Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Paris-Edinburgh Cell for High-Pressure and High-Temperature Structure Studies on Silicate Liquids Using Monochromatic Synchrotron Radiation

A Paris-Edinburgh press combined with a multi-channel collimator assembly has been commissioned at the GeoSoilEnviro Center for Advanced Radiation Sources (GSECARS) beamline for monochromatic X-ray scattering, with an emphasis on studying low-Z liquids, especially silicate liquids at high pressure. The Paris-Edinburgh press is mounted on a general-purpose diffractometer, with a pixel array detector mounted on the detector arm. The incident monochromatic undulator beam with energies up to 60 keV is focused both horizontally and vertically to a beam size about 30 × 30 µm. With this setup, background scattering from the surrounding pressure media is completely removed at 2θ angles above 10° for samples larger than 1.05 mm in diameter. Thirty minutes is typically sufficient to collect robust X-ray scattering signals from a 1.6 mm diameter amorphous silicate sample. Cell assemblies for the standard Paris-Edinburgh anvils have been developed and pressures and temperatures up to 7 GPa and 2300 K, respectively, have been maintained steadily over hours. We have also developed a cupped-toroidal Drickamer anvil to further increase pressure and temperature capabilities. The cupped-toroidal Drickamer anvil combines features of a modified Drickamer anvil and the traditional Paris-Edinburgh anvil. Pressures up to 12 GPa have been generated at temperatures up to 2100 K.

58 GEOSCIENCES↗

Attenuation of Scattered Monochromatic Synchrotron Radiation in Iron and Lead

Attenuation curves have been calculated with STAC8 for photon radiation scattered by silicon target. Monochromatic beam with energies from 20 keV to 150 keV has been considered. The materials studies were those typical of hutch shielding (iron or lead). Three examples, showing how to use these curves for shielding design are included.

36 MATERIALS SCIENCE↗

Phase transition in two-dimensional monolayer (1L)-molybdenum disulfide induced by atomic S-basal plane gliding via synchrotron X-ray monochromatic beam radiation for superior electronic performance

Here, in this work, we report a novel approach to reduce the channel resistance by inducing a phase transition behavior from 2H to 1T in a monolayer MoS 2 (1L-MoS 2 ) by a synchrotron X-ray monochromatic beam (mono-beam) radiation. The effects of the biphase structure by the mono-beam on the 1L-MoS2 film were investigated using Raman spectra, photoluminescence (PL) spectra, scanning tunneling microscopy, and scanning tunneling spectroscopy, respectively. Through material characterization, we identified that the lateral sliding of S-vacancies along the S-plane in the 1L-MoS 2 is the key reason for the origin of unidirectional phase transition. The precise phase engineering triggered by the mono-beam radiation process allows the realization of field-effect transistors (FET) with 2X improvement in mobility toward a high on/off ratio (~10 8 ) and a near-ideal subthreshold swing of ~88 mV per decade. The validity of the phase engineering could be further extended for its application as a memory device, exhibiting a gate tunable conduction modulation behavior and a high resistance ratio of ~10 2 at a gate bias of 5 V with endurance of ~100 cycles. Furthermore, an artificial neural network using the synaptic weight update with accuracy of ~93 % was achieved.

36 MATERIALS SCIENCE↗

On contrast of biological X-ray nanomicroscopy

We analyse the absorption contrast of histological and cytological preparations, which can be achieved in nanomicroscopic studies using monochromatic radiation in the spectral range of 90 – 600 eV (14 – 2 nm). Two types of unstained biological objects are considered: untreated and fixed in paraffin, and optimum wavelengths are determined for the study of samples with a thickness of 0.5 – 10 μm with a spatial resolution of 100 – 20 nm. Taking into account the efficiency of X-ray optics, the number of source photons required to produce a single image is estimated. It is shown that the greatest interest for the study of fixed objects represents the spectral region of 7 – 14 nm, for which, on the basis of rapidly developing compact sources of incoherent and coherent radiation and effective optics, microscopes for scientific and clinical research can be designed. (paper)

60 APPLIED LIFE SCIENCES↗

Photovoltaic Characteristics of AlGaAs-Based LEDs

Photovoltaic characteristics of more than 20 types of AlGaAs-based light-emitting diodes operating in the 830- to 970-nm wavelength range have been considered. It is established that Al{sub x}Ga{sub 1–} {sub x}As semiconductor structures employed in these devices can also be used for manufacturing photovoltaic converters of monochromatic radiation with quite high efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scattering of electromagnetic pulses on metallic nanospheres with the inclusion of plasmon interference effects

