Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laboratory procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determination of Biogenic Content by 14 C in fuels using Liquid Scintillation Analysis Laboratory Analytical Procedure (Laboratory Analytical Procedure)

This procedure covers the determination of the percent 14 C in biogenic gasoline, jet fuel, and diesel range hydrocarbons prepared from distillation of hydrotreated pyrolysis oils and blended with fossil derived hydrocarbons (e.g. fossil diesel, gasoline, jet, or toluene). Either an internal 14C standard or a color quench curve is used to correct for potential signal quenching effects. Recent publications provide some background of direct LSC methods used for determination of biogenic fuel content.

02 PETROLEUM↗

Determination of Total, Organic, and Inorganic Carbon and Total Nitrogen in Biological Cultures and Liquid Fraction Process Samples: Laboratory Analytical Procedure (LAP)

This Laboratory Analytical Procedure (LAP) describes the quantitative determination of total organic carbon, inorganic carbon in whole suspended biological samples and in the cell-free supernatant, by combustion and CO 2 detection with a non-dispersive infrared (NDIR) detector. This allows for distinct reporting of soluble and insoluble organic and inorganic carbon. In addition, this procedure covers the quantitative determination of soluble nitrogen in the cell-free supernatant.

09 BIOMASS FUELS↗

Accelerated Aging of Fast Pyrolysis Bio-Oil Using Carbonyl Titration: Laboratory Analytical Procedure (LAP)

This laboratory analytical procedure covers the accelerated aging of fast pyrolysis bio-oils. Bio-oils undergo reactions that result in physical and chemical changes over time. These changes typically result in an increase in molecular weight, decrease in some functional groups such as carbonyls, and an increase in viscosity; additionally, the aging process often leads to phase separation. Studies have shown that accelerated aging of bio-oils using this method closely mimics room temperature aging for long periods of time (over 3 years). This procedure has been developed for the accelerated aging of fast pyrolysis bio-oils only. Fast pyrolysis bio-oils are more reactive than other bio-oils (e.g., catalytic fast pyrolysis) and undergo aging much more rapidly. Therefore, this procedure should only be used for fast pyrolysis bio-oil samples.

09 BIOMASS FUELS↗

Identification and Quantification of Photosynthetic Pigments in Algae (Laboratory Analytical Procedure (LAP))

The Laboratory Analytical Procedure (LAP) outlined here describes a method to quantitatively extract phytopigments from microalgae biomass, as well as to identify and quantify individual pigments based on separation and detection with a High-Performance Liquid Chromatography (HPLC) system coupled to a Diode Array Detector (DAD). Pigments were extracted with greater than 95 % extraction efficiency. Chromatographic conditions allowed for isomeric resolution between pigments and identification based on UV/Vis spectra and comparison to analytical standards.

09 BIOMASS FUELS↗

Determination of Phenolic Groups in Bio-Oils Using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Phenol components are ubiquitous in wood-derived bio-oils and biocrudes. Their reaction with other functional groups (e.g., aldehydes) may contribute to the formation of carbonaceous species and the expected thermal instability of pyrolysis oils. During hydrotreating, phenols can be recalcitrant species, requiring higher reaction temperatures than other oxygen-containing functional groups. Phenols are also present in upgraded products and have been shown to lead to catalyst deactivation during hydrotreating. They also are the first oxygenated functional group to re-appear in the upgraded product, signaling catalyst deactivation. This procedure covers the determination of phenolic compounds in fast pyrolysis oils. This Laboratory Analytical Procedure (LAP) includes two methods, the first allowing for shorter analysis time at increased reaction temperature, while the second employs a longer analysis time but at room temperature. Additionally, the use of both a single cuvette and of a plate reader are also presented.

09 BIOMASS FUELS↗

Corrosivity Screening of Pyrolysis Bio-Oils by Short-Term Alloy Exposures. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Bio-oils contain organic acids and oxygenated compounds that can lead to corrosion issues during bio-oil processing and storage. This Laboratory Analytical Procedure (LAP) allows for rapid screening of a bio-oil's corrosivity without the need for complex equipment and long-term exposures. A robust and repeatable method for assessing the corrosivity of bio-oils is necessary in order to remove materials degradation as an obstacle to research, upgrading, use and storage of bio-oils. This LAP involves the incubation of a representative alloy, 410 stainless steel (410 SS), specimen in bio-oil over a period of 48 hours at 50 degrees C in a sealed container. The corrosive species in the bio-oil react with and deplete alloy elements such as iron (Fe) and/or chromium (Cr) from the specimen into the bio-oil solution. The depletion of Fe and Cr from the specimen results in a significant mass loss that can be recorded. The mass loss is directly correlated to the corrosivity of a bio-oil. Examples of bio-oils in scope include the ones produced by fast pyrolysis and catalytic fast pyrolysis, as well as liquids produced from hydrothermal liquefaction.

