The factors influencing the formation of Li2CO3 from LiOH and CO2

LiOH is used to remove CO2 from the atmosphere in three environmental control systems of the Shuttle program, and the investigation of the performance dependent parameters for the CO2 reaction with LiOH is reported. Emphasis is placed on LiOH quality acceptance criteria and on identifiying the relationships between the reaction rate and the following independent parameters: temperature, CO2 partial pressure (PP), H2O concentration in the solid, amount of remaining LiOH and the porosity of the LiOH pellets. Results showed that the reaction rate is proportional to the CO2 PP for PP at least as high as 40 mm Hg (5330 N/sq m). It is also noted that a significant difference in the reactivity of wet and dry LiOH was not detected.

Davis, S. H., Jr.↗

Use of pure nickel and LiOH for thermal energy storage

The solid to liquid phase transformation of LiOH has been proposed as an ideal candidate thermal energy storage media for a Rankine Cycle powered electrical generation unit envisioned in Space Station based solar dynamic systems. Due to the corrosive nature of molten hydroxides, long term containment of LiOH is of concern. Pure nickel is thought to be a suitably resistant material, and a program has been instituted to measure the effects of prolonged exposure of liquid and gaseous LiOH on the mechanical properties of pure nickel alloys. Results to date indicate that negligible weight and thickness changes occurred in Ni alloys exposed to LiOH for as long as 2500 hr at 775 K, and essentially no difference in 77-900 K tensile properties could be detected between LiOH exposed and vacuum annealed Ni specimens. Although there was little sign of outward damage, microstructural examination revealed that all hydroxide contaminated tensile test specimens had surface connected intergranular cracks along the gage lengths. Two other potential problems, which have strong implications with respect to a LiOH/Ni energy storage system, were also noted during the corrosion experiments. In particular stress corrosion cracking of weld joints in pressurized vessel and permeation of hydrogen through nickel were observed.

Whittenberger, J. D.↗

The properties of and analytical methods for detection of LiOH and Li2CO3

Lithium hydroxide (LiOH) is used as a CO2 absorbent in the Shuttle Extravehicular Mobility Unit (EMU) Portable Life Support System (PLSS). The first objective was to survey parameters that may be used to indicate conversion of LiOH to Li2CO3, and compile a list of all possible properties, including physical, chemical, structural, and electrical, that may serve to indicate the occurrence of reaction. These properties were compiled for the reactant (LiOH), the intermediate monohydrate compound (LiOH.H2O), and the final product (Li2CO3). The second objective was to survey measurement and analytical techniques which may be used in conjunction with each of the properties identified above, to determine the extent of conversion of LiOH to Li2CO3. Both real-time and post-run techniques were of interest. The techniques were also evaluated in terms of complexity, technology readiness, materials/equipment availability, and cost, where possible.

Selvaduray, Guna↗

Properties of pure nickel after long term exposures to LiOH and vacuum at 775 K

The solid to liquid phase transformation of LiOH at 744.3 K is considered to be an ideal candidate thermal energy storage (TES) mechanism for a Rankine heat engine based solar dynamic system operating at approximately 682 K. While pure nickel is thought to be a suitable containment material for LiOH, long term containment is of concern because molten hydroxides are usually corrosive. Two commercially pure nickel alloys, Ni-200 and Ni-201, were exposed to molten LiOH, its vapor, and vacuum at 775 K for periods ranging from 50 to 5000 h, and simple mechanical property measurements (77 to 900 K tensile and 750 K creep rupture) of exposed alloys were undertaken. The mechanical property test procedures are described and tabular lists of the test data are presented.

Whittenberger, J. D.↗

The dependence of the CO2 removal efficiency of LiOH on humidity and mesh size

The effect of humidity on the CO2 removal efficiency of small beds of anhydrous LiOH has been studied. Experimental data taken in this small bed system clearly show that there is an optimum humidity for beds loaded with LiOH from a single lot. The CO2 efficiency falls rapidly under dry conditions, but this behavior is approximately the same in all samples. The behavior of the bed under wet conditions is quite dependent on material size distribution. The presence of large particles in a sample can lead to rapid fall off in the CO2 efficiency as the humidity increases.

