Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2020)

This report documents the operations and testing that was performed at the Mechanisms Engineering Test Loop (METL) during FY2020. The METL facility had a very successful second year of operations having logged over 730 days (as of September 19, 2020) of operations with molten sodium either flowing or static. The METL piping and vessel system was filled with sodium on September 19, 2018 after a successful transfer of sodium from fifteen 55-gallon drums. FY2020 saw the successful reconditioning and insertion of the Gear Test Assembly (GTA) for its second round of testing, the full use of the 18-inch Flexi-Cask system, the second extraction of the GTA from METL, and the removal of sodium from the GTA test article by the carbonation process followed by an alcohol wash. In addition, METL is being prepared to support a second larger experiment, a thermal hydraulic experiment, called Thermal Hydraulic Experimental Test Article (THETA).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2021)

This report documents the operations and testing that was performed at the Mechanisms Engineering Test Loop (METL) during FY2021. The METL facility had a very successful third year of operations having logged about 944 days of operations with molten sodium either in a flowing or static condition. Operations were paused in April 20, 2021 to accommodate the refurbishing of building 308’s alkali metal passivation booth and scrubber (AMPB&S). METL is being prepared to support a second larger experiment, the Thermal Hydraulic Experimental Test Article (THETA) and expects to resume the Gear Test Assembly (GTA) testing. The technology development team is also developing two additional experiments, a gripper test article and a flow sensor test article that are expected to go into METL in late FY22 or early FY23.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanisms Engineering Test Loop (METL) Experimenter's Guide

The Mechanisms Engineering Test Loop (METL) was built to streamline and accelerate the in-sodium testing of systems and components under conditions that simulate a sodium-cooled fast reactor pool environment. The METL team at Argonne National Laboratory (ANL) can assist experimenters in achieving their technical goals by providing liquid-metal expertise and access to infrastructure required for most alkali metal related research. This document offers a brief overview of METL and provides a basic design guide for researchers interested in conducting research at the facility. Additional information regarding the history and operations of METL can be found in §6.1. Furthermore, high resolution images found in this document as well as CAD files of aforementioned vessels can be provided upon request.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2022)

This report documents the operations, testing, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) during FY2022. The METL facility had a very successful fourth year of operations and went through some new experiences such as taking the facility from its frozen state in October 2021 and thawing the facility and also recovering from an oxide plug in one of the cold trap lines. After the facility was fully thawed, the METL staff maintained the facility in a continuous molten state – either flowing sodium or a static flow condition. METL facility continued supporting the Gear Test Assembly (GTA) testing and hosted its first 28” test vessel experiment, called the Thermal Hydraulic Experimental Test Article (THETA) which was inserted into Test Vessel 4. Work to accommodate two additional experiments, a gripper test article (GrTA) and a flow sensor test article (F-STAr) continued as they are expected to make their debut in FY2023. In addition, the steam piping for the B308 scrubber unit was replaced with stainless steel piping and controls and new parts for the scrubber were purchased – such as a new pump, new storage tank, and new blower and motor. These components will ultimately replace the existing scrubber components when those 1970’s era require replacement.

42 ENGINEERING↗

Advanced Monitoring and Control in the ANL METL Facility Using an Engineering Digital Twin

The potential benefits of using an engineering digital twin to achieve greater autonomy for monitoring and control functions in advanced reactors was investigated for the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The METL sodium purification system served as a representative system as it requires significant human in-the-loop interaction to accomplish its design function. The objective was to demonstrate how real-time operation could be automated while preserving oversight of the operator for ensuring that the system design functions are met. A digital twin model of the purification system was developed for both the cold trap purification loop and plugging meter diagnostic loop using information from the METL piping and instrumentation diagram (P&ID). Automated monitoring and diagnosis of component degradation in the METL facility was demonstrated in tests using the PRO-AID health monitoring software with the digital twin model incorporated in the library of components. Component failures were introduced and were successfully diagnosed in real time. These tests serve to demonstrate an advanced monitoring capability able to differentiate sensor degradation from component degradation, to generate a rank ordering of probabilities of different failure mechanisms that serves to circumvent the false alarm problem with current anomaly detection methods, and how facility monitoring can be transformed from anomaly detection to identification of a specific fault. Automated control of the purification system was demonstrated through simulations that exercised a model predictive controller designed using the digital twin model. Results of these simulations compared favorably with experimental data showing very good reference tracking response with negligible overshoot. In conclusion, these pilot tests and simulations successfully demonstrated the use of a digital twin for improved automation of monitoring and control. It was shown how the digital twin enables switching between control modes from cold trap operation where impurities are removed to plugging meter operation where impurity concentrations are measured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanisms Engineering Test Loop (METL) Experimenter's Guide - Revision 2

The Mechanisms Engineering Test Loop (METL) was built to streamline and accelerate the in-sodium testing of systems and components under conditions that simulate a sodium-cooled fast reactor pool environment. The METL team at Argonne National Laboratory (ANL) can assist experimenters in achieving their technical goals by providing liquid-metal expertise and access to infrastructure required for most alkali metal related research. This document offers a brief overview of METL and provides a basic design guide for researchers interested in conducting research at the facility. Additional information regarding the history and operations of METL can be found in §6.1. Furthermore, high resolution images found in this document as well as CAD files of aforementioned vessels can be provided upon request.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanisms Engineering Test Loop (METL) Operations, Maintenance, and Testing - FY2025

