Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Load, Cold Start”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Improving Unit Flexibility Utilizing Plasma Ignitors

Coal fired steam generation operators face increasing market challenges, including competition from low cost generation, renewables, and regulatory pressure. These market conditions are forcing utilities to operate their coal assets in a more flexible mode, including more frequent starts and stops, faster ramp rates, frequent cycling, and extended operation at the lowest possible loads. Without upgrades to firing and control systems, pressure parts, and auxiliary systems, CAPEX and OPEX costs will increase significantly. Typically, expensive support fuels (Oil or Gas) are required to maintain safe, stable coal ignition when operating below 25% to 35% MCR (Maximum Continuous Rating). The exact minimum load without support fuel differs depending upon unit design specifications and fuel being burned. Frequent starts also increase the use of support fuels. The firing and burner control systems must be designed to allow for proper operation over the unit’s load range, ensuring that all mechanical components operate properly, and proper control of air and fuel streams can be maintained. To address the need for frequent starts and the need for stable low load operation on coal fired steam generators, this paper discusses options available, including, Firing Systems upgrades, Digital solutions, and pressure part upgrades. Several case studies are included that highlight options available allowing units to stay in operation and reduce CAPEX and OPEX costs.

01 COAL, LIGNITE, AND PEAT↗

Co-optimized Mixed-Mode Engine and Fuel Demonstrator for Improved Fuel Economy while Meeting Emissions Requirements

Progressively increasing regulatory demands on fuel economy and future global emission standards have led to a focus on advanced engine development to improve overall engine efficiency and fulfill emission requirements. Low temperature combustion (LTC) and gasoline compression ignition (GCI) are promising technologies to achieve these goals and have the advantage of using existing refinery infrastructure and subsequent economies of scale for a robust energy supply. By applying spark ignition (SI) for cold start, LTC for low load operations, and GCI for medium to high load operations, a multimode GCI engine concept was proposed and the fuel formation was co-optimized to maximize fuel economy improvement potential while maintaining ULEV 70 emissions standards. HATCI has successfully demonstrated the feasibility of this multimode GCI engine concept, and confirmed the fuel economy improvement over the baseline SI engine by simulating the FTP75 vehicle drive cycle. In this report, the technical approaches, multimode engine control, and engine test results of both steady state and transitions, CFD modeling, fuel testing, and FTP75 drive cycle simulation results are summarized, followed with technical challenges observed, and recommendations for possible follow-up studies.

02 PETROLEUM↗

Black carbon emissions from modern automated cordwood stoves for space heating

Wood burning stove design is improving as regulation become stricter for particulate matter emissions. Here, this study describes results of black carbon (BC) emissions from three modern automated wood stoves when tested in common failure modes using a test protocol that included cold-starts, high and low fuel loading densities, and use of overly large pieces of fuel. Emission sampling was performed using a dilution sampling system in tandem with an aethalometer to measure BC with high time resolution. Results show that the time-weighted average BC emission rates were 0.91, 4.30, and 1.74 g/h for the three stoves tested (A, B, and C respectively), the values, both higher and lower than the United States 2020 certification test emission limit of 2.5 g/h. The results demonstrate good performance overall, given the rigorous nature of the testing protocol used. The aethalometer data showed that the performance was relatively poor during cold-start, when the fuel was ignited and combusted without a coalbed, and when stoves failed to optimize air delivery due to specific loading and output conditions. During the cold-start test section, the average BC emission rate was seven times higher than the overall average for Stove A, 10 times above the average for Stove B, and two times above the average emission rate for Stove C. Calculations of the Average Angstrom Absorption Exponent (AAE) of the exhaust aerosol showed little correlation with BC concentration. The results show that automation results in a quantifiable reduction in particular BC emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient response of a high-capacity heat pipe for Space Station Freedom

High-capacity heat pipe radiator panels have been proposed as the primary means of heat rejection for Space Station Freedom. In this system, the heat pipe would interface with the thermal bus condensers. Changes in system heat load can produce large temperature and heat load variations in individual heat pipes. Heat pipes could be required to start from an initially cold state, with heat loads temporarily exceeding their low-temperature transport capacity. The present research was motivated by the need for accurate prediction of such transient operating conditions. In this work, the cold startup of a 6.7-meter long high-capacity heat pipe is investigated experimentally and analytically. A transient thermohydraulic model of the heat pipe was developed which allows simulation of partially-primed operation. The results of cold startup tests using both constant temperature and constant heat flux evaporator boundary conditions are shown to be in good agreement with predicted transient response.

