Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIQUID SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Searching for dark matter annihilation to monoenergetic neutrinos with liquid scintillation detectors

We consider searches for dark matter annihilation to monoenergetic neutrinos in the core of the Sun. We find that liquid scintillation neutrino detectors have enhanced sensitivity to this class of dark matter models, due to the energy and angular resolution possible for electron neutrinos and antineutrinos that scatter via charged-current interactions. In particular we find that KamLAND, utilizing existing data, could provide better sensitivity to such models than any current direct detection experiment for m{sub X}≲15 Gev. KamLAND’s sensitivity is signal-limited, and future liquid scintillation or liquid argon detectors with similar energy and angular resolution, but with larger exposure, will provide significantly better sensitivity. These detectors may be particularly powerful probes of dark matter with mass O(10) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector

Purpose: Liquid scintillators have been shown to provide fast and high-resolution measurements of radiation beams. However, their linear energy transfer-dependent response (quenching) limits their use in proton beams. The purpose of this study was to develop a simple and fast method to verify the range, spread-out Bragg peak (SOBP) width, and output of a passive-scattering proton beam with a liquid scintillator detector, without the need for quenching correction. Methods: The light signal from a 20×20×20 cm3 liquid scintillator tank was collected with a CCD camera. Reproducible landmarks on the SOBP depth-light curve were identified which possessed a linear relationship with the beam range and SOBP width. The depth-light profiles for three beam energies (140, 160 and 180 MeV) with six SOBP widths at each energy were measured with the detector. Beam range and SOBP width calibration factors were obtained by comparing the depth-light curve landmarks with the nominal range and SOBP width for each beam setting. The daily output stability of the liquid scintillator detector was also studied by making eight repeated output measurements in a cobalt-60 beam over the course of two weeks. Results: The mean difference between the measured and nominal beam ranges was 0.6 mm (σ=0.2 mm), with a maximum difference of 0.9 mm. The mean difference between the measured and nominal SOBP widths was 0.1 mm (σ=1.8 mm), with a maximum difference of 4.0 mm. Finally an output variation of 0.14% was observed for 8 measurements performed over 2 weeks. Conclusion: A method has been developed to determine the range and SOBP width of a passive-scattering proton beam in a liquid scintillator without the need for quenching correction. In addition to providing rapid and accurate beam range and SOBP measurements, the detector is capable of measuring the output consistency with a high degree of precision. This project was supported in part by award number CA182450 from the National Cancer Institute.

07 ISOTOPE AND RADIATION SOURCES↗

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

A liquid scintillation detector for radioassay of gadolinium-loaded liquid scintillator for the LZ Outer Detector

© 2019 Elsevier B.V. We report on the design and performance of the LUX-ZEPLIN (LZ) “Screener”, a small liquid scintillator detector consisting of ≈23 kg of LAB-based gadolinium-loaded liquid scintillator (GdLS) to be used in the LZ Outer Detector. The Outer Detector will be filled with 17.3 tonnes of GdLS and will surround the central liquid xenon time projection chamber of LZ. Its primary function will be to tag neutron events in the liquid xenon which could mimic a WIMP dark matter signal. To meet the deadtime requirements for the Outer Detector, the radioimpurity levels in the GdLS must be kept below ≲0.07 mBq/kg. This background level corresponds to a rate of ≈50Hz above an energy threshold of 100 keV. The Screener was operated in the ultra-low-background environment of the former LUX water shield in the Davis Laboratory at the Sanford Underground Research Facility for radioassay of the GdLS. Careful selection of detector materials and use of ultra-low-background PMTs allows the measurement of a variety of radioimpurities. The 14C/12C ratio in the scintillator is measured to be (2.83±0.06(stat.)±0.01(sys.))×10 -17 . Use of pulse shape discrimination allows the concentration of isotopes throughout the 238U, 235U, and 232Th chains to be measured by fitting the collected spectra from α and β events. We find that equilibrium is broken in the 238U and 232Th chains and that a significant portion of the contamination in the GdLS results from decays in the 227Ac subchain of the 235U series. Predictions for the singles rate in the Outer Detector are presented. The rate from radioimpurities above 100 keV in the GdLS is estimated to be 97.9±6.4Hz, with 65.5±1.9Hz resulting from α-decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organic liquid scintillation detector shape and volume impact on radiation portal monitors

We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3 He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. As a result, a small number of organic liquid scintillation detectors could therefore be a valid alternative to 3 He in some RPM applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a ton-scale water-based liquid scintillator detector