Davis, S. H.↗

On the dissociation energy of CaOH and LiOH

A technique for computing the dissociation energy of ionic diatomics is extended to the ionic triatomics LiOH and CaOH. The calculated Do values (with the recommended experimental values in parentheses) are 4.72 plus or minus 0.06 eV (4.53 plus or minus 0.04) for LiOH and 4.13 plus or minus 0.07 (4.23 eV) for CaOH.

Bauschlicher, C. W., Jr.↗

A preliminary report on the effects of long-term exposure of LiOH on pure nickel

A 'bread pan' capsule has been designed which allows large numbers of tensile specimens to be simultaneously exposed to molten LiOH, its vapor, and vacuum. Capsules and specimens fabricated from the pure nickel alloy Ni-200 were annealed for 401 hours and 2500 hours at 775 K. Examination of the exposed materials revealed that little outward damage in terms of visible attack, weight change, or loss of room temperature tensile properties occurred. In particular, the mechanical behavior of hydroxide-contaminated alloy was essentially identical to that receiving a simple thermal exposure in vacuum. Examination of the microstructures revealed that LiOH did produce some nonuniform, shallow intergranular corrosion in NI-200; however, the extent of the damage was insufficient to produce weakening or embrittlement.

Whittenberger, J. D.↗

Apollo 13 LiOH canister breakthrough test

The Apollo 13 lithium hydroxide canister test was conducted to evaluate emergency measures designed to enable the Apollo 13 crew to use command module lithium hydroxide canisters in the lunar module. The test verified the effectiveness of the emergency system and established that the canisters in the command module would provide ample carbon dioxide removal for the return of the Apollo 13 crew. The time interval between canister changes on the flight was also determined in the test. This reduced power demand on the lunar module by eliminating the need for telemetry in determining canister replacement times. Details of the canister modifications were relayed to the flight crew and a replica of the test system was assembled in the flight vehicle. Graphs of the parameters which were measured during the simulation are presented.

Leblanc, J. C.↗

Orion Post Landing LiOH and Toxic Sensor Development

The Orion Crew Exploration Vehicle (CEV) lands in the water with most resources depleted. There is a need to provide CO2 control while the cabin remains sealed for two hours post landing and there is a need to verify the outside air is free of ammonia or propellants, which may be venting from the vehicle, prior to opening the cabin. Development of approaches to perform these tasks while minimizing weight, volume, and cost are being investigated. This paper will document the results of those investigations.

Lewis, John F.↗

Root Cause Assessment of Pressure Drop Rise of a Packed Bed of Lithium Hydroxide in the International Space Station Trace Contaminant Control System

The trace contaminant control system (TCCS) located in the International Space Station s (ISS) U.S. laboratory module employs physical adsorption, thermal catalytic oxidation, and chemical adsorption to remove trace chemical contamination produced by equipment offgassing and anthropogenic sources from the cabin atmosphere. The chemical adsorption stage, consisting of a packed bed of granular lithium hydroxide (LiOH), is located after the thermal catalytic oxidation stage and is designed to remove acid gas byproducts that may be formed in the upstream oxidation stage. While in service on board the ISS, the LiOH bed exhibited a change in flow resistance that leading to flow control difficulties in the TCCS. Post flight evaluation revealed LiOH granule size attrition among other changes. An experimental program was employed to investigate mechanisms hypothesized to contribute to the change in the packed bed s flow resistance. Background on the problem is summarized, including a discussion of likely mechanisms. The experimental program is described, results are presented, and implications for the future are discussed.

