Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LPM effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The LPM effect in sequential bremsstrahlung: analytic results for sub-leading (single) logarithms

Consider the in-medium splitting g → gg of a very high-energy gluon traversing a QCD medium, accounting for the Landau-Pomeranchuk-Migdal (LPM) effect. It has been known for some time that soft radiative corrections to that splitting generate a double-log correction to the splitting rate, whose effects can be absorbed into running of the medium parameter $\hat{q}$ describing the rate of transverse momentum kicks to high-energy particles due to small-angle scattering from the medium. Less has been known about sub-leading, single logarithms in this context. In this paper, we find analytic formulas for those single logs (with various caveats and clarifications).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The LPM effect in sequential bremsstrahlung: incorporation of “instantaneous” interactions for QCD

The splitting processes of bremsstrahlung and pair production in a medium are coherent over large distances in the very high energy limit, which leads to a suppression known as the Landau-Pomeranchuk-Migdal (LPM) effect. We continue study of the case when the coherence lengths (formation lengths) of two consecutive splitting processes overlap, avoiding soft-emission approximations. Previous work made a “nearly-complete” calculation of the effect of overlapping formation times on gluonic splittings such as g → gg → ggg (with simplifying assumptions such as an infinite QCD medium and the large-N c limit). In this paper, we extend those previous rate calculations from nearly-complete to complete by including processes involving the exchange of longitudinally-polarized gluons. In the context of Lightcone Pertubation Theory, used earlier for the “nearly-complete” calculation, such exchanges are instantaneous in lightcone time and have their own diagrammatic representation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The LPM effect in sequential bremsstrahlung: 1/$ {\mathrm{N}}_{\mathrm{c}}^2 $ corrections

An important question concerning in-medium high-energy parton showers in a quark-gluon plasma or other QCD medium is whether consecutive splittings of the partons in a given shower can be treated as quantum mechanically independent, or whether the formation times for two consecutive splittings instead have significant overlap. Various previous calculations of the effect of overlapping formation times have either (i) restricted attention to a soft bremsstrahlung limit, or else (ii) used the large-N c limit (where N c = 3 is the number of quark colors). In this paper, we make a first study of the accuracy of the large-N c limit used by those calculations of overlap effects that avoid a soft bremsstrahlung approximation. Specifically, we calculate the 1/$ {\mathrm{N}}_{\mathrm{c}}^2 $ correction to previous N c = ∞ results for overlap g → gg → ggg of two consecutive gluon splittings g → gg. At order 1/$ {\mathrm{N}}_{\mathrm{c}}^2 $ , there is interesting and non-trivial color dynamics that must be accounted for during the overlap of the formation times.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Problem of overlapping formation times: In-medium virtual corrections for QCD

High energy particles traversing through medium primarily lose energy by showering through hard bremsstrahlung and pair production. These splitting processes are coherent over large distances in the very high energy limit, leading to suppression from the Landau-Pomeranchuk-Migdal (LPM) effect. Avoiding soft-emission approximations, we study the cases where the coherence lengths of two consecutive splittings overlap (which is important for calculating corrections to LPM effect in QCD). Here, we will show how to compute in-medium virtual corrections to the leading order LPM emission rates for QCD. These loop corrections will be necessary for calculating properties of in-medium high energy parton showers. To simplify the calculations, we will focus on the all-gluon case and work in the large-Nc limit of QCD, where Nc is the number of colors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Medium-induced radiative kernel with the Improved Opacity Expansion

We calculate the fully differential medium-induced radiative spectrum at next-to-leading order (NLO) accuracy within the Improved Opacity Expansion (IOE) framework. This scheme allows us to gain analytical control of the radiative spectrum at low and high gluon frequencies simultaneously. The high frequency regime can be obtained in the standard opacity expansion framework in which the resulting power series diverges at the characteristic frequency ω c ~ q^L 2 . In the IOE, all orders in opacity are resumed systematically below ωc yielding an asymptotic series controlled by logarithmically suppressed remainders down to the thermal scale T « ω c , while matching the opacity expansion at high frequency. Furthermore, we demonstrate that the IOE at NLO accuracy reproduces the characteristic Coulomb tail of the single hard scattering contribution as well as the Gaussian distribution resulting from multiple soft momentum exchanges. Finally, we compare our analytic scheme with a recent numerical solution, that includes a full resummation of multiple scatterings, for LHC-inspired medium parameters. Furthermore, we find a very good agreement both at low and high frequencies showcasing the performance of the IOE which provides for the first time accurate analytic formulas for radiative energy loss in the relevant perturbative kinematic regimes for dense media.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Lattice QCD estimates of thermal photon production from the QGP

