Cellulose hydrolysis in acidified LiBr molten salt hydrate (MSH) media
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
In this study, the isopiestic molalities for the systems LiBr–H 2 O, CaBr 2 –H 2 O and LiBr–CaBr 2 –H 2 O were measured at 373.15 K with the isopiestic method using the Oak Ridge National Laboratory (ORNL) high–temperature gravimetric isopiestic apparatus. The osmotic coefficients were determined based on the lithium chloride and sodium chloride reference standards. The vapor pressure diagrams and osmotic coefficient diagrams at different mole fraction for LiBr were plotted. The calculated vapor pressure with water activities agree well with the experimental data. On the basis of Pitzer original and its extended model, the Pitzer binary parameters β (0) , β (1) C (0) and C (1) for the systems LiBr–H 2 O and CaBr 2 –H 2 O and mixing parameters of θ Li,Ca and ψ Li,Ca,Br were fitted with the measured osmotic coefficients. The calculated osmotic coefficients for systems LiBr–H 2 O and CaBr 2 –H 2 O agree well with the experimental data. The agreement between the calculated water activities and experimental results for the ternary system indicates that the parameters obtained in this work are reliable for water activity calculation. Finally, the thermodynamic data obtained in this study are essential for development of universal thermodynamic models for brine systems containing lithium bromide and calcium bromide.
An experimental study on absorption characteristics of water vapor into a thin lithium bromide (LiBr) solution flow is presented. The LiBr solution flow is constrained between a superhydrophobic vapor permeable wall and a solid surface that removes the heat of absorption. As opposed to conventional falling film absorbers, in this configuration, the solution film thickness and velocity can be controlled independently to enhance the absorption rate. The effects of water vapor pressure, cooling surface temperature, solution film thickness, and solution flow velocity on the absorption rate are studied. An absorption rate of approximately 0.006 kg/m(2) s was measured at a LiBr solution channel thickness and flow velocity of 100 mu m and 5 mm/s, respectively. The absorption rate increased linearly with the water vapor driving potential at the test conditions of this study. It was demonstrated that decreasing the solution film thickness and increasing the solution velocity enhance the absorption rate. The high absorption rate and the inherently compact form of the proposed,absorber facilitate development of compact small-scale waste heat or solar-thermal driven cooling systems. Published by Elsevier Ltd.
Improved methods for achieving the selective extraction of lithium salts from lithium sources, including rocky ores, salt-lake brines, and end-of-life lithium-ion batteries, could help address projected increases in the demand for lithium. Here, we report an ion pair receptor (2) capable of extracting LiCl and LiBr into an organic receiving phase both from the solid state and from aqueous solutions. Ion pair receptor 2 consists of a calix[4]pyrrole framework, which acts as an anion binding site, linked to a phenanthroline cation binding motif via ether linkages. Receptor 2 binds MgBr 2 and CaCl 2 with high selectivity over the corresponding lithium salts in a nonpolar aprotic solvent. The preference for Mg 2+ and Ca 2+ salts is reversed in polar protic media, allowing receptor 2 to complex LiCl and LiBr with high selectivity and affinity in organic media containing methanol or water. The effectiveness of receptor 2 as an extractant for LiCl and LiBr under liquid–liquid extraction (LLE) conditions was found to be enhanced by the presence of other potentially competitive salts in the aqueous source phase.
Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity
Thermodynamic models are essential to facilitate the advancement of process design, optimization, and operation of electrolyte systems. In this work, a comprehensive thermodynamic framework based on the Electrolyte Nonrandom Two-Liquid model is developed to calculate phase equilibria behavior and salt solubility of aqueous LiCl, LiBr, LiI, and LiNO 3 solutions. The model describes the non-ideality of the electrolyte solutions by using two binary interaction parameters for each electrolyte-molecule pair in the system. Each binary interaction parameter is further expressed with up to three temperature coefficients which are regressed from experimental data. To take into account the hydration of lithium ion, two separate chemistries for the dissociation of lithium salts are investigated. In the first case, the lithium ion is considered as a bare ion, Li + , while in the second case hydration of the lithium ion from Li + to Li(H 2 O) + is considered. Here, the calculated thermodynamic properties compare adequately with the experimental data for both sets of chemistries for concentrations up to saturation and temperatures from 273.15 K up to 623.15 K. Moderate to significant improvements are observed with the incorporation of the hydration chemistry for aqueous LiCl, LiBr, and LiI solutions when compared to the non-hydrated lithium ion model results.
