Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low-energy ionization detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron 𝛽 decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25, 30, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one-year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from 109Cd and 113Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from (2±2)×109/cm3 at the center to (26±2)×109/cm3 at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

Taylor, RJ [North Carolina State University]↗

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics↗

Small area silicon diffused junction X-ray detectors

The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.

Walton, J. T.↗

Higher-Sensitivity Ionization Trace-Species Detector

Electron source and electron optics of reversal electron-attachment detector modified to increase sensitivity. Original version described in "High-Sensitivity Ionization Trace-Species Detector" (NPO-17596). Used to detect molecules of particular chemical species of interest (e.g., narcotics, explosives, or organic wastes) present in air at low concentrations, and known to attach extremely low-energy electrons. Apparatus does this by ionizing molecules from sampled atmosphere, then detecting ions of species of interest. Detector features indirectly heated spherical cathode and redesigned electron optics, together, deliver more electrons at low kinetic energy to reversal plane, R. Greater electron current generates more ions for detection.

Boumsellek, Said↗

Study of few-electron backgrounds in the LUX-ZEPLIN detector

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/𝑐 2 –TeV/𝑐 2 weakly interacting massive particles (WIMPs), it is also capable of measuring low-energy ionization signals down to a single electron that may be produced by scatters of sub-GeV/𝑐 2 dark matter. The major challenge in exploiting this sensitivity is to understand and suppress the ionization background in the few-electron regime. We report a characterization of the delayed electron backgrounds following energy depositions in the LZ detector under different detector conditions. In addition, we quantify the probability for photons to be emitted in coincidence with electron emission from the high voltage grids. We then demonstrate that spontaneous grid electron emission can be identified and rejected with a high efficiency using a coincident photon tag, which provides a tool to improve the sensitivity of future dark matter searches.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Pulsed, gridded electron reversal ionizer

The design and performance of a new-type source of negative ions is presented. This device retains the idea of the so-called reversal electron attachment detector to produce low-energy electrons by reversing electron trajectories at an electrode. Electrons are produced in the present device by several ribbon filaments that surround a cylindrical wire grid. They are accelerated through the grid, then decelerated to zero or near-zero velocity at the surface of a tube. The tube (anode) is perforated with small holes through which effuse the target molecules. Electrons attach to form either parent and/or fragment negative ions. Attachment takes place at a location above the anode corresponding to a match between the electron energy and the attachment resonance energy. Negative ions are pulsed out of the attachment region and focused onto the entrance plane of a quadrupole mass selector. Electron and ion trajectory calculations are presented and the performance illustrated with six molecules having attachment resonances in the range 0.0-2.2 eV. The detection sensitivity is below 1 part-per-trillion, with a calculated conversion rate of 1.3 percent. Signal nonlinearity is discussed in terms of ion space-charge effects. The device also produces positive ions, and an analogous treatment may be carried through to characterize its performance in this mode.

Boumsellek, S.↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

A comprehensive study of the X-ray structure and spectrum of IC 443

This paper presents the results of a comprehensive study of the X-ray emission from the supernova remnant IC 443, using the solid state spectrometer, IPC, and high-resolution images of the Einstein Observatory, and the medium-energy detector of the HEAO 1 A-2 experiment. A soft X-ray appearance was observed, highly atypical of a supernova remnant in the adiabatic phase, with little correlation between X-ray and optical or radio features. The best-fit models of the low-energy X-ray spectrum of the brightest area of the remnant suggest either that the remnant has not yet attained ionization equilibrium or that the X-rays arise in a multiphase medium. Pronounced soft X-ray spectral differences across the remnant are accounted for by variations in absorption by an intervening molecular cloud. The analysis suggests that, despite the atypical X-ray appearance, the X-ray emission in IC 443 is probably confined to a thin (0.1 pc) shell.

Petre, R.↗

Investigation of low-energy particle remnants in high-energy collisions at the LHC with a skipper-CCD detector

We deployed the Mobile Skipper Testing Apparatus ∼33 m away from the Compact Muon Solenoid collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider. In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb −1 and 1.54 nb −1 for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: ≤ 20⁢𝑒 − and > 20⁢𝑒 − . For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% confidence level constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

Cervantes-Vergara, Brenda A. [Fermi National Accel↗

Radiation Tests of the Extravehicular Mobility Unit Space Suit for the International Space Station Using Energetic Protons

