Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “March 2007”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ROSSI X-RAY TIMING EXPLORER MONITORING OF THE ANOMALOUS X-RAY PULSAR 1E 1048.1 - 5937: LONG-TERM VARIABILITY AND THE 2007 MARCH EVENT

After three years of no unusual activity, Anomalous X-ray Pulsar 1E 1048.1 - 5937 reactivated in 2007 March. We report on the detection of a large glitch ({delta}{nu}/{nu} = 1.63(2) x 10{sup -5}) on 2007 March 26 (MJD 54185.9), contemporaneous with the onset of a pulsed-flux flare, the third flare observed from this source in 10 years of monitoring with the Rossi X-ray Timing Explorer (RXTE). Additionally, we report on a detailed study of the evolution of the timing properties, the pulsed flux, and the pulse profile of this source as measured by RXTE from 1996 July to 2008 January. In our timing study, we attempted phase-coherent timing of all available observations. We show that in 2001 a timing anomaly of uncertain nature occurred near the rise of the first pulsed flux flare; we show that a likely glitch ({delta}{nu}/{nu} = 2.91(9) x 10{sup -6}) occurred in 2002, near the rise of the second flare, and we present a detailed description of the variations in the spin down. In our pulsed flux study, we compare the decays of the three flares and discuss changes in the hardness ratio. In our pulse profile study, we show that the profile exhibited large variations near the peak of the first two flares, and several small short-term profile variations during the most recent flare. Finally, we report on the discovery of a small burst 27 days after the peak of the last flare, the fourth burst discovered from this source. We discuss the relationships between the observed properties in the framework of the magnetar model.

79 ASTRONOMY AND ASTROPHYSICS↗

White Sturgeon Mitigation and Restoration in the Columbia and Snake Rivers Upstream from Bonneville Dam; Annual Progress Report, April 2007 - March 2008.

We report on our progress from April 2007 through March 2008 on determining the effects of mitigative measures on productivity of white sturgeon populations in the Columbia River downstream from McNary Dam, and on determining the status and habitat requirements of white sturgeon populations in the Columbia and Snake rivers upstream from McNary Dam. The study is a cooperative effort by the Oregon Department of Fish and Wildlife (ODFW; Report A), Washington Department of Fish and Wildlife (WDFW; Report B), Columbia River Inter-Tribal Fish Commission (CRITFC; Report C), and Montana State University (MSU; Report D). This is a multi-year study with many objectives requiring more than one year to complete; therefore, findings from a given year may be part of more significant findings yet to be reported.

13 HYDRO ENERGY↗

Scale-Up of World Record 16.5% CdTe Cell Design for a 50 MWp Production Facility: September 27, 2007 - March 26, 2009

This final report covers progress made on subcontract NAT-7-77015-07 by PrimeStar Solar Inc. for the 18 month period from September 27, 2007 through March 26, 2009. The project objectives were to accelerate the commercialization of the world record 16.5% efficiency cadmium telluride photovoltaic technology. This was done by developing high performance 6'x6' prototype mini-modules and by designingand commissioning a pilot line for manufacturing of commercial sized 60cmx120cm modules. This subcontract aligns with the SAI program by accelerating the development of high efficiency low cost CdTe solar PV module manufacturing. This will contribute to the goal of PV grid parity by 2015. Progress with the deliverables and milestones in this subcontract constitutes progress towards the KPP andmilestone objectives for the SAI program.

