Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LI-DRIFTED DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on the axion-electron coupling for solar axions produced by a Compton process and bremsstrahlung

The search for solar axions produced by Compton ({gamma}+e{sup -}{yields}e{sup -}+A) and bremsstrahlunglike (e{sup -}+Z{yields}Z+e{sup -}+A) processes has been performed. The axion flux in both cases depends on the axion-electron coupling constant. The resonant excitation of the low-lying nuclear level of {sup 169}Tm was looked for: A+{sup 169}Tm{yields}{sup 169}Tm{sup *}{yields}{sup 169}Tm+{gamma} (8.41 keV). The Si(Li) detector and {sup 169}Tm target installed inside the low-background setup were used to detect 8.41 keV {gamma} rays. As a result, a new model-independent restriction on the axion-electron and the axion-nucleon couplings was obtained: g{sub Ae}x|g{sub AN}{sup 0}+g{sub AN}{sup 3}|{<=}2.1x10{sup -14}. In the model of the hadronic axion this restriction corresponds to the upper limit on the axion-electron coupling and on the axion mass g{sub Ae}xm{sub A{<=}}3.1x10{sup -7} eV (90% C.L.). The limits on the axion mass are m{sub A{<=}}105 eV and m{sub A{<=}}1.3 keV for the Dine-Fischler-Srednicki-Zhitnitskii- and Kim-Shifman-Vainstein-Zakharov-axion models, correspondingly (90% C.L.).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IBIXFIT: A Tool For The Analysis Of Microcalorimeter PIXE Spectra

PIXE analysis software has been for long mainly tuned to the needs of Si(Li) detector based spectra analysis and quantification methods based on K{sub {alpha}} or L{sub {alpha}} X-ray lines. Still, recent evidences related to the study of relative line intensities and new developments in detection equipment, namely the emergence of commercial microcalorimeter based X-ray detectors, have brought up the possibility that in the near future PIXE will become more than just major lines quantification. A main issue that became evident as a consequence of this was the need to be able to fit PIXE spectra without prior knowledge of relative line intensities. Considering new developments it may be necessary to generalize PIXE to a wider notion of ion beam induced X-ray (IBIX) emission, to include the quantification of processes such as Radiative Auger Emission. In order to answer to this need, the IBIXFIT code was created based much on the Bayesian Inference and Simulated Annealing routines implemented in the Datafurnace code [1]. In this presentation, the IBIXFIT is used to fit a microcalorimeter spectrum of a Ba{sub x}Sr{sub (1-x)}TiO{sub 3} thin film sample and the specific possibility of selecting between fixed and free line ratios combined with other specificities of the IBIXFIT algorithm are shown to be essential to overcome the problems faced.

74 ATOMIC AND MOLECULAR PHYSICS↗

Equilibrium K-, L-, and M-shell ionizations and charge-state distribution of sulfur projectiles passing through solid targets

In the present work, an alternative approach for the evaluation of the equilibrium K-, L-, and M-shell ionizations and the mean charge state q for projectiles passing through various targets has been proposed. The approach is based on measured K x-ray energy shifts and line intensity ratios and utilizes the theoretical analysis of projectile spectra using multiconfiguration Dirac-Fock calculations. It was applied for the satellite and hypersatellite K lines in the x-ray spectra emitted by sulfur projectiles passing with energies of 9.6-122 MeV through carbon, aluminium, titanium, and iron targets, recorded by a Si(Li) detector. It was found that only in the high projectile energy region there was significant dependence of mean equilibrium K-shell ionization on the target atomic number. The equilibrium L-shell ionization rises with the increase of sulfur energy until 32 MeV, but for higher energies the changes are very weak. The equilibrium M-shell ionization changes very weakly for low projectile energy while for higher energies this ionization is practically constant. For each target, the estimated value of q rises with the increase of the sulfur energy value. The dependence of the sulfur charge state on the target atomic number was discussed by taking into account the cross sections for ionization, decay, and electron capture processes. The data were compared with the experimental data measured by other authors and with the predictions of Shima's and Schiwietz and Grande's semiempirical formulas. The presented good agreement points out that this alternative approach delivers quantitative results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Software realization of real-time neutrons and {gamma}-rays pulse shape discrimination using CUDA platform

