Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MSCL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Mechanosensitive channels of Escherichia coli: the MscL gene, protein, and activities

Although mechanosensory responses are ubiquitous and diverse, the molecular bases of mechanosensation in most cases remain mysterious MscL, a mechanosensitive channel of large conductance of Escherichia coli and its bacterial homologues are the first and currently only channel molecules shown to directly sense mechanical stretch of the membrane. In response to the tension conveyed via the lipid bilayer, MscL increases its open probability by several orders of magnitude. In the present review we describe the identification, cloning, and first sets of biophysical and structural data on this simplest mechanosensory molecule. We discovered a 2.5-ns mechanosensitive conductance in giant E. coli spheroplasts. Using chromatographies to enrich the target and patch clamp to assay the channel activity in liposome-reconstituted fractions, we identified the MscL protein and cloned the mscL gene. MscL comprises 136 amino acid residues (15 kDa), with two highly hydrophobic regions, and resides in the inner membrane of the bacterium. PhoA-fusion experiments indicate that the protein spans the membrane twice with both termini in the cytoplasm. Spectroscopic techniques show that it is highly helical. Expression of MscL tandems and covalent cross-linking suggest that the active channel complex is a homo-hexamer. We have identified several residues, which when deleted or substituted, affect channel kinetics or mechanosensitivity. Although unique when discovered, highly conserved MscL homologues in both gram-negative and gram-positive bacteria have been found, suggesting their ubiquitous importance among bacteria.

Non-NASA Center

Energetic and spatial parameters for gating of the bacterial large conductance mechanosensitive channel, MscL

MscL is multimeric protein that forms a large conductance mechanosensitive channel in the inner membrane of Escherichia coli. Since MscL is gated by tension transmitted through the lipid bilayer, we have been able to measure its gating parameters as a function of absolute tension. Using purified MscL reconstituted in liposomes, we recorded single channel currents and varied the pressure gradient (P) to vary the tension (T). The tension was calculated from P and the radius of curvature was obtained using video microscopy of the patch. The probability of being open (Po) has a steep sigmoidal dependence on T, with a midpoint (T1/2) of 11.8 dyn/cm. The maximal slope sensitivity of Po/Pc was 0.63 dyn/cm per e-fold. Assuming a Boltzmann distribution, the energy difference between the closed and fully open states in the unstressed membrane was DeltaE = 18.6 kBT. If the mechanosensitivity arises from tension acting on a change of in-plane area (DeltaA), the free energy, TDeltaA, would correspond to DeltaA = 6.5 nm2. MscL is not a binary channel, but has four conducting states and a closed state. Most transition rates are independent of tension, but the rate-limiting step to opening is the transition between the closed state and the lowest conductance substate. This transition thus involves the greatest DeltaA. When summed over all transitions, the in-plane area change from closed to fully open was 6 nm2, agreeing with the value obtained in the two-state analysis. Assuming a cylindrical channel, the dimensions of the (fully open) pore were comparable to DeltaA. Thus, the tension dependence of channel gating is primarily one of increasing the external channel area to accommodate the pore of the smallest conducting state. The higher conducting states appear to involve conformational changes internal to the channel that don't involve changes in area.

Non-NASA Center

Towards an understanding of the structural and functional properties of MscL, a mechanosensitive channel in bacteria

Whether it be to sense a touch, arterial pressure, or an osmotic gradient across a cell membrane, essentially all living organisms require the capability of detecting mechanical force. Electrophysiological evidence has suggested that mechanosensitive ion channels play a major role in many systems where mechanical force is detected. But, despite their biological importance, determination of the most basic structural and functional features of mechanosensitive channels has only recently become possible. A gene called mscL, which was isolated from Escherichia coli, was the first gene shown to encode a mechanosensitive channel activity. This channel directly responds to tension in the membrane; no other proteins are required. MscL appears to be a homohexamer of a 136 amino acid polypeptide that is highly alpha helical, contains two transmembrane domains, and has both the amino and carboxyl termini in the cytoplasm. The study of the MscL protein remains, to date, one of the most viable options for understanding the structural and functional characteristics of a mechanosensitive channel.

NASA Discipline Cell Biology

Structural models of the MscL gating mechanism

Three-dimensional structural models of the mechanosensitive channel of large conductance, MscL, from the bacteria Mycobacterium tuberculosis and Escherichia coli were developed for closed, intermediate, and open conformations. The modeling began with the crystal structure of M. tuberculosis MscL, a homopentamer with two transmembrane alpha-helices, M1 and M2, per subunit. The first 12 N-terminal residues, not resolved in the crystal structure, were modeled as an amphipathic alpha-helix, called S1. A bundle of five parallel S1 helices are postulated to form a cytoplasmic gate. As membrane tension induces expansion, the tilts of M1 and M2 are postulated to increase as they move away from the axis of the pore. Substantial expansion is postulated to occur before the increased stress in the S1 to M1 linkers pulls the S1 bundle apart. During the opening transition, the S1 helices and C-terminus amphipathic alpha-helices, S3, are postulated to dock parallel to the membrane surface on the perimeter of the complex. The proposed gating mechanism reveals critical spatial relationships between the expandable transmembrane barrel formed by M1 and M2, the gate formed by S1 helices, and "strings" that link S1s to M1s. These models are consistent with numerous experimental results and modeling criteria.