09 BIOMASS FUELS↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

Determination of Carbon Functional Groups in Pyrolysis Bio-Oils using 13 C NMR: Laboratory Analytical Procedure (LAP)

Pyrolysis is a process that can be used to convert biomass to solid, liquid and gaseous products for use as renewable chemicals and fuels. The liquid fraction, known as “bio-oil” is complex and challenging to characterize, particularly by means of GC/MS, GPC, LC and FT-IR. NMR is capable of analyzing whole bio-oil samples and can provide quantitative results to characterize different functional groups or types of carbon present in bio-oil. This Laboratory Analytical Procedure (LAP) quantifies different carbon functional groups in whole bio-oil samples. This information can be used for comparisons between different pyrolysis experimental conditions or different upgrading processes and catalysts, and also allow for comparisons between bio-oils produced at different facilities.

09 BIOMASS FUELS↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗

A Corrected Score Function Framework for Modelling Circadian Gene Expression

Many biological processes display oscillatory behaviour based on an approximately 24 h internal timing system specific to each individual. One process of particular interest is gene expression, for which several circadian transcriptomic studies have identified associations between gene expression during a 24 h period and an individual's health. A challenge with analysing data from these studies is that each individual's internal timing system is offset relative to the 24 h day-night cycle, where day–night cycle time is recorded for each collected sample. Laboratory procedures can accurately determine each individual's offset and determine the internal time of sample collection. However, these laboratory procedures are labour-intensive and expensive. Here, in this paper, we propose a corrected score function framework to obtain a regression model of gene expression given internal time when the offset of each individual is too burdensome to determine. A feature of this framework is that it does not require the probability distribution generating offsets to be symmetric with a mean of zero. Simulation studies validate the use of this corrected score function framework for cosinor regression, which is prevalent in circadian transcriptomic studies. Illustrations with data from three circadian transcriptomic studies further demonstrate that the proposed framework consistently mitigates bias relative to using a score function that does not account for this offset.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of Cellulosic Glucan Content in Starch Containing Feedstocks (Laboratory Analytical Procedure)

Carbohydrates make up a major portion of biomass samples. These carbohydrates are polysaccharides constructed primarily of glucose, xylose, arabinose, galactose, and mannose monomeric subunits. One such polysaccharide is starch, which is present in certain types of biomass. Starch will contribute to the overall glucose measurement when it breaks into the glucose subunit. Starch is often a more readily accessible source of glucose than structurally bound glucose polymers. Due to the different chemical nature of the glucan species, it is often advantageous to determine the amount of cellulosic glucose separately from the starch glucan.

09 BIOMASS FUELS↗

AGC 4 Graphite Specimen Postirradiation Characterization Plan

This characterization plan describes the thermal, physical, and mechanical measurement techniques that will be used to characterize graphite samples being tested in the fourth Advanced Graphite Creep experiment (AGC-4). Instruments, fixtures, and methods are currently in place for both pre and postirradiation material property measurements of bulk density, thermal diffusivity, coefficient of thermal expansion, elastic modulus, and electrical resistivity. Postirradiation testing procedures used to characterize the samples are described and discussed in the plan. Where they exist, American Society for Testing and Materials (ASTM) International testing standards will apply to the tests. Any departure from ASTM International testing standards or the approved laboratory procedures are documented within this characterization plan. Deviations that occur during testing will be documented in data reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low-cost production method for fluorescent particles for liquid flow velocimetry applications

Abstract In this Technical Note, we present a simple and low-cost production method for fluorescent particles perfectly suitable for velocimetry applications. We leverage the unique ability of Nile Red (NR) fluorophores to adsorb on the polymer surface and/or embed itself in between polymeric chains. The laboratory procedure to dye polyamide particles with NR and monetary advantages over commercially available fluorescent particles is outlined. Subsequently, the fluorescence behavior of the dyed particles is tested under a laser illumination source in polar and non-polar liquids. The distinct advantage of the emission spectrum of NR-dyed particles is demonstrated with sample test results.