Measurements using silicon detectors to characterize the radiation transmitted through the EMU space suit and a human phantom have been performed using 155 and 250 MeV proton beams at LLUMC. The beams simulate radiation encountered in space, where trapped protons having kinetic energies on the order of 100 MeV are copious. Protons with 100 MeV kinetic energy and above can penetrate many centimeters of water or other light materials, so that astronauts exposed to such energetic particles will receive doses to their internal organs. This dose can be enhanced or reduced by shielding - either from the space suit or the self-shielding of the body - but minimization of the risk depends on details of the incident particle flux (in particular the energy spectrum) and on the dose responses of the various critical organs. Data were taken to characterize the beams and to calibrate the detectors using the beam in a treatment room at LLUPTF, in preparation for an experiment with the same beams incident on detectors placed in a human phantom within the EMU suit. Nuclear interactions of high-energy protons in various materials produce a small flux of highly ionizing, low-energy secondary radiation. Secondaries are of interest for their biological effects, since they cause doses and especially dose-equivalents to increase relative to the values expected simply from ionization energy loss along the Bragg curve. Because many secondaries have very short ranges, they are best measured in passive track detectors such as CR-39. The silicon detector data presented here are intended to supplement the CR-39 data in regions where silicon has greater sensitivity, in particular the portion of the LET spectrum below 5 keV/micron. The results obtained in this study suggest that optimizing the radiation shielding properties of space suits is a formidable task. The naive assumption that adding mass can reduce risk is not supported by the data, which show that reducing the dose delivered at or near the skin by low-energy particles may increase the dose delivered by energetic particles to points deeper in the body.

Zeitlin, C.↗

Electron-ion recombination in composite interactions in liquid xenon

The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions associated with different primary particles leads to additional suppression of the ionization signal, introducing a new source of uncertainty in dark matter searches and Migdal effect studies. We developed a model to estimate the recombination enhancement for overlapping low-energy particle interactions. This method, which has minimal dependence on xenon microphysics and is primarily driven by existing experimental data, yields predictions that are consistent with available measurements of composite interactions. Furthermore, we demonstrate that the model predictions are robust against xenon microphysics assumptions.

charge↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Gas electroluminescence in a dual phase xenon-doped argon detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. Here, in this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At ∼2% xenon doping in liquid argon, we measured ∼34 ppm of xenon in the gas and observed ∼2.5 times larger electroluminescence signals using vacuum ultraviolet silicon photomultipliers than those in pure argon. Analysis of signals of different wavelengths confirms that the argon gas electroluminescence process is strongly modified by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low-energy ionization signal detection will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the molecular Migdal effect with neutron scattering on diatomic gases

The Migdal effect is a key inelastic signal channel which could be used to detect low-mass dark matter, but it has never been observed experimentally using Standard Model probes. Here we propose a conceptual design for an experiment which could detect the Migdal effect in diatomic molecules through low-energy neutron scattering, and we provide the requirements on the beam spectrum and reducible backgrounds such that a detection may be achieved. The enhancement of the Migdal rate through non-adiabatic couplings, which are absent in isolated atoms, combined with the distinctive photon energies of electronic transitions in CO, suggest that a positive detection of the molecular Migdal effect may be possible with modest beam times at existing neutron facilities. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Neutron Identification Capabilities in MicroBooNE Through the Application of Machine Learning with Blips

Neutrinos (ν) are subatomic particles first observed in 1956 by LANL physicists Clyde Cowan and Frederick Reines but first theorized by Wolfgang Pauli in 1930. Neutrinos are the least massive known particle and are classified as leptons with 3 flavors corresponding to their leptonic counterparts (electron, muon, and tau). We know that they are abundant, 65 billion neutrinos travel through your fingertip every second, and elusive, a single neutrino could fly through a lightyear of lead without interacting at all. Though, there is much still unknown and a better characterization of these “ghostly” particles can give us clues as to the matter/anti-matter asymmetry in the early universe and possible glimpses into new physics. To measure a particle that is extremely light and rarely interacting, physicists have developed an extremely sensitive detector known as a Liquid Argon Time Projection Chamber (LArTPC). The fiducial volume (or TPC) is bombarded with neutrinos, some of which interact with argon (Ar) atoms to produce particles that in turn excite and ionize the Ar. The products of these are free electrons which then drift through the TPC’s applied magnetic field towards a multi-plane wire readout system. The electrons’ charge is collected at this anode and the light from the initial interactions is collected by photomultiplier tubes (PMTs). In conjunction, these mechanisms allow LArTPCs to achieve millimeter spatial resolution and sub-MeV energy thresholds. The detector of interest in this study is the MicroBooNE Experiment at Fermilab. MicroBooNE is an above ground LArTPC with dimensions of approximately 10m × 2.5m × 2.3m, about the size of a school bus. Its purpose is to study neutrinos, so to improve rates of measured ν interactions, the detector is squarely in the path of the Booster Neutrino Beam (BNB) at Fermilab. A major challenge in neutrino studies is energy reconstruction, much of the neutrino’s original energy is lost in interactions that the detector is not sensitive to, often due to low-energy products. The initial goal of this analysis was to better identify neutrons, the main source of poor energy reconstruction in neutrino events. Because neutrons are neutral particles, like neutrinos, we can only directly measure the products of their interactions in LArTPCs. Most of these products are low-energy signals and while each one contributes a negligible amount of energy, collectively these signals make up most of the lost energy in each neutrino event. We define these signals as blips; point-like, isolated depositions of charge in the detector. Blips have MeV-scale energies and are the size of a single hit (charge deposition) or a cluster of a few hits on at least two wire planes. Blips are the principal detector features used to study low-energy physics; thus, they are the key to unlocking information not only about neutrons but gamma photons, supernova and solar neutrinos as well as helping us better identify certain particles. Therefore, this analysis strives to use blips for improved neutron identification (ID) and characterization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Tagging From Neutrino Interactions in DUNE-ND 2x2 Prototype

