Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lasers, Optics and optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser probe for measuring 2-D wave slope spectra of ocean capillary waves

A laser-optical instrument for use in determining the two-dimensional wave-slope spectrum of ocean capillary waves is described. The instrument measures up to a 35-deg tip angle of the surface normal by measuring the position of a refracted laser beam directed vertically upward through a water surface. A telescope, a continuous two-dimensional Schottky barrier photodiode, and a pair of analog dividers render the signals independent of water height and insensitive to laser-beam intensity fluctuations. Calibration is performed entirely in the laboratory before field use. Sample records and wave-slope spectra are shown for one-dimensional wave-tank tests and for two-dimensional ocean tests. These are presented along with comparison spectra for calm and choppy water conditions. A mechanical wave follower was used to adjust the instrument position in the presence of large ocean swell and tides.

Palm, C. S.↗

SoW for KDP Precision Cleaning System Control Sys Refurbishment

The KDP Optic Precision Cleaning System (PCS) is used is a standalone batch-process system used to clean Potassium di-Hydrogen Phosphate (KDP) optics required for the National Ignition Facility (NIF). There are two nearly identical machines owned by the US government, as provided by Lawrence Livermore National Security (LLNS). One machine is located at Lawrence Livermore National Laboratory in Livermore, CA in a Class 100 cleanroom and the other is located at the Gooch & Housego (G&H) facility in Highland Heights, OH in a Class 1,000 cleanroom.

42 ENGINEERING↗

Moore Machine Motion Controls Refurbishment Statement of Work and Specification

Diamond Turning Machines known as “Moore” machines are used in the production of Potassium diHydrogen Phosphate (KDP) optics required for the National Ignition Facility (NIF). These machines are owned by the Department of Energy, as provided by Lawrence Livermore National Security LLC (LLNS). Moore Machines 1 and 2 are located at the Gooch & Housego (G&H) facility in Highland Heights, OH. The existing Aerotech motion controllers, motor drivers/amplifiers, input/output (I/O) hardware, control computer, software user interface, human machine interface (HMI), cabling, and encoders are beyond service life and require replacement. This Statement of Work (SoW) defines the motion control system refurbishment requirements for the Moore diamond turning machines designated Moore 1 and Moore 2. The motion controls system design shall include a motion control computer, control software, motor drive amplifiers and controllers, linear scale encoders, rotary encoders, HMI, power distribution, emergency stop (E-Stop) and interlocks, cabling, switches, solenoids, transducers, sensors, actuators, ancillary system interfaces, and related components necessary for a complete machine tool control system. The Subcontractor shall include effort to standardize systems between the two machines if reasonably possible.

42 ENGINEERING↗

Using NASA's Molecular Adsorber Coating Technology During Thermal Vacuum Testing to Protect Critical Laser Flight Optics on the ATLAS Instrument

The Molecular Adsorber Coating (MAC) is a sprayable coatings technology that was developed at NASA Goddard Space Flight Center (GSFC). The coating was designed to address molecular contamination concerns on or near sensitive surfaces and instruments within the spacecraft for flight or ground-based applications in vacuum conditions. This paper will discuss the use of NASA's MAC technology to isolate and protect the critical laser flight optics of the Advanced Topographic Laser Altimeter System (ATLAS) instrument on the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). MAC was strategically used during thermal vacuum (TVAC) testing efforts to reduce the risk of contaminating the laser optical components from non-baked items and other unknown outgassing sources from the chamber environment. This paper summarizes the design and implementation efforts, and the chemical analysis of the MAC samples that were used during two recent TVAC tests for the ICESat-2/ATLAS mission.

thermal vacuum↗

Using NASA's Molecular Adsorber Coating Technology During Thermal Vacuum Testing to Protect Critical Laser Flight Optics on the ATLAS Instrument

