Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Magnetometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spaceborne magnetometry

Low orbit (160 km altitude) satellite magnetometry is discussed. Magnetic field simulations and theoretical analyses were performed. They suggest that at 160 km, resolution value is 10, compared to 0.6 for Magsat, and that the satellite can reveal significant information on crustal tectonics. Vector and scalar magnetometers should be carried.

Taylor, P. T.

Mercury's Surface Magnetic Field Determined from Proton-Reflection Magnetometry

Solar wind protons observed by the MESSENGER spacecraft in orbit about Mercury exhibit signatures of precipitation loss to Mercury's surface. We apply proton-reflection magnetometry to sense Mercury's surface magnetic field intensity in the planet's northern and southern hemispheres. The results are consistent with a dipole field offset to the north and show that the technique may be used to resolve regional-scale fields at the surface. The proton loss cones indicate persistent ion precipitation to the surface in the northern magnetospheric cusp region and in the southern hemisphere at low nightside latitudes. The latter observation implies that most of the surface in Mercury's southern hemisphere is continuously bombarded by plasma, in contrast with the premise that the global magnetic field largely protects the planetary surface from the solar wind.

loss cone

FORWARD: A Toolset for Multiwavelength Coronal Magnetometry

Determining the 3D coronal magnetic field is a critical, but extremely difficult problem to solve. Since different types of multiwavelength coronal data probe different aspects of the coronal magnetic field, ideally these data should be used together to validate and constrain specifications of that field. Such a task requires the ability to create observable quantities at a range of wavelengths from a distribution of magnetic field and associated plasma i.e., to perform forward calculations. In this paper we describe the capabilities of the FORWARD SolarSoft IDL package, a uniquely comprehensive toolset for coronal magnetometry. FORWARD is a community resource that may be used both to synthesize a broad range of coronal observables, and to access and compare synthetic observables to existing data. It enables forward fitting of specific observations, and helps to build intuition into how the physical properties of coronal magnetic structures translate to observable properties. FORWARD can also be used to generate synthetic test beds from MHD simulations in order to facilitate the development of coronal magnetometric inversion methods, and to prepare for the analysis of future large solar telescope data.

Sun: magnetic fields

Lunar magnetometry and mantle convection

Lunar magnetometer data was used to indicate a lunar thermal boundary layer which is no more than 200 km thick and a lunar interior which is relatively isothermal. A direct comparison of temperature profiles with the experimental observations is used. It is assumed that the significant variation in lunar electrical conductivity is due to temperature alone and that it may be written in exponential form with a fixed and unknown activation energy and normalization constant. Experimental values of the lunar transfer function compared to theoretical curves generated by several temperature profiles show a significant temperature gradient only in the very outer portion of the moon. The steep curve of the variation of the transfer function with frequency implies an increase in electrical conductivity of no more than one order of magnitude with a depth between 1565 and 1000 km.

Kuckes, A. F.

Differences in elasticity of vinculin-deficient F9 cells measured by magnetometry and atomic force microscopy

We have investigated a mouse F9 embryonic carcinoma cell line, in which both vinculin genes were inactivated by homologous recombination, that exhibits defective adhesion and spreading [Coll et al. (1995) Proc. Natl. Acad. Sci. USA 92, 9161-9165]. Using a magnetometer and RGD-coated magnetic microbeads, we measured the local effect of loss and replacement of vinculin on mechanical force transfer across integrins. Vinculin-deficient F9Vin(-/-) cells showed a 21% difference in relative stiffness compared to wild-type cells. This was restored to near wild-type levels after transfection and constitutive expression of increasing amounts of vinculin into F9Vin(-/-) cells. In contrast, the transfection of vinculin constructs deficient in amino acids 1-288 (containing the talin- and alpha-actinin-binding site) or substituting tyrosine for phenylalanine (phosphorylation site, amino acid 822) in F9Vin(-/-) cells resulted in partial restoration of stiffness. Using atomic force microscopy to map the relative elasticity of entire F9 cells by 128 x 128 (n = 16,384) force scans, we observed a correlation with magnetometer measurements. These findings suggest that vinculin may promote cell adhesions and spreading by stabilizing focal adhesions and transferring mechanical stresses that drive cytoskeletal remodeling, thereby affecting the elastic properties of the cell.