The two pulse shape discrimination methods were implemented in real-time. The pulse gradient analysis method was implemented programmatically on PC. The method based on artificial neural network was programmatically implemented using CUDA platform. It is shown that both implementations can provide up to 10{sup 6} pulses per second processing performance. The results for pulse shape discrimination using polycrystalline stilbene and LiF detectors were shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combination of grazing incidence x-ray fluorescence with x-ray reflectivity in one table-top spectrometer for improved characterization of thin layer and implants on/in silicon wafers

As Grazing Incidence X-ray Fluorescence (GIXRF) analysis does not provide unambiguous results for the characterization of nanometre layers as well as nanometre depth profiles of implants in silicon wafers by its own, the approach of providing additional information using the signal from X-ray Reflectivity (XRR) was tested. As GIXRF already uses an X-ray beam impinging under grazing incidence and the variation of the angle of incidence, a GIXRF spectrometer was adapted with an XRR unit to obtain data from the angle dependent fluorescence radiation as well as data from the reflected beam. A θ-2θ goniometer was simulated by combining a translation and tilt movement of a Silicon Drift detector, which allows detecting the reflected beam over 5 orders of magnitude. HfO{sub 2} layers as well as As implants in Silicon wafers in the nanometre range were characterized using this new setup. A just recently published combined evaluation approach was used for data evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 10}Li low-lying resonances populated by one-neutron transfer

The {sup 9}Li + {sup 2}H → {sup 10}Li + {sup 1}H one-neutron transfer reaction has been performed at 100 MeV incident energy at TRIUMF using a {sup 9}Li beam delivered by the ISAC-II facility. A setup based on double-sided silicon strip detectors has been used in order to detect and identify the outgoing {sup 9}Li produced by the {sup 10}Li breakup at forward angles and the recoil protons emitted at backward angles. The {sup 10}Li low-lying resonances, whose energies, widths and configurations are still unclear, have been populated with significant statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon detectors aboard Surveyor V.

Conventional and Li-drifted Si charged particle detectors for alpha scattering experiment aboard Surveyor 5 noting operating characteristics, performance and electrical stability

Kristoff, J. J.↗

HILT - A heavy ion large area proportional counter telescope for solar and anomalous cosmic rays

The HILT sensor has been designed to measure heavy ion elemental abundances, energy spectra, and direction of incidence in the mass range from He to Fe and in the energy range 4 to 250 MeV/nucleon. With its large geometric factor of 60 sq cm sr the sensor is optimized to provide compositional and spectral measurements for low intensity cosmic rays (i.e. for small solar energetic particle events and for the anomalous component of cosmic rays). The instrument combines a large area ion drift chamber-proportional counter system with two arrays of 16 Li-drift solid state detectors and 16 CsI crystals. The multi dE/dx-E technique provides a low background mass and energy determination. The sensor also measures particle direction. Combining these measurements with the information on the spacecraft position and attitude in the low-altitude polar orbit, it will be possible to infer the ionic charge of the ions from the local cutoff of the Earth's magnetic field. The ionic charge in this energy range is of particular interest because it provides unique clues to the origin of these particles and has not been investigated systematically so far. Together with the other instruments on board SAMPEX (LEICA, MAST, and PET), a comprehensive measurement of the entire solar and anomalous particle population will be achieved.

