Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIBS prototype”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Electronics Free Laser Sensing Technology for Minerals and Technology Elements

This presentation presents an electronics free laser sensing technique and its ongoing and potential applications. A laser-based technique, popularly known as laser-induced breakdown spectroscopy has been prototyped for the determination of high-tech elements including rare earth elements and other elements in solid as well as aqueous sources. All optical unit without any electronics has been designed in such a way that it can be installed in the source environment and connected to other required components for controlling and data acquisition from the workstation. Measurement methods and results obtained for selected elemental species and overall performance of the developed prototype will be presented.

HCM Sensor↗

Continued Development of in Situ Geochronology for Planetary Missions

The instrument 'Potassium (K) Argon Laser Experiment' (KArLE) is developed and designed for in situ absolute dating of rocks on planetary surfaces. It is based on the K-Ar dating method and uses the Laser Induced Breakdown Spectroscopy - Laser Ablation - Quadrupole Mass Spectrometry (LIBSLA- QMS) technique. We use a dedicated interface to combine two instruments similar to SAM of Mars Science Laboratory (for the QMS) and ChemCam (for the LA and LIBS). The prototype has demonstrated that KArLE is a suitable and promising instrument for in situ absolute dating.

geochronology↗

Galex and Optical Observations of GW Librae during the Long Decline from Superoutburst

The prototype of accreting, pulsating white dwarfs (GW Lib) underwent a large amplitude dwarf nova outburst in 2007. We used ultraviolet data from Galaxy Evolution Explorer and ground-based optical photometry and spectroscopy to follow GW Lib for three years following this outburst. Several variations are apparent during this interval. The optical shows a superhump modulation in the months following outburst, while a 19 minute quasi-periodic modulation lasting for several months is apparent in the year after outburst. A long timescale (about 4 hr) modulation first appears in the UV a year after outburst and increases in amplitude in the following years. This variation also appears in the optical two years after outburst but is not in phase with the UV. The pre-outburst pulsations are not yet visible after three years, likely indicating the white dwarf has not returned to its quiescent state.

NOVAE↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Applied Spectra, Inc.

Groundwater resources can be contaminated by a variety of surface and subsurface sources. For instance, metals can be leached from surface dumps (e.g. landfills, etc.) and reach groundwater supplies by percolation though the soil. Additionally, subsurface activities such as geologic carbon storage (GCS) could result in contamination. In the event of CO2 leakage, freshwater above the injection site can potentially be contaminated with metals either originating from the formation fluids or leached from formation rocks by CO2 acidification. Detection of these contaminating metals is critical for maintaining water safety and providing an early warning of a containment breach. Therefore, a compact, subsurface capable laser induced breakdown spectroscopy (LIBS) based sensor has been developed for groundwater quality monitoring applications. LIBS sensor technology has been advanced from benchtop feasibility studies to a custom fabricated, watertight prototype. The all optical sensor head is built using a low cost passively Q-switched (PQSW) laser, which is fiber coupled to a control unit containing the pump laser and a gated spectrometer. Separating the LIBS excitation laser from the pump and spectrometer allows the expensive and fragile components to remain in a safe, central location while only the sensor head needs to enter the subsurface. Testing of the prototype sensors show Limits of Detection (LODs) comparable to benchtop, actively Q-switched systems and has verified that the fiber coupling and triggering schemes perform as desired.

