Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAK TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASA-STD-7012 Leak Test Requirements: Potential Reference for ASNT Nondestructive Testing Handbook for Leak Testing

Developed in 2018-2019, NASA-STD-7012 Leak Test Requirements, has been drafted based mostly on the NASA technical requirement documents applicable to the International Space Station (ISS) hardware and payloads that were developed over the years taking into consideration many known references such as Leakage Testing Handbook prepared by General Electric for the Jet Propulsion Laboratory, the ASTM International standards for leak testing, and last, but not least, the ASNT Nondestructive Testing Handbook for Leak Testing. Thus, NASA-STD-7012 has a reference to the above-mentioned handbook in the leak test method/technique descriptions. However, there are some technical details that are described differently in NASA standard and ASNT Handbook. Those technical details are mostly related to the classification of the leak test methods/techniques, and also to tracer gas to working fluid (gas or liquid) leakage rate conversion methodology, and to some definitions used in the text of both NASA standard and ASNT Handbook. Those differences are going to be briefly described in this paper to let ASNT leak test experts decide if they want to refer to NASA-STD-7012 while working on the next edition of the ASNT Handbook, Volume 2 for Leak Testing.

Lvovsky, Oleg M.↗

Fitting Leak Test Report: Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

EXECUTIVE SUMMARY Mechanically connected joints used in cryogenic fluid lines as part of space flight elements need to survive launch vibrations and remain leak-free to minimize the loss of on-board commodity and hazardous gas accumulation. In 2020, a cryogenic test apparatus was developed which can evaluate the leak performance of pressurized threaded fluid fittings. The fittings were mounted in the TVAC and cooled to cryogenic test temperature and pressurized with helium while the leak rate was measured using a calibrated GHe leak detector. The test articles for the initial proof of concept testing were ¼ and 1 inch Swagelok VCR fittings with three different types of seal rings copper, nickel, and Ni. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles, followed by exposure to a launch vibration profile at ambient temperature, after which two additional TVAC cycle tests were performed. The testing reported here is a continuation of the 2020 tests with a statistically significant large number of samples and test runs. Three Swagelok VCR fitting sizes were tested ¼, ½ and 1 inch, and five (5) samples of each fitting size, each sample was tested with SST and Ni seal rings (Total of 30 unique test articles). Each test article was subjected to four (4) thermal cycles. Half of these cycles were performed before vibration testing and half were performed after vibration testing. The vibration testing was performed to evaluate the ability of the fittings to survive launch-type vibration profiles and remain leak-free. Leak checking of each fitting was completed at temperatures between 20K – 30K. The test procedure in Section 8.0 was designed to facilitate a qualification test program by allowing a higher test throughput rate coupled with repeatable test profiles. Results were very positive and show that out of the 30 samples they all passed with leak rates a factor of 2-3 lower than the established 10-6sccs GHe leak threshold. The result showed the Ni seals had lower leak rate, but the SST was more rugged. There were two deviations where damage to the Ni seal ring during assembly resulted in a leaky fitting, this is discussed in Section 10.7 Test Deviations. These fittings show great promise for space flight use and further testing is recommended to fully qualify the fittings per the ASTM F1387-19 and/or other relevant NASA specifications. The test equipment hardware and software capability developed for this testing is generic and not restricted to VCR fittings. It can be employed to evaluate/qualify the leak performance of other types of fittings and a wide range of other cryogenic fluid components such as valves, gages, connectors, etc.

Cryogenic↗

Leak testing

Leak-testing methods for gas and liquid systems are described. The physical principles of molecular, liquid, and gas flow; relations of leak-testing methods and instrumentation; and tracer gases used in testing vacuum systems are discussed.

Engelhardt, R. E.↗

Orifice leak test

Orifice leak test for electronic components hermeticity

Altshuler, T. L.↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly

DOE manages over 300 types of SNF, most of which are located at the INL site. “Road-ready dry storage” is a management concept where SNF is packaged into dry, sealed canisters, which are then placed in on-site storage in anticipation of later removal. The Idaho Cleanup Project and INL are collaborating on the Road-Ready Capability Demonstration Project, which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE SNF for road-ready dry storage. In support of establishing a large-scale road-ready dry storage program at the INL site, the demonstration will package a select amount of DOE-managed SNF into DOE Standard Canisters. The closure process for the DOE Standard Canisters will include fuel and basket loading, welding, inspection, leak testing, and if needed, repair. As a follow-up to previous discussion on the design of the DOE Closure Leak Test Assembly, this report describes recent fabrication and testing efforts performed at INL. DOE Standard Canisters are sealed by two sequential gas tungsten arc welds. Both are performed by remotely operated and semi-autonomous welding systems. The first weld is a circumferential pipe weld that completes assembly of the canister body and lid assembly. The second and final closure weld connects the vent plug to the vent port with an identical butt joint to the circumferential pipe weld. After the second weld is performed on the vent port, these welds are helium leak tested using an inside-out technique. In addition to the commercially available vacuum and leak detector systems, the DOE Standard Canister Closure Leak Test Assembly was designed for both remote and manual operation. This report describes fabrication and performance testing associated with the inside-out technique. INL staff designed and tested systems to accomplish these tasks. Hardware fabrication occurred at INL facilities. Forthcoming work includes design optimization, integration to existing systems, and implementation to packaging demonstration operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

42 ENGINEERING↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly – 24139

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mass-Flow-Meter Leak-Testing System

Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

Sorensen, Eric B.↗

Filter Efficiency and Leak Testing of Returned ISS Bacterial Filter Elements After 2.5 Years of Continuous Operation