This study reports the performance and light yield of 1% concentration water-based liquid scintillator (WbLS) deployed in a 1000-liter detector. A light yield of 99± 15 photons per MeV is determined by comparing data with simulation. This result aligns with our previous light yield determination using smaller detectors, thus establishing a solid foundation for the ongoing development and deployment of WbLS in larger-scale detectors. In conclusion, the feasibility of in situ preparation and the stability of light yield in WbLS are demonstrated, reinforcing its suitability for long-term experimental endeavors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A spectrometric approach to measuring the Rayleigh scattering length for liquid scintillator detectors

Good optical transparency is a fundamental requirement of liquid scintillator (LS) detectors. Characterizing the transparency of a liquid scintillator to its own emitted light is a key parameter to determine the overall sensitivity of a large-volume detector. The attenuation of light in an optical-pure LS is dominated by Rayleigh scattering, which poses an intrinsic limit to the transparency of LS. This work presents a spectrometric approach of measuring the wavelength-dependent scattering length of liquids by applying the Einstein-Smoluchowski theory to a measurement of scattered light intensity. The scattering lengths of linear alkyl benzene (LAB) and EJ309-base (Di-isopropylnaphthalene, DIN) were measured and are reported in the wavelength range of 410–520 nm. The spectral peak of scintillation light emitted by a nominal LS is around 430 nm at which the scattering lengths for LAB and EJ-309-base were determined to be 27.9 ± 2.3 m and 6.1 ± 0.6 m.

47 OTHER INSTRUMENTATION↗

Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector

Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector is described. The detector was placed at a location with little structure material in the field of view, and equipped with a gain monitoring system which could provide the possibility to evaluate the gain variation as well as to correct for the detector response. Time trace of the neutron emissivity was obtained and it was consistent with the result of a standard {sup 235}U fission chamber. During the plasma discharge the neutron yield could vary by about four orders of magnitude and the fluctuation of the detector gain was up to about 6%. Pulse height spectrum of the liquid scintillation detector was constructed and corrected with the aid of the gain monitoring system, and the correction was found to be essential for the assessment of the neutron energy spectrum. This successful measurement offered experience and confidence for the application of liquid scintillation detectors in the upcoming neutron camera system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus

The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. A CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

Aglietta, M.↗

The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

Dadykin, V. L.↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric charged $$K/\pi $$ ratio and measurement of muon annual modulation with a liquid scintillation detector at Soudan

We report a measurement of muon annual modulation in a 12-l liquid scintillation detector with a live-time of more than 4 years at the Soudan Underground Laboratory. Muon minimum ionization in the detector is identified by its observed pulse shape and large energy deposition. The measured muon rate in the detector is $$28.69\pm 2.09$$ 28.69 ± 2.09 muons per day with a modulation amplitude of ( $$2.64\pm 0.07$$ 2.64 ± 0.07 )% and a phase at Jul $$22 \pm 36.2$$ 22 ± 36.2 days. This annual modulation is correlated with the variation of the effective atmospheric temperature in the stratosphere. The correlation coefficient, $$\alpha _{T}$$ α T , is determined to be $$0.898 \pm 0.025$$ 0.898 ± 0.025 . This can be interpreted as a measurement of the atmospheric charged kaon to pion ( $$K/\pi $$ K / π ) ratio of $$0.094^{+0.044}_{-0.061}$$ 0 . 094 - 0.061 + 0.044 for $$E_{p} > 7$$ E p > 7 TeV, consistent with the measurement from the MINOS far detector. To further constrain the value of $$K/\pi $$ K / π ratio, a Geant4 simulation of the primary cosmic-ray protons with energy up to 100 TeV is implemented to study the correlation of $$K/\pi $$ K / π ratio and the muon annual modulation for muon energy greater than 0.5 TeV. We find out that a charged $$K/\pi $$ K / π ratio of 0.1598, greater than the upper bound (0.138) from this work at the production point 30 km above the Earth surface in the stratosphere cannot induce muon annual modulation at the depth of Soudan.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are a new class of detector materials that provide efficient and tunable detection of both Cherenkov and scintillation light. A massive WbLS neutrino detector with suitable photosensor coverage for low intensity light detection could therefore reconstruct the momentum of an energetic charged particle and also have enhanced low-energy sensitivity. These materials are also better suited for metal doping broadening the potential scientific utility. Here, we recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition and calibration system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early results.

47 OTHER INSTRUMENTATION↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