Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MarCo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Scavenger receptor MARCO contributes to macrophage phagocytosis and clearance of tumor cells

Highlights: • The MARCO receptor on macrophages was positively correlated with the ability to phagocyte tumor cells. • Macrophage MARCO affects cytoskeleton rearrangement and pseudopodia formation through the SYK-PI3K-Rac1 pathway. • Integrin is the ligand of MARCO on the tumor cells. Macrophage receptor with collagenous structure (MARCO) is a member of the class A scavenger receptor family which is expressed on the cell surface of macrophages. It is well known that MARCO avidly binds to unopsonized pathogens, leading to its ingestion by macrophages. However, the role of MARCO in the recognition and phagocytosis of tumor cells by macrophages remains poorly understood. In this study, we used lentiviral technology to knockdown and overexpress MARCO and investigated the ability of macrophages to phagocytose tumor cells. Our results showed that MARCO expression was correlated with the ability of macrophages to carry on phagocytosis. MARCO knockdown led to significant decreases in the number of engulfment pseudopodia of macrophages and inhibition of the phagocytosis of tumor cells. On the other hand, MARCO overexpression elevated activity of SYK, PI3K and Rac1 in macrophages, which led to changes in macrophage morphology and enhanced phagocytosis by promoting formation of stress fibers and pseudopodia. By Co-IP analysis we showed that MARCO directly binds to the β5 integrin of SL4 tumor cells. In summary, these results demonstrated the important role for MARCO in demonstrated tumor cells uptake and clearance by macrophages.

60 APPLIED LIFE SCIENCES↗

Macrophage receptor with collagenous structure (MARCO) is a dynamic adhesive molecule that enhances uptake of carbon nanotubes by CHO-K1 Cells

The toxicity of carbon nanotubes (CNTs), a highly promising nanomaterial, is similar to that of asbestos because both types of particles have a fibrous shape and are biopersistent. Here, we investigated the characteristics of macrophage receptor with collagenous structure (MARCO), a membrane receptor expressed on macrophages that recognizes environmental or unopsonized particles, and we assessed whether and how MARCO was involved in cellular uptake of multi-walled CNTs (MWCNTs). MARCO-transfected Chinese hamster ovary (CHO-K1) cells took up polystyrene beads irrespective of the particle size (20 nm–1 μm). In the culture of MARCO-transfected CHO-K1 cells dendritic structures were observed on the bottom of culture dishes, and the edges of these dendritic structures were continually renewed as the cell body migrated along the dendritic structures. MWCNTs were first tethered to the dendritic structures and then taken up by the cell body. MWCNTs appeared to be taken up via membrane ruffling like macropinocytosis, rather than phagocytosis. The cytotoxic EC{sub 50} value of MWCNTs in MARCO-transfected CHO-K1 cells was calculated to be 6.1 μg/mL and transmission electron microscopic observation indicated that the toxicity of MWCNTs may be due to the incomplete inclusion of MWCNTs by the membrane structure. -- Highlights: ►Carbon nanotubes (CNTs) were tethered to MARCO in vitro. ►CNTs were taken up rapidly into the cell body via MARCO by membrane ruffling. ►The incomplete inclusion of CNTs by membranes caused cytotoxicity.

60 APPLIED LIFE SCIENCES↗

Design of MARCO, the New Solenoidal Detector Magnet for the ePIC Experiment at BNL

MARCO is the new superconducting solenoid for ePIC, the general-purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider at Brookhaven National Laboratory. Here, this 3.84 m long solenoid, with a bore diameter of 2.84 m, will provide a magnetic field of 2.0 T at the center with a nominal current of 4 kA at 4.5 K, for a total stored energy of 45 MJ. Its conductor is a NbTi Rutherford in Copper Channel (RICC), specially designed to stand the high mechanical loads induced by the magnetic field. Its copper stabilizer will assure the protection in case of quench. The coils are wound into six layers inside a thin external mandrel in brass, with a triple role of mechanical reinforcement, cryogenic support for the thermosiphon circuit and quench-back propagator. With a cold mass average radial thickness of just 7 cm, the magnet fulfills all the criterions of transparency for the particles directed to the hadronic calorimeter forecast around the cryostat. In this paper, the design of MARCO is presented, with a specific focus on the magnetic and quench analysis.

Calvelli, Valerio [Commissariat a l'Energie Atomiq↗

Wind speed data from NCEI Marcos A Gelabert station, Panama, Jan 2008 – Dec 2019

This data package contains wind speed data retrieved from the National Oceanic and Atmospheric Administration's National Center for Environmental Information (NCEI). Measurements were collected at the Marcos A. Gilbert airport in Panama City, Panama. This station can be considered as an analogue to the NGEE Tropics Parque Natural Metropolitano site in Panama. In the attached Excel file, wind speed units have been converted from MPH to m/s (1MPH = 0.447 m/s). Data from NCEI can be accessed at: https://gis.ncdc.noaa.gov/maps/ncei/, STATION NAME: MARCOS A GELABERT (Airport in Panama City). Within the attached zip file are three .csv data files, three PDF files containing an explanation of gap filling procedures and site information, and a read.me text file with metadata and instructions for accessing data from NCEI.