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims to measure whether CP is violated in the leptonic sector (if violated, how much) and unambiguously determine the neutrino mass ordering. DUNE consists of near and far detectors that rely on liquid argon time projection chamber (LArTPC) technology to observe neutrino interactions. The near detector (ND) will be placed in Fermilab, near the neutrino source, while the far detector (FD) will be deployed in Sanford Lab, 1.5 km deep underground, which is 1300 km away from the source. LArTPCs provide excellent particle identification and calorimetry; however, detecting neutrons is challenging, as they do not leave direct ionization signals in LArTPCs. Neutrons can carry away up to 25% of the neutrino energy, introducing a significant uncertainty in DUNE measurements. The DUNE near detector (ND) features a novel modular LArTPC with pixelated charge readout, which enhances event recons truction. The modular design enables precise correlation between ionization signals and light signals in a high-rate environment, improving the identification of delayed energy depositions from neutrons in neutrino interactions. We introduce a neutron tagging technique using the 2x2 Demonstrator, a small-scale prototype of the DUNE ND LArTPC. The analysis utilizes Monte Carlo simulations and deep-learning techniques to identify neutron-induced energy depositions and reconstruct low-energy activity.

Kufatty, Georgette [Florida State U.]↗

Calculation of energy deposition distributions for simple geometries

When high-energy charged particles pass through a thin detector, the ionization energy loss in that detector is subject to fluctuations or straggling which must be considered in interpreting the data. Under many conditions, which depend upon the charge and energy of the incident particle and the detector geometry, the ionization energy lost by the particle is significantly different from the energy deposited in the detector. This problem divides naturally into a calculation of the energy loss that results in excitation and low-energy secondary electrons which do not travel far from their production points, and a calculation of energy loss that results in high-energy secondary electrons which can escape from the detector. The first calculation is performed using a modification of the Vavilov energy loss distribution. A cutoff energy is introduced above which all electrons are ignored and energy transferred to low energy particles is assumed to be equivalent to the energy deposited by them. For the second calculation, the trajectory of the primary particle is considered as a source of secondary high-energy electrons. The electrons from this source are transported using Monte Carlo techniques and multiple scattering theory, and the energy deposited by them in the detector is calculated. The results of the two calculations are then combined to predict the energy deposition distribution. The results of these calculations are used to predict the charge resolution of parallel-plate pulse ionization chambers that are being designed to measure the charge spectrum of heavy nuclei in the galactic cosmic-ray flux.

Watts, J. W., Jr.↗

Workshop on Cosmic Ray and High Energy Gamma Ray Experiments for the Space Station Era, Louisiana State University, Baton Rouge, October 17-20, 1984, Proceedings

The potential of the Space Station as a platform for cosmic-ray and high-energy gamma-ray astronomy is discussed in reviews, reports, and specific proposals. Topics examined include antiparticles and electrons, science facilities and new technology, high-energy nuclear interactions, nuclear composition and energy spectra, Space Shuttle experiments, Space Station facilities and detectors, high-energy gamma rays, and gamma-ray facilities and techniques. Consideration is given to universal-baryon-symmetry testing on the scale of galactic clusters, particle studies in a high-inclination orbit, balloon-borne emulsion-chamber results on ultrarelativistic nucleus-nucleus interactions, ionization states of low-energy cosmic rays, a large gamma-ray telescope for point-source studies above 1 GeV, and the possible existence of stable quark matter.

Jones, W. V.↗