LiBr is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Li1+ is bonded to six equivalent Br1- atoms to form a mixture of corner and edge-sharing LiBr6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Li–Br bond lengths are 2.76 Å. Br1- is bonded to six equivalent Li1+ atoms to form a mixture of corner and edge-sharing BrLi6 octahedra. The corner-sharing octahedral tilt angles are 0°.
LiBr is Wurtzite structured and crystallizes in the hexagonal P6_3mc space group. The structure is three-dimensional. Li1+ is bonded to four equivalent Br1- atoms to form corner-sharing LiBr4 tetrahedra. All Li–Br bond lengths are 2.56 Å. Br1- is bonded to four equivalent Li1+ atoms to form corner-sharing BrLi4 tetrahedra.
A slow molecular diffusion rate often limits the desorption process of an absorbate molecule from a liquid absorbent. To enhance the desorption rate, the absorbent is often boiled to increase the liquid vapor interfacial area. However, the growth of bubbles generated during the nucleate boiling process still remains mass-diffusion limited. Here, it is shown that a desorption rate higher than that of boiling can be achieved, if the vapor absorbent interface is continuously replenished with the absorbate-rich solution to limit the concentration boundary layer growth. The study is conducted in a LiBr-water-solution, in which the water molecules' diffusion rate is quite slow. The manipulation of the vapor solution interface concentration distribution is enabled by the mechanical confinement of the solution flow within microchannels, using a hydrophobic vapor-venting membrane and the implementation of microstructures on the flow channel's bottom wall. The microstructures stretch and fold the laminar streamlines within the solution film and produce vortices. The vortices continuously replace the concentrated solution at the vapor solution interface with the water-rich solution brought from the bottom and middle of the flow channel. The physics of the process is described using a combination of experimental and numerical studies. Published by Elsevier Ltd.
The physics of water desorption from a lithium bromide (LiBr) solution flow through an array of microchannels capped by a porous membrane is studied. The membrane allows the vapor to exit the flow and retains the liquid. Effects of different parameters such as wall temperature, solution and vapor pressures, and solution mass flux on the desorption rate were studied. Two different mechanisms of desorption are analyzed. These mechanisms consisted of: (1) direct diffusion of water molecules out of the solution and their subsequent flow through the membrane and (2) formation of water vapor bubbles within the solution and their venting through the membrane. Direct diffusion was the dominant desorption mode at low surface temperatures and its magnitude was directly related to the vapor pressure, the solution concentration, and the heated wall temperature. Desorption at the boiling regime was predominantly controlled by the solution flow pressure and mass flux. Microscale visualization studies suggested that at a critical mass flux, some bubbles are carried out of the desorber through the solution microchannels rather than being vented through the membrane. Overall, an order of magnitude higher desorption rate compare to a previous study on a membrane-based desorber was achieved. Published by Elsevier Ltd.
Correction for ‘Ion pair extractant selective for LiCl and LiBr’ by Nam Jung Heo et al. , Chem. Sci. , 2024, 15 , 13958–13965, https://doi.org/10.1039/D4SC03760J.
Thermodynamics of LiBr in anhydrous dimethyl sulfoxide determined at several temperatures using EMF method
Not Available
Nature of free radicals in Bokkeveld meteorite from paramagnetic resonance signals
Electron spin resonance of carbonaceous meteorites
Electronic paramagnetic resonance of free organic radicals in meteorites
A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.