The spectral–angular features of the scattering of electromagnetic pulses with various durations (from quasimonochromatic to ultrashort) on metallic nanoparticles in a dielectric medium have been studied for various parameters of the problem. It has been shown that the character of the interference of contributions from surface plasmons with various multipole orders significantly depends on the scattering angle and is responsible for sharp features in the scattering spectrum of monochromatic radiation. The dependence of the probability and scattering spectrum on the duration of a pulse and the scattering angle has been analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modulational excitation of inhomogeneities in dusty ionospheric plasma

The mechanism for the formation of inhomogeneities of the electron and ion densities in dusty ionospheric plasma as a result of the modulational instability of a pump electromagnetic wave caused by the excitation of dust acoustic perturbations is considered. The inhomogeneities of the electron density produced by the monochromatic radiation of heating facilities at altitudes of 80 and 100 km are estimated numerically. The possibility of excitation of relatively large inhomogeneities of the electron and ion densities δn{sub e(i)}/n{sub e(i)} ≈ 0.05 at altitudes of 80–100 km as a result of modulational interaction is demonstrated. The applicability domains of the method presented in this work are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical simulation of multiple Compton backscattering process

A number of laboratories are currently developing monochromatic sources of X-rays and gamma quanta based on the Compton backscattering (CBS) of laser photons by relativistic electrons. Modern technologies are capable of providing a concentration of electrons and photons in the interaction point such that each primary electron can emit several hard photons. In contrast to the well-known nonlinear CBS process, in which an initial electron “absorbs” a few laser photons and emits a single hard one, the above-mentioned process can be called a multiple CBS process and is characterized by a mean number of emitted photons. The present paper is devoted to simulating the parameters of a beam of back scattered quanta based on the Monte Carlo technique. It is shown that, even in the case of strong collimation of a resulting photon beam, the radiation monochromaticity may deteriorate because of the contribution coming from the multiple photon emission, which is something that must be considered while designing new CBS sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous scattering, transport, and spatial distribution of X-ray fluorescence at the exit of polycapillary structures

The angular distribution of the X-ray intensity at the exit of microchannel plates at grazing incidence of monochromatic radiation on the walls of microcapillaries has been investigated. The angles and energies of the primary radiation quanta at which the synchrotron beam excites X-ray fluorescence propagating inside polycapillary structures have been determined. The angular dependences of the intensity distribution of X-rays transmitted through the microcapillaries have been studied theoretically and experimentally for energies corresponding to the region of anomalous dispersion near the L{sub 2,3} absorption edges of silicon. The propagation of waves in hollow polycapillary waveguides, the excitation of X-ray fluorescence, and the X-ray diffraction at the exit of microchannel plates have been modeled mathematically. The mathematical model takes into account the presence of a transition layer on the microchannel surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large area CMOS active pixel sensor x-ray imager for digital breast tomosynthesis: Analysis, modeling, and characterization

Purpose: Large area x-ray imagers based on complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been proposed for various medical imaging applications including digital breast tomosynthesis (DBT). The low electronic noise (50–300 e{sup −}) of CMOS APS x-ray imagers provides a possible route to shrink the pixel pitch to smaller than 75 μm for microcalcification detection and possible reduction of the DBT mean glandular dose (MGD). Methods: In this study, imaging performance of a large area (29 × 23 cm{sup 2}) CMOS APS x-ray imager [Dexela 2923 MAM (PerkinElmer, London)] with a pixel pitch of 75 μm was characterized and modeled. The authors developed a cascaded system model for CMOS APS x-ray imagers using both a broadband x-ray radiation and monochromatic synchrotron radiation. The experimental data including modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE) were theoretically described using the proposed cascaded system model with satisfactory consistency to experimental results. Both high full well and low full well (LFW) modes of the Dexela 2923 MAM CMOS APS x-ray imager were characterized and modeled. The cascaded system analysis results were further used to extract the contrast-to-noise ratio (CNR) for microcalcifications with sizes of 165–400 μm at various MGDs. The impact of electronic noise on CNR was also evaluated. Results: The LFW mode shows better DQE at low air kerma (K{sub a} < 10 μGy) and should be used for DBT. At current DBT applications, air kerma (K{sub a} ∼ 10 μGy, broadband radiation of 28 kVp), DQE of more than 0.7 and ∼0.3 was achieved using the LFW mode at spatial frequency of 0.5 line pairs per millimeter (lp/mm) and Nyquist frequency ∼6.7 lp/mm, respectively. It is shown that microcalcifications of 165–400 μm in size can be resolved using a MGD range of 0.3–1 mGy, respectively. In comparison to a General Electric GEN2 prototype DBT system (at MGD of 2.5 mGy), an increased CNR (by ∼10) for microcalcifications was observed using the Dexela 2923 MAM CMOS APS x-ray imager at a lower MGD (2.0 mGy). Conclusions: The Dexela 2923 MAM CMOS APS x-ray imager is capable to achieve a high imaging performance at spatial frequencies up to 6.7 lp/mm. Microcalcifications of 165 μm are distinguishable based on reported data and their modeling results due to the small pixel pitch of 75 μm. At the same time, potential dose reduction is expected using the studied CMOS APS x-ray imager.