This report documents the operations, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) and its supporting infrastructure during FY2024. The METL facility had a very successful seventh year of operations while supporting the testing of multiple test article experiments in the facility. The METL facility continued supporting the Gear Test Assembly (GTA) testing and the Thermal Hydraulic Experimental Test Article (THETA) with the full testing with both the primary and secondary systems. Work to accommodate two additional experiments, a flow sensor test article (F-STAr) gripper test and a fuel handling gripper test article (GrTA) continued as they are expected to undergo testing in METL in FY2025. In addition, a new 18” test article, the Sample Testing Basket (STB) was used a few times to provide screening tests for sodium service materials. A fifth test vessel was installed in the location of Test Vessel 6, and a wet vapor nitrogen sodium processing system was developed and initially tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deploying Extended Reality (XR) for Digital Operations and Maintenance (O&M) at the Mechanisms Engineering Test Loop (METL)

This report documents the preliminary efforts to digitize operation and maintenance (O&M) activities for the Mechanisms Engineering Test Loop (METL). METL became operational in September 2018 with the mission to provide an ecosystem for Advanced Reactor Development (ARD). METLs flagship facility’s primary purpose is conducting small to intermediate scale tests for Sodium Fast Reactors (SFR). Its resemblance to commercial SFR’s intermediate heat transport system, prototypic operating conditions, and industrial construction practices/materials provides the overarching benefit of establishing a proving ground for emerging operations and maintenance (O&M) activities such as incorporating Extended Reality (XR) applications throughout the program lifecycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Temperature Sodium System Structural Health Monitoring (SHM) Technologies at the Mechanisms Engineering Test Loop (METL)

This report documents the deployment of non-destructive testing (NDT) technologies at the Mechanisms Engineering Test Loop (METL). METL became operational in September 2018 with the mission to provide an ecosystem for Advanced Reactor Development (ARD). METLs flagship facility’s primary purpose is conducting small to intermediate scale tests for Sodium Fast Reactors (SFR). Its resemblance to a commercial SFR’s intermediate heat transport system, prototypic operating conditions, and industrial construction practices/materials provides the overarching benefit of establishing a proving ground for devices of all technology readiness levels as well as commercial off-the-shelf equipment yet to be demonstrated on a sodium system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of ASI-developed Sensors for Inclusion in METL Testing

The Advanced Sensors and Instrumentation (ASI) program facilitates the development of new sensors for both conventional and advanced reactors. Advanced reactor concepts utilize coolants other than light water, such as molten salts, liquid sodium, and high-temperature helium. Qualification of sensors developed for these advanced reactors is complicated by the relatively small number of facilities available that can provide relevant testing conditions (e.g., temperature, flow, and coolant chemistry). This report identifies sensors that were developed under the ASI program and may be tested in one available testbed: the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL), a non-nuclear liquid sodium flow facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanisms Engineering Test Loop - Flexicask Design and Testing Report

This report documents the design development and testing of the Flexicask system for the Mechanisms Engineering Test Loop (METL). Currently, METL has completed Phase I construction and has been operating for over a year. The Flexicask system (Figure 1) was designed to allow for the removal and insertion of test articles into a METL test vessel while maintaining an acceptable inert atmosphere to minimize contamination of the METL sodium. This report discusses the design development of the Flexicask system, the commissioning and testing of the system, and the initial use of the Flexicask system to remove the Gear Test Assembly (GTA) from the METL Test Vessel 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of GTA Gear Inspection after Testing in Sodium

The Mechanisms Engineering Test Loop (METL) is an intermediate-scale liquid metal experimental facility that provides purified reactor-grade (R-grade) sodium to various experimental test vessels. In these test vessels, components that are required to operate in an advanced fast reactor can be tested in a prototypical sodium environment. Experiments conducted in METL significantly assist in the development and maturation of systems and components for advanced reactors. The METL facility consists of multiple test segments including: a purification and diagnostic loop (cold trap was designed after EBR-II), two 18” diameter test vessels with 150 L capacities capable of operating in static or dynamic flow at 538°C, two 28” diameter test vessels with 644 L capacities capable of operating in static or dynamic flow at 650°C, a 3,180 L dump tank with 21 instrumentation ports, and the infrastructure to expand capacity in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Status Update for the Bearing Test Article Design Development – FY2025

Argonne National Laboratory’s (ANL) Mechanism Engineering Test Loop (METL) team has completed the design of a new Bearing Test Article (BTA) to test mechanical bearings for sodium fast reactor (SFR) mechanism applications. Recognition of the need for further bearing testing arose due to failure of rolling element bearings during testing of components for in-vessel fuel handling machines (FHMs) conducted at ANL in the METL facility. While the initial concept of the BTA arose from a need for bearing testing for FHM applications, the BTA design is configurable to test bearings of various sizes, types, and materials submerged in liquid sodium. Requirements for loading, shaft speed, temperature, and bearing size range were chosen based on requirements for SFR fuel handling. Modular components in the test bearing housings and shaft sleeves allow the design to accommodate a wide range of bearing sizes without modification to the larger assembly. Loading will be applied with screw jacks on the air side of the test article that will be adjusted to apply radial, thrust, or combined loading conditions. Applied force will be measured by load cells in-line with the loading mechanisms. In FY25 we have completed the design of the test article that will be fabricated and undergo testing at the METL facility. Drawing packages for the fabrication of the test article have been drafted and are being reviewed to add part tolerances and we have started ordering off-the-shelf components. The report will summarize the development of the Bearing Test Article design starting with an overview of the entire test article, then a more detailed examination of the bearing test section, loading mechanisms, test article ports and seals, and support structures, including analysis that went into significant design choices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING↗