Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Second-order magnetic responses in quantum magnets: Magnetization under ac magnetic fields

Here we investigate second-order magnetic responses of quantum magnets against ac magnetic fields. We focus on the case where the z component of the spin is conserved in the unperturbed Hamiltonian and the driving field is applied in the xy plane. We find that linearly polarized driving fields induce a second-harmonic response, while circularly polarized fields generate only a zero-frequency response, leading to a magnetization with a direction determined by the helicity. Employing an unbiased numerical method, we demonstrate the nonlinear magnetic effect driven by the circularly polarized field in the XXZ model and show that the magnitude of the magnetization can be predicted by the dynamical spin structure factor in the linear response regime.

36 MATERIALS SCIENCE↗

Quantum Imaging of Magnetic Phase Transitions and Spin Fluctuations in Intrinsic Magnetic Topological Nanoflakes

Topological materials featuring exotic band structures, unconventional current flow patterns, and emergent organizing principles offer attractive platforms for the development of next-generation transformative quantum electronic technologies. The family of MnBi 2 T e4 (Bi 2 Te 3 )n materials is naturally relevant in this context due to their nontrivial band topology, tunable magnetism, and recently discovered extraordinary quantum transport behaviors. Despite numerous pioneering studies, to date, the local magnetic properties of MnBi 2 Te 4 (Bi 2 Te 3 )n remain an open question, hindering a comprehensive understanding of their fundamental material properties. Exploiting nitrogen-vacancy (NV) centers in diamond, we report nanoscale quantum imaging of magnetic phase transitions and spin fluctuations in exfoliated MnBi 2 Te 4 (Bi 2 Te 3 )n flakes, revealing the underlying spin transport physics and magnetic domains at the nanoscale. Furthermore, our results highlight the unique advantage of NV centers in exploring the magnetic properties of emergent quantum materials, opening new opportunities for investigating the interplay between topology and magnetism.

Antiferromagnetic materials↗

Synthesis, Magnetic Properties, and Electronic Structure of Magnetic Topological Insulator MnBi 2 Se 4

The intrinsic magnetic topological insulators MnBi 2 Te 4 and MnBi 2 Se 4 support novel topological states related to symmetry breaking by magnetic order. Unlike MnBi 2 Te 4 , the study of MnBi 2 Se 4 has been inhibited by the lack of bulk crystals, as the van der Waals (vdW) crystal is not the thermodynamic equilibrium phase. In this study, we report the layer-by-layer synthesis of vdW MnBi 2 Se 4 crystals using nonequilibrium molecular beam epitaxy. Atomic-resolution scanning transmission electron microscopy and scanning tunneling microscopy identify a well-ordered vdW crystal with septuple-layer base units. The magnetic properties agree with the predicted layered antiferromagnetic ordering but disagree with its predicted out-of-plane orientation. Instead, our samples exhibit an easy-plane anisotropy, which is explained by including dipole–dipole interactions. Angle-resolved photoemission spectroscopy reveals the gapless Dirac-like surface state, which demonstrates that MnBi 2 Se 4 is a topological insulator above the magnetic-ordering temperature. These studies show that MnBi 2 Se 4 is a promising candidate for exploring rich topological phases of layered antiferromagnetic topological insulators.

36 MATERIALS SCIENCE↗

Advanced Permanent Magnet Generator Topologies Using Multimaterial Shape Optimization and 3D Printing: Preprint

A vast majority of utility-scale wind turbine generators in the United States are dependent on foreign- sourced rare-earth permanent magnets that are vulnerable to supply chain uncertainties. Many small wind original equipment manufacturers are motivated to pursue continuous improvements to the generator design to lower the material and production costs and improve performance by lowering cogging torque and increasing the efficiency. Traditional design and manufacturing offer limited opportunities. In this work, we demonstrate advanced design approaches for a 15-kW baseline wind turbine generator by making use of recent progress in three-dimensional (3D) printing of polymer- bonded magnets and, electrical and structural steel. We explore three methods of magnet parametrization using Bezier curves resulting in symmetric, asymmetric and multimaterial magnet designs. We employ a multiphysics approach combining parametric computer-aided design modeling, finite- element analysis and targeted sampling to identify novel designs with more opportunities for reducing rare-earth material, improving efficiency and minimizing cogging torque. The results show that asymmetric-pole design and multimaterial-pole designs offer a greater opportunity to minimize rare-earth magnet materials by up to 35% with similar performance as the baseline generator, suggesting newer opportunities with design freedom beyond traditional limits of symmetry and as allowed by 3D printing.

