Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low-background detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for Light Dark Matter Searches at Large-Volume Neutrino Detectors

We propose a new approach to search for light dark matter (DM), with keV–GeV mass, via inelastic nucleus scattering at large-volume neutrino detectors such as Borexino, DUNE, Super-K, Hyper-K, and JUNO. The approach uses inelastic nuclear scattering of cosmic-ray boosted DM, enabling a low-background search for DM in these experiments. Large neutrino detectors, with higher thresholds than dark matter detectors, can be used, since the nuclear deexcitation lines are O ( 10 ) MeV . Using a hadrophilic dark-gauge-boson-portal model as a benchmark, we show that the nuclear inelastic channels generally provide better sensitivity than the elastic scattering for a large region of light DM parameter space. Published by the American Physical Society 2024

Dutta, Bhaskar↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