Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linear Energy Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

S-Phase Cells Are More Sensitive to High-Linear Energy Transfer Radiation

Purpose: S-phase cells are more resistant to low-linear energy transfer (LET) ionizing radiation (IR) than nonsynchronized and G{sub 1}-phase cells, because both nonhomologous end-joining (NHEJ) and homologous recombination repair can repair DNA double-strand breaks (DSBs) in the S phase. Although it was reported 3 decades ago that S-phase cells did not show more resistance to high-LET IR than cells in other phases, the mechanism remains unclear. We therefore attempted to study the phenotypes and elucidate the mechanism involved. Methods and Materials: Wild-type and NHEJ-deficient cell lines were synchronized using the double-thymidine approach. A clonogenic assay was used to detect the sensitivity of nonsynchronized, synchronized S-phase, and G{sub 2}-phase cells to high- and low-LET IR. The amounts of Ku bound to DSBs in the high- and low-LET-irradiated cells were also examined. Results: S-phase wild-type cells (but not NHEJ-deficient cells) were more sensitive to high-LET IR than nonsynchronized and G{sub 2}-phase cells. In addition, S-phase wild-type cells showed less efficient Ku protein binding to DSBs than nonsynchronized and G{sub 2}-phase cells in response to high-LET IR, although all cells at all phases showed similarly efficient levels of Ku protein binding to DSBs in response to low-LET IR. Conclusions: S-phase cells are more sensitive to high-LET IR than nonsynchronized and G{sub 2}-phase cells, because of the following mechanism: it is more difficult for Ku protein to bind to high-LET IR-induced DNA DSBs in S-phase cells than in cells at other phases, which results in less efficient NHEJ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Genomic stability in response to high versus low linear energy transfer radiation in Arabidopsis thaliana

Low linear energy transfer (LET) gamma rays and high LET HZE (high atomic weight, high energy) particles act as powerful mutagens in both plants and animals. DNA damage generated by HZE particles is more densely clustered than that generated by gamma rays. To understand the genetic requirements for resistance to high versus low LET radiation, a series of Arabidopsis thaliana mutants were exposed to either 1GeV Fe nuclei or gamma radiation. A comparison of effects on the germination and subsequent growth of seedlings led us to conclude that the relative biological effectiveness (RBE) of the two types of radiation (HZE versus gamma) are roughly 3:1. Similarly, in wild-type lines, loss of somatic heterozygosity was induced at an RBE of about a 2:1 (HZE versus gamma). Checkpoint and repair defects, as expected, enhanced sensitivity to both agents. The “replication fork” checkpoint, governed by ATR, played a slightly more important role in resistance to HZE-induced mutagenesis than in resistance to gamma induced mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-78: Comparison of Dose-Averaged Linear Energy Transfer Calculation Methods Used in Monte Carlo Simulations of Clinical Proton Beams

Purpose: To evaluate the differences in dose-averaged linear energy transfer (LETd) maps calculated in water by means of different strategies found in the literature in proton therapy Monte Carlo simulations and to compare their values with dose-mean lineal energy microdosimetry calculations. Methods: The Geant4 toolkit (version 9.6.2) was used. Dose and LETd maps in water were scored for primary protons with cylindrical voxels defined around the beam axis. Three LETd calculation methods were implemented. First, the LETd values were computed by calculating the unrestricted linear energy transfer (LET) associated to each single step weighted by the energy deposition (including delta-rays) along the step. Second, the LETd was obtained for each voxel by computing the LET along all the steps simulated for each proton track within the voxel, weighted by the energy deposition of those steps. Third, the LETd was scored as the quotient between the second momentum of the LET distribution, calculated per proton track, over the first momentum. These calculations were made with various voxel thicknesses (0.2 – 2.0 mm) for a 160 MeV proton beamlet and spread-out Bragg Peaks (SOBP). The dose-mean lineal energy was calculated in a uniformly-irradiated water sphere, 0.005 mm radius. Results: The value of the LETd changed systematically with the voxel thickness due to delta-ray emission and the enlargement of the LET distribution spread, especially at shallow depths. Differences of up to a factor 1.8 were found at the depth of maximum dose, leading to similar differences at the central and distal depths of the SOBPs. The third LETd calculation method gave better agreement with microdosimetry calculations around the Bragg Peak. Conclusion: Significant differences were found between LETd map Monte Carlo calculations due to both the calculation strategy and the voxel thickness used. This could have a significant impact in radiobiologically-optimized proton therapy treatments.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRD-14: Dose Weighted Linear Energy Transfer Analysis of Critical Structures in Proton Therapy of Pediatric Brain Tumor Patients

