Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICRORADIOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A compact design of a temperature gradient furnace for synchrotron microradiography

A compact, convenient and economic design of a temperature gradient furnace for synchrotron microradiography is described. The thermal control of the furnace, in terms of cooling rate and temperature gradient, was achieved by programmable temperature controllers, and provided necessary thermal conditions for real time observations of dendritic solidification in real alloys. The experiments at the Advanced Photon Source (APS), Argonne National Laboratory (ANL) demonstrate that the design is well suited to the melting and solidification of alloys with liquidus temperatures up to intermediate ranges ({approx}650 C), such as aluminium alloys. Real time observations with this furnace of dendritic solidification in Al-25 wt% Cu alloy by synchrotron microradiography show interesting and promising results.

36 MATERIALS SCIENCE↗

Microradiography with Semiconductor Pixel Detectors

High resolution radiography (with X-rays, neutrons, heavy charged particles, ...) often exploited also in tomographic mode to provide 3D images stands as a powerful imaging technique for instant and nondestructive visualization of fine internal structure of objects. Novel types of semiconductor single particle counting pixel detectors offer many advantages for radiation imaging: high detection efficiency, energy discrimination or direct energy measurement, noiseless digital integration (counting), high frame rate and virtually unlimited dynamic range. This article shows the application and potential of pixel detectors (such as Medipix2 or TimePix) in different fields of radiation imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real Time Observation of Dendritic Solidification in Real Alloys by Synchrotron Microradiography

A third generation synchrotron x-ray source and advanced imaging facilities were used to study dendritic solidification in metallic alloys in real time. A digital camera and a video camera with different time and spatial resolution were tested to capture growing dendrites during solidification of Sn-13 wt%Bi and Al-25 wt%Cu alloys. The captured digital images show that the morphology of the dendrites can be resolved with satisfactory resolution and contrast. The trade-off between spatial resolution and time resolution was discussed. The effect of beam characteristics such as intensity, parallelism and coherency on both spatial and time resolution was analysed, and potential improvements with higher image quality with reduced exposure time were also discussed.

43 PARTICLE ACCELERATORS↗

Applications of synchrotron radiation to materials science: Diffraction imaging (topography) and microradiography

Synchrotron radiation sources are now available throughout the world. The use of hard X-ray radiation from these sources for materials science is described with emphasis on diffraction imaging for material characterization. With the availability of synchrotron radiation, real-time in situ measurements of dynamic microstructural phenomena have been started. This is a new area where traditional application of X-rays has been superseded. Examples are chosen from limited areas and are by no means exhaustive. The new emerging information will, no doubt, have great impact on materials science and engineering.

Kuriyama, Masao↗

Nondestructive evaluation of structural ceramics by photoacoustic microscopy

A photoacoustic microscopy (PAM) digital imaging system was developed and utilized to characterize silicon nitride material at the various stages of the ceramic fabrication process. Correlation studies revealed that photoacoustic microscopy detected failure initiating defects in substantially more specimens than microradiography and ultrasonic techniques. Photoacoustic microscopy detected 10 to 100 micron size surface and subsurface pores and inclusions, respectively, up to 80 microns below the interrogating surface in machined sintered silicon nitride. Microradiography detected 50 micron diameter fracture controlling pores and inclusions. Subsurface holes were detected up to a depth of 570 microns and 1.00 mm in sintered silicon nitride and silicon carbide, respectively. Seeded voids of 20 to 30 micron diameters at the surface and 50 microns below the interrogating surface were detected by photoacoustic microscopy and microradiography with 1 percent X-ray thickness sensitivity. Tight surface cracks of 96 micron length x 48 micron depth were detected by photoacoustic microscopy. PAM volatilized and removed material in the green state which resulted in linear shallow microcracks after sintering. This significantly limits the use of PAM as an in-process NDE technique.

Khandelwal, Pramod K.↗

Real-time visualization of particle evolution during reactive flux-assisted processing of aluminum melts

Here, a multi-modal, multi-scale correlative tomography investigation of Al-TiC metal matrix composites processed via flux-assisted reaction synthesis is reported. Synchrotron X-ray microradiography is utilized to visualize the reaction and particle evolution in real-time. Changes in particle diameter and areal number density suggest that the process is nucleation- rather than growth-dominated. At 950 °C, the bulk of the reaction takes place in a relatively short time span of less than 600 s. The microstructure is imaged at higher resolution in 2D (scanning electron microscopy) and 3D (synchrotron X-ray nanotomography), revealing the formation of carbide particles with a hexagonal platelet morphology. We propose that the morphology arises due to the incorporation of Si impurities during the experiment. It is expected that the correlative tomography workflow and analysis may guide future metal matrix composite (MMC) processing strategies.

