Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic susceptibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnetization and magnetic susceptibility of DyH3

The magnetization and differential magnetic susceptibility of powdered DyH3 samples are measured at a temperature of 4.2 K in applied magnetic fields ranging up to 9 Teslas. The differential magnetic susceptibility is also investigated in the zero applied field. Magnetization is plotted as a function of field strength, and differential susceptibility is described as a function of both field strength and temperature. A saturation magnetic moment of 5.12 Bohr magnetons per ion is derived from the magnetization data, and the zero-field susceptibility measurements are found to indicate antiferromagnetic ordering below 3.45 K. The susceptibility at 4.2 K is shown to have an inverse-square dependence on field strength for values of not less than 0.3 Tesla.

Flood, D. J.↗

Magnetization and magnetic susceptibility of DyH3

The magnetization and differential magnetic susceptibility of powdered samples of DyH3 have been measured at 4.2 K in applied magnetic fields ranging to 9 Teslas. The differential magnetic susceptibility has also been studied in zero applied field as a function of temperature. The magnetization data are described by an equation of the form M = aB/(1 + bB + cB. The ratio a/b is a measure of the saturation magnetization and gives an effective moment of 5.12 Bohr magnetons per ion. The zero field susceptibility exhibits a maximum at T = 3.45 K, and an inflection point near 2.85 K. The susceptibility at 4.2 K has a 1/B squared dependence on the applied magnetic field for B approximately greater than 0.3 Teslas.

Flood, D. J.↗

Magnetic Susceptibility Measurements for in Situ Characterization of Lunar Soil

Magnetic separation is a viable method for concentration of components of lunar soils and rocks for use as feedstocks for manufacture of metals, oxygen, and for recovery of volatiles such as He-3. Work with lunar materials indicates that immature soils are the best candidates for magnetic beneficiation. The magnetic susceptibility at which selected soil components such as anorthite, ilmenite, or metallic iron are separated is not affected by soil maturity, but the recovery of the concentrated components is. Increasing soil maturity lowers recovery. Mature soils contain significant amounts of glass-encased metallic iron. Magnetic susceptibility, which is sensitive to metallic iron content, can be used to measure soil maturity. The relationship between the ratio of magnetic susceptibility and iron oxide and the conventional maturity parameter, I(sub s)/FeO, ferromagnetic resonant intensity divided by iron oxide content is given. The magnetic susceptibilities were determined using apparatus designed for magnetic separation of the lunar soils.

Oder, R. R.↗

Magnetic susceptibility of glassy carbon

Magnetic susceptibility of glassy carbon at room temperature with respect to magnetic field strength, heat treatment temperature, and high temperature tensile deformation

Fischbach, D. B.↗

Magnetic susceptibility variations in Loess sequences and their relationship to astronomical forcing

The long, well-exposed and often continuous sequences of loess found throughout the world are generally thought to provide an excellent opportunity for studying long-term, large-scale environmental change during the last few million years. In recent years, the most fruitful loess studies have been those involving the deposits of the loess in China. One of the most intriguing results of that work has been the discovery of an apparent correlation between variations in the magnetic susceptibility of the loess sequence and the oxygen isotope record of the deep sea. This correlation implies that magnetic susceptibility variations are being driven by astronomical parameters. However, the basic data have been interpreted in various ways by different authors, most of whom assumed that the magnetic minerals in the loess have not been affected by post-depositional processes. Using a chemical extraction procedure that allows us to separate the contribution of secondary pedogenic magnetic minerals from primary inherited magnetic minerals, we have found that the magnetic susceptibility of the Chinese paleosols is largely due to a pedogenic component which is present to a lesser degree in the loess. We have also found that the smaller inherited component of the magnetic susceptibility is about the same in the paleosols and the loess. These results demonstrate the need for additional study of the processes that create magnetic susceptibility variations in order to interpret properly the role of astronomical forcing in producing these variations.