Non-NASA Center

Evidence for a Second Martian Dynamo from Electron Reflection Magnetometry

Present-day Mars does not possess an active core dynamo and associated global magnetic field. However, the discovery of intensely magnetized crust in Mars Southern hemisphere implies that a Martian dynamo has existed in the past. Resolving the history of the Martian core dynamo is important for understanding the evolution of the planet's interior. Moreover, because the global magnetic field provided by an active dynamo can shield the atmosphere from erosion by the solar wind, it may have influenced past Martian climate. Additional information is included in the original extended abstract.

Lillis, R. J.

Remote Detection Sodium Cell Magnetometry Using Amplitude Modulated Light

We have investigated the performance of a remote-detection sodium cell magnetometer using synchronous optical pumping with amplitude modulated light. The magnetometer is used to measure ambient geomagnetic field with high-sensitivity using backscattered resonance fluorescence.

Line shapes and shifts and Spectroscopy

Seismoball: A Small Europa Orbiter Drop-Off Probe for Early Exploration of the Europan Surface

Recent magnetometry data received from Galileo indicate that the most likely explanation for the magnetic signature there is indeed a global conducting layer below the surface. This conducting layer is well matched by a salty, mineral rich strata beneath the Europan ice crust or a salt water ocean. Galileo imaging results show a variety of terrain types thought to contain young material; for example, lineaments, chaotic terrain, and eruption features. Additionally, Galileo images have shown indications of areas of up-welling where subsurface material periodically gets pushed to the surface due to the forces of fracturing, butting, and refreezing of the ice sheet. While Europa Orbiter will provide close-flyby high resolution images, as well as magnetometry, spectroscopy and other remote sensing data of the surface, it will not be able to provide essential engineering data like surface hardness and surface ice structure needed to support eventual landed missions. Additionally, ice chemical composition at microscopic scales can only be studied in detail through in situ instrumentation. Seismoball is a small probe designed to be injected into a surface intersect orbit around Europa. Using small reverse thrusters, the probe will be capable of nulling the high horizontal injection velocity as it approaches the 2 km surface injection altitude, thus allowing it to fall to the surface at an impact velocity of < 100m/sec (much less than the DS-2 impact velocities). The external breakaway thruster structure and crushable exterior shell absorb the impact energy while allowing the science instrument suite to remain intact. JPL has already started analyzing the entry dynamics and designing/building a small, low mass probe which will withstand the impact g-forces and fit as a 'carry-on' on board the Europa Orbiter. The probe will carry a suite of 5-6 micro-instruments for imaging the surface (both microscopic and far-field), surface and shallow subsurface ice temperatures, surface hardness, crustal dynamics and periodicity, and compositional chemistry. If selected, this flight development activity will provide a unique science opportunity and adjunct to the primary Orbiter science mission. The final flight system will be designed to accommodate orbiter mass, volume, and power interface constraints, as well as entry dynamics, g-load mitigation, and arbitrary landing orientation.

Tamppari, L.

Paleomagnetic Analysis Using SQUID Microscopy

Superconducting quantum interference device (SQUID) microscopes are a new generation of instruments that map magnetic fields with unprecedented spatial resolution and moment sensitivity. Unlike standard rock magnetometers, SQUID microscopes map magnetic fields rather than measuring magnetic moments such that the sample magnetization pattern must be retrieved from source model fits to the measured field data. In this paper, we presented the first direct comparison between paleomagnetic analyses on natural samples using joint measurements from SQUID microscopy and moment magnetometry. We demonstrated that in combination with apriori geologic and petrographic data, SQUID microscopy can accurately characterize the magnetization of lunar glass spherules and Hawaiian basalt. The bulk moment magnitude and direction of these samples inferred from inversions of SQUID microscopy data match direct measurements on the same samples using moment magnetometry. In addition, these inversions provide unique constraints on the magnetization distribution within the sample. These measurements are among the most sensitive and highest resolution quantitative paleomagnetic studies of natural remanent magnetization to date. We expect that this technique will be able to extend many other standard paleomagnetic techniques to previously inaccessible microscale samples.

Weiss, Benjamin P.