14 SOLAR ENERGY↗

Advanced CdTe Photovoltaic Technology: September 2007 - March 2009

During the last eighteen months, Abound Solar (formerly AVA Solar) has enjoyed significant success under the SAI program. During this time, a fully automated manufacturing line has been developed, fabricated and commissioned in Longmont, Colorado. The facility is fully integrated, converting glass and semiconductor materials into complete modules beneath its roof. At capacity, a glass panel willenter the factory every 10 seconds and emerge as a completed module two hours later. This facility is currently undergoing trials in preparation for large volume production of 120 x 60 cm thin film CdTe modules. Preceding the development of the large volume manufacturing capability, Abound Solar demonstrated long duration processing with excellent materials utilization for the manufacture ofhigh efficiency 42 cm square modules. Abound Solar prototype modules have been measured with over 9% aperture area efficiency by NREL. Abound Solar demonstrated the ability to produce modules at industry leading low costs to NREL representatives. Costing models show manufacturing costs below $1/Watt and capital equipment costs below $1.50 per watt of annual manufacturing capacity. Under this SAIprogram, Abound Solar supported a significant research and development program at Colorado State University. The CSU team continues to make progress on device and materials analysis. Modeling for increased device performance and the effects of processing conditions on properties of CdTe PV were investigated.

14 SOLAR ENERGY↗

October 2008 monitoring results for Morrill, Kansas.

In September 2005, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) initiated periodic sampling of groundwater in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Morrill, Kansas. The sampling at Morrill is being performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE 2005), to monitor levels of carbon tetrachloride contamination identified in the groundwater at this site (Argonne 2004, 2005a). This report provides results for the most recent monitoring event, in October 2008. Under the KDHE-approved monitoring plan (Argonne 2005b), groundwater was initially sampled twice yearly for a period of two years (in fall 2005, in spring and fall 2006, and in spring and fall 2007). The samples were analyzed for volatile organic compounds (VOCs), as well as for selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. During the two-year period, the originally approved scope of the monitoring was expanded to include vegetation sampling (initiated in October 2006) and surface water and stream bed sediment sampling (initiated in March 2007, after a visual reconnaissance along Terrapin Creek [Argonne 2007a]). The analytical results for groundwater sampling events at Morrill in September 2005, March and September 2006, March and October 2007, and April 2008 were documented previously (Argonne 2006a,b, 2007b, 2008a,c). Those results consistently demonstrated the presence of carbon tetrachloride contamination, at levels exceeding the KDHE Tier 2 risk-based screening level (5.0 {micro}g/L) for this compound, in a groundwater plume extending generally south-southeastward from the former CCC/USDA facility, toward Terrapin Creek at the south edge of the town. Low levels ({le} 1.3 {micro}g/L) of carbon tetrachloride were persistently detected at monitoring well MW8S on the bank of an intermittent tributary to Terrapin Creek. This observation suggested a possible risk of contamination of the surface waters of the creek. That concern became the driving force for ongoing monitoring and consideration of possible remedial options for Morrill. In light of the early findings, in 2006 the CCC/USDA recommended expansion of the approved monitoring program to include the collection and analysis of surface water samples along Terrapin Creek (Argonne 2006a). At the request of the KDHE (2007a), locations for both surface water and shallow sediment sampling were discussed with the KDHE in January 2007. An addendum to the existing monitoring plan and a standard operating procedure (SOP AGEM-15) for sediment sampling were submitted to the KDHE on the basis of these discussions (Argonne 2007c,d). To supplement the original scope of the monitoring, Argonne also sampled natural vegetation along Terrapin Creek in October 2006, April 2007, and July 2007 for analyses for VOCs. The results of these plant tissue analyses were reported previously (Argonne 2008a). The October 2008 sampling event reported here represents a continuation of the two-year monitoring program, as requested by the KDHE (2007b). The groundwater sampling is presently conducted, in accord with the monitoring plan (Argonne 2005b) and the addendum to that plan (Argonne 2007a), in a network of 12 monitoring wells and 3 private wells (Figure 1.1), at locations approved by the KDHE.

54 ENVIRONMENTAL SCIENCES↗

Reconstruction of false spring occurrences over the southeastern United States, 1901 2007: an increasing risk of spring freeze damage?