60 APPLIED LIFE SCIENCES↗

Mineral density volume gradients in normal and diseased human tissues

Clinical computed tomography provides a single mineral density (MD) value for heterogeneous calcified tissues containing early and late stage pathologic formations. The novel aspect of this study is that, it extends current quantitative methods of mapping mineral density gradients to three dimensions, discretizes early and late mineralized stages, identifies elemental distribution in discretized volumes, and correlates measured MD with respective calcium (Ca) to phosphorus (P) and Ca to zinc (Zn) elemental ratios. To accomplish this, MD variations identified using polychromatic radiation from a high resolution micro-computed tomography (micro-CT) benchtop unit were correlated with elemental mapping obtained from a microprobe X-ray fluorescence (XRF) using synchrotron monochromatic radiation. Digital segmentation of tomograms from normal and diseased tissues (N=5 per group; 40-60 year old males) contained significant mineral density variations (enamel: 2820-3095mg/cc, bone: 570-1415mg/cc, cementum: 1240-1340mg/cc, dentin: 1480-1590mg/cc, cementum affected by periodontitis: 1100-1220mg/cc, hypomineralized carious dentin: 345-1450mg/cc, hypermineralized carious dentin: 1815-2740mg/cc, and dental calculus: 1290-1770mg/cc). A plausible linear correlation between segmented MD volumes and elemental ratios within these volumes was established, and Ca/P ratios for dentin (1.49), hypomineralized dentin (0.32-0.46), cementum (1.51), and bone (1.68) were observed. Furthermore, varying Ca/Zn ratios were distinguished in adapted compared to normal tissues, such as in bone (855-2765) and in cementum (595-990), highlighting Zn as an influential element in prompting observed adaptive properties. Hence, results provide insights on mineral density gradients with elemental concentrations and elemental footprints that in turn could aid in elucidating mechanistic processes for pathologic formations.

59 BASIC BIOLOGICAL SCIENCES↗

Phase Identification in Synchrotron X-ray Diffraction Patterns of Ti–6Al–4V Using Computer Vision and Deep Learning

X-ray diffraction patterns contain information about the atomistic structure and microstructure (defect population) of materials, extracting detailed information from diffraction patterns is complex, demanding and relies on prior knowledge. Here, we hypothesize that deep-learning techniques can help to perform an effective and accurate analysis with high throughput rates. To demonstrate this concept, we applied a novel deep learning framework to determine the evolution of the β-phase volume fraction in a Ti–6Al–4V alloy during heat-treatment from video sequences of 2D diffraction patterns recorded in transmission and with highly monochromatic radiation in a synchrotron beamline. In particular, we studied the impact of network design on prediction reliability and computational performance. Networks of different architectures were trained using 3008 experimental 2D patterns. A well-tuned model was found to reproduce the phase fractions of another experimental data set, consisting of 1100 diffraction patterns, with a mean-square error as small as 2.6 x 10 -4 . The average prediction error of β-phase volume fraction was within 1.6 x 10 -2 (in each diffraction pattern) of the values obtained by conventional methods. Our work demonstrates that convolutional neural networks can evaluate high energy X-ray diffraction patterns with a remarkable level of reliability. Furthermore, it demonstrates the significance of network design on the reliability of predictions and computational performance. The most complex models do not necessarily result in highest accuracy and may even fail to learn from the data.

36 MATERIALS SCIENCE↗

Pink-beam serial crystallography

Serial X-ray crystallography allows macromolecular structure determination at both X-ray free electron lasers (XFELs) and, more recently, synchrotron sources. The time resolution for serial synchrotron crystallography experiments has been limited to millisecond timescales with monochromatic beams. The polychromatic, “pink”, beam provides a more than two orders of magnitude increased photon flux and hence allows accessing much shorter timescales in diffraction experiments at synchrotron sources. Here we report the structure determination of two different protein samples by merging pink-beam diffraction patterns from many crystals, each collected with a single 100 ps X-ray pulse exposure per crystal using a setup optimized for very low scattering background. In contrast to experiments with monochromatic radiation, data from only 50 crystals were required to obtain complete datasets. The high quality of the diffraction data highlights the potential of this method for studying irreversible reactions at sub-microsecond timescales using high-brightness X-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Laser-Electron-Interaction Region for Compact High Repetition-Rate Mono-Energetic Laser Based Gamma Sources