Aguilera, Tatiana↗

CO2 and humidity removal system for extended Shuttle missions - Equilibrium testing and performance analysis

In Shuttle orbiter cabins, lithium hydroxide (LiOH) canisters are currently planned to be used for CO2 adsorption and condensing heat exchangers for humidity control. In this paper a more effective CO2 and humidity removal method is proposed by replacing the LiOH component with HS-C adsorbent (a polyethylenimine coated acrylic ester), thus eliminating the low temperature constraints on the active thermal control system. Since the adsorption of CO2 and H2O are reversible, a double bed configuration operating cyclicly is planned to provide continuous atmospheric control. Apparatus and the experimental procedure to test the adsorption equilibrium are described and some of the indicative results, tabulated by computers, are presented with the help of exponential expressions and differential equations. By using a computer model of the Shuttle HS-C system, performance predictions are made.

Davis, S. H.↗

A regenerable CO2 and humidity control system for Shuttle

A regenerable CO2 and humidity control system is presently being developed for potential use on Shuttle as an alternate to the baseline Lithium Hydroxide (LiOH) system. The system utilizes a sorbent material (designated 'HS-C') to adsorb CO2 and water vapor from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum. Past development programs concentrated on material development and breadboard system fabrication and testing. The present program calls for the design of a flight prototype system capable of integration into the Shuttle vehicle and the development of major components. This paper will show that a regenerable system utilizing HS-C material trades even with the shuttle LiOH system for the baseline four-man, seven-day mission and offers increased savings up to 448 kg for a seven-man, 30-day mission.

Boehm, A. M.↗

Recycling Lithium Carbonate/Lithium Hydroxide Waste

Hazardous waste disposal problem eliminated by regeneration. Li2CO3/ LiOH recycling process relies on low solubility of alkali carbonates in corresponding hydroxides. Li2CO3 precipitate calcined to LI2O, then rehydrated LiOH. Regeneration eliminates need to dispose caustic waste and uses less energy than simple calcination of entire waste mass.

Flowers, J.↗

Development of Pressure Swing Adsorption Technology for Spacesuit Carbon Dioxide and Humidity Removal

Metabolically produced carbon dioxide (CO2) removal in spacesuit applications has traditionally been accomplished utilizing non-regenerative Lithium Hydroxide (LiOH) canisters. In recent years, regenerative Metal Oxide (MetOx) has been developed to replace the Extravehicular Mobility Unity (EMU) LiOH canister for extravehicular activity (EVA) missions in micro-gravity, however, MetOx may carry a significant weight burden for potential use in future Lunar or planetary EVA exploration missions. Additionally, both of these methods of CO2 removal have a finite capacity sized for the particular mission profile. Metabolically produced water vapor removal in spacesuits has historically been accomplished by a condensing heat exchanger within the ventilation process loop of the suit life support system. Advancements in solid amine technology employed in a pressure swing adsorption system have led to the possibility of combining both the CO2 and humidity control requirements into a single, lightweight device. Because the pressure swing adsorption system is regenerated to space vacuum or by an inert purge stream, the duration of an EVA mission may be extended significantly over currently employed technologies, while markedly reducing the overall subsystem weight compared to the combined weight of the condensing heat exchanger and current regenerative CO2 removal technology. This paper will provide and overview of ongoing development efforts evaluating the subsystem size required to manage anticipated metabolic CO2 and water vapor generation rates in a spacesuit environment.