McIntyre, Dustin↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

Oxygen-Based Anion Redox for Lithium Batteries

The importance of current Li-ion batteries (LIBs) in modern society cannot be overstated. While the energy demands of devices increase, the corresponding enhancements in energy density of battery technologies are highly sought after. Currently, many different battery concepts, such as Li-S and metal-air among many others, have been investigated. However, their practical implementation has mostly been restricted to the prototyping stage. In fact, most of these technologies require rework of existing Li-ion battery manufacturing facilities and will naturally incur resistance to change from industry. For this reason, one specifically attractive technology, anionic redox in transition metal oxides, has gained much attention in the recent years. Its ability to be directly used in already established processes and higher energy density with similar electrolyte formulation make it a key materials research direction for next generation Li-ion batteries. In regular LIBs, the redox active centers are the transition metal cation. In anion redox, both the anion (typically O) and the transition metal cation are utilized as redox centers with enormous implications for increasing energy density. This new material can be highly competitive for replacing the current LIB technologies. However, much is still unknown about its cyding mechanism. Upon activating the O redox couples, most cationic and anionic redox active materials will either evolve O 2 or undergo irreversible structural degradation with associated severe decreases in electrochemical performance. By understanding the transition from full anion redox to partial cationic and anionic redo; we hope readers can gain a deeper understanding of the topic. This Account will focus mainly on the work that was conducted by our group at Argonne National Laboratory. Herein, the phenomenon of cationic and anionic redox in a lithium-ion battery cathode will first be discussed. Our work in resonant inelastic X-ray scattering to investigate the spectroscopic features of O after delithiation has found potential "fingerprint" signals that could likely be used to identify and confirm reversible O redox if corroborated with other techniques. To follow, we will examine our work on Li-O 2 batteries. While our group and the research community have had many significant contributions and improvements to the field of Li-O 2 (such as decreasing overpotential and achieving cyclability in air environment), its practical application is still far from realization. Perhaps our most important contribution to this area is the discovery that Ir deposited on reduced graphene oxide can be used to halt the reduction of O 2 at the LiO 2 oxidation state. This not only significantly decreases the charge overpotential but also presents the important concept of oxidation-state controlled discharge. Subsequently, we will focus on our oxidation state-controlled redox-based charging of oxygen in a pure oxygen redox Li-ion battery. Future implications of this technology will be emphasized.

25 ENERGY STORAGE↗

Development and Testing of Laser-induced Breakdown Spectroscopy for the Mars Rover Program: Elemental Analyses at Stand-Off Distances

One of the most fundamental pieces of information about any planetary body is the elemental composition of its surface materials. The Viking Martian landers employed XRF (x-ray fluorescence) and the MER rovers are carrying APXS (alpha-proton x-ray spectrometer) instruments upgraded from that used on the Pathfinder rover to supply elemental composition information for soils and rocks to which direct contact is possible. These in- situ analyses require that the lander or rover be in contact with the sample. In addition to in-situ instrumentation, the present generation of rovers carry instruments that operate at stand-off distances. The Mini-TES is an example of a stand-off instrument on the MER rovers. Other examples for future missions include infrared point spectrometers and microscopic-imagers that can operate at a distance. The main advantage of such types of analyses is obvious: the sensing element does not need to be in contact or even adjacent to the target sample. This opens up new sensing capabilities. For example, targets that cannot be reached by a rover due to impassable terrain or targets positioned on a cliff face can now be accessed using stand-off analysis. In addition, the duty cycle of stand-off analysis can be much greater than that provided by in-situ measurements because the stand-off analysis probe can be aimed rapidly at different features of interest eliminating the need for the rover to actually move to the target. Over the past five years we have been developing a stand-off method of elemental analysis based on atomic emission spectroscopy called laser-induced breakdown spectroscopy (LIBS). A laser-produced spark vaporizes and excites the target material, the elements of which emit at characteristic wavelengths. Using this method, material can be analyzed from within a radius of several tens of meters from the instrument platform. A relatively large area can therefore be sampled from a simple lander without requiring a rover or sampling arms. The placement of such an instrument on a rover would allow the sampling of locations distant from the landing site. Here we give a description of the LIBS method and its advantages. We discuss recent work on determining its characteristics for Mars exploration, including accuracy, detection limits, and suitability for determining the presence of water ice and hydrated minerals. We also give a description of prototype instruments we have tested in field settings.

D A Cremers↗

PowerGridworld: A Framework for Multi-Agent Reinforcement Learning in Power Systems: Preprint

We present the PowerGridworld software package to provide users with a light-weight, modular, and customizable framework for creating power systems-focused, multi-agent gym environments that readily integrate with existing training frameworks for reinforcement learning (RL). While many frameworks exist for training multi-agent (MA) RL policies, none exist to rapidly prototype and develop the environments themselves, especially in the context of heterogeneous (composite, multi-device) power systems where power flow solutions are required to define grid-level variables and costs. PowerGridworld is an open-source software package that helps to fill this gap. To highlight PowerGridworld's key features, we present two case studies and demonstrate learning multi-agent RL policies using both OpenAI's MADDPG and RLLib's PPO algorithms where, in both cases, at least some subset of agents incorporate elements of the power flow solution at each time step as part of their reward (negative cost) structures.