Bezier curves↗

An Assessment of Additively Manufactured Bonded Permanent Magnets for a Distributed Wind Generator

In this paper, we examine and compare the performance of a generator design optimized using additively manufactured NdFeB-SmFeN in nylon-polymer-bonded permanent magnets (PMs) against a generator design with conventional NdFeB sintered PMs. To realize this, a commercially available 15-kW wind generator's rotor is re-optimized using both additively manufactured and sintered NdFeB magnets using simple geometric parameterization that allowed for two specific magnet shapes, namely, arc-shaped and crown-shaped designs. Results showed that for a similar generator performance, the designs with additively manufactured bonded PMs are more cost-competitive in terms of the estimated PM material cost and also have negligible eddy current magnet losses.

additive manufacturing↗

Direct visualization of magnetic domains and moiré magnetism in twisted 2D magnets

Moiré superlattices of twisted nonmagnetic two-dimensional (2D) materials are highly controllable platforms for the engineering of exotic correlated and topological states. In this work, we report emerging magnetic textures in small-angle twisted 2D magnet chromium triiodide (CrI 3 ). Using single-spin quantum magnetometry, we directly visualized nanoscale magnetic domains and periodic patterns, a signature of moiré magnetism, and measured domain size and magnetization. In twisted bilayer CrI 3 , we observed the coexistence of antiferromagnetic (AFM) and ferromagnetic (FM) domains with disorder-like spatial patterns. In twisted double-trilayer CrI 3 , AFM and FM domains with periodic patterns appear, which is in good agreement with the calculated spatial magnetic structures that arise from the local stacking-dependent interlayer exchange interactions in CrI 3 moiré superlattices. Our results highlight magnetic moiré superlattices as a platform for exploring nanomagnetism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Comparison of Surface Inset Permanent Magnet Machine and Surface Permanent Magnet Machine without Heavy Rare Earth Magnets for Traction Applications

This paper presents two machine designs: a surface inset permanent magnet (SIPM) machine and a surface permanent magnet (SPM) machine, both without heavy rare-earth magnets, that achieve 50 kW/L active power density and a constant-power speed ratio of 3 for EV traction applications. Compared to surface PM machines, SIPM machines do not require a special containment sleeve to hold the magnets in place at high speeds, provided that the rotor laminations are carefully designed together with the magnet mounting configuration to ensure the rotor’s structural integrity. Comparisons between the SPM and SIPM machines sharing the same stator, same current level, and same power speed envelope are presented. Both deliver very similar performance characteristics, but the SIPM machine’s simpler magnet containment configuration may give it an advantage in terms of reduced material and manufacturing costs.

42 ENGINEERING↗

Magnetic force microscopy revealing long-range room temperature stable molecule bridge-induced magnetic ordering on magnetic tunnel junction (MTJ) pillars

Magnetic tunnel junctions (MTJs) can integrate novel single molecular device elements to overcome long-standing fabrication challenges, thus unlocking their novel potential. This study employs magnetic force microscopy (MFM) to demonstrate that organometallic molecules, when placed between two ferromagnetic electrodes along cross-junction shaped MTJ edges, dramatically altered the magnetic properties of the electrodes, affecting areas several hundred microns in size around the molecular junction vicinity at room temperature. These findings are supported by magnetic resonance and magnetometer studies on ∼7000 MTJ pillars. MFM on the pillar sample showed an almost complete disappearance of the magnetic contrast. The spatial magnetic image suggests that molecular channels significantly impacted the spin density of states in the ferromagnetic electrodes. This advancement in MTJ-based molecular devices paves the way for a new generation of commercially viable logic and memory devices controlled by molecular quantum states at near-room temperatures.

