High-throughput simulations reveal membrane-mediated effects of alcohols on MscL gating

The mechanosensitive channels of large conductance (MscL) are bacterial membrane proteins that serve as last resort emergency release valves in case of severe osmotic downshock. Sensing bilayer tension, MscL channels are sensitive to changes in the bilayer environment and are, therefore, an ideal test case for exploring membrane protein coupling. Here, we use high-throughput coarse-grained molecular dynamics simulations to characterize MscL gating kinetics in different bilayer environments under the influence of alcohols. We performed over five hundred simulations to obtain sufficient statistics to reveal the subtle effects of changes in the membrane environment on MscL gating. MscL opening times were found to increase with the addition of the straight-chain alcohols ethanol, octanol, and to some extent dodecanol but not with hexadecanol. Increasing concentration of octanol increased the impeding effect, but only up to 10–20 mol %. Our in silico predictions were experimentally confirmed using reconstituted MscL in a liposomal fluorescent efflux assay. Our combined data reveal that the effect of alcohols on MscL gating arises not through specific binding sites but through a combination of the alcohol-induced changes to a number of bilayer properties and their alteration of the MscL–bilayer interface. Finally, our work provides a key example of how extensive molecular simulations can be used to predict the functional modification of membrane proteins by subtle changes in their bilayer environment.

59 BASIC BIOLOGICAL SCIENCES↗

Force transduction and lipid binding in MscL: A continuum-molecular approach

The bacterial mechanosensitive channel MscL, a small protein mainly activated by membrane tension, is a central model system to study the transduction of mechanical stimuli into chemical signals. Mutagenic studies suggest that MscL gating strongly depends on both intra-protein and interfacial lipid-protein interactions. However, there is a gap between this detailed chemical information and current mechanical models of MscL gating. Here, we investigate the MscL bilayer-protein interface through molecular dynamics simulations, and take a combined continuum-molecular approach to connect chemistry and mechanics. We quantify the effect of membrane tension on the forces acting on the surface of the channel, and identify interactions that may be critical in the force transduction between the membrane and MscL. We find that the local stress distribution on the protein surface is largely asymmetric, particularly under tension, with the cytoplasmic side showing significantly larger and more localized forces, which pull the protein radially outward. The molecular interactions that mediate this behavior arise from hydrogen bonds between the electronegative oxygens in the lipid headgroup and a cluster of positively charged lysine residues on the amphipathic S1 domain and the C-terminal end of the second trans-membrane helix. We take advantage of this strong interaction (estimated to be 10–13 kT per lipid) to actuate the channel (by applying forces on protein-bound lipids) and explore its sensitivity to the pulling magnitude and direction. We conclude by highlighting the simple motif that confers MscL with strong anchoring to the bilayer, and its presence in various integral membrane proteins including the human mechanosensitive channel K2P1 and bovine rhodopsin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The voltage-dependence of MscL has dipolar and dielectric contributions and is governed by local intramembrane electric field

Channels without canonical voltage sensors can be modulated by voltage acting on other domains. Here we show that besides protein dipoles, pore hydration can be affected by electric fields. In patches, both WT MscL and its V23T mutant show a decrease in the tension midpoint with hyperpolarization. The mutant exhibits a stronger parabolic dependence of transition energy on voltage, highly consistent with the favourable dielectric contribution from water filling the expanding pore. Purified V23T MscL in DPhPC droplet interface bilayers shows a similar voltage dependence. When reconstituted in an asymmetric DOPhPC/DPhPC bilayer carrying a permanent bias of ~130mV due to a dipole potential difference between the interfaces, the channel behaved as if the local intramembrane electric field sets the tension threshold for gating rather than just the externally applied voltage. The data emphasize the roles of polarized water in the pore and interfacial lipid dipoles in channel gating thermodynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating a role for the cytoplasmic domain in the Mycobacterium tuberculosis mechanosensitive channel of large conductance