Inverse-Compton scattering (ICS) is a well-established technique capable of producing monochromatic radiation over a large range of the electromagnetic spectrum. Most recently, ICS has attracted attention, owing to its compactness and possible coupling with novel acceleration methods to yield compact X- and 𝛄-ray sources. Under this award, we carried out a systematic optimization of the ICS and demonstrate via numerical simulation that combining ICS with a conventional superconducting linac could produce Watt-level average-power 𝛄 rays with high spectral brightness. The study is performed with idealized laser and electron-beam distributions and confirmed with the realistic distributions simulated from start-to-end numerical modeling of the electron accelerator. The studies led to the design and engineering design of an ICS interaction point for the FAST facility along with some beam measurement. Due to the cancellation of the program in Year 3 long with delay in the commissioning of the FAST facility, we were not able to demonstrate the generation of 𝛄 rays, we, however, procured some of the hardware, installed some of the required infrastructures and plan to eventually generate 𝛄 ray pending future interest on the topics and availability of funding.

43 PARTICLE ACCELERATORS↗

Energy scale calibration of the KEDR tagging system

The KEDR detector tagging system is a symmetric focusing magnetic spectrometer of small-angle electrons born in the interaction region of the VEPP-4M collider. Using this system, which is designed for studying the two-photon processes, the scattered electrons and positrons energy is measured with a resolution of ΔE/E{sub 0}= 0.03–0.6% where E{sub 0} is the beam energy. Two different methods are employed for calibrating the tagging system energy scale: the first one involves the electron/positron tagging by the energy of the singlebremsstrahlung photon measured in the BGO calorimeter, and the second one is based on the determination of the recoil electrons spectrum edge in the Compton backscattering of monochromatic laser radiation. The technical implementation and the present status of the calibration system are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-RAY IRRADIATION OF H{sub 2}O + CO ICE MIXTURES WITH SYNCHROTRON LIGHT

We irradiated a (4:1) mixture of water and carbon monoxide with soft X-rays of energies up to 1.2 keV. The experiments were performed using the spherical grating monochromator beamline at National Synchrotron Radiation Research Center in Taiwan. Both monochromatic (300 and 900 eV) and broader energy fluxes (250–1200 eV) were employed. During the irradiation, the H{sub 2}O + CO mixture was ionized, excited, and fragmented, producing a number of reactive species. The composition of the ice has been monitored throughout both the irradiation and warm-up phases. We identified several products, which can be related through a plausible chemical reaction scheme. Such chemistry is initiated by the injection of energetic photoelectrons that produce multiple ionization events generating a secondary electron cascade. The results have been discussed in light of a model for protoplanetary disks around young solar-type stars.

74 ATOMIC AND MOLECULAR PHYSICS↗

Production of two-colour radiation with polarisations of components rotating in opposite directions

A method is proposed for the production of two-colour radiation with monochromatic components, the polarisation vectors of which rotate in opposite directions, and the rotation speed is controlled by the sound frequency. The method is based on acousto-optic (AO) interaction upon double passage of two-colour radiation through an AO cell made of a gyrotropic crystal; the method efficiency is demonstrated by the example of radiation from an Ar laser generating at wavelengths of 0.488 and 0.514 μm and an AO cell made of TeO{sub 2}, operating at a sound frequency of 60 MHz. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CHEMICAL EVOLUTION OF A CO ICE INDUCED BY SOFT X-RAYS

We irradiated a pure carbon monoxide ice with soft X-rays of energies up to 1.2 keV. The experiments were performed using the spherical grating monochromator beamline at the National Synchrotron Radiation Research Center in Taiwan, exploiting both monochromatic (at 0.3 and 0.55 keV) and broader energy (0.25–1.2 keV) fluxes. The infrared spectra of the irradiated ices showed the formation of a number of products such as polycarbon mono- and dioxides C{sub n}O{sub m}, and chains containing up to 10 carbon atoms. While a gentle increase in the energy absorbed by the ice sample is reflected by an increase in the column densities of newly born species, such correlation breaks down at very high fluxes. In this regime the production yield falls down sharply by about a factor of 100. The refractory residue obtained in the broad energy irradiation is a “compromise” between those obtained with proton irradiation of C{sub 3}O{sub 2} and CO ices in previous experiments. Finally, we discuss the possible implications for space chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