Tyagi, Pawan (ORCID:0000000275411344)↗

Using an Analytic-Based Magnetic Charge Fourier Series Model to Study a Magnetic Lead Screw when Operating as a Magnetic Spring

A magnetic charge field analysis approach is presented that models an array of magnets by using a magnetic vector Fourier series representation. Using a Fourier series function enables the magnets' relative permeability to be accounted for and also reduces the computational burden. The accuracy of the presented modelling approach is validated by studying the fields and forces created by a magnetic lead screw when acting as a magnetic spring

Kouhshahi, Mojtaba Bahrami↗

Development of combined function dipole-quadrupole PMQs magnets for NSLS-II upgrade

This paper focuses on the R&D performed for the development of permanent magnets-based dipoles-quadrupoles combined function magnets (PMQs) for the future NSLSII upgrade “complex bend” lattice (CB). This new lattice uses PMQs that provide both bending (dipole) and strong focusing (quadrupole) magnetic field on the electron beam. The permanent magnet (PM) technology is suitable for the high magnetic field strengths (0.5 T, 130 T/m) required for such combine function magnets. PM technology leads to a compact magnet design that is essential in realizing the complex bend lattice concept, as well as a passive magnet solution which does not require electrical power supply reducing power consumption by ~ 80% (from 1.7 MW to 0.3 MW for NSLS-II). Two PMQs magnets designs are under consideration: A hybrid design that use both PM and soft iron poles, and Halbach type that is a pure PM design. Both PMQs designs present challenges in achieving the specified magnetic field quality due to their higher sensitivity to errors (mechanical tolerances and PM properties). This paper presents cost-effective designs and prototypes results for hybrid and Halbach PMQs, addressing various technical challenges while meeting the field requirements of the complex bend lattice for the NSLS-II upgrade.

N'gotta, Patrick [Brookhaven]↗

Field quality of the 4.5 m-long MQXFA pre-series magnets for the HL-LHC Upgrade as observed during magnet assembly

We report that the U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb 3 Sn quadrupole magnets for the HL-LHC upgrade at CERN. Five pre-series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements on the coil-pack sub-assembly and magnets after loading to track the field quality for two purposes. First, it serves as a quality assurance tool to check if the magnetic field quality is on track to meet the acceptance criteria. Magnetic measurements are used to understand if magnetic shims are needed to compensate low-order field errors and to meet the field quality targets. Second, the measurements during the assembly stage can also help understand the field quality, especially the geometric field errors, for Nb 3 Sn accelerator magnets. Here we summarize the measurement results of the pre-series MQXFA magnets, including the magnetic axis and twist angle. The results will provide useful feedback for the series production of Nb 3 Sn magnets and on the optimization of field quality of accelerator magnets based on the wind-and-react Nb 3 Sn technology.

43 PARTICLE ACCELERATORS↗

Experimental determination of the magnetic anisotropy in five-coordinated Co( II ) field-induced single molecule magnets

Magnetic anisotropy of the central metal atom is a crucial property of single molecule magnets (SMMs). Small structural changes can alter the magnetic properties, and accurate experimental methods to investigate magnetic anisotropy are therefore critical. Here, we investigate two five-coordinated Co( II ) SMMs, [CoCl 2 Cltpy] (1) and [CoBr 2 Cltpy] (2) (Cltpy = 4′-chloro-2,2′:6′,2′′-terpyridine), through multiple techniques. Ab initio theoretical calculations performed on the two compounds show that both possess axial magnetic anisotropy with the magnetic easy axis pointing towards one of the terminal halogen atoms. Theoretical calculations on SMMs are typically done on isolated molecular species, and to validate this approximation the magnetic anisotropy was further studied through experimental techniques. EPR measurements confirm an axial anisotropy of 1, and magnetic measurements provide experimental Zero-Field Splitting (ZFS) parameters, showing that the values from theoretical calculations are slightly overestimated. The X-ray electron density determined from 20 K single-crystal synchrotron X-ray diffraction data provides estimated d-orbital populations also suggesting axial magnetic anisotropy in both systems, and furthermore suggesting a more pronounced axiality in 1 compared to 2. This is in good agreement with the results obtained from both magnetic measurements and theoretical calculations. The magnetic anisotropy of 1 is quantified experimentally through polarized powder neutron diffraction via the site susceptibility method, confirming an axial magnetic anisotropy of the compound. A slight deviation in the easy axis direction is observed between experimental and theoretical results. This, together with the overestimation of the ZFS parameters from theoretical calculations, shows that experimental investigation of the magnetic anisotropy of SMMs is of high relevance. Magnetic anisotropy of the central metal atom is a crucial property of single molecule magnets (SMMs).