Near-record warmth over much of the United States during March 2007 promoted early growth of crops and vegetation. A widespread arctic air outbreak followed in early April, resulting in extensive agricultural losses over much of the south-central and southeastern US. This false spring event also resulted in widespread damage to newly grown tissues of native deciduous forest species, shown by previous researchers to have had measurable effects on the terrestrial carbon cycle. The current study reconstructed the historical occurrence of false springs over most of the southeastern quarter of the conterminous US (32 39 N; 75 98 W) from 1901 to 2007 using daily maximum and minimum temperature records from 176 stations in the Global Historical Climatology Network database, and enhanced vegetation index (EVI) data derived from Moderate Resolution Imaging Spectroradiometer (MODIS) satellite observations. A false spring index was derived that examined the timing of the start of the growing season (SGS), or leaf emergence, relative to the timing of a potentially damaging last hard freeze (minimum temperature 2.2 C). SGS was modeled for the domain by combining EVI data with ground-based temperature degree day calculations reflecting the rate of springtime warming. No significant area-wide, long-term SGS trend was found; however, over much of a contiguous region stretching from Mississippi eastward to the Carolinas, the timing of the last hard freeze was found to occur significantly later, this change occurring along with increased frequency of false springs. Earlier last hard freeze dates and decreased frequency of false springs were found over much of the northwestern part of the study region, including Arkansas and southern Missouri.

54 ENVIRONMENTAL SCIENCES↗

Audit Report on "The Office of Science's Management of Information Technology Resources"

The Department of Energy's Office of Science (Science) and its facility contractors are aggressive users of information technology (IT) to support fundamental research in areas such as energy, environmental remediation and computational sciences. Of its $4 billion Fiscal Year 2008 budget, Science spent about $287 million to manage its IT program. This included cyber security activities, acquisition of hardware and software, and support service costs used to maintain the operating environments necessary to support the missions of the program. Prior Office of Inspector General reports have identified various issues with Science's management of its IT programs and resources. For instance, our report on Facility Contractor Acquisition and Management of Information Technology Hardware (DOE/IG-0768, June 2007) noted that the Science sites reviewed spent more than necessary when acquiring IT hardware. In another example, our review of The Department's Efforts to Implement Common Information Technology Services at Headquarters (DOE/IG-0763, March 2007) disclosed that Science's reluctance to adopt the Department of Energy Common Operating Environment (DOE-COE) at Headquarters contributed to the Department's inability to fully realize potential cost savings through consolidation and economies of scale. In light of the magnitude of the Office of Science IT program and previously identified program weaknesses, we initiated this audit to determine whether Science adequately managed its IT resources. Science had taken a number of actions to improve its cyber security posture and align its program to Federal requirements. Yet, our review disclosed that it had not taken some basic steps to enhance security and reduce costs. In particular, we found that: (1) For their non-scientific computing environments, all seven of the field sites reviewed (two Federal, five contractor) had implemented security configurations that were less stringent than those included in the Federal Desktop Core Configuration. This configuration was designed by the National Institute of Standards and Technology and its use was mandated by the Office of Management and Budget; (2) Although we previously highlighted weaknesses and recommended corrective actions, Science still had not fully established or enforced IT hardware standards for acquiring hardware such as desktop and laptop computers or related peripherals, contributing to significant unnecessary expenditures; and (3) While we have noted in a series of past reports that significant savings could be realized from aggregating demand for IT services and products across the enterprise, Science had not implemented a common infrastructure for users at its Federal sites and continued to maintain an IT environment independent of the Department's Common IT Operating Environment. The weaknesses identified were attributable, at least in part, to a lack of adequate policies and procedures for ensuring effective cyber security and hardware acquisition practices. In addition, Science had not effectively monitored the performance of its field sites to ensure that previously reported internal control weaknesses were addressed and had not implemented an appropriate mechanism to track its IT-related costs. Without improvements, Science may be unable to realize the benefits of improved security over its information systems, reduce costs associated with hardware acquisition, and lower IT support costs through consolidation of services. In particular, we determined that Science could potentially realize savings of more than $3.3 million over the next three years by better controlling hardware costs and implementing standards for certain equipment. Furthermore, Science could continue to pay for duplicative IT support services and fail to take advantage of opportunities to lower costs and apply potential savings to mission-related work. During the course of our audit work, we learned from Science officials that they had initiated the process of revising the Program Cyber Security Plan to better clarify its policy for implementing Federal cyber security requirements. In addition, we noted that the Oak Ridge National Laboratory had taken action to establish and enforce hardware standards on both its administrative and scientific workforce. Although these actions are positive steps, additional action is needed to strengthen Science's IT program. To that end, our report contains several recommendations that, if fully implemented, should help Science improve the management of its IT resources.

