Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low-background detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Integrated infrared detector arrays for low-background astronomy

Existing integrated infrared detector array technology is being evaluated under low-background conditions to determine its applicability in orbiting astronomical applications where extended integration times and photometric accuracy are of interest. Preliminary performance results of a 1 x 20 elements InSb CCD array under simulated astronomical conditions are presented. Using the findings of these tests, improved linear- and area-array technology will be developed for use in NASA programs such as the Shuttle Infrared Telescope Facility. For wavelengths less than 30 microns, extrinsic silicon and intrinsic arrays with CCD readout will be evaluated and improved as required, while multiplexed arrays of Ge:Ga for wavelengths in the range 30 to 120 microns will be developed as fundamental understanding of this material improves. Future efforts will include development of improved drive and readout circuitry, and consideration of alternate multiplexing schemes.

Mccreight, C. R.↗

Assessment study of infrared detector arrays for low-background astronomical research

The current state-of-the-art of infrared detector arrays employing charge coupled devices (CCD) or charge injection devices (CID) readout are assessed. The applicability, limitations and potentials of such arrays under the low-background astronomical observing conditions of interest for SIRFT (Shuttle Infrared Telescope Facility) are determined. The following are reviewed: (1) monolithic extrinsic arrays; (2) monolithic intrinsic arrays; (3) charge injection devices; and (4) hybrid arrays.

Ando, K. J.↗

Low-background trace-gas detector

Spectrophone detects very small concentrations of trace gases. With gas in sample cell, laser is tuned to absorption line of interest. Molecular absorption in cell produces pulsed acoustical pressure at chopper frequency. Two optical paths with very different absorption lengths are used to pretune cell to balance out background absorption by cell windows.

Rosengren, L.↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Ge:Ga and Ge:Be photoconductive detectors for far infrared astronomy from a space platform

The paper describes some of the development work on gallium-doped germanium (Ge:Ga) and beryllium-doped germanium (Ge:Be) photoconductive detectors for use in far-infrared astronomical observations from a space platform such as IRAS. The paper is concerned primarily with detector performance and is divided into two major parts. The first presents the operating principles of this type of detector, while the second presents measured performance data under low-background flux conditions. It is shown that high sensitivity can be obtained from Ge:Ga and Ge:Be detectors under low-background and low-temperature conditions of operation. These detectors are useful for astronomical observations in the far-infrared over the wavelength range 30-120 microns. Major conclusions of the research work done so far are mentioned, including that detectors cut from the same crystal show reasonably good reproducibility of operating characteristics.

Bratt, P. R.↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-background performance of a monolithic InSb CCD array

A 20 element monolithic InSb charge coupled device (CCD) detector array was measured under low background conditions to assess its potential for orbital astronomical applications. At a temperature of 64 K, previous results for charge transfer efficiency (CTE) were reproduced, and a sensitivity of about 2 x 10 to the minus 15th power joules was measured. At 27 and 6 K, extended integration times were achieved, but CTE was substantially degraded. The noise was approximately 6000 charges, which was in excess of the level where statistical fluctuations from the illumination could be detected. A telescope demonstration was performed showing that the array sensitivity and difficulty of operation were not substantially different from laboratory levels. Ways in which the device could be improved for astronomical applications were discussed.

Bregman, J. D.↗

Infrared charge-injection-device array performance at low background

Low-background tests of a 1 x 32 Si:Bi charge-injection-device (CID) IR detector are carried out to evaluate its feasibility for space-based astronomical observations. Optimum performance is obtained at a temperature of 11 K. The sensitivity is found to compare well with that of discrete extrinsic silicon photoconductors. The measured sensitivity and the apparent absence of anomalous effects make extrinsic silicon CID arrays very promising for astronomical applications.

Mccreight, C. R.↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Tests of low background photo conductors

In support of two infrared astronomy space projects, the IRAS satellite and the IRT on Spacelab 2, low-background tests were carried out on the performance and characterization of Si:Ga, Si:As, Si:Sb and Ge:Ga photoconductive detectors. These test results represent a useful appraisal of this family of detectors when operated at 1.8-4.2 K and at background power levels of 10 to the -14th to 10 to the -13th W. In addition to detector performance data, results are also presented on cryogenically cooled MOSFET amplifiers operated in the source follower and in the balanced-dc-TIA configurations.

Young, E. T.↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