit semipermeable TiO 2 films onto model metallic cocatalysts for enhancing reaction selectivity while maintaining a high overall activity. Pt and Au were used as exemplary reduction and oxidation cocatalyst sites, respectively, where Au was deactivated toward ALD growth through self-assembled thiol monolayers while TiO 2 was coated onto Pt sites. Electroanalytical measurements of monometallic thin film electrodes showed that the TiO 2 -encapsulated Pt effectively suppressed undesired H 2 oxidation and Fe(II)/Fe(III) redox reactions while still permitting the desired hydrogen evolution reaction (HER). A planar model photocatalyst platform containing patterned interdigitated arrays of Au and Pt microelectrodes was further assessed using scanning electrochemical microscopy (SECM), demonstrating the successful use of AS-ALD to enable local reaction selectivity in a dual-reaction-site (photo)electrocatalytic system. Finally, interdigitated microelectrodes having independent potential control were used to show that selectively deposited TiO 2 coatings can suppress the rate of back reactions on neighboring active sites by an order of magnitude compared with uncoated control samples.

08 HYDROGEN

Rapid Electrochemical Detection and Identification of Microbiological and Chemical Contaminants for Manned Spaceflight Project

Microbial control in the spacecraft environment is a daunting task, especially in the presence of human crew members. Currently, assessing the potential crew health risk associated with a microbial contamination event requires return of representative environmental samples that are analyzed in a ground-based laboratory. It is therefore not currently possible to quickly identify microbes during spaceflight. This project addresses the unmet need for spaceflight-compatible microbial identification technology. The electrochemical detection and identification platform is expected to provide a sensitive, specific, and rapid sample-to-answer capability for in-flight microbial monitoring that can distinguish between related microorganisms (pathogens and non-pathogens) as well as chemical contaminants. This will dramatically enhance our ability to monitor the spacecraft environment and the health risk to the crew. Further, the project is expected to eliminate the need for sample return while significantly reducing crew time required for detection of multiple targets. Initial work will focus on the optimization of bacterial detection and identification. The platform is designed to release nucleic acids (DNA and RNA) from microorganisms without the use of harmful chemicals. Bacterial DNA or RNA is captured by bacteria-specific probe molecules that are bound to a microelectrode, and that capture event can generate a small change in the electrical current (Lam, et al. 2012. Anal. Chem. 84(1): 21-5.). This current is measured, and a determination is made whether a given microbe is present in the sample analyzed. Chemical detection can be accomplished by directly applying a sample to the microelectrode and measuring the resulting current change. This rapid microbial and chemical detection device is designed to be a low-cost, low-power platform anticipated to be operated independently of an external power source, characteristics optimal for manned spaceflight and areas where power and computing resources are scarce.

Pierson, Duane