Slavensky, Hannah H. [Aarhus Univ. (Denmark)] (ORC↗

Sawtooth lattice multiferroic BeCr 2 O 4 : Noncollinear magnetic structure and multiple magnetic transitions

Noncollinear magnetic structures and multiple magnetic phase transitions in a sawtooth lattice antiferromagnet consisting of Cr 3+ are experimentally identified in this work, thereby proposing the scenario of magnetism-driven ferroelectricity in a sawtooth lattice. The title compound, BeCr 2 O 4 , displays three magnetic phase transitions at low temperatures—at T N1 ≈ 7.5 K, at T N2 ≈ 25 K, and at T N3 ≈ 26 K—revealed through magnetic susceptibility, specific heat, and neutron diffraction in this work. These magnetic phase transitions are found to be influenced by externally applied magnetic fields. Isothermal magnetization curves at low temperatures below the magnetic transitions indicate the antiferromagnetic nature of BeCr 2 O 4 with two spin-flop-like transitions occurring at H c1 ≈ 29 kOe and H c2 ≈ 47 kOe. Our high-resolution x-ray and neutron diffraction studies, performed on single crystal and powder samples, unambiguously determined the crystal structure as orthorhombic Pbnm. By performing the magnetic superspace group analysis of the neutron diffraction data at low temperatures, the magnetic structure in the temperature range T N3,N2 < T < T N1 is determined to be the polar magnetic space group P21nm. 1' (00g) 0s0s with a cycloidal magnetic propagation vector k 1 = (0, 0, 0.090 (1)) . The magnetic structure in the newly identified phase below T N1 is determined as P21/b.1' [b] (00 g) 00s with the magnetic propagation vector k 2 = (0, 0, 0.908 (1)). Finally, the cycloidal spin structure determined in our work is usually associated with electric polarization, thereby making BeCr 2 O 4 a promising multiferroic belonging to the sparsely populated family of sawtooth lattice antiferromagnets.

36 MATERIALS SCIENCE↗

Predicting magnetic properties of single-molecule magnets from self-interaction-free density-functional theory (Final Report)

In this project we investigated electronic structure of an intermediate-sized copper-based molecule and magnetic and hyperfine properties of several small non-magnetic and magnetic molecules including transition-metal elements by applying self-interaction corrections to density functional theory (DFT). In a sufficient number of cases, DFT-calculated electronic structure and magnetic properties of single-molecule magnets qualitatively differ from corresponding experimental data. This is partly due to self-interacting electrons within the DFT formalism. Recently, an efficient method to correct the self-interactions was proposed, i.e., Fermi-Lowdin prbital (FLO) based self-interaction corrected (SIC) methodology, within DFT. Henceforth, this method is referred to as FLO-SIC method which exists in FLOSIC code. We used this FLO-SIC method for our studies of electronic structure and magnetic and hyperfine properties of small magnetic molecules and non-magnetic molecules. Our study will provide insight into predictions of magnetic properties of single-molecule magnets where self-interaction corrections play a critical role. There are two components of this project. In the first work, we studied the electronic structure of a planar mononuclear Cu-based molecule in two oxidation states, using DFT with the FLO-SIC method. We chose this system because it is small enough and it includes a transition metal element. We found that the standard FLO-SIC method takes too much compute time even for the small transition-metal molecule and so we slightly modified the method in order to expedite the process. In the dianionic state, we found that the FLO-SIC spin density agrees quantitatively with accurate quantum chemistry methods, while DFT spin density without self-interaction corrections are severely deviated from the quantum chemistry methods. We also showed that the energy gap between the highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO) of the dianionic state is larger than that of the monoanionic state. This result is consistent with experimental data. In the second work, we investigated how the interaction between the electron spin and nuclear spin is affected by electron self-interactions within small non-magnetic and magnetic molecules. Such an interaction is called hyperfine interaction. For molecules without significant orbital angular momentum, the hyperfine interaction consists of Fermi contact and dipolar interaction terms. Since the Fermi contact term depends on electron spin density at the nuclear site, it would be highly affected by self-interaction corrections. Therefore, we calculated the hyperfine interaction for the small molecules using DFT with the slightly modified expedited FLO-SIC method which was obtained in the first work, and compared the results to experimental data and DFT calculations without self-interaction corrections. We found significant improvement of the Fermi contact term computed using the FLO-SIC method for small magnetic molecules. Overall, the first and second work provided positive outlook of application of the FLO-SIC method to magnetic molecules and systems including transition-metal elements.