99 GENERAL AND MISCELLANEOUS↗

LATE-TIME DETECTIONS OF THE X-RAY AFTERGLOW OF GRB 060729 WITH CHANDRA-THE LATEST DETECTIONS EVER OF AN X-RAY AFTERGLOW

We report on five Chandra observations of the X-ray afterglow of the gamma-ray burst (GRB) 060729 performed between 2007 March and 2008 May. In all five observations, the afterglow is clearly detected. The last Chandra pointing was performed on 2008 May 4, 642 days after the burst-the latest detection of a GRB X-ray afterglow ever. A reanalysis of the Swift XRT light curve together with the three detections by Chandra in 2007 reveals a break at {approx}1.0 Ms after the burst with a slight steepening of the decay slope from alpha = 1.32 to 1.61. This break coincides with a significant hardening of the X-ray spectrum, consistent with a cooling break in the wind medium scenario, in which the cooling frequency of the afterglow crosses the X-ray band. The last two Chandra observations in 2007 December and 2008 May provide evidence for another break at about one year after the burst. If interpreted as a jet break, this late-time break implies a jet half-opening angle of {approx}14{sup 0} for a wind medium. Alternatively, this final break may have a spectral origin, in which case no jet break has been observed and the half-opening angle of the jet of GRB 060729 must be larger than {approx}15{sup 0} for a wind medium. We compare the X-ray afterglow of GRB 060729 in a wind environment with other bright X-ray afterglows, in particular GRBs 061121 and 080319B, and discuss why the X-ray afterglow of GRB 060729 is such an exceptionally long-lasting event.

79 ASTRONOMY AND ASTROPHYSICS↗

Remediation of the FGMSP at Sellafield: The First Transfer of Bulk Sludge - 17133

The very first bulk transfers of radioactive sludge have commenced from one of the most hazardous nuclear plants in Europe, using equipment and systems researched, designed, installed and commissioned by Jacobs as part of the ACKtiv alliance. Sellafield is a nuclear fuel reprocessing and decommissioning site, close to the village of Seascale on the coast of the Irish Sea in Cumbria, England. Sellafield incorporates the original nuclear reactor site at Windscale, which is currently undergoing decommissioning, and dismantling, and Calder Hall, the world's first nuclear power generating reactor. The first nuclear facilities were built in the 1940's.The First Generation Magnox Storage Pond (FGMSP) dates back to the 1950's as part of the UK's expanding nuclear programme and was constructed to store, cool and prepare used Magnox nuclear fuel for recycling into new fuel. It urgently needs to be emptied of 1500 cubic metres of radioactive sludge. In this paper we describe the work undertaken by Jacobs to deliver a very challenging programme of work to provide the capability to remove sludge from the pond. The FGMSP Retrievals Project was awarded in March 2007 to supply equipment and services for the removal of sludge and miscellaneous waste from the First Generation Magnox Storage Pond at Sellafield. The Project is being executed by ACKtiv Nuclear (Jacobs, Carillion and Atkins) of which Jacobs is a 40% stakeholder. ACKtiv Nuclear is a mature Joint Venture and has been operating continuously and successfully since 2002, the oldest JV still in operation on Sellafield Site. The roots of the JV can be traced back to the 1980's. The Project covers all project phases from front-end engineering through detailed design, procurement, installation and commissioning support. The Project places huge emphasis on off-Site testing and has several facilities for both installation and integrated testing. This proves equipment prior to installation in a radioactive environment. The Project has achieved success and recognition including winning the 2014 and 2015 Sellafield Business Excellence awards, as well as numerous internal Jacobs awards. The Project achieved a major decommissioning milestone in March 2016. Since the installation of a 31 m pipe-bridge in 2012, using a 1200 te mobile crane surrounded by several other facilities with nuclear inventory, the Project has successfully installed the sludge retrieval and effluent system into the FGMSP. This 4 year programme of work included 2 booster pump platforms, sludge recovery tooling, hoses, umbilicals and a deluge skip wash box which were all trialled and proven off-Site prior to installation in the pond. This milestone to commence transfer of sludge to modern stainless steel containment is a major step forward in the hazard reduction of the facility.The presentation will cover the installation of the pond de-sludging equipment, the innovations deployed that ensured that the milestone was achieved under budget and ahead of schedule, as well the benefits to the facility, the Site and the nuclear industry. It will also examine the challenges that needed to be overcome such as high dose, contamination, limited working times and space constraints. The presentation will describe why the work is of national Importance and conclude with the achievement of commencement of bulk sludge transfer to a modern facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Early Indicators of Treatment Success After Percutaneous Radiofrequency of Pulmonary Tumors