Microbial survival in dynamic environments requires the ability to successfully respond to abrupt changes in osmolarity. The mechanosensitive channel of large conductance (MscL) is a ubiquitous channel that facilitates the survival of bacteria and archaea under severe osmotic down-shock conditions by relieving excess turgor pressure in response to increased membrane tension. A prominent structural feature of MscL, the cytoplasmic C-terminal domain, has been suggested to influence channel assembly and function. In this report, we describe the X-ray crystal structure and electrophysiological properties of a C-terminal domain truncation of the Mycobacterium tuberculosis MscL (MtMscLΔC). A crystal structure of MtMscLΔC solubilized in the detergent n-dodecyl-β-D-maltopyranoside reveals the pentameric, closed state-like architecture for the membrane spanning region observed in the previously solved full-length MtMscL. Electrophysiological characterization demonstrates that MtMscLΔC retains mechano-sensitivity, but with conductance and tension sensitivity more closely resembling full length EcMscL than MtMscL. This study establishes that the C-terminal domain of MtMscL is not required for oligomerization of the full-length channel, but rather influences the tension sensitivity and conductance properties of the channel. The collective picture that emerges from these data is that each MscL channel structure has characteristic features, highlighting the importance of studying multiple homologs.

59 BASIC BIOLOGICAL SCIENCES↗

Engineering osmolysis susceptibility in Cupriavidus necator and Escherichia coli for recovery of intracellular products

Intracellular biomacromolecules, such as industrial enzymes and biopolymers, represent an important class of bio-derived products obtained from bacterial hosts. A common key step in the downstream separation of these biomolecules is lysis of the bacterial cell wall to effect release of cytoplasmic contents. Cell lysis is typically achieved either through mechanical disruption or reagent-based methods, which introduce issues of energy demand, material needs, high costs, and scaling problems. Osmolysis, a cell lysis method that relies on hypoosmotic downshock upon resuspension of cells in distilled water, has been applied for bioseparation of intracellular products from extreme halophiles and mammalian cells. However, most industrial bacterial strains are non-halotolerant and relatively resistant to hypoosmotic cell lysis. To overcome this limitation, we developed two strategies to increase the susceptibility of non-halotolerant hosts to osmolysis using Cupriavidus necator, a strain often used in electromicrobial production, as a prototypical strain. In one strategy, C. necator was evolved to increase its halotolerance from 1.5% to 3.25% (w/v) NaCl through adaptive laboratory evolution, and genes potentially responsible for this phenotypic change were identified by whole genome sequencing. The evolved halotolerant strain experienced an osmolytic efficiency of 47% in distilled water following growth in 3% (w/v) NaCl. In a second strategy, the cells were made susceptible to osmolysis by knocking out the large-conductance mechanosensitive channel (mscL) gene in C. necator. When these strategies were combined by knocking out the mscL gene from the evolved halotolerant strain, greater than 90% osmolytic efficiency was observed upon osmotic downshock. A modified version of this strategy was applied to E. coli BL21 by deleting the mscL and mscS (small-conductance mechanosensitive channel) genes. When grown in medium with 4% NaCl and subsequently resuspended in distilled water, this engineered strain experienced 75% cell lysis, although decreases in cell growth rate due to higher salt concentrations were observed. Our strategy is shown to be a simple and effective way to lyse cells for the purification of intracellular biomacromolecules and may be applicable in many bacteria used for bioproduction.

59 BASIC BIOLOGICAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Shale from a vertical well, the Coldstream 1MH Well in Clearfield County, PA. The core is comprised primarily of the Marcellus Shale from a depth of 7,002 to 7,176 ft. The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica shale formations. As part of this effort, bulk scans of core were obtained from the Coldstream 1MH well, provided by the Energy Corporation of America (now Greylock Energy). This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/coldstream-1mh-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. En echelon fractures were observed at 7,100 ft and were CT scanned using NETL’s industrial CT scanner at higher resolution. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provides both a macro and micro description of the core that is relevant for many subsurface energy-related examinations that have traditionally been performed at NETL.