Verosub, Kenneth L.↗

Dissociation of O(2-)2 defects into paramagnetic O(-) in wide band-gap insulators - A magnetic susceptibility study of magnesium oxide

The magnetic susceptibility of single-crystal MgO has been measured in the temperature range 300-1000 K, using a Faraday balance. The high-purity crystal (less than 100 ppm transition metals), grown from the melt in a H2O-containing atmosphere, was found to be paramagnetic due to the presence of defects on the O(2-) sublattice. The defects derive from OH(-) introduced into the MgO matrix by the dissolution of traces of H2O during crystal growth. The OH(-) converts into O(2-)2 and H2. Each O(2-)2 represents two coupled, spin-paired O(-) states. The observed strongly temperature-dependent paramagnetism can be described by three contributions that overlay the intrinsic diamagnetism of MgO and arise from the low level of transition-metal impurities, O(-) generated by 0(2-)2 dissociation, and O(-) states trapped by quenching from high temperatures from previous experiments.

Batllo, F.↗

High-temperature-superconducting magnetic susceptibility bolometer

An infrared detector called the magnetic susceptibility bolometer is introduced which is based on the tmperature dependence of the diamagnetic screening of a high-Tc superconductor film near Tc. Results are reported for the response of a prototype model to modulated blackbody radiation. Possible improvements are discussed as is the potential sensitivity of an improved device.

Brasunas, J.↗

Magnetization and magnetic susceptibilities of GdH3, HoH3, ErH3 and YbH3

The magnetic susceptibility of powdered samples of HoH3, ErH3, GdH3 and YbH3 have been measured in the temperature range from 4.2 to 1.2 K. Two broad, local maxima are observed in the variation of chi versus T for GdH3, with maxima in (delta chi delta T) versus T at 1.8 K and 3.3 K. The inverse susceptibilities for HoH3 and ErH3 both obey a Curies-Weiss law over a limited range (4.2 to 2.6K and 4.2 to 2 K respectively) with values for the Weiss constant of -4.25 K and -1.11 K, and effective moments of 8.6 and 7.7 Bohr magnetons respectively. The susceptibility of YbH3 is independent of temperature over the range investigated. High-field magnetization measurements yield extrapolated saturation moments of 7.0 + or - 0.25 Bohr magnetons/ion for GdH3, 6.1 + or - 0.2 Bohr magnetons/ion for HoH3 and 3.74 + or - 0.11 Bohr magnetons/ion for ErH3. In addition, ErH3 exhibits a van Vleck paramagnetism in the high field region.

Flood, D. J.↗

Magnetic susceptibility of Inconel alloys 718, 625, and 600 at cryogenic temperatures

After a hydrogen fuel bleed valve problem on the Discovery Space Shuttle was traced to the strong magnetization of Inconel 718 in the armature of the linear variable differential transformer near liquid hydrogen temperatures, the ac magnetic susceptibility of three samples of Inconel 718 of slightly different compositions, one sample of Inconel 625, and on sample of Inconel 600 were measured as a function of temperature. Inconel 718 alloys are found to exhibit a spin glass state below 16 K. Inconel 600 exhibits three different magnetic phases, the lowest-temperature state (below 6 K) being somewhat similar to that of Inconel 718. The magnetic states of the Inconel alloys and their magnetic susceptibilities appear to be strongly dependent on the exact composition of the alloy.

Goldberg, Ira B.↗

Lithology and chronology of ice-sheet fluctuations (magnetic susceptibility of cores from the western Ross Sea)

The goals of the marine geology part of WAIS include reconstructing the chronology and areal extent of ice-sheet fluctuations and understanding the climatic and oceanographic influences on ice-sheet history. As an initial step toward attaining these goals, down-core volume magnetic susceptibility (MS) logs of piston cores from three N-S transects in the western Ross Sea are compared. The core transects are within separate petrographic provinces based on analyses of till composition. The provinces are thought to reflect the previous locations of ice streams on the shelf during the last glaciation. Magnetic susceptibility is a function of magnetic mineral composition, sediment texture, and sediment density. It is applied in the western Ross Sea for two purposes: (1) to determine whether MS data differentiates the three transects (i.e., flow lines), and thus can be used to make paleodrainage reconstructions of the late Wisconsinan ice sheet; and (2) to determine whether the MS data can aid in distinguishing basal till diamictons from diamictons of glacial-marine origin and thus, aid paleoenvironmental interpretations. A comparison of the combined data of cores in each transect is presented.