We retrospectively reviewed the imaging of patients after radiofrequency ablation (RFA) of lung metastases performed at our institution to assess the usefulness of ground glass opacification (GGO) margin for the prediction of complete tumor ablation. From January 2004 to March 2007, patients were identified where there was a postprocedure thin collimation scan to allow multiplanar reformatting, either immediately or at 24 h and at least 6 months of imaging follow-up. Thirty-six tumors in 22 patients were identified. The scans were assessed for the presence and width of GGO margin, and minimal and maximal dimensions were measured. A second reviewer, blinded to the outcome of the postprocedure assessment, reviewed the follow-up imaging for recurrence. The recurrence group had larger tumors (p = 0.045) and smaller mean minimal GGO margin width (p = 0.0001). Multivariate binary regression analysis confirmed that the minimal GGO margin was significantly (p < 0.005) associated with tumor recurrence. Receiver operator characteristic curve analysis suggests a cutoff of 4.5 mm for complete tumor ablation. There was substantial agreement ({kappa} = 0.759) between the site of absent GGO margin and the site of tumor recurrence. The point on the tumor surface where there is no GGO margin is likely to be the site of future recurrence. In our experience, a circumferential GGO margin of >5 mm is the minimal margion required to ensure complete tumor ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripheral Stent Placement in Hemodialysis Grafts

The purpose of the present study was to evaluate the clinical outcome of peripheral stent placement after failed balloon angioplasty in patients with grafts who are on hemodialysis. We examined 30 Wallstents that were placed in 26 patients because balloon angioplasty failed or early restenosis (<3 months) occurred within 3 months. We retrospectively reviewed 267 consecutive balloon angioplasties performed in 71 patients with graft access between August 2000 and March 2007. Stent placements accounted for 30 (11.2%) of the 267 balloon angioplasties. The clinical success rate of stent placement was 93.3% (28 of 30 stent placements). The 3-, 6-, and 12-month primary patency rates were 73.3%, 39.3%, and 17.7%, respectively. The 1-, 2-, and 3-year secondary patency rates were 90.2%, 83.8%, and 83.8%, respectively. Primary patency was significantly prolonged by stent placement after early restenosis compared with previous balloon angioplasty alone (P = 0.0059). Primary patency after stent placement was significantly lower than after successful balloon angioplasty without indications for stent placement (P = 0.0279). Secondary patency rates did not significantly differ between stent placement and balloon angioplasty alone. The mean number of reinterventions required to maintain secondary patency after stent placement was significantly larger than that after balloon angioplasty alone (Mann-Whitney U test, P = 0.0419). We concluded that peripheral stent placement for graft access is effective for salvaging vascular access after failed balloon angioplasty and for prolonging patency in early restenosis after balloon angioplasty. However, reinterventions are required to maintain secondary patency after stent placement. Furthermore, peripheral stent placement for graft access cannot achieve the same primary patency as balloon angioplasty alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 {+-} 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 {+-} 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 {+-} 4.7 months. Mean survival and freedom from any event was 66.7 {+-} 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P < 0.01). Patients in whom all aneurysm side branches were occluded prior to stent-grafting showed a significantly reduced incidence of large endoleaks. Endoleaks >10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks ({Delta} at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side branches reduced the incidence of large endoleaks. Large endoleaks significantly impaired aneurysm shrinkage, whereas small endoleaks did not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cholecystostomy as a First-Line Therapy in Chronic Hemodialysis Patients with Acute Cholecystitis with Midterm Follow-up