36 MATERIALS SCIENCE↗

Visualization of membrane protein crystals in lipid cubic phase using X-ray imaging

A comparison of X-ray diffraction and radiographic techniques for the location and characterization of protein crystals is demonstrated on membrane protein crystals mounted within lipid cubic phase material. The focus in macromolecular crystallography is moving towards even more challenging target proteins that often crystallize on much smaller scales and are frequently mounted in opaque or highly refractive materials. It is therefore essential that X-ray beamline technology develops in parallel to accommodate such difficult samples. In this paper, the use of X-ray microradiography and microtomography is reported as a tool for crystal visualization, location and characterization on the macromolecular crystallography beamlines at the Diamond Light Source. The technique is particularly useful for microcrystals and for crystals mounted in opaque materials such as lipid cubic phase. X-ray diffraction raster scanning can be used in combination with radiography to allow informed decision-making at the beamline prior to diffraction data collection. It is demonstrated that the X-ray dose required for a full tomography measurement is similar to that for a diffraction grid-scan, but for sample location and shape estimation alone just a few radiographic projections may be required.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A compact and flexible induction furnace for in situ X-ray microradiograhy and computed microtomography at Elettra: design, characterization and first tests

A compact and versatile induction furnace for in situ high-resolution synchrotron and laboratory hard X-ray microradiography and computed microtomography is described. The furnace can operate from 773 to 1723 K. Its programmable controller enables the user to specify multiple heating and cooling ramp rates as well as variable dwell times at fixed temperatures allowing precise control of heating and cooling rates to within 5 K. The instrument can work under a controlled atmosphere. Thanks to the circular geometry of the induction coils, the heat is homogeneously distributed in the internal volume of the graphite cell ( ca . 150 mm 3 ) where the sample holder is located. The thermal gradient within the furnace is less than 5 K over a height of ca . 5 mm. This new furnace design is well suited to the study of melting and solidification processes in geomaterials, ceramics and several metallic alloys, allowing fast heating (tested up to 6.5 K s -1 ) and quenching (up to 21 K s -1 ) in order to freeze the sample microstructure and chemistry under high-temperature conditions. The sample can be held at high temperatures for several hours, which is essential to follow phenomena with relatively slow dynamics, such as crystallization processes in geomaterials. The utility of the furnace is demonstrated through a few examples of experimental applications performed at the Elettra synchrotron laboratory (Trieste, Italy).

Kudrna Prašek, Marko↗

Tensile fracture of unidirectional B-Al composite.

Fracture studies on unidirectional boron filament/aluminum matrix composite under axial tension were conducted using scanning electron microscopy, microradiography, and an acoustic emission technique. The combination of these analysis techniques has allowed the description and microstructural characterization of a new noncumulative fracture mode which involves filament break propagation. This fracture mode was found to severely limit the tensile strength of the composite, since the initiation of break propagation leads immediately to catastrophic failure at filament stress levels above a critical value. This critical filament stress was found to be 170,000 psi, and it appeared to be independent of filament diameter, number of filament layers, and the type of matrix alloy.

Steele, J. H.↗

Investigation of solidification in zero-gravity environment; M553 sphere forming experiment. Phase C: Evaluation of Skylab specimens

Results on specimen evaluation and discussion of solidification behavior in each case are reported in the following order: (1) specimen SL-1.6, (2) specimen SL-2.8, (3) specimen SL-2.4, (4) specimen SL-1.10 and (5) specimen SL-1.11. Comparison is made with ground-processed specimens of similar composition, whenever pertinent and meaningful. Among the nondestructive evaluation methods the measurement of sphericity was conducted by micrometric and shadowgraphic techniques. The intricate shape of specimens in some cases appeared difficult to define. In measuring the density, liquid penetration inside cavities that outcrop on the surface was avoided by sealing off these cavities. Among the destructive evaluation methods the use of the Quantimet 720 required particular attention, because of the small difference in contrast between second phases and micropores. With regard to microporosity microvoids in the core of some specimens were so fine that X-ray microradiography had to be used.

Kattamis, T. Z.↗

Evidence for arrested bone formation during spaceflight

Addressing the question of whether the bone formed in space is unusual, the morphology of bone made at the tibial diaphysis of rats before, during, and after spaceflight is studied. Evidence of arrest lines in the bone formed in space is reported suggesting that bone formation ceases along portions of the periosteum during spaceflight. Visualized by microradiography, the arrest lines are shown to be less mineralized than the surrounding bone matrix. When viewed by scanning electron microscopy, it is seen that bone fractures more readily at the site of an arrest line. These observations are seen as suggesting that arrest lines are a zone of weakness and that their formation may result in decreased bone strength in spite of normalization of bone formation after flight. The occurrence, location, and morphology of arrest lines are seen as suggesting that they are a visible result of the phenomenon of arrested bone formation.

Turner, R. T.↗

Quantitative 3-D imaging topogrammetry for telemedicine applications

The technology to reliably transmit high-resolution visual imagery over short to medium distances in real time has led to the serious considerations of the use of telemedicine, telepresence, and telerobotics in the delivery of health care. These concepts may involve, and evolve toward: consultation from remote expert teaching centers; diagnosis; triage; real-time remote advice to the surgeon; and real-time remote surgical instrument manipulation (telerobotics with virtual reality). Further extrapolation leads to teledesign and telereplication of spare surgical parts through quantitative teleimaging of 3-D surfaces tied to CAD/CAM devices and an artificially intelligent archival data base of 'normal' shapes. The ability to generate 'topogrames' or 3-D surface numerical tables of coordinate values capable of creating computer-generated virtual holographic-like displays, machine part replication, and statistical diagnostic shape assessment is critical to the progression of telemedicine. Any virtual reality simulation will remain in 'video-game' realm until realistic dimensional and spatial relational inputs from real measurements in vivo during surgeries are added to an ever-growing statistical data archive. The challenges of managing and interpreting this 3-D data base, which would include radiographic and surface quantitative data, are considerable. As technology drives toward dynamic and continuous 3-D surface measurements, presenting millions of X, Y, Z data points per second of flexing, stretching, moving human organs, the knowledge base and interpretive capabilities of 'brilliant robots' to work as a surgeon's tireless assistants becomes imaginable. The brilliant robot would 'see' what the surgeon sees--and more, for the robot could quantify its 3-D sensing and would 'see' in a wider spectral range than humans, and could zoom its 'eyes' from the macro world to long-distance microscopy. Unerring robot hands could rapidly perform machine-aided suturing with precision micro-sewing machines, splice neural connections with laser welds, micro-bore through constricted vessels, and computer combine ultrasound, microradiography, and 3-D mini-borescopes to quickly assess and trace vascular problems in situ. The spatial relationships between organs, robotic arms, and end-effector diagnostic, manipulative, and surgical instruments would be constantly monitored by the robot 'brain' using inputs from its multiple 3-D quantitative 'eyes' remote sensing, as well as by contact and proximity force measuring devices. Methods to create accurate and quantitative 3-D topograms at continuous video data rates are described.

Altschuler, Bruce R.↗

Counter Architectures for a Single Photon-Counting Pixel Detector such as Medipix3

Medipix3 is a single photon-counting pixel readout chip whose new front-end architecture aims to eliminate the spectral distortion produced by charge diffusion in highly segmented semiconductor detectors. The chip requires area and power-efficient reconfigurable digital counters and shift registers that can be integrated with other photon-processing analog and digital circuits within the 55 {mu}mx55 {mu}m pixel area. This work proposes a configurable-depth, programmable mode digital counter for use in Medipix3.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Digital Image Processing Methods for Portal Image Quality Improvement

The different processing methods which could increase the contrast (unsharp mask, histogram equalization, and deconvolution) and reduce noise (median filter) were analysed. An application which allows the importation of BeamView files (ACR-NEMA 2.0 format) and the application of the above mentioned methods were developed. The main objective was to obtain the most accurate comparison of Beamview images with Digitally Received Radiograms. The preliminary results of image processing methods are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Femtosecond-Laser-Driven Cluster-Based Plasma Source for High-Resolution Ionography

The intense isotropic source of multicharged ions, with energy above 300 keV, was produced by femtosecond Ti:Sa laser pulses irradiation (intensity of approx4x10{sup 17} W/cm{sup 2}) of the He and CO{sub 2} gases mixture expanded in supersonic jet. High contrast ionography images have been obtained for 2000 dpi metal mesh, 1 mum polypropylene and 100 nm Zr foils, as well as for different biological objects. Images were recorded on 1 mm thick CR-39 ion detector placed in contact with back surface of the imaged samples, at the distances 140-160 mm from the plasma source. The obtained spatial resolution of the image was approx600 nm. A 100 nm object thickness difference was resolved very well for both Zr and polymer foils. The multicharged ion energy for Carbon and Oxygen ions passing through the 1 mum polypropylene foil is estimated to give the energy of more than 300 keV. An almost equal number of ions were measured with total number of about 10{sup 8} per shot at a different direction from plasma source. Easy production of different sub-MeV ions in wide space angle, recognizes femtosecond-laser-driven-cluster-based plasma as a well-suited bright source for novel type of submicron ionography to image different media, including nanofoils, membranes, and other low-contrast objects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observer POD for radiographic testing

The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