Papale, William↗

Launch-Off-Need Shuttle Hubble Rescue Mission: Medical Issues

The Space Shuttle Hubble repair mission (STS-125) is unique in that a rescue mission (STS-400) has to be ready to launch before STS-125 life support runs out should the vehicle become stranded. The shuttle uses electrical power derived from fuel cells that use cryogenic oxygen and hydrogen (CRYO) to run all subsystems including the Environmental Control System. If the STS-125 crew cannot return to Earth due to failure of a critical subsystem, they must power down all nonessential systems and wait to be rescued by STS-400. This power down will cause the cabin temperature to be 60 F or less and freeze the rest of the vehicle, preventing it from attempting a reentry. After an emergency has been declared, STS-125 must wait at least 7 days to power down since that is the earliest that STS-400 can be launched. Problem The delayed power down of STS-125 causes CYRO to be consumed at high rates and limits the survival time after STS-400 launches to 10 days or less. CRYO will run out sooner every day that the STS-400 launch is delayed (weather at launch, technical issues etc.). To preserve CRYO and lithium hydroxide (LiOH - carbon dioxide removal) the crew will perform no exercise to reduce their metabolic rates, yet each deconditioned STS-125 crewmember must perform an EVA to rescue himself. The cabin may be cold for 10 days, which may cause shivering, increasing the metabolic rate of the STS-125 crew. Solution To preserve LiOH, the STS-125 manifest includes nutrition bars with low carbohydrate content to maintain crew respiratory quotient (RQ) below 0.85 as opposed to the usual shuttle galley food which is rich in carbohydrates and keeps the RQ at approximately 0.95. To keep the crew more comfortable in the cold vehicle warm clothing also has been included. However, with no exercise and limited diet, the deconditioned STS-125 crew returning on STS-400 may not be able to egress the vehicle autonomously requiring a supplemented crash-and-rescue capability.

Hamilton, Douglas↗

Carbon Dioxide Removal Troubleshooting aboard the International Space Station (ISS) during Space Shuttle (STS) Docked Operations

The International Space Station (ISS) represents a largely closed-system habitable volume which requires active control of atmospheric constituents, including removal of exhaled Carbon Dioxide (CO2). The ISS provides a unique opportunity to observe system requirements for (CO2) removal. CO2 removal is managed by the Carbon Dioxide Removal Assembly (CDRA) aboard the US segment of ISS and by Lithium Hydroxide (LiOH) aboard the Space Shuttle (STS). While the ISS and STS are docked, various methods are used to balance the CO2 levels between the two vehicles, including mechanical air handling and management of general crew locations. Over the course of ISS operation, several unexpected anomalies have occurred which have required troubleshooting, including possible compromised performance of the CDRA and LiOH systems, and possible imbalance in CO2 levels between the ISS and STS while docked. This paper will cover efforts to troubleshoot the CO2 removal systems aboard the ISS and docked STS.

Matty, Christopher M.↗

Crew Health and Performance Improvements with Reduced Carbon Dioxide Levels and the Resource Impact to Accomplish Those Reductions

Carbon dioxide (CO2) removal is one of the primary functions of the International Space Station (ISS) atmosphere revitalization systems. Primary CO2 removal is via the ISS s two Carbon Dioxide Removal Assemblies (CDRAs) and the Russian carbon dioxide removal assembly (Vozdukh); both of these systems are regenerable, meaning that their CO2 removal capacity theoretically remains constant as long as the system is operating. Contingency CO2 removal capability is provided by lithium hydroxide (LiOH) canisters, which are consumable, meaning that their CO2 removal capability disappears once the resource is used. With the advent of 6 crew ISS operations, experience showing that CDRA failures are not uncommon, and anecdotal association of crew symptoms with CO2 values just above 4 mmHg, the question arises: How much lower do we keep CO2 levels to minimize the risk to crew health and performance, and what will the operational cost to the CDRAs be to do it? The primary crew health concerns center on the interaction of increased intracranial pressure from fluid shifts and the increased intracranial blood flow induced by CO2. Typical acute symptoms include headache, minor visual disturbances, and subtle behavioral changes. The historical database of CO2 exposures since the beginning of ISS operations has been compared to the incidence of crew symptoms reported in private medical conferences. We have used this database in an attempt to establish an association between the CO2 levels and the risk of crew symptoms. This comparison will answer the question of the level needed to protect the crew from acute effects. As for the second part of the question, operation of the ISS s regenerable CO2 removal capability reduces the limited life of constituent parts. It also consumes limited electrical power and thermal control resources. Operation of consumable CO2 removal capability (LiOH) uses finite consumable materials, which must be replenished in the long term. Therefore, increased CO2 removal means increased resource use, with increased logistical capability to maintain necessary resources on board ISS. We must strike a balance between sufficiently low CO2 levels to maintain crew health and CO2 levels which are operationally feasible for the ISS program

James, John T.↗