Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASURING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Final design and first use of in-situ measuring apparatus for measurement of permanent magnet resiliency in CEBAF’s radiation environment

In this work we outline the final design and initial measurement lessons for the holders and measuring apparatus of the permanent magnet resiliency experiment which is a part of the FFA@CEBAF proposed upgrade. The experiment will expose permanent magnets to the radiation environment of CEBAF. Due to safety regulations we need to measure the magnets in the tunnel without bringing them out, so we designed a mobile measuring system as well as a series of protocols to allow us to speedily measure these samples even under adverse conditions. We also designed our system to be capable of taking measurements even with component failures.

Accelerator Physics↗

WTP Waste Feed Qualification: Hydrogen Generation Rate Measurement Apparatus Testing Report

The generation rate of hydrogen gas in the Hanford tank waste will be measured during the qualification of the staged tank waste for processing in the Hanford Tank Waste Treatment and Immobilization Plant. Based on a review of past practices in measurement of the hydrogen generation, an apparatus to perform this measurement has been designed and tested for use during waste feed qualification. The hydrogen generation rate measurement apparatus (HGRMA) described in this document utilized a 100 milliliter sample in a continuously-purged, continuously-stirred vessel, with measurement of hydrogen concentration in the vent gas. The vessel and lid had a combined 220 milliliters of headspace. The vent gas system included a small condenser to prevent excessive evaporative losses from the sample during the test, as well as a demister and filter to prevent particle migration from the sample to the gas chromatography system. The gas chromatograph was an on line automated instrument with a large-volume sample-injection system to allow measurement of very low hydrogen concentrations. This instrument automatically sampled the vent gas from the hydrogen generation rate measurement apparatus every five minutes and performed data regression in real time. The fabrication of the hydrogen generation rate measurement apparatus was in accordance with twenty three (23) design requirements documented in the conceptual design package, as well as seven (7) required developmental activities documented in the task plan associated with this work scope. The HGRMA was initially tested for proof of concept with physical simulants, and a remote demonstration of the system was performed in the Savannah River National Laboratory Shielded Cells Mockup Facility. Final verification testing was performed using non-radioactive simulants of the Hanford tank waste. Three different simulants were tested to bound the expected rheological properties expected during waste feed qualification testing. These simulants were tested at different temperatures using purge gas spiked with varying amounts of hydrogen to provide verification that the system could accurately measure the hydrogen in the vent gas at steady state.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Pulse measurement apparatus and method

An embodiment of the invention is directed to a pulse measuring system that measures a characteristic of an input pulse under test, particularly the pulse shape of a single-shot, nano-second duration, high shape-contrast optical or electrical pulse. An exemplary system includes a multi-stage, passive pulse replicator, wherein each successive stage introduces a fixed time delay to the input pulse under test, a repetitively-gated electronic sampling apparatus that acquires the pulse train including an entire waveform of each replica pulse, a processor that temporally aligns the replicated pulses, and an averager that temporally averages the replicated pulses to generate the pulse shape of the pulse under test. An embodiment of the invention is directed to a method for measuring an optical or an electrical pulse shape. The method includes the steps of passively replicating the pulse under test with a known time delay, temporally stacking the pulses, and temporally averaging the stacked pulses. An embodiment of the invention is directed to a method for increasing the dynamic range of a pulse measurement by a repetitively-gated electronic sampling device having a rated dynamic range capability, beyond the rated dynamic range of the sampling device; e.g., enhancing the dynamic range of an oscilloscope. The embodied technique can improve the SNR from about 300:1 to 1000:1. A dynamic range enhancement of four to seven bits may be achieved.

47 OTHER INSTRUMENTATION↗

Energy storage cell impedance measuring apparatus, methods and related systems

Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

25 ENERGY STORAGE↗

Terahertz and Optical Measurement Apparatus for the Fermilab ASTA Injector

ASTA is a facility at Fermilab that, once completed, will consist of a photoinjector with two superconducting capture cavities, at least one superconducting ILC-style cryomodule, and a small ring for studying non-linear, integrable beam optics. This paper discusses the layout for the optical transport system that will provide THz radiation to a Martin-Puplett interferometer for bunch length measurements as well as optical radiation to an externally located streak camera, also for bunch length measurements. It will be able to accept radiation from two synchrotron radiation ports in the bunch compressor, a diffraction/transition radiation screen downstream of the compressor, and a transition radiation screen after the spectrometer magnet for measurements of energy-time correlations.

Thurman-Keup, R.↗

Eddy current thickness measurement apparatus

A sheet of a material is disposed in a melt of the material. The sheet is formed using a cooling plate in one instance. An exciting coil and sensing coil are positioned downstream of the cooling plate. The exciting coil and sensing coil use eddy currents to determine a thickness of the solid sheet on top of the melt.

