Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

A model of flow in a closed-loop thermosyphon including the Soret effect

This theoretical study addresses the nature of convective motions in a toroidal loop of binary fluid oriented in the vertical plane and heated from below. The boundaries of the loop are impermeable, but gradients of the solute can be set up by Soret diffusion in the direction around the loop. The existence and stability of steady solutions are discussed over the Rayleigh number-Soret coefficient parameter plane. When the Soret coefficient is negative, periodic and chaotic oscillations analogous to those of thermohaline convection are predicted. When the Soret coefficient is positive, relaxation oscillations and low Rayleigh number chaotic motions are found. Both sets of phenomena are predicted to occur for realistic thermosyphon parameters.

Hart, J. E.↗

A note on the loop thermosyphon with mixed boundary conditions

This paper presents a one-dimensional model for flow in a toroidal fluid loop in which the wall heat transfer coefficient is constant over one half of the loop, and zero over the other. A mathematically low-dimensional form of the model gives reasonably accurate predictions of the steady state mass flow, stability, and the nature of nonsteady motions. Numerical computations with a high-dimensional model illustrate the effects of mixed boundaries and axial heat conduction on the chaotic solutions. Comparisons are made with previous low-dimensional models that are exact only for a spatially uniform heat transfer coefficient.

Hart, J. E.↗

Liquid-cooling technology for gas turbines - Review and status

After a brief review of past efforts involving the forced-convection cooling of gas turbines, the paper surveys the state of the art of the liquid cooling of gas turbines. Emphasis is placed on thermosyphon methods of cooling, including those utilizing closed, open, and closed-loop thermosyphons; other methods, including sweat, spray and stator cooling, are also discussed. The more significant research efforts, design data, correlations, and analytical methods are mentioned and voids in technology are summarized.

Van Fossen, G. J., Jr.↗

Simulation of natural circulation cartridge loop experiments and application to molten salt reactors

This work uses the TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics (TH) code to model natural circulation cartridge loop experiments previously conducted at Oak Ridge National Laboratory (ORNL) using water and compares the simulated and experimental results. TRACE is also used to characterize natural circulation in the cartridge loop vehicle using FLiNaK as the working fluid. The experimental vehicle is a buoyancy-aided, annular cartridge loop, referred to as a thermosyphon, and is designed to aid in qualifying liquid–fueled and/or liquid–cooled irradiation experiments for the Versatile Test Reactor (VTR), which is currently being designed in the United States. Out-of-pile water experiments have been conducted using the cartridge and the Thermosyphon Test Loop facility at ORNL, and future experiments are anticipated that would use other molten salt surrogates as the working fluid, followed by eventual insertion of a similar cartridge into VTR. Additionally, this work aims to determine how well TRACE can replicate the natural convection conditions that were observed experimentally; this serves as an initial step for validating the modeling tool for design and safety calculations to support future irradiation experiments in VTR. Initial predictions of potential experiments were made using FLiNaK as the natural circulation fluid to demonstrate the relevance of the cartridge design to molten salt reactors (MSRs). Results from this study indicate that TRACE can accurately capture natural convection phenomena in the thermosyphon and that several design changes to the current cartridge vehicle are necessary to achieve hydraulic conditions similar to those expected in MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Interface Evaluation of Heat Transfer from a Pumped Loop to Titanium-Water Thermosyphons

Titanium-water thermosyphons are being considered for use in the heat rejection system for lunar outpost fission surface power. Key to their use is heat transfer between a closed loop heat source and the heat pipe evaporators. This work describes laboratory testing of several interfaces that were evaluated for their thermal performance characteristics, in the temperature range of 350 to 400 K, utilizing a water closed loop heat source and multiple thermosyphon evaporator geometries. A gas gap calorimeter was used to measure heat flow at steady state. Thermocouples in the closed loop heat source and on the evaporator were used to measure thermal conductance. The interfaces were in two generic categories, those immersed in the water closed loop heat source and those clamped to the water closed loop heat source with differing thermal conductive agents. In general, immersed evaporators showed better overall performance than their clamped counterparts. Selected clamped evaporator geometries offered promise.

Jaworske, Donald A.↗

Testing and Simulation of an Updated Cartridge Loop Vehicle

The Versatile Test Reactor (VTR) is a sodium-cooled, fast-spectrum test reactor that is being developed in the United States and will support a variety of irradiation test vehicle configurations, including cartridge loops. This work includes out-of-pile experimental results from a single-phase, natural circulation cartridge loop vehicle with geometry relevant to VTR irradiation sites, as well as comparisons between the experimental results and results predicted using the TRAC/RELAP Advanced Computational Engine (TRACE) modeling tool. The experiments were conducted in the thermosyphon test loop (TSTL) facility at Oak Ridge National Laboratory. Comparisons are also made between the current experimental data and results from natural circulation experiments previously conducted in the TSTL in a cartridge vehicle that is similar in design but has smaller flow areas. This cartridge vehicle and the experimental program were developed to add to the single-phase, natural circulation data collected in the previous iteration of the cartridge loop design, which supports future irradiation experiments and adds to a database that is useful for validating computer models. Comparisons of experimental results to TRACE model predictions is a pertinent step in validating the computational tool for supporting future irradiation experiment design and safety calculations, and comparisons to previous cartridge loop results highlight the impact of the design changes made to the test vehicle. The experiments conducted include several steady state tests and transients, including power ramp, loss of offsite power, and loss of external flow scenarios. This work shows that TRACE can accurately predict temperatures and flow conditions in the cartridge loop and the updated vehicle design achieves higher mass flow rates at the same steady state power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermosyphon heat exchanger

Report summarizes final development, testing, and certification of pumpless, liquid-to-air heat exchanger for solar heating. System requires blower but no pump in water loop. Output is 35,000 Btu/hr when water temperature is 49 C.

Hankins, J. D.↗

Thermosyphon Suspension For Growth Of Crystals

Thermosyphon provides gentle convective flow of supersaturated solution that both suspends and contributes material to growing crystal. Apparatus includes heating section, cooling section, and expansion-and-growth chamber in closed flow loop. Intended for growth of protein crystals, so fragile they are easily damaged by high-shear flows produced by pumps.

Nyce, Thomas A.↗

Heat Pipes and Heat Rejection Component Testing at NASA Glenn Research Center

Titanium-water heat pipes are being evaluated for use in the heat rejection system for space fission power systems. The heat rejection syst em currently comprises heat pipes with a graphite saddle and a composite fin. The heat input is a pumped water loop from the cooling of the power conversion system. The National Aeronautics and Space Administration has been life testing titanium-water heat pipes as well as eval uating several heat pipe radiator designs. The testing includes thermal modeling and verification of model, material compatibility, frozen startup of heat pipe radiators, and simulating low-gravity environments. Future thermal testing of titanium-water heat pipes includes low-g ravity testing of thermosyphons, radiation testing of heat pipes and fin materials, water pump performance testing, as well as Small Busine ss Innovation Research funded deliverable prototype radiator panels.

Sanzi, James L.↗