03 NATURAL GAS↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Formation from a vertical well drilled in Greene County, Pennsylvania by the Energy Corporation of America. The core is from the Whipkey ST 1 well, in the Carmichaels Field, and is comprised primarily of the Marcellus Formation from depths of 7,719 to 7,910.8 ft. Core was provided by Tim Carr and Keithan Martin (West Virginia University and ORISE). The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale Formations. As part of this effort, bulk scans of core were obtained from the Whipkey ST 1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/whipkey-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Rogersville Shale from the Smith #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize a core from the Rogersville Shale. This sample was taken from a vertical well, the Jay P. Smith #1 well (47-099-1572), drilled in Wayne County, West Virginia by the Exxon Company in the Elmwood Prospect. The core is comprised primarily of the Rogersville Shale from depths of 11,135 to 11,200.5 ft. This unit is a potential Cambrian oil/gas target, making it of recent interest to multiple groups. The core was provided by the West Virginia Geologic and Economic Survey (WVGES). The primary impetus of this work is a collaboration between WVGES and NETL to characterize core from multiple wells to better understand the structure and variation of key formations in West Virginia (e.g. Crandall et al., 2018a,b). As part of this effort, bulk scans of core were obtained from the Smith #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roger-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provides both a macro and micro description of the core that is relevant for many subsurface energy-related examinations that have traditionally been performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Armstrong #1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Marcellus Formation. The core is from a vertical well (Armstrong #1) drilled in Taylor County, West Virginia by the Petroleum Development Corporation (7,545 to 7,783.4 ft). Core was provided by Phillip Dinterman, West Virginia Geologic and Economical Survey (WVGES) and Tim Carr and Keithan Martin, West Virginia University (WVU). The primary impetus of this work is a collaboration between NETL, WVGES, and WVU to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale formations. As part of this effort, bulk scans of core were obtained from the Armstrong #1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/armstrong-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the CarbonSAFE Seal Integrity Wells in the Illinois Basin

The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) researchers in Morgantown, West Virginia, utilized computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) to evaluate the integrity of three cores (Geophysical Monitor #2 (GM2), Verification Well #1 (VW #1), and Wabash #1 for the Illinois Basin Carbon Storage Assurance Facility Enterprise (CarbonSAFE) efforts. This work was carried out in collaboration with the Illinois State Geological Survey (ISGS) as part of their efforts to analyze cores from two field locations, including the Illinois Basin-Decatur Project (IBDP) and second stage Illinois Industrial Carbon Capture and Storage (IL-ICCS) sites at Decatur, Illinois, and the Wabash CarbonSAFE project at the Wabash Valley Resources Integrated Gasification Combined Cycle plant in Terre Haut, Indiana. The results of this study are presented in several formats and are available online on the Energy Data eXchange (EDX). The rock characterization was conducted using non-destructive techniques, allowing for future analysis of the cores. While the equipment used did not provide direct visualization of shale pore space, it allowed for detection of fractures and discontinuities. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were utilized to identify areas of interest for further study as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy-related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Petrophysical Measurements of the Lively Grove #1 Well Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Lively Grove #1 Well (API 121892494700), drilled near Marissa, Washington County, Illinois. Core from the well was obtained as part of the Illinois Storage Corridor’s Carbon Storage Assurance Facility Enterprise (CarbonSAFE) project (DE FE0031892). The primary impetus of this work was to capture a detailed digital representation of the core from the Lively Grove #1 Well. The collaboration between the U.S. Department of Energy’s (DOE) NETL and the Illinois State Geological Survey (ISGS) enables other research entities to access information about this potential carbon storage location and Cambro-Ordovician Storage Complex formations of the Illinois Basin. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner-acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; with the resulting macro- and micro-descriptions relevant to many subsurface energy related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of Appalachian Basin Core from the Jones and Laughlin #1 Well, Beaver County, PA

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Appalachian Basin core from Beaver County, Pennsylvania. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE) and the Pennsylvania Geological Survey to characterize and make publicly available core information from the Onondaga-Huntersville formations of the Appalachian Basin. This stratigraphic well and the core data produced in this report will aid in understanding the structural complexities of the Onondaga-Huntersville formations. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/jonesandlaughlin1well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with imaging performed with the NETL medical CT scanner over the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for further study. Targeted higher resolution CT scanning of select sections was performed with NETL’s micro-CT scanner. The combination of methods used provides a multiscale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