Purpose: Dose weighted Linear Energy Transfer (LETd) analysis of critical structures may be useful in understanding the side effects of the proton therapy. The objective is to analyze the differences between LETd and dose distributions in brain tumor patients receiving double scattering proton therapy, to quantify LETd variation in critical organs, and to identify beam arrangements contributing to high LETd in critical organs. Methods: Monte Carlo simulations of 9 pediatric brain tumor patients were performed. The treatment plans were reconstructed with the TOPAS Monte Carlo code to calculate LETd and dose. The beam data were reconstructed proximal to the aperture of the double scattering nozzle. The dose and LETd to target and critical organs including brain stem, optic chiasm, lens, optic nerve, pituitary gland, and hypothalamus were computed for each beam. Results: Greater variability in LETd compared to dose was observed in the brainstem for patients with a variety of tumor types including 5 patients with tumors located in the posterior fossa. Approximately 20%–44% brainstem volume received LETd of 5kev/µm or greater from beams within gantry angles 180°±30° for 5 patients treated with a 3 beam arrangement. Critical organs received higher LETd when located in the vicinity of the beam distal edge. Conclusion: This study presents a novel strategy in the evaluation of the proton treatment impact on critical organs. While the dose to critical organs is confined below the required limits, the LETd may have significant variation. Critical organs in the vicinity of beam distal edge receive higher LETd and depended on beam arrangement, e.g. in posterior fossa tumor treatment, brainstem receive higher LETd from posterior-anterior beams. This study shows importance of the LETd analysis of the radiation impact on the critical organs in proton therapy and may be used to explain clinical imaging observations after therapy.

60 APPLIED LIFE SCIENCES↗

What is the Clinically Relevant Relative Biologic Effectiveness? A Warning for Fractionated Treatments With High Linear Energy Transfer Radiation

Purpose: To study the clinically relevant relative biologic effectiveness (RBE) of fractionated treatments with high linear energy transfer (LET) radiation and to identify the important factors that might influence the transfer of tolerance and curative levels from low LET radiation. These are important questions in the light of the growing interest for the therapeutic use of radiation with higher LET than electrons or photons. Methods and Materials: The RBE of various fractionated schedules was analyzed with theoretical models for radiation effect, and the resulting predictions were compared with the published clinical and experimental data regarding fractionated irradiation with high LET radiation. Results: The clinically relevant RBE increased for greater doses per fraction, in contrast to the predictions from single-dose experiments. Furthermore, the RBE for late-reacting tissues appeared to modify more quickly than that for early-reacting tissues. These aspects have quite important clinical implications, because the increased biologic effectiveness reported for this type of radiation would otherwise support the use of hypofractionation. Thus, the differential between acute and late-reacting tissues could put the late-reacting normal tissues at more risk from high LET irradiation; however, at the same time, it could increase the therapeutic window for slow-growing tumors. Conclusions: The modification of the RBE with the dose per fraction must be carefully taken into consideration when devising fractionated treatments with high LET radiation. Neglecting to do so might result in an avalanche of complications that could obscure the potential advantages of the therapeutic use of this type of radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variations in Linear Energy Transfer Within Clinical Proton Therapy Fields and the Potential for Biological Treatment Planning

Purpose: To calculate the linear energy transfer (LET) distributions in patients undergoing proton therapy. These distributions can be used to identify areas of elevated or diminished biological effect. The location of such areas might be influenced in intensity-modulated proton therapy (IMPT) optimization. Methods and Materials: Because Monte Carlo studies to investigate the LET distribution in patients have not been undertaken so far, the code is first validated with simulations in water. The code was used in five patients, for each of them three planning and delivery techniques were simulated: passive scattering, three-dimensional modulation IMPT (3D-IMPT), and distal edge tracking IMPT (DET-IMPT). Results: The inclusion of secondary particles led to significant differences compared with analytical techniques. In addition, passive scattering and 3D-IMPT led to largely comparable LET distributions, whereas the DET-IMPT plans resulted in considerably increased LET values in normal tissues and critical structures. In the brainstem, dose-averaged LET values exceeding 5 keV/{mu}m were observed in areas with significant dose (>70% of prescribed dose). In noncritical normal tissues, even values >8 keV/{mu}m occurred. Conclusion: This work demonstrates that active scanning offers the possibility of influencing the distribution of dose-averaged LET (i.e., the biological effect) without significantly altering the distribution of physical dose. On the basis of this finding, we propose a method to alter deliberately the LET distribution of a treatment plan in such a manner that the LET is maximized within certain target areas and minimized in normal tissues, while maintaining the prescribed target dose and dose constraints for organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.

