DE-1 observations of hole electron distribution functions and the cyclotron maser resonance

The hole electron distribution functions observed by the DE-1 satellite within inverted-V events at altitudes of between 9000 km and 15,000 km are examined as a possible free energy source for exciting Z-mode radiation through cyclotron maser resonance. In the DE-1 observations the hole distribution function had center velocities varying between 8000 km/s and 20,000 km/s, with the radii varying between 2000 km/s and 10,000 km/s. The observed distribution function is fitted by an exponential function around the center of the hole, and is used to calculate growth rates of Z-mode radiation. Growth rates as high as 0.001 of the electron gyrofrequency are obtained. It is also shown that the observed hole distribution functions can excite Z-mode radiation at wave frequencies slightly above the gyrofrequency, and wave propagation angles slightly below 90 deg in the source region. The results suggest that the hole distribution function could provide additional amplification for Z-mode waves in the auroral zone.

Lin, C. S.

Mechanically and thermally stable maser cavity resonator

New type cavity resonator is designed for hydrogen maser. Resonator consists of three pieces of glass-ceramic material having extremely low thermal coefficient of expansion and provides very stable mechanical tuning.

Vessot, R. F. C.

Ray tracing survey of Z mode emissions from source regions in the high-altitude auroral zone

The ray tracing computer program described by Menietti and Lin (1985) was used to investigate the propagation of Z mode emissions from sources in the auroral zone. The calculation results indicate that the propagation is primarily perpendicular to the magnetic field line (horizontal propagation) for almost all sources considered, except when the wave source is assumed to be unrestricted by the cyclotron maser mechanism. While the propagation is initially downward, refraction rapidly increases the wave normal angle, and only propagation at near-constant altitude occurs. The frequency bandwidth estimated from the ray paths was found to be less than that observed by the DE 1 satellite. Large horizontal magnetic field gradients associated with field-aligned currents produce downward propagation but are still not sufficient to produce the observed bandwidths. The results suggest that wave growth may be due to mechanisms in addition to cyclotron maser resonance.

Menietti, J. D.

Operation of a step tunable megawatt gyrotron

An electron cyclotron resonance maser; gyrotron fundamental oscillator; advantages of gyrotrons; a schematic of the experiment; gyrotron design theory; 1 MW design parameters; compact ignition tokamak; and a gyrotron with quasi-optical output coupler are briefly presented. This presentation is represented by viewgraphs only.

Kreischer, K. E.

Maser Oscillator With Dielectric Resonators

Two-resonator design yields low phase noise. Oscillator exhibits phase noise intermediate between phase noises of unstablized microwave oscillators and stabilized ruby-maser oscillators with superconducting cavities. Contains two total-internal-reflection dielectric resonators in normally-conductive copper cavity. Two-resonator maser design provides phase stability, isolation between pump and output channels, and variable maser coupling.

Dick, G. John

Resonant isolator for maser amplifier

An isolator is described for use in a low noise maser amplifier, which provides low loss across a wide bandwidth and which can be constructed at moderate cost. The isolator includes a train of garnet or ferrite elements extending along the length of a microwave channel parallel to the slow wave structure, with the elements being of staggered height, so that the thin elements which are resonant to the microwaves are separated by much thicker elements. The thick garnet or ferrite elements reduce the magnetic flux passing through the thin elements to permit altering of the shape of the thin elements so as to facilitate their fabrication and to provide better isolation with reduced loss, by increasing the thickness of the thin elements and decreasing their length and width.

Clauss, R. C.

Effect of thermal cycling on stress in metallic films on ceramic substrates

The hydrogen maser is the most stable frequency standard currently available for averaging intervals of hours to weeks. A major contributor to maser frequency variations is the maser's microwave resonant cavity: by means of the cavity pulling effect, a change in the cavity's resonance frequency produces a proportional change in the maser's output frequency. To minimize variations in the cavity's dimensions, and thus in its resonance frequency, maser cavities are often constructed of a low-expansivity glass-ceramic material coated on its surface with a conductive metallic film. It was previously shown that silver films like those used in SAO maser cavities develop tensile stress when cooled to room temperature after being fired onto the cavity, and that the stress in such films relaxes with time at a rate proportional to the level of stress. Stress relaxation in maser cavity coatings can alter the shape, and hence the resonance frequency, of the cavity, resulting in a slow variation in the maser's output frequency. The possibility was investigated of reversing the initial tensile stress by precooling the coated cavity material. It was hypothesized that cooling the material well below its normal working temperature and then warming it to its normal temperature would result in a lower tensile stress or even a compressive stress. Under such a condition stress relaxation, and thus any consequent frequency drifts, might be reduced or reversed.

Mattison, Edward M.

Resonant electron diffusion as a saturation process of the synchrotron maser instability

The theory of resonant electron diffusion as an effective saturation process of the auroral kilometric radiation has been formulated. The auroral kilometric radiation is assumed to be amplified by the synchrotron maser instability that is driven by an electron distribution of the loss-cone type. The calculated intensity of the saturated radiation is found to have a significantly lower value in comparison with that caused by the quasi-linear diffusion process as an alternative saturation process. This indicates that resonant electron diffusion dominates over quasi-linear diffusion in saturating the synchrotron maser instability.

Lee, M. C.

Atomic hydrogen maser active oscillator cavity and bulb design optimization

The performance characteristics and reliability of the active oscillator atomic hydrogen maser depend upon oscillation parameters which characterize the interaction region of the maser, the resonant cavity and atom storage bulb assembly. With particular attention to use of the cavity frequency switching servo (1) to reduce cavity pulling, it is important to maintain high oscillation level, high atomic beam flux utilization efficiency, small spin exchange parameter and high cavity quality factor. It is also desirable to have a small and rigid cavity and bulb structure and to minimize the cavity temperature sensitivity. Curves for a novel hydrogen maser cavity configuration which is partially loaded with a quartz dielectric cylinder and show the relationships between cavity length, cavity diameter, bulb size, dielectric thickness, cavity quality factor, filling factor and cavity frequency temperature coefficient are presented. The results are discussed in terms of improvement in maser performance resulting from particular design choices.

Peters, H. E.

Cavity-Modulation Autotuner For Hydrogen Maser

Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.

Dick, G. J.

On the line Q degradation in hydrogen masers

In hydrogen masers, the atomic resonance quality factor is largely determined by the properties of the Teflon coating on the quartz storage bulb. Normally a good Teflon coating will last many years. On the other hand, there may be a relatively fast degradation of the quality factor if the Teflon coating is bad. A series of observations and measurements performed on an hydrogen maser that had successively a bad and a good Teflon coating are discussed.