Purpose: The purpose of this article was to share midterm results of percutaneous cholecystostomy (PC) as a first-line therapy in chronic hemodialysis patients with acute cholecystitis. Methods: Fourteen chronic hemodialysis patients with acute cholecystitis underwent PC between March 2007 and May 2009 at our institute. On preoperative assessment, the patients were classified into the ASA score by the anesthesiology team. All patients were class IV because of severe underlying comorbidities. The patients were referred to interventional radiology unit for PC by consensus of the multidisciplinary team. Results: The PC was technically successful in all the patients without minor or major complications related to the procedure. Clinical symptoms in three patients who presented with sepsis and multiorgan failure did not resolve after PC, and these patients died following urgent surgery, including open cholecystectomy and common bile duct exploration. A new cholecystitis attack was detected in one patient in the acalculous group at the sixth month of the follow-up period. The mean catheterization time was 31.7 (range, 28-41) days. The mean follow-up time was 13.3 (range 4-21) months. Conclusions: The PC may come into consideration as a first-line treatment modality in the management of acute cholecystitis in poor surgical candidate chronic hemodialysis patients. This is the first report focusing on the midterm results of PC as a first-line therapy in hemodialysis patients with acute cholecystitis who could be operated on.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24-85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose-area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0-93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1-7). Mean fluoroscopy time was 161 (range 104-551) s, room time was 34 (range 15-79) min, mean DAP value was 25.9 (range 3.9-80.5) Gy{center_dot}cm{sup -2}, and interventional time was 18 (range 5-65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86-96), 100% (95% CI 82-100), 100% (95% CI 96-100), 66.7% (95% CI 55-83), and 91.7% (95% CI 86-96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors for Clinical Outcomes After Accelerated Partial Breast Intensity-Modulated Radiotherapy

Purpose: To correlate the treatment planning parameters with the clinical outcomes in patients treated with accelerated partial breast intensity-modulated radiotherapy. Methods and Materials: A total of 105 patients with Stage I breast cancer were treated between February 2004 and March 2007 in a Phase II prospective trial and had detailed information available on the planning target volume (PTV), ipsilateral breast volume (IBV), PTV/IBV ratio, lung volume, chest wall volume, surgery to radiotherapy interval, follow-up interval, breast pain, and cosmesis. The first 7 of these patients were treated to 34 Gy, and the remaining 98 were treated to 38.5 Gy. All patients were treated twice daily for 5 consecutive days. Univariate and multivariate analyses were performed. Results: The median follow-up was 13 months. No recurrences or deaths were observed. Of the 105 patients, 30 reported mild or moderate breast pain in their most recently recorded follow-up visit. The irradiated lung volume (p < 0.05) and chest wall volume receiving >35 Gy (p < 0.01) were associated with pain. The PTV, but not the PTV/IBV ratio, also correlated with pain (p < 0.01 and p = 0.42, respectively). A total of 72 patients reported excellent, 32 reported good, and 1 reported poor cosmesis. Physician-rated cosmesis reported 90 excellent and 15 good. None of the tested variables correlated with the cosmetic outcomes. Conclusion: Radiotherapy to the chest wall (chest wall volume receiving >35 Gy) and to lung correlated with reports of mild pain after accelerated partial breast intensity-modulated radiotherapy. Also, the PTV, but not the PTV/IBV ratio, was predictive of post-treatment reports of pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extrapulmonary Soft-Tissue Fibrosis Resulting From Hypofractionated Stereotactic Body Radiotherapy for Pulmonary Nodular Lesions