60 APPLIED LIFE SCIENCES↗

Reoptimization of Intensity Modulated Proton Therapy Plans Based on Linear Energy Transfer

Purpose: We describe a treatment plan optimization method for intensity modulated proton therapy (IMPT) that avoids high values of linear energy transfer (LET) in critical structures located within or near the target volume while limiting degradation of the best possible physical dose distribution. Methods and Materials: To allow fast optimization based on dose and LET, a GPU-based Monte Carlo code was extended to provide dose-averaged LET in addition to dose for all pencil beams. After optimizing an initial IMPT plan based on physical dose, a prioritized optimization scheme is used to modify the LET distribution while constraining the physical dose objectives to values close to the initial plan. The LET optimization step is performed based on objective functions evaluated for the product of LET and physical dose (LET×D). To first approximation, LET×D represents a measure of the additional biological dose that is caused by high LET. Results: The method is effective for treatments where serial critical structures with maximum dose constraints are located within or near the target. We report on 5 patients with intracranial tumors (high-grade meningiomas, base-of-skull chordomas, ependymomas) in whom the target volume overlaps with the brainstem and optic structures. In all cases, high LET×D in critical structures could be avoided while minimally compromising physical dose planning objectives. Conclusion: LET-based reoptimization of IMPT plans represents a pragmatic approach to bridge the gap between purely physical dose-based and relative biological effectiveness (RBE)-based planning. The method makes IMPT treatments safer by mitigating a potentially increased risk of side effects resulting from elevated RBE of proton beams near the end of range.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

System for measuring temporal profiles of scintillation at high and different linear energy transfers by using pulsed ion beams

We have developed a system for measuring the temporal profiles of scintillation at high linear energy transfer (LET) by using pulsed ion beams from a cyclotron. The half width at half maximum time resolution was estimated to be 1.5–2.2 ns, which we attributed mainly to the duration of the pulsed ion beam and timing jitter between the trigger signal and the arrival of the ion pulse. The temporal profiles of scintillation of BaF{sub 2} at different LETs were successfully observed. These results indicate that the proposed system is a powerful tool for analyzing the LET effects in temporal profiles of scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster — Thur Eve — 45: Comparison of different Monte Carlo methods of scoring linear energy transfer in modulated proton therapy beams

In this work, we demonstrate inconsistencies in commonly used Monte Carlo methods of scoring linear energy transfer (LET) in proton therapy beams. In particle therapy beams, the LET is an important parameter because the relative biological effectiveness (RBE) depends on it. LET is often determined using Monte Carlo techniques. We used a realistic Monte Carlo model of a proton therapy nozzle to score proton LET in spread-out Bragg peak (SOBP) depth-dose distributions. We used three different scoring and calculation techniques to determine average LET at varying depths within a 140 MeV beam with a 4 cm SOBP and a 250 MeV beam with a 10 cm SOBP. These techniques included fluence-weighted (Φ-LET) and dose-weighted average (D-LET) LET calculations from: 1) scored energy spectra converted to LET spectra through a lookup table, 2) directly scored LET spectra and 3) accumulated LET scored ‘on-the-fly’ during simulations. All protons (primary and secondary) were included in the scoring. Φ-LET was found to be less sensitive to changes in scoring technique than D-LET. In addition, the spectral scoring methods were sensitive to low-energy (high-LET) cutoff values in the averaging. Using cutoff parameters chosen carefully for consistency between techniques, we found variations in Φ-LET values of up to 1.6% and variations in D-LET values of up to 11.2% for the same irradiation conditions, depending on the method used to score LET. Variations were largest near the end of the SOBP, where the LET and energy spectra are broader.