The atmosphere revitalization equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provides the vital functions of maintaining a habitable environment for the crew as well as protecting the hardware from fouling by suspended particulate matter. Providing these functions are challenging in pressurized spacecraft cabins because no outside air ventilation is possible and a larger particulate load is imposed on the filtration system due to lack of sedimentation in reduced gravity conditions. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) filters deployed at multiple locations in each module. These filters are referred to as Bacteria Filter Elements (BFEs). As more experience has been gained with ISS operations, the BFE service life, which was initially one year, has been extended to two to five years, dependent on the location in the U.S. Segment. In previous work we developed a test facility and test protocol for leak testing the ISS BFEs. For this work, we present results of leak testing a sample set of returned BFEs with a service life of 2.5 years, along with particulate removal efficiency and pressure drop measurements. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS to 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗

3013 Inner Can Lid Leak Test System Development

Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Personnel Qualification and Certification Program in Pressure Decay Leak Testing on the RT-100 Type (B) Cask - 17229

The requirements for qualifications and certification of leak test personnel on Type (B) shipping casks have been more clearly defined with the recent release of ANSI N14.5-2014, Leak Tests on Radioactive Packages for Shipment. The latest version creates a standardized approach for qualifying and certifying personnel to conduct pre-shipment leakage tests on Type (B) packages. The U.S Nuclear Regulatory Commission (NRC) is currently updating the Regulatory Guide R.G 7.4, Leakage Tests on Packages for shipment of Radioactive Material, to endorse ANSI N14.5-2014. According to ANSI N14.5-2014, leakage testing shall be performed in accordance with written procedures by qualified and certified personnel in accordance with the requirements of ASNT SNT-TC-1A-2006, Recommended Practice for Personnel Qualification and Certification in Nondestructive Testing. This is a significant modification to the old standard, ANSI N14.5-1997, which simply states that pressure leak testing shall be conducted by trained and certified personnel without reference to any specific certification standards or regulations. SNT-TC-1A published by the American Society for Nondestructive Testing (ASNT) has several advantages to employers; namely, it allows for a Limited NDT Level II certification program. Limited certifications are especially valuable for personnel who possess limited experience and wish to become a certified Limited NDT Level II in a specific technique on a specific cask using a specific procedure and equipment. Robatel Technologies recently developed a comprehensive qualification and training program based on the recommendations of SNT-TC-1A for Exelon Corporation to certify their employees to a Limited NDT Level II in Pressure Decay Leak Testing on the RT-100 Cask. The project scope included the development of a training and qualification program (Written practice), writing a pressure decay leak test procedure, the design of a pressure decay leak test manifold, and the delivery of classroom training. The written practice outlines the requirements to ensure that personnel participating in the program have the necessary qualification, experience, and training to become certified in the leak test method. The program will give Exelon the liberty to conduct their own leak testing on the RT- 100 without the need to rely on outside resources for leak testing. When fully implemented, the program is expected to improve productivity and eliminate schedule delays, along with substantial economic benefits. Following the appropriate standards and industry best practices, the project was successfully completed and scheduled to be fully implemented by Exelon's Nuclear Stations by the end of 2016. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Temporary Sealing of Cavities for Leak Testing

Wax Seals cavity openings to permit helium leak test of cavity welds. Technique facilitates leak testing of cavities in components of larger systems not otherwise sealed off at time leak testing done.

Little, J.↗

Pressure Change Measurement Leak Testing Errors

A pressure change test is a common leak testing method used in construction and Non-Destructive Examination (NDE). The test is known as being a fast, simple, and easy to apply evaluation method. While this method may be fairly quick to conduct and require simple instrumentation, the engineering behind this type of test is more complex than is apparent on the surface. This paper intends to discuss some of the more common errors made during the application of a pressure change test and give the test engineer insight into how to correctly compensate for these factors. The principals discussed here apply to ideal gases such as air or other monoatomic or diatomic gasses; however these same principals can be applied to polyatomic gasses or liquid flow rate with altered formula specific to those types of tests using the same methodology.

Leak Test↗

Cryogenic leak testing of tube fittings/valves

A high pressure and variable temperature cryogenic leak testing system was conceived and designed in order to conduct leakage testing of pipe fittings/valves in liquid hydrogen supply lines of the Space Shuttle. The system can create a continuous testing environment of variable temperature, 5.5 to about 300 K, and variable pressure, 0.01 to about 70 x 10 exp 5 Pa, with a large sample space, 90 mm diameter x 228 mm length, and at low operating cost. In terms of cryogenic leak testing the system has a special capability for extensive applications. The system comprised a variable temperature cryostat, a high pressure sample chamber, a vacuum pumping station, gas flow control system, pressure and temperature control systems, and leak detecting and measuring systems. A general discussion of cryogenic leak testing methods is also presented.

Jia, L. X.↗

75K Leak Test of October 2014

A leaking flange in Room 34B in May 2014 led to an awareness that secondary containment in some rooms at the Radioactive Liquid Waste Treatment Facility (RLWTF), Building 50-01, would not hold the contents of the largest vessel in the room. A proposal was developed to unplug floor drains, thereby allowing the 75K tank to be used as a large sump. A six day leak test, conducted from Oct-02 to Oct-08, clearly demonstrated that the 75K tank is leak-free below the level (36%) sufficient to hold the entire contents of the largest vessel within the RLWTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DOESC Closure Leak Test Assembly

This conceptual design report is for the DOESC Closure Leak Test Assembly, which satisfies a portion of the milestone "Preliminary Design Report for Remote Helium Leak Test System". This CDR is part of the Preliminary Design Report/Package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