Thermal photons produced in heavy-ion collision experiments are an important observable for understanding quark-gluon plasma (QGP). The thermal photon rate from the QGP at a given temperature can be calculated from the spectral function of the vector current correlator. Extraction of the spectral function from the lattice correlator is known to be an ill-conditioned problem, as there is no unique solution for a spectral function for a given lattice correlator with statistical errors. The vector current correlator, on the other hand, receives a large ultraviolet contribution from the vacuum, which makes the extraction of the thermal photon rate difficult from this channel. We therefore consider the difference between the transverse and longitudinal part of the spectral function, only capturing the thermal contribution to the current correlator, simplifying the reconstruction significantly. The lattice correlator is calculated for light quarks in quenched QCD at T = 470 MeV ( ∼ 1.5 T c ), as well as in 2 + 1 flavor QCD at T = 220 MeV ( ∼ 1.2 T p c ) with m π = 320 MeV . In order to quantify the nonperturbative effects, the lattice correlator is compared with the corresponding NLO + LPM LO estimate of correlator. The reconstruction of the spectral function is performed in several different frameworks, ranging from physics-informed models of the spectral function to more general models in the Backus-Gilbert method and Gaussian process regression. We find that the resulting photon rates agree within errors. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Flashback characterization of additively manufactured swirl-stabilized fuel injector with varying surface roughness

This work investigates the effects of as-built surface roughness on the flashback propensity in additively manufactured (AM) swirl-stabilized lean premixed (LPM) fuel injectors. Adoption of AM for rapid prototyping and fabrication of complex fuel-flexible injector designs requires investigating surface roughness effects on the flow and flame stability characteristics of the combustor. Wall roughness increases the near-wall shear, which could alter the boundary layer structure and change the propensity for flame flashback. Accounting for the realistic as-built surface roughness is crucial in carrying out computational modeling and experimental analysis to establish a feedback loop for the precision designing of fuel-flexible injectors. The presented numerical analysis of as-built AM injector is an essential consideration to optimize injector design for aerodynamics and additive manufacturability.

Mohanty, Pratikshya↗

The molten salt tritium transport experiment: A pumped fluoride salt loop for hydrogen isotope experimentation

Molten salt reactors (MSRs) and fusion reactors propose to use molten salts as coolants and breeder blanket materials, respectively. Tritium, however, poses safety concerns in both reactor types due to its ability to permeate through reactor materials and potential for environmental release. This manuscript addresses the tritium transport phenomena in molten salts and presents the design and analysis of the Molten Salt Tritium Transport Experiment (MSTTE). MSTTE is a forced-convection fluoride salt loop intended to measure hydrogen isotope permeation through structural materials in a flowing salt system. In the first phase, MSTTE will use FLiNaK salt and deuterium as surrogates for FLiBe and tritium, with future plans to utilize tritium and FLiBe. MSTTE couples a Copenhagen Atomics pumped salt loop with an external test section that introduces hydrogen isotopes into the loop and measures transport phenomena. The Hydrogen Injection System (HIS) controls hydrogen isotope introduction into the molten salt loop. Here, the permeation test section measures the permeation rate through stainless steel tubing in contact with flowing salt. Computational fluid dynamics (CFD) analysis ensures fully developed salt flow in the permeation test section. MSTTE is modeled with MELCOR-TMAP to predict the permeation rate as a function of experimental variables such as source term, salt flow rate, and salt temperature. Results indicate that the source term is the only parameter with a significant effect on the permeation rate. Pressure drop analysis suggests that the loop should operate below 200 LPM to maintain a pressure drop below 200 kPa. Additionally, finite-element analysis assesses thermal stress during loop operation to ensure the experiment's safe design. MSTTE will provide semi-integral data on tritium transport phenomena in molten salts and serve as a testbed for advancing molten salt technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EPCAPE-PT-LANL Measurements: Ground based counterflow virtual impactor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Ground based counter flow virtual impactor (Brechtel Inc) Data Notes: A factor of 6.7 needs to be applied to all cloud droplet residual concentration to correct the enhancement of the concentration because all the residual samples collected at 100 lpm were delivered into the 15 lpm of CVI sample flow. [https://amt.copernicus.org/articles/5/1259/2012/amt-5-1259-2012.html] Header: - Visibility[m]: The atmospheric visibility at the time of measurement, expressed in meters. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement passed quality control checks. - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage

54 ENVIRONMENTAL SCIENCES↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Coastal-Fog Microphysics Using In-Situ Observations and GOES-R Retrievals

Here, the objective of this work is to evaluate GOES-R based fog conditions occurred during the C-FOG (Toward Improving Coastal Fog Prediction) field campaign. C-FOG is designed to advance understanding of fog formation, development, and dissipation over coastal environments to improve its predictability. The project took place along coastlines and open water environments of Eastern Canada (Nova Scotia, NS and the Island of Newfoundland, NL) during August-October of 2018 where environmental conditions play an important role for late season’s fog formation. During the C-FOG field campaign, instruments were located at the Ferryland Supersite, NL, with 2 main sites, and five satellite sites, as well as on the Research Vessel (R/V) Hugh R. Sharp. Key measurement instruments included a Gondola carrying a CDP (cloud droplet probe) and a BCP (backscatter cloud probe) was used for measuring droplet spectra from 1-75 µm on the R/V. A LPM (laser precipitation monitor) with 100 µm-1 cm size range and an OPC (optical particle counter) with 0.3-17 µm at 16 spectral channels provided information for fog and drizzle discrimination. Remote sensing platforms (e.g. profiling microwave radiometer, PMWR), Ceilometer, Lidar), meteorological towers, tethered balloons, and GOES-R products (e.g. fog coverage and droplet size and liquid water path) were used to evaluate fog over horizontal and vertical dimensions. Results suggest that effective radius, phase, liquid water path, and liquid water content values obtained from GOES-R and PMWR were comparable to ground based in-situ observations. It is concluded that integration of observations and nowcasting products may help improve short term local fog predictions.

54 ENVIRONMENTAL SCIENCES↗

TAP Absorption Coefficients

The data set of aerosol light absorption coefficients were collected by two tricolor absorption photometers (TAP; Brechtel Model 2901) in July and August, 2022 during the TRACER field campaign at the AMF1 site in La Porte, Texas. One of the TAPs at the La Porte site was an RGB model measuring aerosol light absorption at 652, 528, 467 nm, and the other was an UV model measuring absorption at the same red and green wavelengths but at an additional UV wavelength at 365 nm. Since TAP is a filter-based optical instrument using 47-mm glass fiber filters, the output absorption coefficients are corrected for filter loading and scattering effects based on a correction scheme developed in "Comment on ‘Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols’" by John A. Ogren 2010. This uploaded dataset contains both the Ogren corrected absorption coefficients (column header with “ Ogren”) and the raw absorption coefficients without the correction scheme (column header with “_ Raw”). During the field campaign, the two TAPs operated side by side with a shared inlet at a flow rate of 2 lpm. In July, no inlet impactors/cyclones were installed; however, beginning in August, a PM2.5 cyclone inlet was installed.

54 ENVIRONMENTAL SCIENCES↗

Holographic measurement and bulk teleportation

Holography has taught us that spacetime is emergent and its properties depend on the entanglement structure of the dual theory. In this paper, we describe how changes in the entanglement due to a local projective measurement (LPM) on a subregion A of the boundary theory modify the bulk dual spacetime. We find that LPMs destroy portions of the bulk geometry, yielding post-measurement bulk spacetimes dual to the complementary unmeasured region A c that are cut off by end-of-the-world branes. Using a bulk calculation in AdS 3 and tensor network models of holography (in particular, the HaPPY code and random tensor networks), we show that the portions of the bulk geometry that are preserved after the measurement depend on the size of A and the state we project onto. The post-measurement bulk dual to A c includes regions that were originally part of the entanglement wedge of A prior to measurement. This suggests that LPMs performed on a boundary subregion A teleport part of the bulk information originally encoded in A into the complementary region A c . In semiclassical holography an arbitrary amount of bulk information can be teleported in this way, while in tensor network models the teleported information is upper-bounded by the amount of entanglement shared between A and A c due to finite-N effects. When A is the union of two disjoint subregions, the measurement triggers an entangled/disentangled phase transition between the remaining two unmeasured subregions, corresponding to a connected/disconnected phase transition in the bulk description. Our results shed new light on the effects of measurement on the entanglement structure of holographic theories and give insight on how bulk information can be manipulated from the boundary theory. They could also represent a first step towards a holographic description of measurement-induced phase transitions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