07 ISOTOPE AND RADIATION SOURCES↗

Carbon Ion Irradiation of the Rat Spinal Cord: Dependence of the Relative Biological Effectiveness on Linear Energy Transfer

Purpose: To measure the relative biological effectiveness (RBE) of carbon ions in the rat spinal cord as a function of linear energy transfer (LET). Methods and Materials: As an extension of a previous study, the cervical spinal cord of rats was irradiated with single doses of carbon ions at 6 positions of a 6-cm spread-out Bragg peak (16-99 keV/μm). The TD{sub 50} values (dose at 50% complication probability) were determined according to dose-response curves for the development of paresis grade 2 within an observation time of 300 days. The RBEs were calculated using TD{sub 50} for photons of our previous study. Results: Minimum latency time was found to be dose-dependent, but not significantly LET-dependent. The TD{sub 50} values for the onset of paresis grade 2 within 300 days were 19.5 ± 0.4 Gy (16 keV/μm), 18.4 ± 0.4 Gy (21 keV/μm), 17.7 ± 0.3 Gy (36 keV/μm), 16.1 ± 1.2 Gy (45 keV/μm), 14.6 ± 0.5 Gy (66 keV/μm), and 14.8 ± 0.5 Gy (99 keV/μm). The corresponding RBEs increased from 1.26 ± 0.05 (16 keV/μm) up to 1.68 ± 0.08 at 66 keV/μm. Unexpectedly, the RBE at 99 keV/μm was comparable to that at 66 keV/μm. Conclusions: The data suggest a linear relation between RBE and LET at high doses for late effects in the spinal cord. Together with additional data from ongoing fractionated irradiation experiments, these data will provide an extended database to systematically benchmark RBE models for further improvements of carbon ion treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiobiologic Parameters and Local Effect Model Predictions for Head-and-Neck Squamous Cell Carcinomas Exposed to High Linear Energy Transfer Ions

Purpose: To establish the radiobiologic parameters of head-and-neck squamous cell carcinomas (HNSCC) in response to ion irradiation with various linear energy transfer (LET) values and to evaluate the relevance of the local effect model (LEM) in HNSCC. Methods and Materials: Cell survival curves were established in radiosensitive SCC61 and radioresistant SQ20B cell lines irradiated with [33.6 and 184 keV/n] carbon, [302 keV/n] argon, and X-rays. The results of ion experiments were confronted to LEM predictions. Results: The relative biologic efficiency ranged from 1.5 to 4.2 for SCC61 and 2.1 to 2.8 for SQ20B cells. Fixing an arbitrary D{sub 0} parameter, which characterized survival to X-ray at high doses (>10 Gy), gave unsatisfying LEM predictions for both cell lines. For D{sub 0} = 10 Gy, the error on survival fraction at 2 Gy amounted to a factor of 10 for [184 keV/n] carbon in SCC61 cells. We showed that the slope (s{sub max}) of the survival curve at high doses was much more reliable than D{sub 0}. Fitting s{sub max} to 2.5 Gy{sup -1} gave better predictions for both cell lines. Nevertheless, LEM could not predict the responses to fast and slow ions with the same accuracy. Conclusions: The LEM could predict the main trends of these experimental data with correct orders of magnitude while s{sub max} was optimized. Thus the efficiency of carbon ions cannot be simply extracted from the clinical response of a patient to X-rays. LEM should help to optimize planning for hadrontherapy if a set of experimental data is available for high-LET radiations in various types of tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-201-03: A Real-Time Method to Simultaneously Measure Linear Energy Transfer and Dose for Proton Therapy Using Organic Scintillators

Purpose: The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits the ionization quenching phenomenon to provide a method of measuring LET and auto correcting quenching. Methods: We exposed simultaneously four different organic scintillators (BCF-12, PMMA, PVT, and LSD; 1mm in diameter) and a plane parallel ionization chamber in passively scattered proton beams to doses between 32 and 43 cGy and fluence averaged LET values from 0.47 to 1.26 keV/µm. The LET values for each irradiation condition were determined using a validated Monte Carlo model of the beam line. We determined the quenching parameter in the Birk’s equation for scintillation in BCF-12 for dose measurements. One set of irradiation conditions was used to correlate the scintillation response ratio to the LET values and plot a scintillation response ratio versus LET calibration curve. Irradiation conditions independent from the calibration ones were used to validate this method. Comparisons to the expected values were made on both the basis of dose and LET. Results: Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation to LET values and was used as the LET calibration curve. The expected LET values in the validation set were within 2%±6%, which resulted in dose accuracy of 1.5%±5.8% for the range of LET values investigated in this work. Conclusion: We have demonstrated the feasibility of using the ratio between the light output of two organic scintillators to simultaneously measure LET and dose of therapeutic proton beams. Further studies are needed to verify the response in higher LET values.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-16: Relative Biological Effectiveness of Double-Strand Break Induction for Modeling Cell Survival in Pristine Proton Beams of Different Dose-Averaged Linear Energy Transfers

