Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MIMO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The 2010 ILSO-ISRU Field Test at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

For the advanced Moessbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform X-ray fluorescence analysis simultaneously to Moessbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The ISRU 2010 field campaign demonstrated that in-situ Moessbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

Klingelhoefer, G.↗

The ISRU Field Tests 2010 and 2012 at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

The 2010 and 2012 In-Situ Resource Utilization Analogue Test (ISRU) [1] on the Mauna Kea volcano in Hawai'i was coordinated by the Northern Centre for Advanced Technology (NORCAT) in collaboration with the Canadian Space Agency (CSA), the German Aerospace Center (DLR), and the National Aeronautics and Space Administration (NASA), through the PISCES program. Several instruments were tested as reference candidates for future analogue testing at the new field test site at the Mauna Kea volcano in Hawai'i. The fine-grained, volcanic nature of the material is a suitable lunar and martian analogue, and can be used to test excavation, site preparation, and resource utilization techniques. The 2010 location Pu'u Hiwahine, a cinder cone located below the summit of Mauna Kea (19deg45'39.29" N, 155deg28'14.56" W) at an elevation of ~2800 m, provides a large number of slopes, rock avalanches, etc. to perform mobility tests, site preparation or resource prospecting. Besides hardware testing of technologies and systems related to resource identification, also in situ science measurements played a significant role in integration of ISRU and science instruments. For the advanced Mössbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform Xray fluorescence analysis simultaneously to Mössbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The 2010 and 2012 field campaigns demonstrated that in-situ Mössbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

Klingelhoefer, G.↗

The Miniaturized Moessbauer Spectrometers MIMOS II on MER: Four Years of Operation - A Summary

The two Miniaturized Moessbauer Spectrometers (MIMOS II) on board the two Mars Exploration Rovers Spirit and Opportunity have now been collecting important scientific data for more than four years. The spectrometers provide information about Fe-bearing mineral phases and determine Fe oxidation states. The total amount of targets analized exceeds 600, the total integration time exceeds 260 days for both rovers. Since landing, more than five half-lives of the Co-57 MB sources have past (intensity at the time of landing approx. 150 mCi). Current integration times are about 50 hours in order to achieve reasonable statistics as opposed to 8 hours at the beginning of the mission. In total, 13 different mineral phases were detected: Olivine, pyroxene, hematite, magnetite and nanophase ferric oxide were detected at both landing sites. At Gusev, ilmenite, goethite, a ferric sulfate phase and a yet unassigned phase (in the rock Fuzzy Smith) were detected. At Meridiani, jarosite, metallic iron in meteoritic samples (kamacite), troilite, and an unassigned ferric phase were detected. Jarosite and goethite are of special interest, as these minerals are indicators for water activity. In this abstract, an overview of Moessbauer results will be given, with a focus on data obtained since the last martian winter. The MER mission has proven that Moessbauer spectroscopy is a valuable tool for the in situ exploration of extraterrestrial bodies and for the study of Febearing samples. The experience gained through the MER mission makes MIMOS II a obvious choice for future missions to Mars and other targets. Currently, MIMOS II is on the scientific payload of two approved future missions: Phobos Grunt (Russian Space Agency; 2009) and ExoMars (European Space Agency; 2013).

Fleischer, I.↗

Cellular Based Small Unmanned Aircraft Systems MIMO Communications

The use of remotely piloted unmanned aircraft systems/vehicles (UAS/UAV or drones) increases dramatically in recent years. This paper discusses the use of multiple-input and multiple-output (MIMO) technologies in cellular (i.e., LTE) based small UAS (sUAS) communications. More specifically, we will first provide background information about this work, followed by a review of state-of-the-art. Then, we will discuss the benefits of MIMO technologies and propose practical MIMO configurations (e.g., the type, size and number of antennas) that are suitable for NASA's sUAS research and operations. Finally, the design tradeoff among multiplexing, diversity, and interference/jamming cancellation will also be discussed.

Li, Hongxiang↗

Cellular Based Small Unmanned Aircraft Systems (sUAS) MIMO Communications

The use of remotely piloted unmanned aircraft systems/vehicles (UAS/UAV or drones) increases dramatically in recent years. This paper discusses the use of multiple-input and multiple-output (MIMO) technologies in cellular (i.e., LTE) based small UAS (sUAS) communications. More specifically, we will first provide background information about this work, followed by a review of state-of-the-art. Then, we will discuss the benefits of MIMO technologies and propose practical MIMO configurations (e.g., the type, size and number of antennas) that are suitable for NASA's sUAS research and operations. Finally, the design tradeoff among multiplexing, diversity, and interference/jamming cancellation will also be discussed.