Scalar Atomic Defect-Based Solid-State Self-calibrating Magnetometer (3SM) for Space Plasma Analysis

The Earth’s magnetosphere is a system of multiple, co-located particle populations interacting via plasma waves. Things to understand are driving processes, radiation belt and ring current issues, auroral physics, internal plasma processes, and magnetosphere-ionosphere mapping issues. These plasma-physics processes enable the Earth’s magnetosphere to evolve in response to temporal changes in the solar wind and they underlie the phenomena of space weather, which impacts spacecraft systems, astronauts, radio communications, and ground based electric-power grids. The objective of 3SM is to measure magnetic field strength and to calibrate the Vector Magnetometer (VM) device to maintain absolute accuracy during a mission. The 3SM features make the instrument preferably suited not only for the traditional role of scalar magnetometers as absolute references for the calibration of the on-board vector instruments, but also for extended operational capacities, such as higher frequency scalar measurements (of potential interest for magnetosphere studies for the low frequency part of the spectrum) or autonomous scalar / vector operations. Diamond has been the solid-state platform of choice for quantum device technologies for some time, however, it suffers from difficulties such as scalability, integration, and cost. While the diamond platform is very useful for quantum technologies, further development is needed to make it viable. The material platform of choice for NASA Glenn’s Quantum Sensing And Spin Physics (Q-SASP) is silicon carbide (SiC). This is due to the much higher industry development of the SiC material platform for high-power and high-temperature electronics. It leverages both the decades-long SiC development expertise and infrastructure at NASA Glenn and its growing capabilities in quantum metrology. To make SiC devices usable for quantum technologies such as quantum sources, a much deeper understanding of defects is needed. Q-SASP is developing quantum metrology capabilities to evaluate the energy structure, defect formation energy, band structure augmentation, generation/recombination rates, and limits of dipole-dipole coupling in non-metal implanted SiC devices. This can be achieved by analysis of zero-field splitting, low-field resonance, and singlet-triplet mixing through various forms of Electrically Detectable Magnetic Resonance (EDMR) and Near-Zero Field Magnetic Resonance (NZFMR) spectroscopy. This work will discuss recent system developments, device developments, computational modeling, and spectroscopy results and analysis of defects created by non-metal implantations in SiC devices. The defect formation energies of V Si ,V C , V C V Si , N C V Si , N Si , N C in 4H-SiC are previously reported values in other research [2]-[3]. The defect formation energies of PSi and PC were calculated in GPAW [fig 1A]. The basic underlying mechanism of the zero-field phenomenon is the mixing of singlet and triplet states [4]-[5]. In most spin-dependent transport, two electron spins are involved, and thus one must consider each of their interactions with the field. We investigated the electronic and magnetic properties of 4H-SiC and 6H-SiC. The defect formation energy helps us determine what types of defects we are observing in the SiC EDMR experiment. They have very low formation energy (it is negative). The phosphorus substitution in 4H-SiC is a very stable defect. The band diagrams provide us with vital information about how the electronic properties of SiC (such as band gap) change as we add non-metal defects. The zero-field splitting parameters allow us to study the inflection point in the NZFMR [fig 1B]. We clearly observed zero-field splitting. We also noted that the zero-field splitting remained constant with changing bias. We aspect it zero-field splitting to remain constant while the hyperfine and exchange interaction perturbations shift under the influence of an external magnetic field. This is the essence of quantum magnetometry and self-calibration.

space plasma

Perform a gyro test of general relativity in a satellite and develop associated control technology

The progress accomplished in the Stanford Gyro Relativity program during the period November 1974 to October 1975 was described. Gyro developments were continued in the main laboratory dewar, concentrating on the operation of a three axis gyro readout and on improvements to the methods of canceling trapped fields in the rotor; these efforts culminated in the first successful observation of the London moment in the spinning gyro rotor in March 1975. Following a review meeting at that time, a new goal was formulated for the next 12 to 18 months, namely to operate a gyroscope in the new ultra-low field facility with readout resolution approaching 1 arc-second. The following other tasks were also completed: (1) sputtering work, (2) magnetometry, (3) construction and installation of the North Star simulator, (4) analysis of torques on the gyro, especially in inclined orbits, (5) equivalence principle accelerometer, and (6) analysis of a twin-satellite test of relativity.

Fairbank, W. M.

Measurement of lunar and planetary magnetic fields by reflection of low energy electrons

The paper describes the technique of planetary electron reflection magnetometry (PERM), a method for measuring the magnitude, direction, and scale size of magnetic fields near the surface of the moon and other planetary bodies with weak and small-scale-size surface fields. It is noted that the PERM technique is based on the ability of magnetic fields to reflect charged particles. A qualitative account of the implementation of the technique is presented along with some results obtained by the Apollo 15 and 16 Particles and Fields subsatellites. The quantitative aspects of PERM are treated by examining solutions to the equation of motion of a charged particle in a magnetic field, computing reflection coefficients on the basis of trajectory calculations, and determining the direction of the lunar surface magnetic field. The sensitivity of the PERM technique is calculated, and effects of lunar electric fields and spacecraft potentials on the measurements are described. Extension of the technique to Mars and Venus is discussed.

