Rapid Automated Annotation and Analysis of N-Glycan Mass Spectrometry Imaging Data Sets Using NGlycDB in METASPACE

Imaging N-glycan spatial distribution in tissues using mass spectrometry imaging (MSI) is emerging as a promising tool in biological and clinical applications. However, there is currently no high throughput tool for visualization and molecular annotation of N-glycans in MSI data, which significantly slows down data processing and hampers the applicability of this approach. In this work, we present how METASPACE, an open-source cloud engine for molecular annotation of MSI data, can be used to automatically annotate, visualize, analyze, and interpret high-resolution mass spectrometry-based spatial N-glycomics data. METASPACE is an emerging tool in spatial metabolomics, but the lack of compatible glycan databases has limited its application for comprehensive N-glycan annotations from MSI datasets. We created NGlycDB, a public database of N-glycans, by adapting available glycan databases. We demonstrate the applicability of NGlycDB in METASPACE by analyzing MALDI-MSI data from formalin-fixed paraffin-embedded (FFPE) human kidney and mouse lung tissue sections. We added NGlycDB to METASPACE for public use, thus facilitating applications of MSI in glycobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Step-by-Step Protocol from METASPACE to Biological Interpretation

Mass spectrometry imaging (MSI) represents an exceptional tool for exploring complex biological systems spatially at the molecular level. However, due to its multidimensional nature and large-scale data output, it presents considerable challenges when it comes to extracting meaningful biological insights. Recent advancements, such as the METASPACE platform, have enabled researchers to efficiently process, annotate, and interpret MSI datasets by leveraging machine learning and cloud-based infrastructure. In this tutorial, we present a detailed and user-friendly R-pipeline designed to help METASPACE users navigate untargeted metabolomic annotations and transform them into practical insights about their biological systems. By combining METASPACE annotations with rapid R-based screening, this workflow not only streamlined the analytical process but also enhanced the understanding of spatial molecular distribution, especially for complex systems. Here, this easy-to-follow approach has the potential for applications in diagnostics, drug discovery, environmental and ecological processes, and more. We envision this pipeline to be particularly useful for newcomers to the field of MSI and

Moreno Pedraza, Abigail↗

Untargeted Spatial Metabolomics and Spatial Proteomics on the Same Tissue Section

An increasing number of spatial multiomic workflows have been recently developed. Some of these approaches have leveraged initial mass spectrometry imaging (MSI)-based spatial metabolomics to inform region of interest (ROI) selection for downstream spatial proteomics. However, these workflows have been limited by varied substrate requirements between modalities or have required analyzing serial sections (i.e., one section per modality). To mitigate these issues, we present a novel multiomic workflow that uses desorption electrospray ionization (DESI)-MSI to identify representative spatial metabolite patterns on-tissue prior to spatial proteomic analyses on the same tissue section. Further, this workflow is demonstrated here with a model mammalian tissue (coronal rat brain section) mounted on a polyethylene naphthalate-membrane slide. Initial DESI-MSI resulted in 160 annotations (SwissLipids) within to the METASPACE platform (≤20% false discovery rate). A segmentation map from the annotated ion images informed downstream ROI selection for spatial proteomics characterization from the same sample. The unspecific substrate requirements and minimal sample disruption inherent to DESI-MSI allowed for an optimized, downstream spatial proteomics assay, resulting in 3888 ± 240 to 4717 ± 48 proteins being confidently directed per ROI (200 µm x 200 µm). Finally, we demonstrate the integration of multiomic information, where we found ceramide localization to be correlated with SMPD3 abundance (ceramide synthesis protein), and we also utilized protein abundance to resolve metabolite isomeric ambiguity. Overall, the integration of DESI-MSI into the multiomic workflow allows for complementary spatial and molecular-level information to be achieved from optimized implementations of each MS assay inherent to the workflow itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Storage Conditions of Human Kidney Tissue Sections Affect Spatial Lipidomics Analysis Reproducibility

Lipids often are labile, unstable, and tend to degrade overtime, so it is of the upmost importance to study these molecules in their most native state. In this study, we sought to understand the optimal storage conditions for spatial lipidomic analysis of human kidney tissue sections. Specifically, we evaluated human kidney tissue sections on several different days throughout the span of a week using our established protocol for elucidating lipids using high mass resolution matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). We studied kidney tissue sections stored under five different conditions: open stored at –80 °C, vacuumed sealed and stored at –80 °C, with matrix preapplied before storage at –80 °C, under a nitrogen atmosphere and stored at –80 °C, and at room temperature in a desiccator. Results were compared to data obtained from kidney tissue sections that were prepared and analyzed immediately after cryosectioning. Data was processed using METASPACE. After a week of storage, the sections stored at room temperature showed the largest amount of lipid degradation, while sections stored under nitrogen and at –80 °C retained the greatest number of overlapping annotations in relation to freshly cut tissue. Overall, we found that molecular degradation of the tissue sections was unavoidable over time, regardless of storage conditions, but storing tissue sections in an inert gas at low temperatures can curtail molecular degradation within tissue sections.

60 APPLIED LIFE SCIENCES↗

Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging

Automated spraying devices have become ubiquitous in laboratories employing matrixassisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time consuming and can lead to overall non-optimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirtytwo combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal de-localization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other MALDI-MSI applications, tissue types, and matrix application approaches.

60 APPLIED LIFE SCIENCES↗