Engineering PapersSearch

SEARCH · Engineering Papers

Results for “LEAKAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Risk assessment of wellbore leakage during underground hydrogen storage

The expansion of renewable energy sources would require large-scale energy storage options to overcome the intermittent nature of these sources. Underground hydrogen storage (UHS) in depleted hydrocarbon reservoirs offers a scalable and practical energy storage solution. These reservoirs are chosen for their availability and large capacity, but the unique properties of hydrogen raise concerns about potential leakage pathways, particularly through wellbores. In this study, we develop and apply, for the first time, reduced-order models (ROMs) specifically designed for efficient leakage risk prediction in UHS systems operating in depleted hydrocarbon reservoirs. Using 3,000 high-fidelity simulation scenarios, we examine the influence of 11 key parameters, including reservoir and aquifer depths, wellbore permeability and porosity, initial saturations of water, oil and gas fractions (hydrogen, light, intermediate, and heavy hydrocarbons), reservoir pressure multiplier, and the aquifer-to-reservoir volume ratio, to simulate leakage behavior over a 1,000-year timescale. We train ROMs using a two-step classification-regression approach, achieving R 2 values exceeding 99 % across all targets. These ROMs effectively capture the leakage evolution and identify critical controls of leakage, guiding the design of mitigation strategies. Results indicate that gas leakage occurs in about 27 % of scenarios as early as five years post-operation, reaching volumes of up to 106 ft3. Oil leakage is less frequent (~17 %) and typically begins decades later. Our findings also show that hydrogen often migrates first, owing to its smaller molecular size and higher buoyancy, followed by heavier hydrocarbons. Over time, these heavier components contribute significantly to the total leaked volume, reinforcing the need for targeted monitoring and remediation strategies. Our analysis highlights that deeper storage reservoirs, shallower aquifers, and low-permeability wellbores significantly reduce leakage risks. In conclusion, this work offers a robust framework for risk-informed UHS deployment, supporting energy security through reliable large-scale hydrogen storage while safeguarding environmental integrity.

08 HYDROGEN

Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN

Low leakage current in heteroepitaxial Al 0.7 Sc 0.3 N ferroelectric films on Ga N

Wurtzite ( Al , Sc ) N ferroelectrics are attractive for microelectronics applications due to their chemical and structural compatibility with wurtzite semiconductors, such as Ga N and ( Al , Ga ) N . However, the leakage current in epitaxial stacks reported to date should be reduced for reliable device operation. Here, we demonstrate low leakage current in epitaxial Al 0.7 Sc 0.3 N films on Ga N with well-saturated ferroelectric hysteresis loops that are orders of magnitude lower (i.e., 0.07 A cm − 2 ) than previously reported films (1–19 A cm − 2 ) having similar or better structural characteristics. We also show that, for these high-quality epitaxial ( Al , Sc ) N films, structural quality (edge and screw dislocations), as measured by diffraction techniques, is not the dominant contributor to leakage. Instead, the small leakage in our films is limited by thermionic emission across the interfaces, which is distinct from the large leakage due to trap-mediated bulk transport in the previously reported ( Al , Sc ) N films. To support this conclusion, we show that Al 0.7 Sc 0.3 N on lattice-matched In 0.18 Ga 0.82 N buffers with improved structural characteristics but higher interface roughness exhibit increased leakage characteristics. This demonstration of low leakage current in heteroepitaxial ( Al , Sc ) N films and understanding of the importance of interface barrier and surface roughness can guide further efforts toward improving the reliability of wurtzite ferroelectric devices. Published by the American Physical Society 2025

36 MATERIALS SCIENCE

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage

Quantifying the Potential Atmospheric Leakage Risks Associated With the Geologic Storage of CO 2 in Saline Aquifers for Use in Voluntary Carbon Market Buffer Account Determination

Conference paper presented at 17th International Conference on Greenhouse Gas Control Technologies (GHGT-17), Calgary, Alberta, Canada, October 20–24, 2024. This paper presents the results of a detailed study into the potential atmospheric leakage risks associated with the geologic storage of CO 2 in saline aquifers. This study included a detailed literature review, a re-creation of existing CO 2 leakage models put forth by other authors and, lastly, the development of an enhanced model that can be utilized for assessing the potential losses to the atmosphere of stored CO 2 across a variety of potential project parameters. The results of this study indicate that, across broad ranges of input parameters for mechanisms that have the potential for CO 2 loss from the storage complex to the atmosphere, there is an extremely low risk of CO 2 leakage to the atmosphere, with the median leakage risk estimated to be 0.1% of total injected CO 2 . The risk of leakage from real-world storage projects is likely to be even lower than those estimated through this study.