The Molecular Adsorber Coating (MAC) is a sprayable coatings technology that was developed at NASA Goddard Space Flight Center (GSFC). The coating was designed to address molecular contamination concerns on or near sensitive surfaces and instruments within the spacecraft for flight or ground-based applications in vacuum conditions. This paper will discuss the use of NASA's MAC technology to isolate and protect the critical laser flight optics of the Advanced Topographic Laser Altimeter System (ATLAS) instrument on the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). MAC was strategically used during thermal vacuum (TVAC) testing efforts to reduce the risk of contaminating the laser optical components from non-baked items and other unknown outgassing sources from the chamber environment. This paper summarizes the design and implementation efforts, and the chemical analysis of the MAC samples that were used during two recent TVAC tests for the ICESat-2/ATLAS mission.

molecular adsorber coating↗

Two-laser optical distance-measuring instrument that corrects for the atmospheric index of refraction.

The Wave Propagation Laboratory of the Environmental Research Laboratories of the National Oceanic and Atmospheric Administration has been engaged in the development of dual-wavelength, optical distance-measuring instruments. Recently a new generation of this type of high-accuracy instrument has been completed. Preliminary testing of the new instrument indicates that the original goal of the project, accuracy of better than one part in a million over distances of 5-10 km using averaging times of less than 1 min, is being met. This paper describes the instrument and preliminary test results.

Earnshaw, K. B.↗

Lasers '92; Proceedings of the International Conference on Lasers and Applications, 15th, Houston, TX, Dec. 7-10, 1992

Papers from the conference are presented, and the topics covered include the following: x-ray lasers, excimer lasers, chemical lasers, high power lasers, blue-green lasers, dye lasers, solid state lasers, semiconductor lasers, gas and discharge lasers, carbon dioxide lasers, ultrafast phenomena, nonlinear optics, quantum optics, dynamic gratings and wave mixing, laser radar, lasers in medicine, optical filters and laser communication, optical techniques and instruments, laser material interaction, and industrial and manufacturing applications.

Wang, Charles P.↗

Dynamic wavelength control of laser pulse profiles at picosecond to nanosecond timescales

We report on a novel combined laser pulse shaping and dynamic wavelength encoding capability based on a simple architecture implementing direct space to time mapping. There are several potential applications that can be enabled by the ability to control the instantaneous intensity or wavelength of an optical waveform on a picosecond-to-nanosecond timescale. To our knowledge, no known methods can access this temporal regime with a practical architecture. Here, we demonstrate an extension of the Space–Time Induced Linearly Encoded Transcription for Temporal Optimization (STILETTO) technique that can generate optical waveforms with a programmable instantaneous wavelength vs. time. We experimentally demonstrate the technique by generating self-gated spectrograms and show that it can encode dynamic wavelength vs time profiles at timescales not achievable by any other known method.

47 OTHER INSTRUMENTATION↗

Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument

We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.

Krainak, Michael A.↗

Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument

We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.

Krainak, Michael A.↗

Raman Spectroscopy to Detect and Measure NOW Pheromones. Annual Report [2021]

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural pheromones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes and how those evolve from emission points, especially across large blocks and at plot borders. We proposed to evaluate the use of enhanced Raman spectroscopy for the detection of synthetic and natural NOW pheromones and, were that to be successful, use it in subsequent years to measure pheromone diffusion in orchards.

47 OTHER INSTRUMENTATION↗

Raman Spectroscopy to Detect and Measure NOW Pheromones. Annual Report [Dec 2021]

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural pheromones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes and how those evolve from emission points, especially across large blocks and at plot borders. We proposed to evaluate the use of enhanced Raman spectroscopy for the detection of synthetic and natural NOW pheromones and, were that to be successful, use it in subsequent years to measure pheromone diffusion in orchards.

47 OTHER INSTRUMENTATION↗

Raman Spectroscopy to Detect and Measure NOW Pheromones

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can effectively help reducing crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural ones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes and how those evolve from emission points, especially across large blocks and at plot borders.

47 OTHER INSTRUMENTATION↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, M.↗