Jennings, Anne E.↗

Exploiting the Temperature Dependence of Magnetic Susceptibility to Control Convection in Fundamental Studies of Solidification Phenomena

It is well known that convection is a dominant mass transport mechanism when materials are solidified on Earth's surface. This convection is caused by gradients in density (and therefore gravitational force) that are brought about by gradients in temperature, composition or both. Diffusion of solute is therefore dwarfed by convection and the study of fundamental parameters, such as dendrite tip shape and growth velocity in the absence of convection is nearly impossible. Significant experimental work has therefore been carried out in orbiting laboratories with the intent of minimizing convection by minimizing gravity. One of the best known experiments of this kind is the Isothermal Dendritic Growth Experiment (IDGE), supported by NASA. Naturally such experiments are costly and one objective of the present investigation is to develop an experimental method whereby convection can be- halted, in solidification and other experiments, on the surface. A second objective is to use the method to minimize convection resulting from the residual accelerations suffered by experiments in microgravity. The method to be used to minimize convection relies on the dependence of the magnetic susceptibility of a fluid on temperature or composition (whichever is driving convection). All materials experience a force when placed in a magnetic field gradient. The direction and magnitude of that force depend on the magnetic susceptibility of the material. Consequently the force will vary if the susceptibility varies with temperature or composition. With a magnetic field gradient in the right direction (typically upward) and of the right magnitude, this variation in the magnetic force can be made to exactly cancel the variation in the gravitational force. Expressed another way, normal buoyancy is exactly countered by a "magnetic buoyancy". To demonstrate the principle, a solution of MnC12 in water has been used. First the variation of the susceptibility of this paramagnetic solution with temperature and concentration was measured. Then a "cell", containing this solution and 50mm long by 15mm high by 155mm wide, was placed in a superconducting magnet at Marshall Space Flight Center. The magnetic field was measured at various positions within the bore of the magnet using a Hall effect probe. In this way, a position was found where the magnetic field gradient was predominantly upward; the magnitude of the gradient could then be adjusted by adjusting the current of the magnet. The ends of the cell consisted of machined copper blocks maintained at controlled temperatures by circulating water from constant temperature baths. The walls of the cell were of rectangular section glass tubing so that the cell contents could be seen. Velocities arising from thermal gradients within the cell were measured by particle image velocimetry (PIV). Particles used for this purpose were silver-coated hollow glass spheres of micrometers diameter and nearly the same density as the solution. A central vertical plane of the cell was illuminated by a laser beam passing through a cylindrical lens. Digital images of the particles were captured on a CCD camera and fed to a computer so that frame-to-frame movements of particles traveling with the fluid were captured. These images were employed to compute velocity maps using commercial PIV software. In a typical experiment the cold end of the cell was maintained at 10C and the warm end at 30 C. With no current in the magnet, i.e.- with natural -convection allowed to occur, the fluid was observed to circulate with an average speed of approximately 0.3 millimeters per second. It was visually apparent that this circulation was diminished as the current was increased. At currents of approximately 20A the flow was halted, to within the precision of the PIV measurements. At yet higher currents the convection was reversed with the hotter solution sinking and the cooler solution rising. At 40A this reversed convection had speeds averaging 0.43 millimeters per second. The measurements of susceptibility and density allow an estimate of the field gradient necessary to halt convection in the experiment. That estimate was 7.8T (squared) per meter and the convection was observed to halt in the magnet at a current giving 7.21T (squared) per meter from the magnetic field measurements. Calculations of the flow have been carried out using the computational fluid dynamics software FLUENT and show good agreement with the measurements.

Seybert, C. D.↗