01 COAL, LIGNITE, AND PEAT

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)

Circuit-Based Leakage-to-Erasure Conversion in a Neutral-Atom Quantum Processor

Atom-loss errors are a major limitation of current state-of-the-art neutral-atom quantum computers and pose a significant challenge for scalable systems. In a quantum processor with cesium atoms, we demonstrate proof-of-principle circuit-based conversion of this form of leakage error to erasure errors via leakage-detection units (LDUs), which nondestructively map information about the presence or absence of the qubit onto the state of an ancilla. We benchmark the performance of the LDU using a three-outcome low-loss state-detection method and find that the LDU detects atom-loss errors with approximately 93.4% accuracy, limited by technical imperfections of our apparatus. We further compile and execute a SWAP LDU, wherein the roles of the original data atom and ancilla atom are exchanged under the action of the LDU, providing “free refilling” of atoms in the case of atom loss. This circuit-based leakage-to-erasure error conversion is a critical component of a neutral-atom quantum processor where the quantum information may significantly outlive the lifetime of any individual atom in the quantum register. Finally, we demonstrate that LDUs may also be used to handle other forms of leakage errors where population moves to states outside of the computational subspace.

Chow, Matthew N. H. [Sandia National Laboratories

MR13A-3183: Microbial and Geochemical Characterization of Groundwater: Implications for Underground Hydrogen Storage Leakage

Underground hydrogen storage (UHS) in geological formations is a key element of the clean energy transition as it enables the decarbonization of the transportation and industrial sectors by decoupling hydrogen production and storage. UHS has many benefits, including low cost, much wider availability, large storage capacity, well-established infrastructure, and increased safety because of geological sealing capabilities. However, the impact of hydrogen (H2) biogeochemical interactions in the presence of subsurface microorganisms is largely neglected from UHS perspectives. These interactions might affect the effectiveness of storage and can even cause H2 to leak into the shallow aquifers. Leakage of H2 into groundwater can change the geochemistry and induce several microbial-driven processes. Microorganisms, such as sulfate-reducers, are naturally abundant in groundwater and consume H2 to produce hydrogen sulfide (H2S), which can contaminate the freshwater drinking groundwater and cause damage to infrastructure. Hydrogen leakage can also trigger microbial reactions responsible for metal mobility, which can impact the water quality. However, the kinetics of these reactions and the temporal impact of hydrogen leakage in groundwater are still unknown. Therefore, a time series hydrogen-groundwater interaction experiment was conducted, and the changes in fluid chemistry and headspace gas composition will be analyzed along with DNA sequencing results to understand the extent and kinetics of biogeochemical reactions that occur if hydrogen leaks into groundwater. In the experiments, Ultra High Purity (UHP) hydrogen gas will be injected into glass vials with groundwater samples, for a designated time period. For each glass-sealed vial, 16S rRNA gene sequencing, IC, ICP-MS, and GC-TCD will be performed. The experiments provide insights into plausible impacts of hydrogen leakage into shallow drinking water aquifers.

Clark, Allison [West Virginia University (WVU)]

Overview of leakage scenarios in supervised machine learning

Machine learning (ML) provides powerful tools for predictive modeling. ML’s popularity stems from the promise of sample-level prediction with applications across a variety of fields from physics and marketing to healthcare. However, if not properly implemented and evaluated, ML pipelines may contain leakage typically resulting in overoptimistic performance estimates and failure to generalize to new data. This can have severe negative financial and societal implications. Our aim is to expand understanding associated with causes leading to leakage when designing, implementing, and evaluating ML pipelines. Illustrated by concrete examples, we provide a comprehensive overview and discussion of various types of leakage that may arise in ML pipelines.

97 MATHEMATICS AND COMPUTING

Quantitative analysis of leakage current in III-nitride micro-light-emitting diodes

In this study, the electrical characteristics under forward- and reverse-bias conditions of III-nitride blue and green micro-light-emitting diodes (μLEDs) are analyzed. A fitting model is proposed to determine the contributions of reverse leakage current and the effectiveness of sidewall treatments. Moreover, the forward-bias currents of the μLEDs are examined using the extracted ideality factor to examine the impacts of sidewall defects. The results show that sidewall treatments are highly effective for suppression of leakage currents. From the efficiency perspective, higher wall-plug efficiency (WPE) than external quantum efficiency (EQE) is observed when the operating voltage is lower than the photon voltage in both blue and green 20 × 20 μm 2 devices. This enhancement of the WPE over the EQE is due to the suppression of Shockley–Read–Hall (SRH) nonradiative recombination. These observations indicate that μLEDs with sidewall treatments not only improve optical performance but also further enhance the electrical performance of devices by suppressing the leakage current paths due to SRH nonradiative recombination processes.