Purpose: To clarify the incidence, symptoms, and timing of extrapulmonary fibrosis developing after hypofractionated stereotactic body radiotherapy. Patients and Methods: We analyzed 379 consecutive patients who underwent stereotactic body radiotherapy for lung tumors at four institutions between February 2001 and March 2007. The median follow-up time was 29 months (range, 1-72). We investigated the subjective and objective characteristics of the extrapulmonary masses, redelineated the origin tissue of each on the treatment planning computed tomography scan, and generated dose-volume histograms. Results: In 9 patients (2.4%), extrapulmonary masses were found 3-36 months (median, 14) after irradiation. Coexisting swelling occurred in 3 patients, chest pain in 2, thumb numbness in 1, and arm edema in 1 patient. Extrapulmonary masses occurred in 5 (5.4%) of 92 and 4 (1.4%) of 287 patients irradiated with a 62.5-Gy and 48.0-Gy isocenter dose, respectively. The mean and maximal dose to the origin tissue was 25.8-53.9 Gy (median, 43.7) and 47.5-62.5 Gy (median, 50.2), respectively. In 5 of 9 patients, the standardized uptake values on 18F-fluorodeoxyglucose-positron emission tomography was 1.8-2.8 (median, 2.2). Percutaneous needle biopsy was performed in 3 patients, and all the specimens showed benign fibrotic changes without malignant cells. Conclusion: All patients should be carefully followed after stereotactic body radiotherapy. The findings of any new lesion should prompt an assessment for radiation-induced extrapulmonary fibrosis before an immediate diagnosis of recurrence is made. Careful beam-shape modification and dose prescription near the thoracic outlet are required to prevent forearm neuropathy and lymphedema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Chemoradiotherapy With 5-Fluorouracil and Mitomycin C for Anal Cancer in Immunocompetent Versus Immunodeficient Patients

Purpose: Information is limited as to how we should treat invasive anal squamous cell carcinoma (SCC) in patients with chronic immunosuppression, since the majority of clinical studies to date have excluded such patients. The objective of this study is to compare treatment outcomes in immunocompetent (IC) versus immunodeficient (ID) patients with invasive anal SCC treated similarly with combined modality therapy. Methods and Materials: Between January 1999 and March 2007, a total of 36 consecutive IC and ID patients received concurrent chemoradiotherapy using three-dimensional conformal radiotherapy with infusional 5-fluorouracil and mitomycin C. The IC and ID groups consisted of 19 and 17 patients, respectively, with 14 human immunodeficiency virus-positive (HIV+) and 3 post-solid organ transplant ID patients. There were no significant differences in tumor size, T stage, N stage, chemotherapy doses, or radiation doses between the two groups. Results: With a median follow-up of 3.1 years, no differences were found in overall survival, disease-specific survival, and colostomy-free survival. Three-year overall survival was 83.6% (95% CI = 68.2-100) and 91.7% (95% CI = 77.3-100) in the IC and ID groups, respectively. In addition, there were no differences in acute and late toxicity profiles between the two groups. In the human immunodeficiency virus-positive patients, Cox modeling showed no difference in overall survival by pretreatment CD4 counts (hazard ratio = 0.994, 95% CI = 0.98-1.01). No correlation was found between CD4 counts and the degree of acute toxicities. Conclusion: Our data suggest that standard combined modality therapy with three-dimensional conformal radiotherapy and 5-fluorouracil plus mitomycin C is as safe and effective for ID patients as for IC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