Klecker, Berndt↗

Development of a coincidence system for the measurement of X-ray emission atomic parameters

Preliminary results obtained in experiments carried out with an x-ray spectrometer built at the Instituto de Fisica for Atomic Physics and environmental sciences studies are presented. The experiments are based on a coincidence method for signals produced by LEGe and Si(Li) detectors. The x-ray fluorescence yields ({omega}{sub Li}) and Coster-Kronig transition probabilities (f{sub ij}) for elements with 55 {<=} Z {<=} 60 are among the quantities of interest. The method is based on the simultaneous detection of K x-rays with the LEGe detector and the L x-rays with the Si(Li) detector. The primary radiation source is an x-ray tube with Rh anode. The system was tested with the coincidence of the L x-rays from Ce with its K line, demonstrating the feasibility of the experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early Experiments with a New In Situ SEM Heating Technology

A new heating technology (Protochips, Inc.) has recently been introduced for in situ electron microscopy studies, including both TEM and SEM applications. Aduro{trademark} heater devices, fabricated using MEMS-based processing, offer numerous advantages for in situ SEM applications over those using a miniaturized furnace. The device supports a sample on a thin ceramic membrane that is directly heated by passing a current of a few mA, thereby also heating the sample. The entire heated area of the device is only 500um x 500um, so it is operated without circulating cooling water. The extremely small heated zone enables a rapid temperature response (10{sup 6} C/s) for both heating and cooling, and it emits a far lower signal of photons and thermal electrons than a typical furnace-type heating device. This allows heating to temperatures in excess of 1000 C without totally degrading the secondary electron signal. The purpose of the present work is to characterize the factors that influence the image quality and resolution of the SEM during heating. We are interested in understanding relative changes of signal-to-noise levels and contrast in secondary electron (SE) and backscattered electron (BSE) images as a function of increasing the heating temperature. We have also assessed the capability for performing energy dispersive X-ray spectroscopy (EDS) during heating experiments. The in situ holder and the structure of a standard heater chip used in this study are shown in Fig. 1. The chip has an array of 5 {micro}m holes in the electrically conductive heater membrane, separated by electrode 'fingers' in this case. A C-flat{trademark} holey carbon film is overlaid on top of the heater membrane. The heating experiments were conducted in a Hitachi S3400 VP-SEM, operated at 15kV and equipped with an EDAX Si(Li) detector. Fig. 2 shows an Ir-doped FeSi particle situated near the edge of the hole in the membrane, imaged with secondary electrons through an Everhart-Thornley (ET) detector in the specimen chamber, at (2a) RT and at (2b) 1200 C, respectively. The image contrast of the low-Z region of the particle was characterized by an intensity profile across the edge of the holey carbon film against the hole (vacuum). Indicated by Line No.1, the contrast difference was 48% at RT, which dropped to 22% at 1200 C. However, the contrast difference of the medium-Z particle against the low-Z support was well above 30% at 1200 C (Line No.2). Heating had a more adverse effect on the contrast of BSE micrographs, likely caused by the direct detection of photons by solid-state BSE detector. The upper limit for acquiring a BSE micrograph of the low-Z material was about 850 C as the contrast was completely washed out by 900 C. EDS analyses carried out during heating showed effects primarily for the collection of low-energy X-rays (<1.2 keV) below a temperature of 600 C: the background counts increased with temperature, thus reduced the signal-to-noise ratio. The upper limit for EDS analysis during heating was about 700 C. The decrease in the signal-to-noise ratio for electron detection and EDS spectrum acquisition is mainly due to the emission of thermal electrons and photons at elevated temperatures. The emitted photons are not position sensitive, thus they uniformly raise the background level of a grayscale BSE image (photons do not affect the signal of the ET detector). However, thermal electrons in the range of {approx}0.1eV are collected by the ET detector, and thereby reduce contrast in the image. It is impressive that even at the highest temperature achievable by the Aduro device (1200 C), acceptable contrast in SE images is achieved. This is because of the extremely small emitting area of the heater membrane. One solution for improving the contrast of an SE micrograph is to suppress the thermal electrons by a small local positive bias. There are two approaches: (1) manipulating the positive bias of the ET detector or (2) using an energy filter to reduce or remove the thermal electrons. A combined Monte Carlo simulation and experimental study is underway to determine the optimal parameters for minimal detection of thermal electrons. We expect the findings from this study will allow for the optimization of the image contrast.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New limit on the mass of 14.4-keV solar axions emitted in an M1 transition in {sup 57}Fe nuclei