Ambrose, J. H.↗

Development of Clean Condensing Furnace Using Advanced Catalyst

A clean condensing furnace was developed by using acidic gas reduction (AGR) catalysts. The AGR catalyst technology is capable of minimizing condensate acidity and NOx emissions in advanced gas furnace. In the study, different AGR catalyst materials were explored. The AGR with low Pt/Rh loading achieves an improved annual fuel utilization efficiency (AFUE) without impairing the performance in achieving neutral condensate and ultralow NOx emissions. The AGR with low Pt/Rh loading enables even better ability to convert NOx. Moreover, the low-cost AGR realizes nearly zero cold-start CO emissions, as is attractive in the battle to keep public safe from dangerous CO in furnaces.

Gao, Zhiming↗

A platform for planar dynamic compression of crystalline hydrogen toward the terapascal regime

Here we describe a method for laser-driven planar compression of crystalline hydrogen that starts with a sample of solid para-hydrogen (even-valued rotational quantum number j) having an entropy of 0.06 k B /molecule at 10 K and 2 atm, with Boltzmann constant k B . Starting with this low-entropy state, the sample is compressed using a small initial shock (<0.2 GPa), followed by a pressure ramp that approaches isentropic loading as the sample is taken to hundreds of GPa. Planar loading allows for quantitative compression measurements; the objective of our low-entropy compression is to keep the sample cold enough to characterize crystalline hydrogen toward the terapascal range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lunar Reconnaissance Orbiter (LRO) Rapid Thermal Design Development

The Lunar Reconnaissance Orbiter (LRO) project had a rapid development schedule starting with project conception in spring of 2004, instrument and launch vehicle selection late in 2005 and then launch in early 2009. The lunar thermal environment is one of the harshest in our solar system with the heavy infrared loading of the moon due to low albedo, lack of lunar atmosphere, and low effective regolith conduction. This set of constraints required a thermal design which maximized performance (minimized radiator area and cold control heater power) and minimized thermal hardware build at the orbiter level (blanketing, and heater service). The orbiter design located most of the avionics on an isothermalized heat pipe panel called the IsoThermal Panel (ITP). The ITP was coupled by dual bore heat pipes to an Optical Solar Reflector (OSR) covered heat pipe radiator. By coupling all of the avionics to one system, the hardware was simplified. The seven instruments were mainly heritage instruments which resulted in their desired radiators being located by their heritage design. This minimized instrument redesigns and therefore allowed them to be delivered earlier, though it resulted in a more complex orbiter level blanket and heater service design. Three of the instruments were mounted on a tight pointing M55J optical bench that needed to be covered in heaters to maintain pointing. Two were mounted to spacecraft controlled radiators. One was mounted to the ITP Dual Bores. The last was mounted directly to the bus structure on the moon facing panel. The propulsion system utilized four-20 pound insertion thrusters and eight-5 pound attitude control thrusters (ACS) in addition to 1000 kg of fuel in two large tanks. The propulsion system had a heater cylinder and a heated mounting deck for the insertion thrusters which coupled most of the propulsion design together simplifying the heater design. The High Gain Antenna System (HGAS) and Solar Array System (SAS) used dual axis actuator gimbal systems. HGAS required additional boom heaters to cool the approximately 10 W of RF losses thru the rotary joints and wave guides from the 40 W Ka system. By design this module needed a fair amount of heater, blanketing, and radiator complexity. The SAS system required a separate cable wrap radiator to help cool the Solar Array harness which dissipated 30 W thru the actuators and cable wraps. This module also was complex.

