Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Magnetic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A magnetically focused image tube employing an opaque photocathode

Image converter has been developed which uses opaque photocathode for improved efficiency. Device is easier to fabricate than previous semi-transparent photocathode converters and uses compounds from Groups 3-5 that are responsive to wave-lengths between ultraviolet (approximately 100 nm) and near infrared region (approximately 1000 nm).

Johnson, C. B.

Magnifying image intensifier

A magnetically focused image intensifier was improved to increase the usable range of magnification without degradation of image quality. The power requirements of the focusing coils are minimal. The arrangement of the focusing coils reverses the direction of the axial magnetic field distribution between the planes of the photocathode and the phosphor screen.

Vine, J.

Electron-optic limitations on image resolution

Various approaches are considered to the solution of the electron-optical problem of designing an image tube configuration. Emphasis is placed on the method of computer design, and an illustration is given in which the technique is used in the design of an 80-mm image tube with a zoom capability of 3:1. The solutions are discussed to such problems as image distortion, magnification, and electron bundles striking the zoom electrode. Three types of an electron-optical configuration are examined for the electron-optic limitations to resolution: (1) the proximity image tube, (2) the magnetic-type image tube having uniform electric and magnetic fields, and (3) the electrostatic-type image tube such as the 80-mm zoom tube.

Engstrom, R. W.

Ruggedized electronographic tube development

Because of their glass components and lack of far ultraviolet sensitivity, currently available Spectracons are not suited for rocket launch. Technology developed for second generation image tubes and for magnetically focused image tubes can be applied to improve the optical and mechanical properties of these magnetically focused electronographic tubes whose 40 kilovolt signal electrons exit a 4-micrometer thick mica window and penetrate a photographic recording emulsion.

Nevin, S.

Self-scanned Digicon - A digital image tube for astronomical spectroscopy

We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.

Tull, R. G.

Intagliated phosphor screen image tube project

The production and evaluation of a magnetic focus image tube for astronomical photography that has an intagliated phosphor screen is described. The modulation transfer function of such a tube was measured by electronic means and by film tests, and the results compared with tubes of more conventional construction. The physical properties of the image tube and film combination, the analytical model of the optical interface, and the salient features of the intagliated screen tube are described. The results of electronic MTF tests of the intagliated image tube and of the densitometry of the tube and film test samples are presented. It is concluded that the intagliated screen is a help, but that the thickness of the photographic film is also important.

Hertzel, R. J.

Recent progress in photoelectron image detection with CCDs

Intensified CCDs (ICCDs) were built and operated. These ICCDs were electrostatically and magnetically-focussed image tubes which use CCDs as anodes. The ICCDs detected single photoelectrons, and have electron gain very near that which was predicted. The first single-pixel pulse-height distributions were presented, and the leakage current was shown to increase as a function of photoelectron irradiation. The advantages and disadvantages of front- and rear-illuminated designs were discussed in light of differing applications requirements.

Choisser, J. P.

Determination of plasma parameters from soft X-ray images for coronal holes /open magnetic field configurations/ and coronal large-scale structures /extended closed-field configurations/

In connection with high-quality solar soft X-ray images the 'quiet' features of the inner corona have been separated into two sharply different components, including the strongly reduced emission areas or coronal holes (CH) and the extended regions of looplike emission features or large-scale structures (LSS). Particular central meridian passage observations of the prominent CH1 on August 21, 1973, are selected for a quantitative study. Histogram photographic density distributions for full-disk images at other central meridian passages of CH 1 are also presented, and the techniques of converting low photographic density data to deposited energy are discussed, with particular emphasis on the problems associated with the CH data.

Maxson, C. W.

An electron-lens for opaque photocathodes.

It is possible to employ opaque photocathodes in image tubes having a special electromagnetic lens without the use of special internal image-forming optical lenses or mirrors. The special electron lens, having flat object and image planes, is found to provide excellent quality electron-optical image transfer. Stray light reflection inside the tube is expected to be less serious in this electron lens than in a conventional magnetically focused image tube lens due to the offset image plane, and due to the increased absorption of photons in opaque photocathode applications.

Johnson, C. B.

Solar flares

The present paper deals with explosions in a magnetized solar plasma, known as flares, whose effects are seen throughout the electromagnetic spectrum, from gamma-rays through the visible and to the radio band. The diverse phenomena associated with flares are discussed, along with the physical mechanisms that have been advanced to explain them. The impact of solar flare research on the development of plasma physics and magnetohydrodynamics is noted. The rapid development of solar flare research during the past 20 years, owing to the availability of high-resolution images, detailed magnetic field measurements, and improved spectral data, is illustrated.

Rust, D. M.

Synthesis of regional crust and upper-mantle structure from seismic and gravity data

Analyses of regional gravity and magnetic patterns, LANDSAT images and geological information revealed two major lineaments crossing western Pennsylvania and parts of surrounding states. These lineaments are inferred to be expressions of fracture zones which penetrare deeply into the crust and possibly the upper mantle. The extensions of the Tyron-Mt. Union and the Pittsburgh-Washington lineaments bound a distinct crustal block (Lake Erie-Maryland block) over 100 km wide and probably more than 600 km in length. Evidence exists for the lateral displacement of this block at least 60 km northwestward during late Precambrian to Lower Ordovician time. Subsequent movements have been mainly vertical with respect to neighboring blocks. A possible crustal block that passes through eastern Kentucky, proposed by a TVA study on tectonics in the southern Appalachians, was also investigated. Finally, the use of regional gravity and magnetic data in identifying major crustal structures beneath western Pennsylvania is discussed.

Alexander, S. S.

The forecasting center of Meudon, France

Main features of solar activity are described in relation to solar and geophysical forecasting. Spectroheliograms, radio and X-ray data, white light coronal observations, particles data, photospheric images, and photospheric magnetic fields are among the types of data used to identify the active centers and flares of the Sun. Forecasting and identification of geomagnetic activity is also discussed. The forecasting technique is described along with the types of users.

Simon, P.

Manufacturing process applications team (MATeam)

The objectives and activities of an aerospace technology transfer group are outlined and programs in various stages of progress are described including the orbital tube flaring device, infrared proximity sensor for robot positioning, laser stripping magnet wire, infrared imaging as welding process tracking system, carbide coating of cutting tools, nondestructive fracture toughness testing of titanium welds, portable solar system for agricultural applications, and an anerobic methane gas generator.

Bangs, E. R.

X-ray topographic observations of magnetic domains in Czochralski-grown nickel single crystals in anomalous transmission geometry

The anomalous transmission effect has been observed in nickel single crystals grown by the Czochralski technique. Sample crystals prepared for X-ray topography are 1.5 to 2.5 cm in diameter and thicker than 0.4 mm; the product of the ordinary linear absorption coefficient and thickness ranges from 17 to 45 for Cu K-alpha radiation. Topographs taken with an asymmetric-crystal-topographic (ACT) camera have revealed extremely straight line images and rectangular arrangements of short line-segment images, along with the images of crystal imperfections. The line images change their arrangement upon application of magnetic fields. These images are attributed to magnetic domains in the interior of crystals. The formation of domain walls near the crystal surface is also observed and distinguished clearly from magnetic domains in the bulk with the use of the ACT camera.

Kuriyama, M.