The upgrade of endcap CMS muon system

The configuration and composition of the CMS muon system are presented. The paper is focused on cathode strip chambers (CSC) used as the endcap muon system detectors. The goals and objectives of the endcap muon system upgrade are formulated. The main results of works accomplished for the ME1/1 CSCs upgrade and the new ME4/2 muon station construction during the LHC Long Shutdown-1 (2013–2014) are presented. The improved performances of the endcap muon system are shown using experimental data obtained after the upgrade (Run2 data).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronics integration for the GE2/1 and ME0 GEM detector systems for the CMS phase-2 muon system upgrade

Abstract The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon spectrometer to cope with the increased muon flux in the forward region. The GE2/1 triple-gas electron multiplier detector, which has recently entered the mass production phase, and the ME0 triple-GEM detector system, which is in the late prototyping phase, are undergoing electronics integration. These proceedings briefly discuss the frontend electronics for the GE2/1 and ME0 detector systems, the electronics integration testing process, and the future plans for the frontend electronics of these two detector systems by the CMS GEM collaboration.

Instruments & Instrumentation↗

Time and position resolution of the scintillator strips for a muon system at future colliders

In this study, prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for vector-like leptons with long-lived particle decays in the CMS muon system in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A first search is presented for vector-like leptons (VLLs) exclusively decaying into a light long-lived pseudoscalar boson and a standard model τ lepton. The pseudoscalar boson is assumed to have a mass below the τ + τ − threshold, so that it decays exclusively into two photons. It is identified using the CMS muon system. The analysis is carried out using a data set of proton-proton collisions at a center-of-mass energy of 13 TeV collected by the CMS experiment in 2016–2018, corresponding to an integrated luminosity of 138 fb −1 . Selected events contain at least one pseudoscalar boson decaying electromagnetically in the muon system and at least one hadronically decaying τ lepton. No significant excess of data events is observed compared to the background expectation. Upper limits are set at 95% confidence level on the vector-like lepton production cross section as a function of the VLL mass and the pseudoscalar boson mean proper decay length. The observed and expected exclusion ranges of the VLL mass extend up to 700 and 670 GeV, respectively, depending on the pseudoscalar boson lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for vector-like leptons with long-lived particle decays in the CMS muon system in proton-proton collisions at $$\sqrt{\text{s}}$$ = 13 TeV

Abstract A first search is presented for vector-like leptons (VLLs) exclusively decaying into a light long-lived pseudoscalar boson and a standard model τ lepton. The pseudoscalar boson is assumed to have a mass below the τ + τ − threshold, so that it decays exclusively into two photons. It is identified using the CMS muon system. The analysis is carried out using a data set of proton-proton collisions at a center-of-mass energy of 13 TeV collected by the CMS experiment in 2016–2018, corresponding to an integrated luminosity of 138 fb −1. Selected events contain at least one pseudoscalar boson decaying electromagnetically in the muon system and at least one hadronically decaying τ lepton. No significant excess of data events is observed compared to the background expectation. Upper limits are set at 95% confidence level on the vector-like lepton production cross section as a function of the VLL mass and the pseudoscalar boson mean proper decay length. The observed and expected exclusion ranges of the VLL mass extend up to 700 and 670 GeV, respectively, depending on the pseudoscalar boson lifetime.

Chekhovsky, V. [Yerevan Physics Institute]↗

Tests of Scintillator+WLS Strips for Muon System at Future Colliders

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~ 7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GEM detectors for the CMS endcap muon system: status of three new detector stations

The High-Luminosity LHC (HL-LHC, or Phase-2 LHC) will deliver proton-proton collisions at 5–7.5 times the nominal LHC luminosity, with an expected number of 140–200 pp-interactions per bunch crossing (Pile-up or PU). To maintain the performance of muon triggering and reconstruction under high background, the forward part of the Muon Spectrometer of the CMS experiment will be upgraded with Gas Electron Multipliers (GEM) and improved Resistive Plate Chambers (iRPC) detectors. A first GEM station (GE1/1) was installed during Long Shutdown 2 (LS2, 2019–2021), a 2 nd station (GE2/1) of Triple-GEM detectors will be installed in winter 2023–24 and 2024–25, while a new 6-layer station (ME0) will be installed in the third Long Shutdown (LS3, 2026–2028). GE11 is considered an early Phase-2 upgrade as it will reduce the p T threshold by combining GEM and Cathode Strip Chamber (CSC) hits in the forward muon system at twice the LHC design luminosity ($\mathcal{L}$ = 2 · 10 34 cm -2 s -1 , 50 PU). After a successful start of Run-3 in 2022, with almost 40 fb -1 collected, the commissioning of the GE1/1 detector is nearly complete. Most chambers are operated stably with an efficiency in excess of 95%, next being the demonstration of the combined CSC-GEM trigger in 2023. The lessons learnt with the first large-area GEM station have lead to improvements in detector and electronics design for the Phase 2 detectors GE2/1 and ME0. This proceeding will discuss the progress made since last MPGD Conference (MPGD 2019), discussing the commissioning and early performance of GE1/1; the design improvements and start of construction of GE2/1; and the R&D currently ongoing for ME0.

47 OTHER INSTRUMENTATION↗

Muon flux measurements at the davis campus of the sanford underground research facility with the majorana demonstrator veto system

We report the first measurement of the muon flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 foot level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. Both results are in agreement within statistical accuracy. The measured flux is (4.08+-0.19) x 10 -9 muons/cm/2. We compare our results with previous calculations.