54 ENVIRONMENTAL SCIENCES↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Cryogenic Design and Thermal Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The Electron Ion Collider (EIC) physics program utilizes a 2.0 T superconducting magnet at the heart of its ePIC detector system. This approximately 3.5 m long and 2.84 m diameter warm bore magnet has a 20 tons cold mass which is conduction-cooled using liquid helium at 4.5 K. A closed loop active thermosiphon system is chosen to facilitate the cooling and to maintain a minimum of 2 K temperature margin on the peak operating temperature (4.7 K) of the superconductor. Here, this paper presents the cryogenic design of the cooling system and the thermal analysis of the solenoid. A Computational fluid dynamics (CFD) model was developed to quantify the performance of the two–phase closed thermosiphon system and predict the temperature gradient on the cold mass.

Gopinath, Sandesh [Thomas Jefferson National Accel↗

DOE Zero Energy Ready Home Case Study: KB Homes, San Marcos, California

Designed to produce as much energy as it uses, the ZeroHouse incorporates a PV system, R-15 fiberglass batts in walls, and slab-on-grade foundation. The builder ranked fifth in the nation on Builder Magazine’s 2012 Top 100 ranking of U.S. home builders based on number of housing starts, and won a 2013 Housing Innovation Award in the production builder category.

Building America↗

Comparison of Errors in Solar Power Plant Variability Simulation Methods

Four PV power plant variability simulation methods - no-smoothing, time average, Marcos, and the wavelet variability model (WVM) - were compared to measured data from a 19MW PV power plant to test the relative accuracy of each method. Errors (simulated vs. measured) were quantified using five application-specific metrics: the largest down ramps, the largest up ramps, the mean absolute error in matching the cumulative distribution of large ramps, the total energy contained in down ramps over the entire period considered, total energy in down ramps on the worst day. These errors we evaluated over timescales ranging from 1-second to 1-hour and over plant sizes of 1 to 14MW and the total plant size of 19MWs to determine trends in model errors as a function of timescale and plant size. Overall, the WVM was found to most often have the smallest errors. The Marcos method also often had small errors, including having the smallest errors of all methods at small PV plant sizes (1 to 7MWs). The no-smoothing method had large errors and should not be used. The time average method was an improvement over the no-smoothing method, but generally has larger errors than the WVM and Marcos methods.

14 SOLAR ENERGY↗

The harmonic oscillator and the position dependent mass Schroedinger equation: isospectral partners and factorization operators

One of the most important scientific contributions of Professor Marcos Moshinsky has been his study on the harmonic oscillator in quantum theory vis a vis the standard Schroedinger equation with constant mass [1]. However, a simple description of the motion of a particle interacting with an external environment such as happen in compositionally graded alloys consist of replacing the mass by the so-called effective mass that is in general variable and dependent on position. Therefore, honoring in memoriam Marcos Moshinsky, in this work we consider the position-dependent mass Schrodinger equations (PDMSE) for the harmonic oscillator potential model as former potential as well as with equi-spaced spectrum solutions, i.e. harmonic oscillator isospectral partners. To that purpose, the point canonical transformation method to convert a general second order differential equation (DE), of Sturm-Liouville type, into a Schroedinger-like standard equation is applied to the PDMSE. In that case, the former potential associated to the PDMSE and the potential involved in the Schroedinger-like standard equation are related through a Riccati-type relationship that includes the equivalent of the Witten superpotential to determine the exactly solvable positions-dependent mass distribution (PDMD)m(x). Even though the proposed approach is exemplified with the harmonic oscillator potential, the procedure is general and can be straightforwardly applied to other DEs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Species-specific acoustic responses by bats to ultrasonic stimuli used for reducing bat-wind turbine interactions