Li, Hongxiang↗

Model reduction of nonsquare linear MIMO systems using multipoint matrix continued-fraction expansions

This paper deals with the multipoint Cauer matrix continued-fraction expansion (MCFE) for model reduction of linear multi-input multi-output (MIMO) systems with various numbers of inputs and outputs. A salient feature of the proposed MCFE approach to model reduction of MIMO systems with square transfer matrices is its equivalence to the matrix Pade approximation approach. The Cauer second form of the ordinary MCFE for a square transfer function matrix is generalized in this paper to a multipoint and nonsquare-matrix version. An interesting connection of the multipoint Cauer MCFE method to the multipoint matrix Pade approximation method is established. Also, algorithms for obtaining the reduced-degree matrix-fraction descriptions and reduced-dimensional state-space models from a transfer function matrix via the multipoint Cauer MCFE algorithm are presented. Practical advantages of using the multipoint Cauer MCFE are discussed and a numerical example is provided to illustrate the algorithms.

Guo, Tong-Yi↗

The Miniaturized Mossbauer Spectrometer MIMOS II for the Asteroid Redirect Mission (ARM): Quantitative Iron Mineralogy and Oxidation States

The miniaturized Mossbauer spectrometer MIMOS II is an off-the-shelf instrument, which has been successfully deployed during NASA's Mars Exploration Rover (MER) mission and was on-board the ESA/UK Beagle 2 Mars lander and the Russian Phobos-Grunt sample return mission. We propose to use a fully-qualified flight-spare MIMOS II instrument available from these missions for in situ asteroid characterization with the Asteroid Redirect Robotic Mission (ARRM).

Schroder, Christian↗

Investigation of Multi-Input, Multi-Output (MIMO) Random Control Applied to Direct Field Acoustic Testing

Direct Field Acoustic Testing (DFAT) offers potential cost and time savings over reverberant chamber acoustic testing of spacecraft. The NASA Multi-Purpose Crew Vehicle (MPCV) Program recently directed a series of acoustic tests on Orion structural test articles comparing DFAT and reverberant testing of the same test article with a view to qualifying DFAT for manned space flight vehicles. The verification process compared four parameters noise level compliance with the one third octave test specification, spatial uniformity of the acoustic field, spatial correlation of the acoustic field and vibration response of vehicle structure, including representative solar array panels. While the results of the verification were encouraging, MPCV Loads and Dynamics engaged Quartus Engineering to investigate whether alternative MIMO random control strategies might improve the spatial uniformity and/or the spatial correlation of the DFAT acoustic field. This paper presents the results of acoustic field simulations of the DFAT test and provides a better understanding of how MIMO random control systems originally developed for vibration and structural durability testing can be expected to perform in DFAT testing.

Direct Field↗

Tracking and disturbance rejection of MIMO nonlinear systems with PI controller

The tracking and disturbance rejection of a class of MIMO nonlinear systems with linear proportional plus integral (PI) compensator is studied. Roughly speaking, it is shown that if the given nonlinear plant is exponentially stable and has a strictly increasing dc steady-state I/O map, then a simple PI compensator can be used to yield a stable unity-feedback closed-loop system which asymptotically tracks reference inputs that tend to constant vectors and asymptotically rejects disturbances that tend to constant vectors.

Desoer, C. A.↗

Tracking and disturbance rejection of MIMO nonlinear systems with PI controller

The tracking and disturbance rejection of a class of MIMO nonlinear systems with a linear proportional plus integral (PI) compensator is studied. Roughly speaking, it is shown that if the given nonlinear plant is exponentially stable and has a strictly increasing dc steady-state I/O map, then a simple PI compensator can be used to yield a stable unity-feedback closed-loop system which asymptotically tracks reference inputs that tend to constant vectors and asymptotically rejects disturbances that tend to constant vectors.