Anderson, K. A.

A vector autopilot system

Current technology has evolved low cost, highly reliable solid state vector magnetometers with excellent angular resolution. This paper discusses the role of a three-axis magnetometer as a new instrument for aircraft attitude determination. Using flight data acquired by an instrumented aircraft, attitude is calculated using the earth's magnetic field vector and compared to measured attitudes. The magnetic field alone is not adequate to resolve all attitude variations and the need for a second reference angle or vector is discussed. A system combining the functions of heading determination and attitude measurement is presented to show that both functions can be implemented with essentially the same component count required to measure heading alone. It is concluded that with the correlation achieved in calculated and measured attitude there is a potential application of vector magnetometry in attitude measurement systems.

Pietila, R.

Fiscal year 1976 progress report on a feasibility study evaluating the use of surface penetrators for planetary exploration

The feasibility of employing penetrators for exploring Mars was examined. Eight areas of interest for key scientific experiments were identified. These include: seismic activity, imaging, geochemistry, water measurement, heatflow, meteorology, magnetometry, and biochemistry. In seven of the eight potential experiment categories this year's progress included: conceptual design, instrument fabrication, instrument performance evaluation, and shock loading of important components. Most of the components survived deceleration testing with negligible performance changes. Components intended to be placed inside the penetrator forebody were tested up to 3,500 g and components intended to be placed on the afterbody were tested up to 21,000 g. A field test program was conducted using tentative Mars penetrator mission constraints. Drop tests were performed at two selected terrestrial analog sites to determine the range of penetration depths for anticipated common Martian materials. Minimum penetration occurred in basalt at Amboy, California. Three full-scale penetrators penetrated 0.4 to 0.9 m into the basalt after passing through 0.3 to 0.5 m of alluvial overburden. Maximum penetration occurred in unconsolidated sediments at McCook, Nebraska. Two full-scale penetrators penetrated 2.5 to 8.5 m of sediment. Impact occurred in two kinds of sediment: loess and layered clay. Deceleration g loads of nominally 2,000 for the forebody and 20,000 for the afterbody did not present serious design problems for potential experiments. Penetrators have successfully impacted into terrestrial analogs of the probable extremes of potential Martian sites.

Blanchard, M. B.

Multiple asteroid rendezvous missions

Asteroid missions, centered on multiple asteroid rendezvous missions to main belt asteroids, are discussed and the required solar electric propulsion for these missions as well as the current performance estimates are examined. A brief statistical analysis involving asteroid availability transfer requirements and propulsion system capabilities is given, leading to a prediction that 5 to 8 asteroids can be encountered with a single launch. Measurement techniques include visual imaging, radio tracking, magnetometry, and in the case of landers, seismometry. The spacecraft will be propelled by a solar electric system with a power level of 25 kW to 40 kW and tour possibilities for 13 different asteroids have been developed. Preliminary estimates of asteroid triaxiality are made to calculate the effect of close orbits.

Bender, D. F.

Galileo 1986 on Centaur

The mission, flight profile, instrumentation, and developmental program for the Galileo Jupiter probe, scheduled for Shuttle launch in 1986, are discussed. Gravity assists from each Galilean satellite at spacecraft periapsis will be used in order to configure for approaching the next satellite after a swingby past Jupiter. The process will continue for twenty months, and will yield data on the Jovian magnetosphere and tail, as well as on the satellites. A probe will be released 150 days from Jupiter orbit, followed by a course adjustment for the main instrumentation payload. The dual-spin spacecraft will proceed on its mission and act as a relay for the atmospheric entry probe, which is expected to broadcast data for one hour. Instrumentation on the Galileo will perform imaging, IR and UV spectrometry, radiometry, magnetometry, particle and dust detection, as well as plasma measurements, and celestial mechanics and radio propagation experiments. The direct trajectory to Jupiter, including a plane change maneuver, will be powered by a Centaur upper stage, and will encompass a journey taking over two years. The key constraints on the satellite tour are propellant and radiation tolerance.

Diaz, A.