Baker, Charles↗

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion↗

Zero-CO Residential Natural Gas Furnace

Residential natural gas furnaces are widely used in the US homes. Manufacturers dedicate significant design and testing resources to meet requirements of design standards. One area of these standards is controlling flue gas carbon monoxide (CO) emissions. To more effectively reduce CO emissions at the flue, we developed a novel catalyst-assisted approach that integrated a low Pt/Rh loading acidic gas reduction (AGR) catalyst with three-way catalyst (TWC) or diesel oxidation catalyst (DOC) components. Compact catalysts were fabricated and assembled into tubular components, which can be seamlessly incorporated into the primary heat exchanger of a representative commercially available condensing furnace. The retrofitted furnace was demonstrated and tested following ANSI/ASHRAE Standard 103-2017. Experimental results showed that both AGR/TWC and AGR/DOC configurations achieved near-zero CO emissions under steady-state and cold-start conditions, compared with up to 500 ppm at a cold start and 17 ppm in a steady state in the OEM furnace. The catalyst-assisted furnaces also exhibited an annual fuel utilization efficiency improvement of more than 1.5% relative to the baseline unit, with a manageable pressure drop of 2.0−2.5 in. of water column. These results demonstrate that the catalyst-assisted approach can effectively eliminate CO emissions and improve energy efficiency. The technology has broad applicability for residential and commercial gas-fired heating systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Host turbine heat transfer overview

Improved methods of predicting airfoil local metal temperatures require advances in the understanding of the physics and methods of analytically predicting the following four aerothermal loads: hot gas flow over airfoils, heat transfer rates on the gas-side of airfoils, cooling air flow inside airfoils, and heat transfer rates on the coolant-side of airfoils. A systematic building block research approach is being pursued to investigate these four areas of concern from both the experimental and analytical sides. Experimental approaches being pursued start with fundamental experiments using simple shapes and flat plates in wind tunnels, progress to more realistic cold and hot cascade tests using airfoils, continue to progress in large low-speed rigs and turbines and warm turbines, and finally, combine all the interactive effects in tests using real engines or real engine type turbine rigs. Analytical approaches being pursued also build from relatively simple steady two dimensional inviscid flow and boundary layer heat transfer codes to more advanced steady two and three dimensional viscous flow and heat transfer codes. These advanced codes provide more physics to model better the interactive effects and the true real-engine environment.

Rohde, J. E.↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric Converter for Loop Heat Pipe Temperature Control: Experience and Lessons Learned

This paper describes the theoretical background and implementation methodology of using a thermoelectric converter (TEC) for operating temperature control of a loop heat pipe (LHP). In particular, experimental results from ambient and thermal vacuum tests of an LHP are presented for illustrations. The most commonly used state-of-the-art method to control the LHP operating temperature is to cold bias its compensation chamber (CC) and use an electrical heater to maintain the CC at the desired set point temperature. Although effective, this approach has its shortcomings in that the electrical heater can only provide heating to the CC, and the required power can be large under certain conditions. An alternative method is to use a TEC, which is capable of providing both heating and cooling to the CC. In this method, one side of the TEC is attached to the CC, and the other side is connected to the evaporator via a thermal strap. Using a bipolar power supply and a control algorithm, a TEC can function as a heater or a cooler, depending on the direction of the current flow. Extensive ground tests of several LHPs have demonstrated that a TEC can provide very tight temperature control for the CC. It also offers several additional advantages: (1) The LHP can operate at temperatures below its natural operating temperature at low heat loads; (2) The required heater power for a TEC is much less than that for an electrical heater; and (3) It enhances the LHP start-up success. Although the concept of using a TEC for LHP temperature control is simple, there are many factors to be considered in its implementation for space applications because the TEC is susceptible to the shear stress and yet has to sustain the dynamic load under the spacecraft launch environment. The added features that help the TEC to withstand the dynamic load will inevitably affect the TEC thermal performance. Some experiences and lessons learned are addressed in this paper.

Ku, Jentung↗

Temperature-induced densification in compressed basaltic glass revealed by in-situ ultrasonic measurements