Abgrall, N.↗

The Muon System of the Daya Bay Reactor Antineutrino Experiment

The Daya Bay experiment consists of functionally identical antineutrino detectors immersed in pools of ultrapure water in three well-separated underground experimental halls near two nuclear reactor complexes. These pools serve both as shields against natural, low-energy radiation, and as water Cherenkov detectors that efficiently detect cosmic muons using arrays of photomultiplier tubes. Each pool is covered by a plane of resistive plate chambers as an additional means of detecting muons. Design, construction, operation, and performance of these muon detectors are described. (auth)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon detectors, systems and methods

A muon detector system capable of determining muon direction and flight trajectory or path is disclosed. The muon detector system includes scintillators for determining muon direction, and an array of muon detectors arranged in orthogonal layers for determining flight trajectory. The system can be used for tomographic and telescopic mode imaging, and may be used for imaging concealed and/or subterranean objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon detectors, systems and methods

A muon detector system capable of determining muon direction and flight trajectory or path is disclosed. The muon detector system includes scintillators for determining muon direction, and an array of muon detectors arranged in orthogonal layers for determining flight trajectory. The system can be used for tomographic and telescopic mode imaging, and may be used for imaging concealed and/or subterranean objects.

Bonal, Nedra D.↗

Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at $\sqrt{s}=$ 13 TeV

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013–2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy √s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T-1072: Beam test for muon strips

Beam test for muon strips is an experiment to measure the efficiency, time resolution and longitudinal position resolution of scintillator strips for a muon system at future colliders. The muon system at future colliders is envisioned as several layers of position-sensitive detectors embedded in the iron flux-return yoke of the solenoidal magnet. The role of the muon system is primarily the identification of muons and track matching to the central tracker, besides serving as the tail catcher for the hadronic showers that penetrate beyond the hadron calorimetry. Previous tests performed at Fermilab with cosmic muons have shown that scintillators with wavelength-shifting (WLS) fibers and a SiPM readout offer promising performance (NIM A 823, 2016, pp.120-125). The purpose of the present beam tests is to determine the performance parameters with better accuracy. The measurement setup is schematically presented in Fig. 1. The length of the tested strips will vary between 1 m and 2 m. The scintillator strip to be tested will be placed horizontally perpendicular to the beam on a platform in the area behind the beam dump of MT6.2. Two fast scintillators S1 and S2 with vacuum PMT readout will be placed in front and after the tested strip in the beam. The distance between S1 and S2 is 1 m. One fast scintillator strip S3 will be placed in beam immediately in front of the tested strip, perpendicular to the tested strip. A rack with a CAMAC crate and two NIM crates will be used for the data acquisition. The data collection will be performed and monitored from a PC with USB connection to the CAMAC Crate controller.

43 PARTICLE ACCELERATORS↗

Performance of the CMS muon trigger system in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 $\times$ 10$^{34}$cm$^{-2}$s$^{-1}$ while delivering proton-proton collisions at $\sqrt{s} =$ 13 TeV. The challenge for the trigger system of the CMS experiment is to reduce the registered event rate from about 40 MHz to about 1 kHz. Significant improvements important for the success of the CMS physics program have been made to the muon trigger system via improved muon reconstruction and identification algorithms since the end of Run 1 and throughout the Run 2 data-taking period. The new algorithms maintain the acceptance of the muon triggers at the same or even lower rate throughout the data-taking period despite the increasing number of additional proton-proton interactions in each LHC bunch crossing. In this paper, the algorithms used in 2015 and 2016 and their improvements throughout 2017 and 2018 are described. Measurements of the CMS muon trigger performance for this data-taking period are presented, including efficiencies, transverse momentum resolution, trigger rates, and the purity of the selected muon sample. This paper focuses on the single- and double-muon triggers with the lowest sustainable transverse momentum thresholds used by CMS. The efficiency is measured in a transverse momentum range from 8 to several hundred GeV.

Trigger detectors↗

Development of high-resolution muon tracking systems based on micro-pattern detectors

A muon tracking system consisting of four 9 cm x 10 cm sized bulk Micromegas detectors with 128 {mu}m amplification-gap and two 10 cm x 10 cm triple GEM detectors is foreseen for high-precision tracking of 140 GeV muons at the H8 beamline at CERN with a rate of up to 10 kHz and an overall resolution below 40 {mu}m. Larger detectors with an active area of 0.5 m{sup 2} and more are under development for detector studies in high neutron or gamma ray background environments at the Gamma Irradiation Facility at CERN and the Munich tandem accelerator. Signal studies of both detector types have been performed by recording cosmic muon and 5.9 keV X-ray signals with a single charge-sensitive preamplifier using several gas-mixtures of Ar:CO{sub 2}. The signals were digitized using 1 GHz VME based flashADCs with 2520 sampling points. The analysis of the complete signal-cycles allows for the determination of rise times, pulse heights, timing fluctuations and discrimination of background, resulting in a FWHM energy resolution of about 20% and detection efficiencies of 99% and more. Models for signal formation in both detector types will be presented. The single detector spatial resolution of 80 {mu}m was measured using a fast Gassiplex based strip readout with readout strips of 150 {mu}m width and a pitch of 250 {mu}m. The Gassiplex readout, formerly used at the HERMES experiment, had to be substantially adapted. No more crosstalk or non-linearities were observed after reconfiguration of the multiplexing amplifier on the front-end boards. The observed spatial resolution is limited by multiple scattering of the cosmic muons used in the laboratory. We also report on the sensitivity to gamma- and neutron background and on the behaviour of spatial resolution as a function of background rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