Desoer, C. A.↗

Antiwindup analysis and design approaches for MIMO systems

Performance degradation of multiple-input multiple-output (MIMO) control systems having limited actuators is often handled by augmenting the controller with an antiwindup mechanism, which attempts to maintain system performance when limits are encountered. The goals of this paper are: 1) to develop a method to analyze antiwindup systems to determine precisely what stability and performance degradation is incurred under limited conditions. It is shown that by reformulating limited actuator commands as resulting from multiplicative perturbations to the corresponding controller requests, mu-analysis tools can be utilized to obtain quantitative measures of stability and performance degradation. 2) To propose a linear, time invariant (LTI) criterion on which to base the antiwindup design. These analysis and design methods are illustrated through the evaluation of two competing antiwindup schemes augmenting the controller of a Short Take-Off and Vertical Landing (STOVL) aircraft in transition flight.

Marcopoli, Vincent R.↗

Antiwindup analysis and design approaches for MIMO systems

Performance degradation of multiple-input multiple-output (MIMO) control systems having limited actuators is often handled by augmenting the controller with an antiwindup mechanism, which attempts to maintain system performance when limits are encountered. The goals of this paper are: (1) To develop a method to analyze antiwindup systems to determine precisely what stability and performance degradation is incurred under limited conditions. It is shown that by reformulating limited actuator commands as resulting from multiplicative perturbations to the corresponding controller requests, mu-analysis tools can be utilized to obtain quantitative measures of stability and performance degradation. (2) To propose a linear, time invariant (LTI) criterion on which to base the antiwindup design. These analysis and design methods are illustrated through the evaluation of two competing antiwindup schemes augmenting the controller of a Short Take-Off and Vertical Landing (STOVL) aircraft in transition flight.

Marcopoli, Vincent R.↗

MIMO Sliding Mode Control for a Tailless Fighter Aircraft, An Alternative to Reconfigurable Architectures

A frequency-domain procedure for the design of sliding mode controllers for multi-input, multi-output (MIMO) systems is presented. The methodology accommodates the effects of parasitic dynamics such as those introduced by unmodeled actuators through the introduction of multiple asymptotic observers and model reference hedging. The design procedure includes a frequency domain approach to specify the sliding manifold, the observer eigenvalues, and the hedge model. The procedure is applied to the development of a flight control system for a linear model of the Innovative Control Effector (ICE) fighter aircraft. The stability and performance robustness of the resulting design is demonstrated through the introduction of significant degradation in the control effector actuators and variation in vehicle dynamics.

Wells, S. R.↗

The Miniaturized Moessbauer Spectrometer MIMOS II of the Athena Payload for the 2003 MER Missions

A first-order requirement of spacecraft missions that land on Mars is instrumentation for in situ mineralogical analysis. Moessbauer Spectroscopy is a powerful tool for quantitative analysis of Fe-bearing materials. The Athena Moessbauer spectrometer MIMOS II on the martian surface will provide: (1) identification of iron-bearing phases (e.g., oxides, silicates, sulfides, sulfates, and carbonates), (2) quantitative measurement of the distribution of iron among its oxidation states (e.g., Fe(2+)/Fe(3+) ratio), and (3) quantitative measurement of the distribution of iron among iron-bearing phases (e.g., the relative proportions of iron in olivine, pyroxene, and magnetite in a basalt) in rocks and soils. Moessbauer data will also be highly complementary with chemical analyses from the APXS and the Mini-TES compositional data. Mars is a particularly good place to do Moessbauer mineralogy because its surface is iron rich (approx. 20% Fe as Fe2O3). Moessbauer spectrometers that are built with backscatter measurement geometry require no sample preparation, a factor important for in situ planetary measurements.

G Klingelhoefer↗

MIMOS II on MER One Year of Mossbauer Spectroscopy on the Surface of Mars: From Jarosite at Meridiani Planum to Goethite at Gusev Crater

The miniaturized Mossbauer (MB) spectrometer MIMOS II [1] is part of the Athena payload of NASA s twin Mars Exploration Rovers "Spirit" (MER-A) and "Opportunity" (MER-B). It determines the Fe-bearing mineralogy of Martian soils and rocks at the Rovers respective landing sites, Gusev crater and Meridiani Planum. Both spectrometers performed successfully during first year of operation. Total integration time is about 49 days for MERA (79 samples) and 34 days for MER-B (85 samples). For curiosity it might be interesting to mention that the total odometry of the oscillating part of the MB drive exceeds 35 km for both rovers.

