Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MC-15”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DAQs Quick Start Guide

DAQs is a Windows® computer app designed to communicate with the Advanced List Mode Module (ALMM), MC-15, and instrumentation based off these platforms. The ALMM communicates with DAQS over the Ethernet using TCP/IP. If you register the IPv4 address of the ALMM on the local network the ALMM can be operated remotely. However, if the ALMM is not connected to the local network then the computer running DAQs will need to be connected directly to the ALMM or an additional Ethernet adapter will need to be installed on the acquisition computer. The IPv4 address can be changed in the rei.ini file located on the µSD card. Please see the appendices for more information on the rei.ini file. This document is intended to be a quick start guide on how to get an ALMM connected to a computer and how to start a data acquisition. DAQs has much more capability than is presented in this document.

97 MATHEMATICS AND COMPUTING↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyramidal structures on Mars

Triangular and polygonal pyramid like structures have been observed on the Martian surface. Located in the east central portion of Elysium Quadrangle (MC-15), these features are visible on the Mariner 9 photographs. B frames MTVS 4205-3 DAS 07794853 and MTVS 4296-24 DAS 12985882. The structures cast triangular and polygonal shadows. Steep-sided volcanic cones and impact craters occur only a few kilometers away. The mean diameter of the triangular pyramidal structures at the base is approximately 3.0 km, and the mean diameter of the polygonal structures is approximately 6.0 km. The observed Martian structures tend to line up suggesting joint or fault control. However, they do not appear to be controlled by the visible faults. The structures appear to be either wind-faceted volcanic cones and blocks or solidified blocks which have been rotated in semiconsolidated lava.

Gipson, M., Jr.↗

Progress in compilation of the 1:2,000,000-scale topographic map

The application of special photogrammetric techniques has enabled the systematic mapping of Mars' topography at a scale of 1:2,000,000, using high-altitude Viking Orbiter pictures. In fiscal 86, compilation was completed of the 24 subquadrangles that make up the quadrangles MC-12, MC-13, MC-14, MC-15, MC-20, and MC-21. This work completes compilation of the 60 topographic maps covering the equatorial belt (lat. + or - 30 deg). The remaining 80 subquadrangles of Mars are planned to be completed within 3 years (27, 27 and 26 subquadrangles, in fiscal 87, 88, and 89, respectively). Elevations on all topographic maps are relative to the Mars topographic datum. The maps have a contour interval of 1 km and a precision of + or - 1 km. The equatorial-belt maps are Mercator projections having true scale at lat. + or - 27.476 deg. These maps provide more precise information than do those previously available and they will help in understanding the geologic processes that have shaped the Martian surface.

Wu, Sherman S. C.↗