42 ENGINEERING

Wafer-scale high-k SrTiO 3 dielectrics with rational barrier-layer design for low leakage and high charge density

High-k oxides such as SrTiO 3 promise large capacitance, but their dielectric response is often limited by leakage currents due to reduced bandgaps. We show that introducing a thin barrier layer beneath SrTiO 3 is a simple and effective way to suppress leakage and increase charge density. Using hybrid molecular beam epitaxy, we grew uniform SrTiO 3 films on Nb:SrTiO 3 , CaSnO 3 /Nb:SrTiO 3 , and 2-in. SiO 2 /p-Si stacks to directly compare how different barrier layers influence device behavior. Both CaSnO 3 and SiO 2 reduce leakage, but the ultra-wide-bandgap SiO 2 layer enables much higher operating voltages, yielding charge densities exceeding 5 × 10 13 cm −2 at room temperature—more than a fivefold enhancement compared to devices without a barrier layer. This improvement comes with a predictable trade-off: the lower dielectric constant of SiO 2 reduces overall capacitance, making its thickness an important design parameter. Together, these results demonstrate that rational barrier-layer engineering—including wafer-scale integration on Si—provides a clear pathway to achieving higher charge densities in SrTiO 3 -based dielectric devices.

36 MATERIALS SCIENCE

The influence of V-defects, leakage, and random alloy fluctuations on the carrier transport in red InGaN MQW LEDs

Red InGaN-based light-emitting diodes (LEDs) exhibit lower internal quantum efficiencies than violet, blue, and green InGaN LEDs due to a reduction in radiative recombination rates relative to non-radiative recombination rates as the Indium composition increases. Additionally, the larger polarization and band offset barriers between high indium content InGaN quantum wells and GaN quantum barriers increase the forward voltage. In blue and green LEDs, random alloy fluctuations and V-defects play a key role in reducing the forward voltage. When V-defects are present, either naturally or intentionally introduced, they create an alternative path for carrier injection into the MQWs through the V-defect sidewalls. This injection mechanism explains the turn-on voltages of green LEDs. However, in InGaN red LEDs, these two phenomena do not reduce the forward voltage as effectively as in blue and green LEDs, and consequently, the computed forward voltage remains significantly higher than the measured one. Furthermore, currents are observed at low voltages before the turn-on voltage (V<ℏω/e=2.0 V) of red LEDs. To address this, we introduce dislocation-induced tail states in the modeling, suggesting that leakage current through these states may play a significant role both below and at turn-on voltages. The simulation also indicates that leakage carriers below turn-on accumulate, partially diffuse in the QWs, screen the polarization-induced barrier in the low injection regime, and further reduce the forward voltage. Despite these beneficial effects, a drawback of dislocation-induced tail states is the enhanced nonradiative recombination in the dislocation line region. This study provides a detailed analysis of device injection physics in InGaN QW red LEDs and outlines potential optimization strategies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Development of novel techniques for non-invasive air leakage and moisture detection in building envelopes

Unwanted air leakage and moisture in building envelopes can cause high energy consumption, detrimental indoor air quality, poor occupant comfort, and reduction in building material durability. High moisture can cause rot and mold, leading to costly and time-consuming repairs that add to the carbon burden of the building envelope. Novel detection techniques for locating and measuring air leakage flow and areas of high moisture in building envelopes will be presented. The techniques are easy, fast, and non-destructive which can enable quick building envelope assessment, foster retrofits, and lead to energy savings and carbon emission reduction.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)

Emissions leakage and economic losses may undermine deforestation-linked oil crop import restrictions

Import restrictions on deforestation-linked commodities are being considered strategies to reduce global deforestation and emissions. However, limited market share of importers imposing such restrictions and the potential for emissions leakage could reduce their effectiveness. Moreover, they could result in negative economic implications for producers and consumers. We quantify future emissions and economic implications of oil palm and soybean import restrictions. Current EU restrictions will likely have minimal impact due to the EU’s otherwise small and diminishing share of global palm and soy demand. If extended beyond the EU, such import restrictions could drive reductions in cumulative LUC emissions by 2050 in key oil crop exporting regions— up to 0.9% in Indonesia, 1.5% in the rest of Southeast Asia, 3.8% in Argentina and 6.7% in Brazil, relative to a scenario with no import restrictions. However, these key exporters could also face losses ranging $\$$4.1-$\$$61 billion in cumulative agricultural production revenue by 2050.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic