Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE 100-1000”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multi-Variable Model-Based Parameter Estimation Model for Antenna Radiation Pattern Prediction

A new procedure is presented to develop multi-variable model-based parameter estimation (MBPE) model to predict far field intensity of antenna. By performing MBPE model development procedure on a single variable at a time, the present method requires solution of smaller size matrices. The utility of the present method is demonstrated by determining far field intensity due to a dipole antenna over a frequency range of 100-1000 MHz and elevation angle range of 0-90 degrees.

Deshpande, Manohar D.↗

Nonlinear-mirror mode-locked 1052 nm Yb:CALGO laser

We report a diode-pumped nonlinear mirror mode-locked solid-state Yb:CALGO laser operating at 1052 nm. The nonlinear mirror consists of a BBO crystal and a dichroic mirror. Continuous-wave mode-locking with a 1.78 W average power at 116 MHz is obtained. The slope efficiency is 22.6%. The bandwidth of the mode-locked laser is 1.2 nm, Considering GVM of BBO, the pulse width is calculated to be 2.3 ps.

42 ENGINEERING↗

Simultaneous photonic generation of multiple chirp and unchirp microwave waveform with frequency multiplying capability for optical beam forming system

A photonic technique based on the Mach–Zehnder Modulator and the dual parallel Mach–Zehnder modulator is proposed for the simultaneous generation of multiple chirp and unchirp microwave waveform with frequency multiplying capability for efficient beam steering applications. There is provision to obtain a single chirp signal of a particular center frequency and chirp rate from a multiple chirp signal without any alternation in the experimental setup. In the proposed methodology, the PIN photodetector is used for the detection of 12 GHz unchirp microwave waveform showing the frequency doubling characteristics and the balance photodetector is used for the detection of multiple chirp signal with frequency components 6, 12, and 18 GHz. The same experimental setup is used to generate dual linear chirp microwave signal of 12 GHz center frequency. This can be achieved by adjusting the bias voltage of the phase modulator. Time bandwidth product and bandwidth of the signal are 18.33 and 410 MHz, respectively. This technique is tunable in frequency, but the generation of higher frequency microwave signals is limited by the speed and bandwidth of the Mach–Zehnder Modulator and photodetector. The novelty of our proposed scheme is that we are going to drive MZM by chirp RF signal to multiply the chirp rate in manifold. To the best of our knowledge the effect of chirp microwave signal on photonic highly steerable beam forming system has not yet been studied experimentally in past, which we are targeting under this paper. It is expected that the range of beam steering performance should be improved substantially as compared to previously reported results.

42 ENGINEERING↗

Representativeness and repeatability of microenvironmental personal and head exposures to radio-frequency electromagnetic fields

Highlights: • First time assessment of head exposure to RF-EMF in uncontrolled environments, in 15 microenvironments in Melbourne, Australia. • We show that our measurement protocol is repeatable over time. • We show that the paths selected in our protocol are representative for the larger areas in which they are defined. • Exposure to RF-EMF is higher in more dense urban areas than in less populated suburban areas in the outskirts of the city. The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r{sup 2} > 0.66 for two paths in the same area) and a high repeatability over time (r{sup 2} > 0.87 for repetitions of the same path). The median head exposure in the 900 MHz downlink band ranged between 0.06 V/m and 0.31 V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r{sup 2} < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89 V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05 V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

1.55-μm mode-locked quantum-dot lasers with 300 MHz frequency tuning range

Passive mode-locking of two-section quantum-dot mode-locked lasers grown by metalorganic vapor phase epitaxy on InP is reported. 1250-μm long lasers exhibit a wide tuning range of 300 MHz around the fundamental mode-locking frequency of 33.48 GHz. The frequency tuning is achieved by varying the reverse bias of the saturable absorber from 0 to −2.2 V and the gain section current from 90 to 280 mA. 3 dB optical spectra width of 6–7 nm leads to ex-facet optical pulses with full-width half-maximum down to 3.7 ps. Single-section quantum-dot mode-locked lasers show 0.8 ps broad optical pulses after external fiber-based compression. Injection current tuning from 70 to 300 mA leads to 30 MHz frequency tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Instabilities in a capacitively coupled oxygen plasma

Periodic fluctuations in the frequency range from 0.3 to 3 kHz were experimentally investigated in capacitively coupled radio frequency (13.56 MHz) oxygen plasma. The Gaussian beam microwave interferometry directly provides the line integrated electron density fluctuations. A system of two Langmuir probes measured the floating potential spatially (axial, radial) and temporally resolved. Hence, the floating potential fluctuation development is mapped within the discharge volume and provides a kind of discharge breathing and no wave propagation. Finally, it was measured the optical emission pattern of atomic oxygen during the fluctuation as well as the RF phase resolved optical emission intensity at selected phase position of the fluctuation by an intensified charge-coupled device camera. The deduced excitation rate pattern reveals the RF sheath dynamics and electron heating mechanisms, which is changing between low and high electronegativity during a fluctuation cycle. A perturbation calculation was taken into account using a global model with 15 elementary collision processes in the balance equations for the charged plasma species (O{sub 2}{sup +}, e, O{sup −}, O{sub 2}{sup −}) and a harmonic perturbation. The calculated frequencies agree with the experimentally observed frequencies. Whereby, the electron attachment/detachment processes are important for the generation of this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface acoustic wave regulated single photon emission from a coupled quantum dot–nanocavity system

A coupled quantum dot–nanocavity system in the weak coupling regime of cavity-quantumelectrodynamics is dynamically tuned in and out of resonance by the coherent elastic field of a f{sub SAW} ≃ 800 MHz surface acoustic wave. When the system is brought to resonance by the sound wave, light-matter interaction is strongly increased by the Purcell effect. This leads to a precisely timed single photon emission as confirmed by the second order photon correlation function, g{sup (2)}. All relevant frequencies of our experiment are faithfully identified in the Fourier transform of g{sup (2)}, demonstrating high fidelity regulation of the stream of single photons emitted by the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detector-device-independent quantum key distribution: Security analysis and fast implementation

One of the most pressing issues in quantum key distribution (QKD) is the problem of detector side-channel attacks. To overcome this problem, researchers proposed an elegant “time-reversal” QKD protocol called measurement-device-independent QKD (MDI-QKD), which is based on time-reversed entanglement swapping. However, MDI-QKD is more challenging to implement than standard point-to-point QKD. Recently, an intermediary QKD protocol called detector-device-independent QKD (DDI-QKD) has been proposed to overcome the drawbacks of MDI-QKD, with the hope that it would eventually lead to a more efficient detector side-channel-free QKD system. Here, we analyze the security of DDI-QKD and elucidate its security assumptions. We find that DDI-QKD is not equivalent to MDI-QKD, but its security can be demonstrated with reasonable assumptions. On the more practical side, we consider the feasibility of DDI-QKD and present a fast experimental demonstration (clocked at 625 MHz), capable of secret key exchange up to more than 90 km.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A collimated neutron detector for RFP plasmas in MST

The neutron emissivity profile in the Madison Symmetric Torus is being reconstructed through the use of a collimated neutron detector. A scintillator-photomultiplier tube (PMT) system is employed to detect the fusion neutrons with the plasma viewing volume defined by a 55 cm deep, 5 cm diameter aperture. Effective detection of neutrons from the viewing volume is achieved through neutron moderation using 1300 lbs of high density polyethylene shielding, which modeling predicts attenuates the penetrating flux by a factor of 10{sup 4} or more. A broad spectrum of gamma radiation is also present due to the unconfined fusion proton bombardment of the thick aluminum vacuum vessel. A 15 cm cylindrical liquid scintillator of 3.8 cm diameter is used to further increase directional sensitivity. A fast (5 ns rise time) preamplifier and digitization at 500 MHz prevent pulse pile-up even at high count rates (∼10{sup 4}/s). The entire neutron camera system is situated on an adjustable inclining base which provides the differing plasma viewing volumes necessary for reconstruction of the neutron emissivity profile. This profile, directly related to the fast-ion population, allows for an investigation of the critical fast-ion pressure gradient required to destabilize a neutral beam driven Alfvénic mode which has been shown to transport fast ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meta-metallic coils and resonators: Methods for high Q-value resonant geometries

A novel method of decreasing ohmic losses and increasing Q-value in metallic resonators at high frequencies is presented. The method overcomes the skin-depth limitation of rf current flow cross section. The method uses layers of conductive foil of thickness less than a skin depth and capacitive gaps between layers. The capacitive gaps can substantially equalize the rf current flowing in each layer, resulting in a total cross-sectional dimension for rf current flow many times larger than a skin depth. Analytic theory and finite-element simulations indicate that, for a variety of structures, the Q-value enhancement over a single thick conductor approaches the ratio of total conductor thickness to skin depth if the total number of layers is greater than one-third the square of the ratio of total conductor thickness to skin depth. The layer number requirement is due to counter-currents in each foil layer caused by the surrounding rf magnetic fields. We call structures that exhibit this type of Q-enhancement “meta-metallic.” In addition, end effects due to rf magnetic fields wrapping around the ends of the foils can substantially reduce the Q-value for some classes of structures. Foil structures with Q-values that are substantially influenced by such end effects are discussed as are five classes of structures that are not. We focus particularly on 400 MHz, which is the resonant frequency of protons at 9.4 T. Simulations at 400 MHz are shown with comparison to measurements on fabricated structures. The methods and geometries described here are general for magnetic resonance and can be used at frequencies much higher than 400 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the effect of loop inductance on the RF transmission line to cavity coupling coefficient

Coupling of RF power is an important aspect in the design and development of RF accelerating structures. RF power coupling employing coupler loops has the advantage of tunability of β, the transmission line to cavity coupling coefficient. Analytical expressions available in literature for determination of size of the coupler loop using Faraday’s law of induction show reasonably good agreement with experimentally measured values of β below critical coupling (β ≤ 1) but show large deviation with experimentally measured values and predictions by simulations for higher values of β. In actual accelerator application, many RF cavities need to be over-coupled with β > 1 for reasons of beam loading compensation, reduction of cavity filling time, etc. This paper discusses a modified analytical formulation by including the effect of loop inductance in the determination of loop size for any desired coupling coefficient. The analytical formulation shows good agreement with 3D simulations and with experimentally measured values. It has been successfully qualified by the design and development of power coupler loops for two 476 MHz pre-buncher RF cavities, which have successfully been conditioned at rated power levels using these coupler loops.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A versatile radio-frequency source for cold atom experiments

A radio-frequency (RF) source designed for cold atom experiments is presented. The source uses AD9858, a direct digital synthesizer, to generate the sine wave directly, up to 400 MHz, with sub-Hz resolution. An amplitude control circuit consisting of wideband variable gain amplifier and high speed digital to analog converter is integrated into the source, capable of 70 dB off isolation and 4 ns on-off keying. A field programmable gate array is used to implement a versatile frequency and amplitude co-sweep logic. Owing to modular design, the RF sources have been used on many cold atom experiments to generate various complicated RF sequences, enriching the operation schemes of cold atoms, which cannot be done by standard RF source instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring local heating around an interventional MRI antenna with RF radiometry

Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or the extra space needed to accommodate alternative thermal transducers. A RF radiometer could be integrated in a MRI scanner to permit “self-monitoring” for assuring device safety and/or monitoring delivery of thermal therapy.

60 APPLIED LIFE SCIENCES↗

Nanocell with a pressure-controlled Rb atomic vapor column thickness: Critical influence of the thickness on optical processes

A new device is designed: it consists of a nanocell (NC) filled with Rb atom vapors and placed in a vacuum chamber. When the pressure in the chamber changes in the range 0–1 atm, the NC thickness is smoothly varied in the range L = 140–1700 nm, which is caused by the pressure-induced deformation of thin garnet windows in the chamber. The pressure dependence has excellent reproducibility even after many hundreds of cycles of letting in of air and its complete pumping out from the chamber. The accuracy of setting required thickness L is much better than in the wedge-gap NCs to be moved mechanically that were used earlier. The processes of Faraday rotation (FR) of a polarization plane, resonance absorption, and fluorescence are studied using the D{sub 1}-line narrow-band continuous laser radiation when the thickness changes from L = λ/2 (398 nm) to L = 2λ (1590 nm) at a step λ/2. The FR signal is shown to be maximal at L = λ/2 and 3λ/2 and to have the minimum spectral width (≈60 MHz). At L = λ and 2λ, the FR signal is minimal and has the maximum spectral width (≈200 MHz). The resonance absorption demonstrates the same oscillating behavior; however, the effect in the case of FR is much more pronounced. The oscillating effect is absent for resonance fluorescence: its spectral width and amplitude increase monotonically with L. The detected effects are explained and possible applications are noted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

J1216+0709: a radio galaxy with three episodes of AGN jet activity

We report the discovery of a “triple-double radio galaxy,” J1216+0709, detected in deep low-frequency Giant Metrewave Radio Telescope (GMRT) observations. J1216+0709 is only the third radio galaxy, after B0925+420 and Speca, with three pairs of lobes resulting from three different episodes of active galactic nucleus (AGN) jet activity. The 610 MHz GMRT image clearly displays an inner pair of lobes, a nearly coaxial middle pair of lobes, and a pair of outer lobes that is bent with respect to the axis of the inner pair of lobes. The total end-to-end projected sizes of the inner, middle, and outer lobes are 40″ (∼95 kpc), 1.′65 (∼235 kpc), and 5.′7 (∼814 kpc), respectively. Unlike the outer pair of lobes, both the inner and middle pairs of lobes exhibit asymmetries in arm lengths and flux densities, but in the opposite sense, i.e., the eastern sides are farther and also brighter than the western sides, thus, suggesting the possibility of the jet being intrinsically asymmetric rather than due to a relativistic beaming effect. The host galaxy is a bright elliptical (m {sub r} ∼ 16.56) with M {sub SMBH} ∼ 3.9 × 10{sup 9} M {sub ⊙} and a star formation rate of ∼4.66{sub −1.61}{sup +4.65} M {sub ⊙} yr{sup −1}. The host galaxy resides in a small group of three galaxies (m {sub r} ≤ 17.77) and is possibly going through an interaction with faint dwarf galaxies in the neighborhood, which may have triggered the recent episodes of AGN activity.

79 ASTRONOMY AND ASTROPHYSICS↗

GMRT Low-frequency Imaging of an Extended Sample of X-shaped Radio Galaxies

We present a low-frequency imaging study of an extended sample of X-shaped radio sources using the Giant Metrewave Radio Telescope (GMRT) at two frequencies (610 and 240 MHz). The sources were drawn from a Very Large Array Radio Images of the Sky at Twenty-Centimeters (FIRST) selected sample and extend an initial GMRT study at the same frequencies of 12 X-shaped radio galaxies predominantly from the 3CR catalog (Lal and Rao 2007). Both the intensity maps and spectral index maps of the 16 newly observed sources are presented. With the combined sample of 28 X-shaped radio sources, we found no systematic differences in the spectral properties of the higher surface brightness, active lobes versus the lower surface brightness, or off-axis emission. The properties of the combined sample are discussed, including the possible role of a twin active galactic nuclei model in the formation of such objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Radar Detectability Studies of Slow and Small Zodiacal Dust Cloud Particles. III. The Role of Sodium and the Head Echo Size on the Probability of Detection

We present a path forward on a long-standing issue concerning the flux of small and slow meteoroids, which are believed to be the dominant portion of the incoming meteoric mass flux into the Earth’s atmosphere. Such a flux, which is predicted by dynamical dust models of the Zodiacal Cloud, is not evident in ground-based radar observations. For decades this was attributed to the fact that the radars used for meteor observations lack the sensitivity to detect this population, due to the small amount of ionization produced by slow-velocity meteors. Such a hypothesis has been challenged by the introduction of meteor head echo (HE) observations with High Power and Large Aperture radars, in particular the Arecibo 430 MHz radar. Janches et al. developed a probabilistic approach to estimate the detectability of meteors by these radars and initially showed that, with the current knowledge of ablation and ionization, such particles should dominate the detected rates by one to two orders of magnitude compared to the actual observations. In this paper, we include results in our model from recently published laboratory measurements, which showed that (1) the ablation of Na is less intense covering a wider altitude range; and (2) the ionization probability, β{sub ip}, for Na atoms in the air is up to two orders of magnitude smaller for low speeds than originally believed. By applying these results and using a somewhat smaller size of the HE radar target we offer a solution that reconciles these observations with model predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-frequency Scatter Broadening Evolution of Pulsars. I

We present multi-wavelength scatter broadening observations of 47 pulsars made with the Giant Metre-wave Radio Telescope (GMRT), Ooty Radio Telescope (ORT), and Long Wavelength Array (LWA). The GMRT observations were made in the phased array mode at 148, 234, and 610 MHz and the ORT observations at 327 MHz. The LWA data sets were obtained from the LWA pulsar data archive. The broadening of each pulsar as a function of observing frequency provides the frequency scaling index, α. The estimations of α have been obtained for 39 pulsars and include entirely new estimates for 31 pulsars. This study increases the total sample of pulsars available with α estimates by ∼50%. The overall distribution of α with the dispersion measure (DM) of the pulsar shows interesting variations, which are consistent with earlier studies. However, for a given value of DM, a range of α values are observed, indicating the characteristic turbulence along each line of sight. For each pulsar, the estimated level of turbulence, C{sub n{sub e}{sup 2}}, has also been compared with α and DM. Additionally, we compare the distribution of α with the theoretically predicted model to infer the general characteristics of the ionized interstellar medium. Nearly 65% of the pulsars show a flatter index (i.e., α<4.4) than that expected from the Kolmogorov turbulence model. Moreover, the group of pulsars with flatter indices is typically associated with an enhanced value of C{sub n{sub e}{sup 2}} compared to those with steeper indices.

79 ASTRONOMY AND ASTROPHYSICS↗