36 MATERIALS SCIENCE↗

Circumventing data imbalance in magnetic ground state data for magnetic moment predictions

Abstract Magnetic materials play a crucial role in the transition to more sustainable forms of energy and electric vehicles. There is an anticipated shortage in magnetic materials in the future, and as a result there is an urgent need to discover and design new magnetic materials. Computational magnetic material design using density functional theory is daunting because of the challenge in identifying magnetic ground states from a combinatorially large set of possibilities. Machine learning offers a path forward by enabling efficient surrogate models that can more readily enumerate these states, but there is a dearth of training data available, and what is available tends to be imbalanced with too much non-magnetic data. In this work we show that the discrete and previously tackled data imbalance that exists at the level of the magnetic ordering leads to an imbalanced continuous distribution with many zeros when the data is unraveled at the atomic magnetic moment level, which subsequently leads to models with low accuracy for magnetic properties. We mitigate this by using a two-part model framework. Our scheme is able to classify atoms into magnetic and non-magnetic with an F1 score and Matthew’s correlation coefficient (MCC) of ~91% and then to provide an implicit embedding representation that maps directly onto the magnitude of the magnetic moment with a mean absolute error of 0.1 μ B . Beyond screening for new magnetic materials, we demonstrate an additional practical use case of our scheme: the provision of good initial guesses for magnetic moments in first-principles electronic relaxations. Such initialization is shown to lead to faster convergence to configurations that lie closer to the ground state.

Computer Science↗

Mechanically Robust High Magnetic Performance Sm-Co Sintered Magnets (Final Report)

Samarium-cobalt based permanent magnets (SmCo 5 and Sm 2 Co 17 ) have excellent magnetic properties, good corrosion resistance, and long-term thermal stability. Sm-Co sintered magnets have been widely used in electric machines, telecommunication, biomedical devices, and magnetic sensors. They are the most preferred magnets for high-temperature applications (200 - 550 °C). However, Sm-Co sintered magnets are brittle. They cannot be used for applications subjected to high stress, vibration, or mechanical shock. Sm-Co sintered magnets are prone to chipping, and fracture in the course of block magnet manufacturing, part machining, assembly, and operation. The brittleness leads to a magnet production loss of up to 20-30% in volume and imposes limitations on part size and shape. Developing mechanically robust high-performance Sm-Co sintered magnets is of great scientific and technical significance. This project is in response to the current market need for mechanically robust high magnetic performance Sm-Co sintered magnets and their novel manufacturing processes. The project will focus on scaling-up, validation, and technology maturation study of the mechanically tough high magnetic performance Sm-Co magnets developed by Ames Laboratory at a lab-scale with the collaboration of the industry partner Electron Energy Corporation (EEC).

36 MATERIALS SCIENCE↗

Magnetic, Mechanical and Thermal Modeling of Superconducting, Whole-Body, Actively Shielded, 3 T MRI Magnets Wound Using MgB 2 Strands for Liquid Cryogen Free Operation

Here we present magnetic, mechanical and thermal modeling results for a 3 Tesla actively shielded whole body MRI (Magnetic Resonance Imaging) magnet consisting of coils with a square cross section of their windings. The magnet design was a segmented coil type optimized to minimize conductor length while hitting the standard field quality and DSV (Diameter of Spherical Volume) specifications as well as a standard, compact size 3 T system. It had an overall magnet length and conductor length which can lead to conduction cooled designs comparable to NbTi helium bath cooled 3 T MRI magnets. The design had a magnetic field homogeneity better than 10 ppm (part-per-million) within a DSV (Diameter of Spherical Volume) of 48 cm and the total magnet winding length of 1.37 m. A new class of MgB 2 strand especially designed for MRI applications was considered as a possible candidate for winding such magnets. This work represents the first magnetic, mechanical and thermal design for a whole-body 3 T MgB 2 short (1.37 m length) MRI magnet based on the performance parameters of existing MgB 2 wire. 3 Tesla MRI magnet can operate at 20 K at 67% of its critical current.

43 PARTICLE ACCELERATORS↗