Klingelhoefer, G.↗

Hematite at Meridiani Planum and Gusev Crater as identified by the Moessbauer Spectrometer MIMOS II

The Moessbauer (MB) spectrometers on the MER rovers Opportunity and Spirit, which landed on Mars in January 2004, have identified the iron-containing mineral hematite (a-Fe2O3) at both landing sites. On Earth, hematite can occur either by itself or with other iron oxides as massive deposits, in veins , and as particles dispersed through a silicate or other matrix material. Hematite particle size can range from nanophase (superparamagnetic) to multidomain and particle shape ranges from equant to acicular to platy. Fine-grained hematite is red in color and is a pigmenting agent. Coarse-grained hematite can be spectrally neutral (gray) at visible wavelengths. Substitutional impurities, particularly Al, are common in hematite. Chemically pure, coarse-grained, and well-crystalline hematite has a magnetic transition (the Morin transition) at ~260 K. Moessbauer spectra, recorded as a function of temperature, provide a way to characterize Martian hematite with respect to some of the physical and chemical characteristics. At Meridiani Planum besides the iron-sulfate mineral jarosite also the Fe-oxide hematite has been identified by the Moessbauer spectrometer, mainly in three distinct types of reservoir: - outcrop matrix material dominated by the mineral jarosite in the MB spectrum, certain basaltic soils, and mm-sized spherules dubbed blueberries. Moessbauer spectra of each reservoir yield a distinct set of hyperfine parameters for hematite, suggesting different degrees of crystallinity and particle size. The hematite found by MB instrument MIMOS II in the outcrop material shows the Morin transition at relatively high temperatures (ca. 250 K) which is an indication of pure and well-crystallized hematite. The source of the hematite in the Blueberries as identified by Moessbauer spectroscopy, and also by MiniTES, is not known. These spherules, covering nearly the whole landing site area (Eagle crater, plains, Endurance crater), may be concretions formed in the outcrop involving aqueous processes. They are dispersed throughout the hematite containing jarositic outcrop material. According to Moessbauer analysis the dominating iron-bearing mineral in the spherules is hematite, and jarosite not been detected so far in significant amounts. But there are some places with hematite showing characteristics different from the hematite described above: (1) the soil at B023_HematiteSlope_Hema2 has some blueberries, but the MB did not seem to intercept any. The temperature dependence of its MB parameters are different from those of blueberries. (2) B049_RasberryNewton_Filling shows a unique Hm MB signature, as well as (3) B051_RealSharksTooth_Enamel1.

Klingelhoefer, G.↗

Analysis of 6.4 KEV Moessbauer Spectra Obtained with MIMOS II on MER on Cobbles at Meridiani Planum, Mars and Considerations on Penetration Depths

The miniaturized Moessbauer (MB) spectrometers MIMOS II [1] on board of the two Mars Exploration Rovers Spirit and Opportunity have obtained more than 600 spectra of more than 300 different rock and soil targets [2-7]. Both instruments have simultaneously collected 6.4 keV X-ray and 14.4 keV .-ray spectra in backscattering geometry [1]. With Spirit's MB spectrometer, 6.4 keV and 14.4 keV spectra have been obtained for all targets through sol 461. After this date, only 14.4 keV spectra were collected. With Opportunity's spectrometer, 6.4 keV and 14.4 keV spectra have been collected for all targets to date. The Fe-mineralogy of rock and soil targets at both landing sites reported to date has been exclusively extracted from 14.4 keV spectra [2-5]. The comparison of 6.4 keV and 14.4 keV spectra provides depth selective information about a sample, but interpretation is not always straightforward [8].

Fleischer, I.↗

Moessbauer/XRF MIMOS Instrumentation and Operation During the 2012 Analog Field Test on Mauna Kea Volcano, Hawaii

Field testing and scientific investigations were conducted on the Mauna Kea Volcano, Hawaii, as part of the 2012 Moon and Mars Analog Mission Activities (MMAMA). Measurements were conducted using both stand-alone and rover-mounted instruments to determine the geophysical and geochemical properties of the field site, as well as provide operational constraints and science considerations for future robotic and human missions [1]. Reported here are the results from the two MIMOS instruments deployed as part of this planetary analog field test.

Graff, Trevor G.↗