Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Liquid detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442

Determining Optimal Running Conditions for TinyTPC Detector

Liquid argon time projection chambers, (LArTPCs), are particle detectors used to collect ionization charge information from particle trajectories, facilitating detailed particle track analysis. They are currently used as particle detectors in major physics projects such as the deep underground neutrino experiment (DUNE), to detect and study the nature of the elusive neutrino particle. TinyTPC is a small scale LArTPC featuring a pixelated readout system (LArPix) that we will use to study liquid argon doping. We expect this doping to enhance the resolution of LAr detectors, especially for low energy particles below 10 MeV which would expand the capabilities of currently running experiments. Housed within a cryostat filled with liquid argon, the TinyTPC will rely on a high and a low voltage system to collect data. In preparation for deployment we found and resolved issues in the HV and LV systems and we determined optimal running conditions in a test vessel. This presentation will go over the detector commissioning process that enabled data taking with the TinyTPC.

Gonzalez, Rebecca

Anapole moment of neutrinos and radioactive sources near liquid xenon detectors

We show that placing a radioactive source such as 51 Cr near a liquid xenon detector may allow us to detect the contribution induced by the anapole moment to neutrino-electron scattering in the Standard Model (SM) at the 1 − 2⁢𝜎 level. Although the anapole moment of neutrinos induces a scattering rate with the same spectral shape as the neutral and charged current contributions, exposures of ∼ 60 ton × source run at XENONnT or XLZD may be enough to accumulate sufficient statistics for a detection. We also discuss a simple model where the anapole moment of neutrinos is enhanced or decreased with respect to the SM expectation, further demonstrating how a potential measurement of the anapole moment of neutrinos would allow us to constrain new physics.

dark matter direct detection

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are a new class of detector materials that provide efficient and tunable detection of both Cherenkov and scintillation light. A massive WbLS neutrino detector with suitable photosensor coverage for low intensity light detection could therefore reconstruct the momentum of an energetic charged particle and also have enhanced low-energy sensitivity. These materials are also better suited for metal doping broadening the potential scientific utility. Here, we recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition and calibration system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early results.

47 OTHER INSTRUMENTATION

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator

Intelligent Triggers for Rare Event Detection in Liquid Argon Detectors

Next-generation neutrino experiments like SBND and DUNE rely on Liquid Argon Time Projection Chambers (LArTPCs), which produce exceptionally detailed data at high volume. Capturing rare or unexpected events in real-time is a major challenge. Our project explores the use of machine learning, specifically autoencoder-based anomaly detection, to identify unusual activity directly from raw detector signals. Inspired by successes at the CMS experiment, we demonstrate that such methods can be adapted to LArTPCs and show promising results in both simulated studies and early steps toward real-time hardware deployment. This approach could open new avenues for detecting signals from physics beyond the Standard Model.

Chung, Seokju [Columbia U. (main)]

DUNE Phase II: scientific opportunities, detector concepts, technological solutions

The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the European Strategy for Particle Physics. While the construction of the DUNE Phase I is well underway, this White Paper focuses on DUNE Phase II planning. DUNE Phase-II consists of a third and fourth far detector (FD) module, an upgraded near detector complex, and an enhanced 2.1 MW beam. The fourth FD module is conceived as a “Module of Opportunity”, aimed at expanding the physics opportunities, in addition to supporting the core DUNE science program, with more advanced technologies. This document highlights the increased science opportunities offered by the DUNE Phase II near and far detectors, including long-baseline neutrino oscillation physics, neutrino astrophysics, and physics beyond the standard model. It describes the DUNE Phase II near and far detector technologies and detector design concepts that are currently under consideration. A summary of key R&D goals and prototyping phases needed to realize the Phase II detector technical designs is also provided. DUNE's Phase II detectors, along with the increased beam power, will complete the full scope of DUNE, enabling a multi-decadal program of groundbreaking science with neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION

Gamma Ray Detection In Liquid Argon Time Projection Chambers

Gamma rays are photons in excess of 100 keV of energy and can be produced by a variety of mechanisms like radioactive decay and inelastic neutrino-argon interactions. A reconstruc- tion of Compton scattering gamma rays was developed for use in liquid argon time projection chambers. This reconstruction was tested with detectors developed to demonstrate the ca- pabilities of Deep Underground Neutrino Experiment (DUNE) Near Detector Liquid Argon target (ND LAr). In October 2024, a radioactive fluorine-18 source was placed next to the Full Scale Demonstrator. The data obtained was used to test this reconstruction algorithm. It was able to determine the direction of the photons with an error of less than 10 percent. In addition to this work, there has been significant work on designing a liquid argon based Positron Emission Tomography (PET) scanner. PET scanners detect gamma rays emitted by a tracer chemical to help screen for diseases like cancer. In addition to the applications to medical imaging, this thesis briefly explores the applications of this reconstruction to de-excitation photons produced in interactions between neutrinos and argon nuclei. These applications could improve studies focusing on neutrinos originating from accelerators and supernovae.

Murphy, Thomas [Syracuse U.]

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors

Characterization of UV optical components for photon detector calibration in liquid argon TPCs

Large liquid argon time projection chambers (LArTPCs)require stable and well-characterized delivery of ultraviolet (UV)light for in situ calibration of photosensors at cryogenictemperatures. This article reports bench-top and cryogenicmeasurements of the optical components used in a UV lightcalibration system, including multi-mode fused-silica fibers,SMA-to-SMA connectors, optical fiber feedthroughs, andlight-diffuser assemblies. Light loss in several fiber types and SMAconnectors was measured across wavelengths from275–970 mm. In addition,light-loss measurements of the tested fibers after severalliquid-nitrogen thermal cycles showed no statistically significantdegradation relative to baseline measurements, and high-rate pulsedexposure (30–90 million pulses from a275 nm LED) likewise showed nomeasurable aging in jacketed fibers. A compact, palm-sized,3D-printed PEEK diffuser housing with stacked UV-grade fused-silicadiffusers yields Lambertian emission and the most uniform angulardistribution. Optical components exhibiting improved UV transmissionwere deployed successfully in multiple DUNE small- and large-scaleprototypes, demonstrating reliable operation of UV light calibrationsystem. These findings inform component selection and calibrationprocedures for achieving reliable, uniform UV light delivery inlarge-scale cryogenic detectors such as DUNE.

Behera, B. [South Dakota Sch. Mines Tech.] (ORCID:

Electromagnetic shower reconstruction in the ICARUS liquid argon time projection chamber detector

The ICARUS-T600 liquid argon time projection chamber (LArTPC) detector is taking data at shallow depth as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab, to search for a possible sterile neutrino signal at $\Delta m^{2} \approx 1~\text{eV}^{2}$ with the Booster (BNB) and Main Injector (NuMI) neutrino beams at $\GeV{\sim 0.8}$ and $\GeV{\sim 2}$ average energies respectively. The LArTPC technology, developed by the ICARUS collaboration and now a standard in neutrino physics, offers impressive charged-particle imaging capabilities with $\sim1 \ \text{mm}$ spatial resolution, enabling efficient discrimination between track-like signatures (e.g., from muons, pions, and protons) and electromagnetic showers (from electrons and photons). Moreover, electron and photon signatures can be distinguished both with the calorimetric measurement of local energy depositions at the shower start and with the cm-scale conversion gap signature of photons. This contribution discusses event reconstruction at ICARUS focusing on Pandora, a multi-algorithm pattern recognition software widely used in LArTPC experiments. Over a hundred Pandora algorithms and tools are used to reconstruct cosmic rays and neutrino interactions in the ICARUS detector. Recent developments have focused on the reconstruction of electromagnetic shower signatures, crucial to ensure a robust and efficient reconstruction of charged-current $\nu_e$ interactions, which serve as a key signature of sterile neutrino oscillations at SBN. In this contribution, recent improvements to the reconstruction are discussed, focusing on the discrimination between tracks and electromagnetic showers using neutrino simulations and data.

Triozzi, Riccardo [Padua U.; INFN, Padua] (ORCID:0

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors

Fiber-coupled digital photo sensors for large Time Projection Chambers

Here, this paper presents a novel approach to addressing challenges in neutrino event reconstruction within large Time Projection Chambers (TPCs). By integrating fiber-coupled digital silicon photomultipliers, we propose a design that enhances light detection and improves both energy resolution and event reconstruction. Advancements in power and signal over fiber technologies are leveraged to deploy digital sensors within the TPC bulk volume, enabling precise timing and robust particle identification.

47 OTHER INSTRUMENTATION