Axions of energy 14.4 keV that originated from the M1 transition in {sup 57}Fe nuclei in the Sun were sought by using the resonance-absorption reaction A+{sup 57}Fe {yields} {sup 57}Fe* {yields} {sup 57}Fe+{gamma} (14.4 keV). Asectioned Si(Li) detector arranged in a low-background facility was used to record photons from this reaction. This resulted in setting a new limit on the axion couplings to nucleons, vertical bar -1.19g{sub AN}{sup 0} + g{sub AN}{sup 3} vertical bar {<=} 3.0 Multiplication-Sign 10{sup -6}. Within the hadronic-axion model, the respective constraint on the axion mass is m{sub A} {<=} 145 eV (at a 95% C.L.).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The DRAGO gamma camera

In this work, we present the results of the experimental characterization of the DRAGO (DRift detector Array-based Gamma camera for Oncology), a detection system developed for high-spatial resolution gamma-ray imaging. This camera is based on a monolithic array of 77 silicon drift detectors (SDDs), with a total active area of 6.7 cm{sup 2}, coupled to a single 5-mm-thick CsI(Tl) scintillator crystal. The use of an array of SDDs provides a high quantum efficiency for the detection of the scintillation light together with a very low electronics noise. A very compact detection module based on the use of integrated readout circuits was developed. The performances achieved in gamma-ray imaging using this camera are reported here. When imaging a 0.2 mm collimated {sup 57}Co source (122 keV) over different points of the active area, a spatial resolution ranging from 0.25 to 0.5 mm was measured. The depth-of-interaction capability of the detector, thanks to the use of a Maximum Likelihood reconstruction algorithm, was also investigated by imaging a collimated beam tilted to an angle of 45 deg. with respect to the scintillator surface. Finally, the imager was characterized with in vivo measurements on mice, in a real preclinical environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlations of trace elements in breast human tissues: Evaluation of spatial distribution using {mu}-XRF

The aim of this work is to investigate microscopic correlations between trace elements in breast human tissues. A synchrotron X-ray fluorescence microprobe system ({mu}-XRF) was used to obtain two-dimensional distribution of trace element Ca, Fe, Cu and Zn in normal (6 samples) and malignant (14 samples) breast tissues. The experiment was performed in X-ray Fluorescence beam line at Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, Brazil. The white microbeam was generated with a fine conical capillary with a 20 {mu}m output diameter. The samples were supported on a XYZ table. An optical microscope with motorized zoom was used for sample positioning and choice the area to be scanned. Automatic two-dimensional scans were programmed and performed with steps of 30 {mu}m in each direction (x, y) on the selected area. The fluorescence signals were recorded using a Si(Li) detector, positioned at 90 degrees with respect to the incident beam, with a collection time of 10 s per point. The elemental maps obtained from each sample were overlap to observe correlation between trace elements. Qualitative results showed that the pairs of elements Ca-Zn and Fe-Cu could to be correlated in malignant breast tissues. Quantitative results, achieved by Spearman correlation tests, indicate that there is a spatial correlation between these pairs of elements (p < 0.001) suggesting the importance of these elements in metabolic processes associated with the development of the tumor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silicon drift detector based X-ray spectroscopy diagnostic system for the study of non-thermal electrons at Aditya tokamak

Silicon drift detector based X-ray spectrometer diagnostic was developed to study the non-thermal electron for Aditya tokamak plasma. The diagnostic was mounted on a radial mid plane port at the Aditya. The objective of diagnostic includes the estimation of the non-thermal electron temperature for the ohmically heated plasma. Bi-Maxwellian plasma model was adopted for the temperature estimation. Along with that the study of high Z impurity line radiation from the ECR pre-ionization experiments was also aimed. The performance and first experimental results from the new X-ray spectrometer system are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 kV. Conclusions: Ranging from 20 kV to 640 kV, 621 x-ray spectra were produced and are available at 1 kV tube potential intervals. The spectra are tabulated at 1 keV intervals. TASMICS spectra were shown to be largely equivalent to published spectral models and are available in spreadsheet format for interested users by emailing the corresponding author (JMB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bremsstrahlung in Mo and Pt targets produced by {sup 90}Sr beta particles in the photon energy region of 1-100 keV