Abstract Acoustic velocities of a model basalt glass (64 mol% CaMgSi2O6 + 36 mol% CaAl2Si2O8) were measured along different pressure-temperature (P-T) paths. One set of experiments involved isothermal compression-decompression cycles, performed at temperatures of 300, 641, 823, and 1006 K and pressures up to 12.2 GPa. The other set of experiments involved constant-load heating-cooling cycles at temperatures up to 823 K and pressures up to 7.5 GPa. Both sets of experiments were performed in a multi-anvil apparatus using a synchrotron-based ultrasonic technique. Our results show that the glass compressed isothermally at 300 K (cold-compression) displays anomalously decreasing compressional (VP) and shear (VS) wave velocities with increasing pressure until ~8 GPa. Beyond 8 GPa, both VP and VS start to increase sharply with pressure and irreversible densification of the glass occurred, producing large hysteresis loops of velocities upon decompression. However, for the glass compressed isothermally at increasingly higher temperatures (hot-compression), the velocity minima gradually shift to lower pressures. At temperature close to the glass transition temperature Tg, the velocity minima disappear completely, displaying a monotonic increase of velocities during compression and higher VP and VS during decompression. In addition, constant-load heating-cooling experiments show that velocities generally decrease slightly with increasing temperature, but start to increase once heated above a threshold temperature (~650 K). During cooling the velocities increase almost linearly with decreasing temperature, resulting in higher velocities (~1.5–2.5% higher) when returned to 300 K. This implies that a temperature-induced densification may have occurred in the glass at high pressures. Raman spectra on recovered samples show that the hot-compressed and high-P heated glasses contain distinctly densified and depolymerized structural signatures compared to the initial glass and the cold-compressed glass below the velocity transition pressure PT (~8 GPa). Such densification may be attributed to the breaking of bridging oxygen bonds and compaction in the intermediate-range structure. Our results demonstrate that temperature can facilitate glass densification at high pressures and point out the importance of P-T history in understanding the elastic properties of silicate glasses. Comparison with melt velocity suggests that hot-compressed glasses may better resemble the pressure dependence of velocity of silicate melts than cold-compressed glasses, but still show significantly higher velocities than melts. If the abnormal acoustic behaviors of cold-compressed glasses were used to constrain melt fractions in the mantle low-velocity regions, the melt fractions needed to explain a given velocity reduction would be significantly underestimated at high pressures.

Geochemistry & Geophysics↗

Effect of framework Al pairing on NO storage properties of Pd-CHA passive NOx adsorbers

For this study, three Pd/H-CHA samples were prepared containing 53.0%, 10.8% and 6.5% paired Al sites at near fixed Si/Al ratio and similar Pd loading. According to H 2 temperature-programmed reduction, Pd was present almost exclusively as isolated cations in the two samples containing the higher concentrations of paired Al sites, whereas in the other sample PdO was also present. Simulated lean cold start tests on the fresh samples conducted in a microflow reactor showed that the sample containing PdO stored the lowest amount of NOx. When tested with CO/H 2 , the sample containing 53.0% paired Al sites showed significantly better storage capacity than the other samples and deactivated less rapidly upon sequential tests. Experiments using lean gasoline engine exhaust revealed similar trends. This study showed that a high concentration of paired Al sites in Pd/H-CHA is beneficial for NOx storage capacity, thermal durability, and minimizing deactivation in the presence of CO/H 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propulsion System Testing for the Iodine Satellite (iSAT) Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (less than 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. An iodine-based system is not without its challenges. The primary challenge is that the entire feed system must be maintained at an elevated temperature to prevent the iodine from depositing (transitioning from the gas phase directly back into the solid phase), which will block the propellant feed lines. Furthermore, deposition will occur unless the temperature in the lines is not greater than the temperature of the propellant reservoir. The flow rate can be controlled by adjusting the heating applied to the reservoir, but as with any thermal control there is a relatively slow response to changes in the heating rate. In the present paper, we describe the propulsion and propellant feed system for the iodine satellite (iSAT) flight demonstration mission. The system is based around the Busek BHT-200 Hall thruster, which has been modified for chemical compatibility with iodine vapor. While the gross propellant flow rate is maintained by the heated propellant reservoir, the flow to the anode and cathode are adjusted using two heated Vacco proportional flow control valves (PFCV), which provide very fast response on the flow rate adjustment. The flight mission design layout will be presented, showing how the system will be packaged into the overall 12-U spacecraft and the techniques being employed to protect the remaining spacecraft hardware from the propulsion system (e.g., plasma impingement, iodine deposition, thermal loads). In addition to the flight system design, results of testing the thruster and cathode with both operating on iodine propellant are presented. The tests are conducted on a thrust stand (see Fig. 1) in a large vacuum chamber containing a beam dump chilled to below -100 C to 'cryopump' the propellant. The thruster performance during these tests is presented, with these data used to evaluate the feed system and guide further refinements. Results of relatively long duration testing are presented to demonstrate the capability to operate for the length of the iSAT mission and to perform a number of re-starts as will be required by the mission concept of operations.

Polzin, Kurt A.↗