An unintended consequence of wind energy generation is bat fatalities caused by wind turbine blade strikes. One potential approach to reduce collision risk is to use ultrasound to create an uncomfortable or disorienting airspace around wind turbine blades. Ultrasonic deterrents (UDs) have produced mixed results in experimental field studies at commercial wind energy facilities, with effectiveness varying by species and location. It is possible that some species can alter their normal echolocation characteristics to counter the signal of UDs. Our broad objective was to maximize the effectiveness of a UD by comparing changes in echolocation characteristics during three UD frequency emissions among species, between seasons, and between sex. We hypothesized that UD emissions with frequencies most similar to each species’ echolocation characteristics would be more likely to alter the bats’ echolocation, and bat responses would vary between seasons and sex for each species. We released wild-captured bats into a 60 m × 10 m × 4.4 m (length × width × height) flight cage located in San Marcos, Texas, USA, from July to October 2020 and March to May 2021 and monitored echolocation frequencies with ultrasonic microphones. We conducted trials on Brazilian free-tailed bats ( Tadarida brasiliensis ; n = 54), cave myotis ( Myotis velifer ; n = 44), red bats ( Lasiurus blossevilli , Lasiurus borealis ; n = 41), evening bats ( Nycticeius humeralis ; n = 32), and tricolored bats ( Perimyotis subflavus ; n = 8). We found that species with high-frequency echolocation calls altered their echolocation signatures more commonly during high-frequency UD emissions, whereas low-frequency bats altered their echolocation signatures more commonly during low-frequency UD emissions. Additionally, echolocation responses varied between seasons and sexes for several species. Variations in responses may be dependent on species migratory status, differences in mating behavior and mating season, hormonal differences between sexes and seasons, and/or constraints on echolocation adaptability. Our results offer insights into the variable effectiveness of UDs at reducing bat fatalities at wind turbines and provide information for potential adjustments to UDs for improved success.

17 WIND ENERGY↗

THE ORIGIN OF ASTEROID 162173 (1999 JU{sub 3})

Near-Earth asteroid (162173) 1999 JU{sub 3} (henceforth JU{sub 3}) is a potentially hazardous asteroid and the target of the Japanese Aerospace Exploration Agency's Hayabusa-2 sample return mission. JU{sub 3} is also a backup target for two other sample return missions: NASA's OSIRIS-REx and the European Space Agency's Marco Polo-R. We use dynamical information to identify an inner-belt, low-inclination origin through the {nu}{sub 6} resonance, more specifically, the region with 2.15 AU < a < 2.5 AU and i < 8 Degree-Sign . The geometric albedo of JU{sub 3} is 0.07 {+-} 0.01, and this inner-belt region contains four well-defined low-albedo asteroid families (Clarissa, Erigone, Polana, and Sulamitis), plus a recently identified background population of low-albedo asteroids outside these families. Only two of these five groups, the background and the Polana family, deliver JU{sub 3}-sized asteroids to the {nu}{sub 6} resonance, and the background delivers significantly more JU{sub 3}-sized asteroids. The available spectral evidence is also diagnostic; the visible and near-infrared spectra of JU{sub 3} indicate it is a C-type asteroid, which is compatible with members of the background, but not with the Polana family because it contains primarily B-type asteroids. Hence, this background population of low-albedo asteroids is the most likely source of JU{sub 3}.

79 ASTRONOMY AND ASTROPHYSICS↗

CDF's New Results for ICHEP, New D0 results for ICHEP

Tom Wright and Marco Verzocchi of the Collider Detector at Fermilab (CDF) present data and observations from current work relating to high-energy physics and specifically the D0 Experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling constant metamorphosis, the Staeckel transform and superintegrability

This paper is dedicated to the memory of Marcos Moshinsky. In this paper, we discuss the important role that coupling constant metamorphosis (CCM) and the Staeckel transform have played in the analysis of superintegrable systems. We explain the relation between the two and in particular show that they coincide when transforming between second-order superintegrable systems. Unlike in the case of second-order superintegrability, the quantum analog of CCM has only been proven for a subclass of systems with integrals of a specific form. We give the proof and as an application show the mapping of a family of superintegrable deformations of the simple harmonic oscillator to an associated family of superintegrable deformations of the Kepler-Coulomb potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Some properties of an infinite family of deformations of the harmonic oscillator

In memory of Marcos Moshinsky, who promoted the algebraic study of the harmonic oscillator, some results recently obtained on an infinite family of deformations of such a system are reviewed. This set, which was introduced by Tremblay, Turbiner, and Winternitz, consists in some Hamiltonians H{sub k} on the plane, depending on a positive real parameter k. Two algebraic extensions of H{sub k} are described. The first one, based on the elements of the dihedral group D{sub 2k} and a Dunkl operator formalism, provides a convenient tool to prove the superintegrability of H{sub k} for odd integer k. The second one, employing two pairs of fermionic operators, leads to a supersymmetric extension of H{sub k} of the same kind as the familiar Freedman and Mende super-Calogero model. Some connection between both extensions is also outlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The harmonic oscillator behind all aberrations

The group-theoretical structure of the harmonic oscillator appears in many guises. Originally developed by Marcos Moshinsky among several others for applications in nuclear physics, we point out here that the harmonic oscillator structure appears in aberrations of geometric optics, particularly in their classification by rank, symplectic spin and weight. And further, the finite harmonic oscillator appears again in the nonlinear transformations of finite Hamiltonian systems, when applied to the parallel processing of signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