Bremsstrahlung spectra in thick targets of Mo and Pt, produced by beta emitter {sup 90}Sr (end point energy = 546 keV) have been studied in the photon energy range of 1-100 keV. The experimentally measured bremsstrahlung spectra measured with Si(Li) detector were compared with the theoretical spectral distributions calculated from Elwert corrected (non relativistic) Bethe-Heitler [EBH] theory, modified Elwert factor (relativistic) Bethe-Heitler (F{sub mod}BH) theory for ordinary bremsstrahlung (OB) and the modified Elwert factor (relativistic) Bethe-Heitler (F{sub mod}BH+PB) theory, which includes the polarization bremsstrahlung (PB) into total bremsstrahlung (BS). The present results indicate the correctness of F{sub mod}BH+PB theory in the low energy region, where the contributions of PB into BS are dominant, which is described in terms of stripped atom (SA) approximation. But at the middle and higher energy region of the bremsstrahlung spectrum, where the contribution of PB is negligible, the F{sub mod}BH theory is more close to the experimental results. Hence, it is clear that the production of PB in the low energy region, due to the dynamic response of the target atom suppresses the production of bremsstrahlung at higher energy ends.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ex vivo evaluation of a coherent normalization procedure to quantify in vivo finger strontium XRS measurements

Purpose: Energy dispersive x-ray fluorescence spectroscopy (XRS) measurements were performed on human cadaver index fingers to measure bone strontium content in the presence of intact overlying soft-tissue. This work assesses the feasibility of applying a normalization procedure including soft-tissue correction of x-ray absorption as a means to quantify an ex vivo bone strontium XRS measurement. Methods: Bone strontium measurements were made using an excitation-detection system incorporating an {sup 125}I x-ray excitation source and an Ortec registered Ametek-AMT Si(Li) detector in 180 deg. backscatter geometry. Spectral processing was accomplished using an in-house nonlinear least-squares Marquardt fitting routine. Bone strontium was quantified using an egs5 Monte Carlo based x-ray soft-tissue correction algorithm in conjunction with the normalization of strontium x-rays to the coherent scatter peaks of 35.5 keV {sup 125}I {gamma}-rays. Results: Comparison of tissue intact and bare bone finger XRS measurement quantification attempts revealed an overall discrepancy of 18.6% that is attributed primarily to the significant contribution of soft-tissue to coherent scatter of 35.5 keV source {gamma}-rays and to a lesser degree, inconsistencies with the simulated tissue correction model. Work toward the beginnings of an experimentally derived tissue correction model, as a means to validate the simulated model, have been reported. Two observations hinted at a systematic inflation of the observed K{beta} peak area. First, strontium concentrations estimated by K{alpha} peak areas were less than the K{beta} peak areas by 28.6% (p < 0.0001) and 10.5% (p < 0.001) for tissue intact and bare bone measurements, respectively. Second, the K{alpha}:K{beta} x-ray average ratios between tissue corrected (3.61 {+-} 0.55) and bare bone predicted (4.4 {+-} 0.4) did not agree (p < 0.0001) and pointed to shortcomings with the current processing treatment of strontium K x-ray peak area extraction. Through finger bone XRS measurements, bone strontium concentration in the Caucasian population was estimated at 95 {+-} 15 {mu}g Sr/g dry bone. Conclusions: The discrepancies observed: between quantification attempts of tissue corrected and bare bone measurements, the inflated estimates of K{beta} relative to K{alpha} peak concentrations and between observed and expected K{alpha}:K{beta} ratios, have indicated that shortcomings with the bone strontium coherent normalization and tissue correction procedure exist. Coherent scatter contribution of soft-tissue overlying bone, tissue correction model limitations, and spectra processing issues are all mentioned as sources of observed discrepancies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