NASA Discipline Cell Biology

The gating mechanism of the large mechanosensitive channel MscL

The mechanosensitive channel of large conductance, MscL, is a ubiquitous membrane-embedded valve involved in turgor regulation in bacteria. The crystal structure of MscL from Mycobacterium tuberculosis provides a starting point for analysing molecular mechanisms of tension-dependent channel gating. Here we develop structural models in which a cytoplasmic gate is formed by a bundle of five amino-terminal helices (S1), previously unresolved in the crystal structure. When membrane tension is applied, the transmembrane barrel expands and pulls the gate apart through the S1-M1 linker. We tested these models by substituting cysteines for residues predicted to be near each other only in either the closed or open conformation. Our results demonstrate that S1 segments form the bundle when the channel is closed, and crosslinking between S1 segments prevents opening. S1 segments interact with M2 when the channel is open, and crosslinking of S1 to M2 impedes channel closing. Gating is affected by the length of the S1-M1 linker in a manner consistent with the model, revealing critical spatial relationships between the domains that transmit force from the lipid bilayer to the channel gate.

Non-NASA Center

Stoichiometry of the large conductance bacterial mechanosensitive channel of E. coli. A biochemical study

MscL, a 15 kDa transmembrane protein, is the only component involved in the formation of a 3 nS channel in the inner membrane of Escherichia coli that opens in response to mechanical or osmotic stress. While previous data had suggested that the functional MscL complex might be a hexamer, a recent crystallographic study of the MscL homologue from M. tuberculosis reveals a pentameric structure. The present work further examines the stoichiometry of the E. coli MscL using a variety of biochemical approaches. Detergent-purified 6His-MscL in solution and MscL in the membrane could be chemically crosslinked with the products displaying ladderlike patterns on SDS gels. Three crosslinking agents (EDC, DMS, and DMA) used at saturating concentrations invariably generated pentamers as the largest product. DSS produced additional bands corresponding to larger complexes although the pentamer band appeared to be the predominant product at high levels of crosslinker. It is not clear whether these extra bands reflect a difference in the crosslinking chemistry of DSS or whether its spacer arm is the longest of those used, or a combination of both facts. For the detergent-solubilized 6His-MscL both sedimentation equilibrium and gel chromatography showed the presence of multiple species. Thus the longer spacer arm could permit both intra- and intercomplex linkages. Nonetheless, the patterns obtained with all agents are consistent with and strongly suggest a pentameric organization for the MscL channel. Expression of MscL as genetically engineered double or triple subunit tandems yields low numbers of functional channels as compared to expressed monomers. The double-tandem assemblies must have an even number of subunits and crosslinking in the membrane confirmed hexamerization. Gel chromatography clearly demonstrated that the channels formed from the double tandems were larger than those formed from WT MscL, consistent with the native channel being pentameric. The observation that both double and triple tandems form channels of normal conductance implies that the pentameric assembly is to some degree independent of the number of subunit repeats in the polypeptide precursor. The channel is thus a pentameric core with the 'extra' subunits left out of the functional complex. From sedimentation equilibrium and size-exclusion chromatography, we also conclude that MscL complexes are not in a dynamic equilibrium with monomers, but are pre-assembled; and thus, their gating properties must result from changes in the conformation of the entire complex induced by the mechanical stress.

NASA Discipline Cell Biology

Mechanosensitive channels in bacteria as membrane tension reporters

The purpose of this short review is to discuss recent data on the molecular structure and mechanism of gating of MscL, a mechanosensitive channel of large conductance from Escherichia coli. MscL is the first isolated molecule shown to convert mechanical stress of the membrane into a simple response, the opening of a large aqueous pore. The functional complex appears to be a stable homo-pentamer of 15-kDa subunits, the gating transitions in which are driven by stretch forces conveyed through the lipid bilayer. We have measured the open probability of MscL and the kinetics of transitions as a function of membrane tension. The parameters extracted from the single-channel current recordings and dose-response curves such as the energy difference between the closed, open, and intermediate conducting states, and the transition-related changes in protein dimensions suggest a large conformational rearrangement of the channel complex. The estimations show that in native conditions MscL openings could be driven primarily by forces of osmotic nature. The thermodynamic and spatial parameters reasonably correlate with the available data on the structure of a single MscL subunit and multimeric organization of the complex. Combined with the functional analysis of mutations, these data give grounds to hypotheses on the nature of the channel mechanosensitivity.