Purpose: High throughput in vitro experiments assessing cell survival following proton radiation indicate that both the alpha and the beta parameters of the linear quadratic model increase with increasing proton linear energy transfer (LET). We investigated the relative biological effectiveness (RBE) of double-strand break (DSB) induction as a means of explaining the experimental results. Methods: Experiments were performed with two lung cancer cell lines and a range of proton LET values (0.94 – 19.4 keV/µm) using an experimental apparatus designed to irradiate cells in a 96 well plate such that each column encounters protons of different dose-averaged LET (LETd). Traditional linear quadratic survival curve fitting was performed, and alpha, beta, and RBE values obtained. Survival curves were also fit with a model incorporating RBE of DSB induction as the sole fit parameter. Fitted values of the RBE of DSB induction were then compared to values obtained using Monte Carlo Damage Simulation (MCDS) software and energy spectra calculated with Geant4. Other parameters including alpha, beta, and number of DSBs were compared to those obtained from traditional fitting. Results: Survival curve fitting with RBE of DSB induction yielded alpha and beta parameters that increase with proton LETd, which follows from the standard method of fitting; however, relying on a single fit parameter provided more consistent trends. The fitted values of RBE of DSB induction increased beyond what is predicted from MCDS data above proton LETd of approximately 10 keV/µm. Conclusion: In order to accurately model in vitro proton irradiation experiments performed with high throughput methods, the RBE of DSB induction must increase more rapidly than predicted by MCDS above LETd of 10 keV/µm. This can be explained by considering the increased complexity of DSBs or the nature of intra-track pairwise DSB interactions in this range of LETd values. NIH Grant 2U19CA021239-35.

60 APPLIED LIFE SCIENCES↗

Mixed Effect Modeling of Dose and Linear Energy Transfer Correlations With Brain Image Changes After Intensity Modulated Proton Therapy for Skull Base Head and Neck Cancer

Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction and Persistence of Large γH2AX Foci by High Linear Energy Transfer Radiation in DNA-Dependent protein kinase–Deficient Cells

Purpose: To evaluate the cell response to DNA double-strand breaks induced by low and high linear energy transfer (LET) radiations when the catalytic subunit of DNA-dependent protein kinase (DNA-PKcs), an essential protein of the nonhomologous end-joining repair pathway, lacks kinase activity. Methods and Materials: CHO10B2, a Chinese hamster ovary cell line, and its derived radiosensitive mutant cell line, irs-20, lacking DNA-PKcs activity, were evaluated after 0 to 3 Gy of γ-rays, plateau and Bragg peak protons, and lithium beams by clonogenic assay, and as a measurement of double-strand breaks, phosphorylated H2AX (γH2AX) foci number and size were quantified by immunocytofluorescence. Results: Irs-20 exhibited greater radiosensitivity and a higher amount of γH2AX foci than CHO10B2 at 6 hours after irradiation for all types of radiations. Remarkably, CHO10B2 and irs-20 maintained their difference in radiosensitivity after high-LET radiation. Six hours after low-LET radiations, irs-20 did not reach basal levels of γH2AX at high doses, whereas CHO10B2 recovered basal levels for all doses. After high-LET radiation, only CHO10B2 exhibited a reduction in γH2AX foci, but it never reached basal levels. Persistent foci in irs-20 confirmed a repair deficiency. Interestingly, after 30 minutes of high-LET radiation both cell lines exhibited large foci (size >0.9 μm{sup 2}) related to the damage nature, whereas at 6 hours irs-20 showed a higher amount of large foci than CHO10B2, with a 7-fold increase at 3 Gy, that could also be associated to radiosensitivity. Conclusions: We demonstrated, for the first time, an association between deficient DNA-PKcs activity and not only high levels of H2AX phosphorylation but also persistence and size increase of γH2AX foci after high-LET irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