14 SOLAR ENERGY↗

Thermal measurement apparatus and methods for anisotropic thermal materials

A system for characterizing thermal properties of thermally anisotropic heterogeneous samples includes a heating element, a first temperature sensing device, a second temperature sensing device, and a computing system. The heating element is positioned at a first location within a sample and heats the sample. The first temperature sensing device outputs data indicative of temperatures of the first location to the computing device. The second temperature sensing device outputs data indicative of temperatures of the second location to the computing device. The computing device computes a thermal conductivity of the sample based upon the temperatures of the first location. The computing device further outputs an indication of a portion of the sample to which the thermal conductivity pertains based upon the second temperatures.

Reyes, Karla Rosa↗

Thermal measurement apparatus and methods for anisotropic thermal materials

A system for characterizing thermal properties of thermally anisotropic heterogeneous samples includes a heating element, a first temperature sensing device, a second temperature sensing device, and a computing system. The heating element is positioned at a first location within a sample and heats the sample. The first temperature sensing device outputs data indicative of temperatures of the first location to the computing device. The second temperature sensing device outputs data indicative of temperatures of the second location to the computing device. The computing device computes a thermal conductivity of the sample based upon the temperatures of the first location. The computing device further outputs an indication of a portion of the sample to which the thermal conductivity pertains based upon the second temperatures.

Reyes, Karla Rosa↗

Apparatus and systems for measuring elongation of objects, methods of measuring, and reactor

Elongation measurement apparatuses and systems comprise at least two Linear Variable Differential Transformers (LVDTs) with a push rod coupled to each of the at least two LVDTs at one longitudinal end thereof. At least one push rod extends to a base and is coupled thereto at an opposing longitudinal end, and at least one other push rod extends to a location spaced apart from the base and is configured to receive a sample between an opposing longitudinal end of the at least one other push rod and the base. Nuclear reactors comprising such apparatuses and systems and methods of measuring elongation of a material are also disclosed.

47 OTHER INSTRUMENTATION↗

Time-reversed nonlinear acoustic downhole pore pressure measurements

Apparatus (10) and methods for measurement of pore pressure in rock formations through a metal borehole casing (32) after a well is cased and cemented, are described. Such measurements may be accomplished by using the Dynamic Acoustic Elasticity (DAE) method for characterizing nonlinear parameters by perturbing a selected rock formation region with a High Amplitude, Low Frequency (HALF) acoustic strain wave, and probing this region using a Low Amplitude, High Frequency (LAHF) acoustic wave (18), (22). Time reversal techniques (36) may be employed for focusing acoustic energy into the formation in the vicinity of the pipe or open hole. The change in wave speed of the probe pulses as the HALF induced strain wave oscillation propagates through the formation, as a function of the induced strain, may be used to determine the nonlinear elastic parameters α, β, δ, and A of the pore pressure, from which the pore pressure may be determined in the region of the HALF wave.

Goodman, Harvey E.↗

Method and apparatus for measuring biofilm thickness and topology

An apparatus and method of measuring biofilm and biological activity on a surface is disclosed. The apparatus includes a biofilm, which includes one or more microorganisms, grown on a substrate. A viewing window is placed on a surface of the biofilm and a gas bubble is introduced between the viewing window and the surface of the biofilm. The space between the substrate and the viewing window may be enclosed in a casing that has an inlet and an outlet, forming a flow cell. A microscope system, such as a white light interferometer, captures data of the biofilm in situ and non-destructively. The 3D images of biofilm surface have high resolution while maintaining a large field of view. The apparatuses and methods will be useful for fundamental studies of biofilms, biomedical and environmental screening, and many other applications in biology and the life sciences.

Larimer, Curtis J.↗

A robust and well shielded thermal conductivity device for low temperature measurements

We present a compact mechanically robust thermal conductivity measurement apparatus for measurements at low temperatures (<1 K) and high magnetic fields on small high-purity single crystal samples. A high-conductivity copper box is used to enclose the sample and all the components. The box provides protection for the thermometers, heater, and most importantly the sample increasing the portability of the mount. In addition to physical protection, the copper box is also effective at shielding radio frequency electromagnetic interference and thermal radiation, which is essential for low temperature measurements. A printed circuit board in conjunction with a braided ribbon cable is used to organize the delicate wiring and provide mechanical robustness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗

Apparatus to measure permeation of a gas through a membrane

The present invention relates to an apparatus to measure permeation of a gas through a membrane. The membrane is mounted on a flange with two sealing areas. The region between the sealing areas defines an annular space. The annular space is swept with a gas in order to carry away any of the permeating gas which may leak through the sealing areas.

42 ENGINEERING↗