Review

A large iris-like expansion of a mechanosensitive channel protein induced by membrane tension

MscL, a bacterial mechanosensitive channel of large conductance, is the first structurally characterized mechanosensor protein. Molecular models of its gating mechanisms are tested here. Disulfide crosslinking shows that M1 transmembrane alpha-helices in MscL of resting Escherichia coli are arranged similarly to those in the crystal structure of MscL from Mycobacterium tuberculosis. An expanded conformation was trapped in osmotically shocked cells by the specific bridging between Cys 20 and Cys 36 of adjacent M1 helices. These bridges stabilized the open channel. Disulfide bonds engineered between the M1 and M2 helices of adjacent subunits (Cys 32-Cys 81) do not prevent channel gating. These findings support gating models in which interactions between M1 and M2 of adjacent subunits remain unaltered while their tilts simultaneously increase. The MscL barrel, therefore, undergoes a large concerted iris-like expansion and flattening when perturbed by membrane tension.

NASA Discipline Cell Biology

Single residue substitutions that change the gating properties of a mechanosensitive channel in Escherichia coli

MscL is a channel that opens a large pore in the Escherichia coli cytoplasmic membrane in response to mechanical stress. Previously, we highly enriched the MscL protein by using patch clamp as a functional assay and cloned the corresponding gene. The predicted protein contains a largely hydrophobic core spanning two-thirds of the molecule and a more hydrophilic carboxyl terminal tail. Because MscL had no homology to characterized proteins, it was impossible to predict functional regions of the protein by simple inspection. Here, by mutagenesis, we have searched for functionally important regions of this molecule. We show that a short deletion from the amino terminus (3 amino acids), and a larger deletion of 27 amino acids from the carboxyl terminus of this protein, had little if any effect in channel properties. We have thus narrowed the search of the core mechanosensitive mechanism to 106 residues of this 136-amino acid protein. In contrast, single residue substitutions of a lysine in the putative first transmembrane domain or a glutamine in the periplasmic loop caused pronounced shifts in the mechano-sensitivity curves and/or large changes in the kinetics of channel gating, suggesting that the conformational structure in these regions is critical for normal mechanosensitive channel gating.

Non-NASA Center

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT

Mechanosensitive Ion Channels in Bacteria: Functional Domains and Mechanisms of Gating

The past funding period was productive for the group. The progress in the mechanosensitive channel field was critically affected in the end of 1998 by the solution of the crystal structure of the mycobacterial homolog of MscL by our colleagues from Caltech. Having the structure of TbMscL in the closed state, we developed a detailed homology model of EcoMscL, and related the structural model with the wealth of functional phenomenology available for the E. coli version of the channel (EcoMscL). The biophysical properties of the open MscL helped to model the open conformation and infer the pathway for the entire gating transition. The following experiments provided strong support to the atomic model of the gating process, and allowed to make further predictions. The work has advanced our understanding of tension-driven conformational transitions in membrane-embedded mechanosensory proteins, determine major energetic contributions and set the stage for further exploration of the whole family of mechanosensitive channels. The results have been published in seven experimental and theoretical papers, with three other papers currently in press or in preparation.

Sukharev, Sergei

Helicity, membrane incorporation, orientation and thermal stability of the large conductance mechanosensitive ion channel from E. coli

In this report, we present structural studies on the large conductance mechanosensitive ion channel (MscL) from E. coli in detergent micelles and lipid vesicles. Both transmission Fourier transform infrared spectroscopy and circular dichroism (CD) spectra indicate that the protein is highly helical in detergents as well as liposomes. The secondary structure of the proteins was shown to be highly resistant towards denaturation (25-95 degrees C) based on an ellipticity thermal profile. Amide H+/D+ exchange was shown to be extensive (ca. 66%), implying that two thirds of the protein are water accessible. MscL, reconstituted in oriented lipid bilayers, was shown to possess a net bilayer orientation using dichroic ratios measured by attenuated total-reflection Fourier transform infrared spectroscopy. Here, we present and discuss this initial set of structural data on this new family of ion-channel proteins.

NASA Discipline Cell Biology

Evaluating the effect of accuracy ratios on the percent of calibrations which are out of tolerance

The standard practice in calibration laboratories across the country, including the Measurement Standards and Calibration Laboratory (MSCL) at the Johnson Space Center, is to use accuracy ratios to determine if instruments are in-tolerance rather than computing the actual uncertainty associated with the instruments. In the past, the accepted practice was to use an accuracy ratio of 10:1, but then state of the art advanced to the point where the 10:1 ratio could no longer be maintained, and the ratio was arbitrarily lowered to 4:1. It is now becoming increasingly difficult to maintain the 4:1 accuracy ratio, and in some cases 1:1 is the best that can be achieved. However, the effect of using these small accuracy ratios on the number of mistakes made in classifying instruments as in or out of tolerance is completely unknown. In order to assess the effect of using accuracy ratios in calibration, a simulation program was written to compute the proportion of instruments determined to be out of tolerance which were actually in, denoted by alpha, and the proportion of instruments determined to be in-tolerance which were actually out, denoted by beta. This was done for accuracy ratios of 1:1 and 10:1, for one to five progressive calibrations, under varying standard and instrument conditions. Selected results are presented and explained.

Navard, Sharon E.

CORECM Williston Basin Twin Butte and Hagel Coal Wells

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations" by Paronish et al., 2024

Coal

WARE 1-9 Well

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the J. F. WARE Gas Unit 1-9 Well in Smith County, Texas" by Brinza et al. , 2024.

CoreCM