42 ENGINEERING↗

Gaussian Process Modeling For Experimental Procedure Uncertainty

Many laboratory experiments generate data that are characterized by a form of uncertainty that differs from noise: experimental procedure uncertainty. The origin of this type of uncertainty is the difficulty in controlling a subset of experimental conditions in such a way that the experiment is perfectly reproducible within noise. In this report, we describe a Gaussian Process modeling-based method that accounts for experimental procedure uncertainty. The method accounts for variations in conditions from experiment to experiment that are independent between experiments, but correlated within each experiment, and incorporates the resulting uncertainty into predictions at future experimental settings. The method is discussed in the context of a specific chemistry application in which Raman scattering spectra are measured from three-component mixtures.

42 ENGINEERING↗

LLNL ES&H Analytical Services and Instrumentation Analytical Laboratory (ALAB) (CY2022 Management Review Report)

"An annual review shall be conducted of the analytical activities to ensure continuing suitability, adequacy, and effectiveness." (ALAB-01 Rev 6 ALQAP section 6.11.2) "The laboratory management shall review its management system at planned intervals, in order to ensure its continuing suitability, adequacy and effectiveness..."(ISO/IEC 17025:2017 Section 8.9.1) "In accordance with a predetermined schedule and procedure, the laboratory's top management shall periodically conduct a review of the laboratory's management system and testing and/or calibration activities to ensure their continuing suitability and effectiveness, and to introduce necessary changes or improvements. "(TNI Standard EL-V1M2-2016-Rev2.1:Quality Systems General Requirements)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical note: Optimizing the in situ cosmogenic 36 Cl extraction and measurement workflow for geologic applications

Abstract. In situ cosmogenic 36Cl analysis by accelerator mass spectrometry (AMS) is routinely employed to date Quaternary surfaces and assess rates of landscape evolution. However, standard laboratory preparation procedures for 36Cl dating require the addition of large amounts of isotopically enriched chlorine spike solution; these solutions are expensive and increasingly difficult to acquire from commercial sources. In addition, the typical workflow for 36Cl dating involves measuring both 35Cl/37Cl and 36Cl/Cl concurrently on the high-energy (post-accelerator) end of the AMS system, but 35Cl/37Cl determinations using this technique can be complicated by isotope fractionation and system memory during measurement. The traditional workflow also does not provide 36Cl extraction laboratories with the data needed to calculate native Cl concentrations in advance of 36Cl/Cl measurements. In light of these concerns, we present an improved workflow for extracting and measuring chlorine in geologic materials. Our initial step is to characterize 35Cl/37Cl on sample aliquots of up to ∼1 g prepared in Ag(Cl, Br) matrices, which greatly reduces the amount of isotopically enriched spike solution required to measure native Cl content in each sample. To avoid potential issues with isotope fractionation through the accelerator, 35Cl/37Cl is measured on the low-energy, pre-accelerator end of the AMS line. Then, for 36Cl/Cl measurements, we extract Cl as AgCl or Ag(Cl, Br) in analytical batches with a consistent total Cl load across all samples; this step is intended to minimize source memory effects during 36Cl/Cl measurements and allows the preparation of AMS standards that are customized to match known Cl contents in the samples. To assess the efficacy of this extraction and measurement workflow, we compare chlorine isotope ratio measurements on seven geologic samples prepared using standard procedures and the updated workflow. Measurements of 35Cl/37Cl and 36Cl/Cl are consistent between the two workflows, and 35Cl/37Cl values measured using our methods have considerably higher precision than those measured following standard protocols. The chemical preparation and measurement workflow presented here (1) reduces the amount of isotopically enriched chlorine spike used per rock sample by up to 95 %; (2) identifies rocks with high native Cl concentrations, which may be lower priority for 36Cl surface exposure dating, at an early stage of analysis; and (3) allows laboratory users to maintain control over the total chlorine content within and across analytical batches. These methods can be incorporated into existing laboratory and AMS protocols for 36Cl analyses and will increase the accessibility of 36Cl dating for geologic applications.

58 GEOSCIENCES↗

Scaling arguments for a plasma experiment relevant to an interplanetary coronal mass ejection

We present the design of a plasma experiment scaled to be relevant to an interplanetary coronal mass ejection (ICME) traveling from the Sun to the Earth. The experiment would launch a compact torus of plasma (the scaled analog of the coronal mass ejected by the Sun) into a magnetized background plasma (the scaled analog of the interplanetary medium, the diffuse magnetized plasma that fills the Solar System). We present the complete process of scaling the ICME system to a laboratory experiment: beginning with the ICME features that we aim to replicate with a laboratory experiment, explaining how these desired features are translated into specific design constraints, and presenting a set of experimental parameters that meet those constraints. We find that the experiment would be possible with plasma conditions typically achieved in large-scale facilities such as the Big Red Ball at the University of Wisconsin or the LArge Plasma Device at the University of California, Los Angeles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