MATHEMATICS AND COMPUTING↗

Rare Earth Elements (REEs) Measurement in Coal and Rock Mineral Matrices

Although critical minerals including rare earth elements (REEs) can be analyzed in laboratory by some established and reliable laboratory based analytical techniques, their in-situ measurements in the field have always been challenging. For identification of REE-rich sites and REEs distribution measurement, portable field applicable technologies are paramount. As Laser-induced breakdown spectroscopy (LIBS) has enormous potential for field measurement, it has been explored for REEs measurements by many research groups. However, most of the studies are still dealing with simulated samples with traditional bench top experiments. In real world, REEs are available in various types of natural complex matrices in low content depending on the geographical locations. Considering this, LIBS has been evaluated for REE measurement in two different complex coal and rock mineral matrices representing some natural REE-rich sites. In addition, multiple samples collected from some natural sites in Wyoming, USA were experimented by using NETL’s bench top as well as miniaturized prototype setups for REE measurements.

Bhatt, Chet R.↗

The LIBRA Experiment: Investigating Robust Tritium Accountancy in Molten FLiBe Exposed to a D-T Fusion Neutron Spectrum

The Liquid Immersion Blanket: Robust Accountancy (LIBRA) experiment will be a first-of-a-kind experiment to explore and develop the liquid immersion blanket (LIB) concept. The LIB is a radically simple molten–LiF-BeF2 (FLiBe)–salt tritium breeding blanket for deuterium-tritium (D-T)–fueled fusion power plants (FPPs) achieving a high tritium breeding ratio (TBR) in neutronics models. However, tritium breeding in FLiBe is inherently difficult to study experimentally. As a result, the coupled issues of FLiBe radiochemistry and tritium (T) transport are poorly understood. LIBRA approaches this challenge by simulating an FPP blanket environment using a D-T neutron generator and ≈ 1000 kg of FLiBe. LIBRA will investigate T breeding, containment, and extraction, coupled with FLiBe redox control and radiochemistry. The primary goal of LIBRA is to demonstrate robust T accountancy in blanket prototypical conditions. Here, T accountancy encompasses accurate predictions of T breeding in the FLiBe; detection and measurement of all T bred in LIBRA; and speciation of the T extracted from the FLiBe. Initial neutronics simulations of LIBRA indicate that a global TBR of ~ 1 is possible, where the TBR is defined as the number of tritons bred and extracted from FLiBe relative to the number of neutrons produced by D-T fusion reactions in the neutron generator. In this paper, we present the LIBRA concept and its scientific goals in the context of T breeding experiments. We also consider the potential impact of the LIB on the future fusion power industry, motivating further development of FLiBe-based T breeding research activities such as LIBRA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Calibration of a Raman Spectrometer for use in a Laser Spectroscopy Instrument Intended to Analyze Martian Surface and Atmospheric Characteristics for NASA

This project's goal is the design of a Raman spectroscopy instrument to be utilized by NASA in an integrated spectroscopy strategy that will include Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Induced Florescence Spectroscopy (LIFS) for molecule and element identification on Mars Europa, and various asteroids. The instrument is to be down scaled from a dedicated rover mounted instrument into a compact unit with the same capabilities and accuracy as the larger instrument. The focus for this design is a spectrometer that utilizes Raman spectroscopy. The spectrometer has a calculated range of 218 nm wavelength spectrum with a resolution of 1.23 nm. To filter out the laser source wavelength of 532 nm the spectrometer design utilizes a 532 nm wavelength dichroic mirror and a 532 nm wavelength notch filter. The remaining scatter signal is concentrated by a 20 x microscopic objective through a 25-micron vertical slit into a 5mm diameter, 1cm focal length double concave focusing lens. The light is then diffracted by a 1600 Lines per Millimeter (L/mm) dual holographic transmission grating. This spectrum signal is captured by a 1-inch diameter double convex 3 cm focal length capture lens. An Intensified Charge Couple Device (ICCD) is placed within the initial focal cone of the capture lens and the Raman signal captured is to be analyzed through spectroscopy imaging software. This combination allows for accurate Raman spectroscopy to be achieved. The components for the spectrometer have been bench tested in a series of prototype developments based on theoretical calculations, alignment, and scaling strategies. The mounting platform is 2.5 cm wide by 8.8 cm long by 7 cm height. This platform has been tested and calibrated with various sources such as a neon light source and ruby crystal. This platform is intended to be enclosed in a ruggedized enclosure for mounting on a rover platform. The size and functionality of the Raman spectrometer allows for the rover to carry other mission critical devices. This project will be continued at NASA until the requirements are met for the expected initial 2020 launch date.

Lucas, John F.↗