Techniques for the reduction of cyclic errors in laser metrology gauges for the space interferometry mission
This paper discusses the techniques for the reduction of cyclic errors in laser metrology gauges for the space interferometry mission.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This paper discusses the techniques for the reduction of cyclic errors in laser metrology gauges for the space interferometry mission.
The Space Interferometry Mission, scheduled for launch in 2008, is an optical stellar interferometer with a 10 meter baseline capable of micro-arcsecond accuracy astrometry.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
For precision displacement measurements, laser metrology is currently one of the most accurate measurements. Often, the measurement is located some distance away from the laser source, and as a result, stringent requirements are placed on the laser delivery system with respect to the state of polarization. Such is the case with the fiber distribution assembly (FDA) that is slated to fly aboard the Space Interferometry Mission (SIM) next decade. This system utilizes a concatenated array of couplers, polarizers and lengthy runs of polarization-maintaining (PM) fiber to distribute linearly-polarized light from a single laser to fourteen different optical metrology measurement points throughout the spacecraft. Optical power fluctuations at the point of measurement can be traced back to the polarization extinction ration (PER) of the concatenated components, in conjunction with the rate of change in phase difference of the light along the slow and fast axes of the PM fiber.
The Terrestrial Planet Finder (TPF) employs an aggressive coronagraph designed to obtain better than 1e-10 contrast inside the third Airy ring. Minute changes in low-order aberration content scatter significant light at this position. One implication is the requirement to control low-order aberrations induced by motion of the secondary mirror relative to the primary mirror; sub-nanometer relative positional stability is required. We propose a 6-beam laser truss to monitor the relative positions of the two mirrors. The truss is based on laser metrology developed for the Space Interferometry Mission.
A common-path laser heterodyne interferometer capable of measuring the internal optical path difference (OPD) with accuracy of the order of 10 pm was demonstrated at JPL. To achieve this accuracy, the relative power received by the detector that is contributed by the scattering of light at the optical surfaces should be less than -97 dB. A method has been developed to estimate the cyclic error caused by the scattering of the optical surfaces. The result of the analysis is presented.
Explore the source record for details and available documents.
A common-path laser heterodyne interferometer capable of measuring the internal OPD with accuracy of the order of 10 picometers was demonstrated at JPL. To achieve this accuracy, the relative power received by the detector that is contributed by the scattering of light at the optical surfaces should be less than -97 dB. A method has been developed to estimate the cyclic error caused by the scattering of the optical surfaces. The result of the analysis is presented.
Explore the source record for details and available documents.
The current design of the Space Interferometry Mission (SIM) employs a 19 laser-metrology-beam system (also called L19 external metrology truss) to monitor changes of distances between the fiducials of the flight system's multiple baselines. The function of the external metrology truss is to aid in the determination of the time-variations of the interferometer baseline. The largest contributor to truss error occurs in SIM wide-angle observations when the articulation of the siderostat mirrors (in order to gather starlight from different sky coordinates) brings to light systematic errors due to offsets at levels of instrument components (which include comer cube retro-reflectors, etc.). This error is labeled external metrology wide-angle field-dependent error. Physics-based model of field-dependent error at single metrology gauge level is developed and linearly propagated to errors in interferometer delay. In this manner delay error sensitivity to various error parameters or their combination can be studied using eigenvalue/eigenvector analysis. Also validation of physics-based field-dependent model on SIM testbed lends support to the present approach. As a first example, dihedral error model is developed for the comer cubes (CC) attached to the siderostat mirrors. Then the delay errors due to this effect can be characterized using the eigenvectors of composite CC dihedral error. The essence of the linear error model is contained in an error-mapping matrix. A corresponding Zernike component matrix approach is developed in parallel, first for convenience of describing the RMS of errors across the field-of-regard (FOR), and second for convenience of combining with additional models. Average and worst case residual errors are computed when various orders of field-dependent terms are removed from the delay error. Results of the residual errors are important in arriving at external metrology system component requirements. Double CCs with ideally co-incident vertices reside with the siderostat. The non-common vertex error (NCVE) is treated as a second example. Finally combination of models, and various other errors are discussed.
Optical and infrared interferometry will open new vistas for astronomy over the next decade. Space based interferometers, operating unfettered by the Earth's atmosphere, will offer the greatest scientific payoff. They also present the greatest technological challenge: laser metrology systems must perform with sub-nanometer precision; mechanical vibrations must be controlled to nanometers requiring orders of magnitude disturbance rejection; a multitude of actuators and sensors must operate flawlessly and in concert. The Jet Propulsion Laboratory along with its industry partners are addressing these challenges with a development program that plans to establish technology readiness for the Space Interferometry Mission by end of 2004.
The Micro-Arcsecond Metrology (MAM) team at the Jet Propulsion Laboratory has developed a precision phasemeter for the Space Interferometry Mission (SIM). The current version of the phasemeter is well-suited for picometer accuracy distance measurements and tracks at speeds up to 50 cm/sec, when coupled to SIM's 1.3 micron wavelength heterodyne laser metrology gauges. Since the phasemeter is implemented with industry standard FPGA chips, other accuracy/speed trade-off points can be programmed for applications such as metrology for earth-based long-baseline astronomical interferometry (planet finding), and industrial applications such as translation stage and machine tool positioning. The phasemeter is a standard VME module, supports 6 metrology gauges, a 128 MHz clock, has programmable hardware averaging, and a maximum range of 232 cycles (2000 meters at 1.3 microns).
We report on the development, functional performance and space-qualification status of a laser stabilization system supporting a space-based metrology source used to measure changes in optical path lengths in space-based stellar interferometers. The Space Interferometry Mission (SIM) and Deep Space 3 (DS-3) are two missions currently funded by the National Aeronautics and Space Administration (NASA) that are space-based optical interferometers. In order to properly recombine the starlight received at each telescope of the interferometer it is necessary to perform high resolution laser metrology to stabilize the interferometer. A potentially significant error source in performing high resolution metrology length measurements is the potential for fluctuations in the laser gauge itself. If the laser frequency or wavelength is changing over time it will be misinterpreted as a length change in one of the legs of the interferometer. An analysis of the frequency stability requirement for SIM resulted in a fractional frequency stability requirement of square root (S(sub y)(f)) = <2 x 10(exp -12)/square root(Hz) at Fourier frequencies between 10 Hz and 1000 Hz. The DS-3 mission stability requirement is further increased to square root (S(sub y)(f)) = <5 x 10(exp -14)/Square root(Hz) at Fourier frequencies between 0.2 Hz and 10 kHz with a goal of extending the low frequency range to 0.05 Hz. The free running performance of the Lightwave Electronics NPRO lasers, which are the baseline laser for both SIM and DS-3 vary in stability and we have measured them to perform as follows (9 x l0(exp -11)/ f(Hz))(Hz)/square root(Hz)) = <( square root (S(sub y)(f)) = <(1.3 x l0(exp -8)/ f(Hz))/Square root(Hz). In order to improve the frequency stability of the laser we stabilize the laser to a high finesse optical cavity by locking the optical frequency of the laser to one of the transmission modes of the cavity. At JPL we have built a prototype space-qualifiable system meeting the stability requirements of SIM, which has been delivered to one of the SIM testbeds. We have also started on the development of a system to meet the stability needs of DS-3.
The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.